Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date21 Jun 2024
Closing Date19 Jul 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition brick tile/cement concrete tiles / APP membrance by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.

1400

-

-

... More
M&L for cement concrete type B0 (1:2:4 ) using 12.5 mm graded stone aggregate as in padding, coping, roof kerb incl hunching, benching etc complete all as specified and directed.

56

-

-

... More
M&L for 10 mm thick in CM(1:3) rendering on fair faces concrete surfaces/roof top mixed with liquid water proofing compound finished even & smooth without using extra cement complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.

1400

-

-

... More
Supply only liquid water proofing compound complete all as specified and directed. Make Dr. Fixit or equivalent.

350

-

-

... More
M & L preparation of newly plastered sufaces of roof including cleaning the surfaces by using wire brush / pressure hose and applying high performance polyurethene liquid membrane waterproofing coating cold applied in two coats @ 1.5Kg /Sqm/ 2 coats spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging abiltity of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet, complete as per manufacturer's instructions complete all as specified and directed. Note : 1. The contractor shall submit a gurantee of 10 years from the date of completion of work for waterproofing treatment alongwith manufacturer's gurantee. The amount of Rs. 40 ( Forty ) per Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money. 2. The water proofing shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work.

400

-

-

... More
M&L water proofing treatment to roof slab with APP modified polymeric membrane thickness not less than 3 mm plain membrane (weight of membrane not less than 3.50 Kg +/- 5% per Sqm) and weight of centre core polyster mat shall be 160 gram +/- 15% per Sqm and lower side finished with 10 to 15 micron thermo fusible polyethylene complete all as specified and directed by Engineer-in-Charge with following courses of descriptions below :- (a)The surface of roof, parapet and gutters and drains mouth etc over which waterproofing treatment is to be applied shall be thoroughly cleaned of all foreign matter, moss dust etc by wire-brushing and dusting. For cast iron/PVC drains outlets a grove shall be cut around to tuck in the treatment. Concrete angles-fillets provided at junctions between roofs and verticals faces of walls (parapet and other walls) around obstacles such as pipe, chimney stacks etc and other similar situation to ease up about corners. (b) On the prepared surface one coat of Solvent based bituminous primer (Sika® WP shield Primer or other techno commercially Equivalent make of STP/IWL ) shall be applied @ 0.35 to 0.50 Kg/sqm till the surface is properly impregnated. The time delay of laying of membrane after application of primer shall be as per manufacturer instructions. (c) Laying of polymeric waterproofing membrane and bonded completely to the substrate & the overlaps are then sealed /fused by flame torch as per manufacturer instructions. (d) The overlaps shall be of minimum 4 Inch (100 mm) side lap and 150mm at end ,sealed by the flame-torch. Note : 1. The contractor shall submit a gurantee of 10 years from the date of completion of work for waterproofing treatment alongwith manufacturer's gurantee. The amount of Rs. 25 (Twenty Five) per Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money. 2. The water proofing shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work.

1000

-

-

... More
M&L for preparation of new surfaces and applying two coats of aluminium paint over a coat of aluminium primer on membrane, over 10cm in width or girth complete all as specified and directed.

200

-

-

... More
M&L for cement concrete tiles 25cm x 25cm x 25mm thick, laid over 15 mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed.

600

-

-

... More
M&L for brick tiles 40mm thick with min flexural strength 1.5 N/Sqmm set, joints grouted flush in CM 1:3 mixed with liquid water proofing compound by weight of cement as per manufactur instruction over 15 mm thick screed bed in CM 1:4 , ponding test shall be done after laying of tiles complete all as specified and directed. (Liquid WPC shall be measured and paid separately)

200

-

-

... More
Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges complete all as specified and directed.

1100

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.

5.96

-

-

... More
Dismantling of unframed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.

2

-

-

... More
S&F MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.

1785

-

-

... More
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of required size and dia complete all as specified & directed.

1000

-

-

... More
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws of required size and dia complete all as specified and directed.

100

-

-

... More
S&F MS wind ties for roof including securing bolts as directed, including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.

150

-

-

... More
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide & over 10cm width or girth complete all as specified and directed.

107.1

-

-

... More
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide n.exc 10cm width or girth complete all as specified and directed.

15

-

-

... More
Demolition of unreinforcement cement concrete of any description and in position not otherwise specifically provided for complete all as specified and directed.

3

-

-

... More
M&L for PCC type B0 (1:2:4 using 12.5mm graded stone aggregate) as in roof kerb, benching/ padding over roof surface including chamfered on eges etc complete all as specified and directed.

2

-

-

... More
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, filling for fixing of hold fast etc including necessary formwork etc complete all as specified and directed.

1

-

-

... More
Dismantling wall or ceiling boards (fibre, pulp insulation etc) any thickness & at any height including fittings/grids etc complete all as specified and directed.

230

-

-

... More
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225 : 1987, Noncombustable as per BS 476 (part 4) - 1970 and light reflectance of 85% (minimum) including and to be laid in true horizontal level suspended on interlocking metal T-Grid of not dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing complete all as specified and directed.

100

-

-

... More
S&F ARMSTRONG SILHOUETTE EXPOSED GRID. The grid shoud be of Armstrong make 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600mm module, cut cross tees longer than 600mm require independent support 600 x 600mm module to be formed by fitting 600mm long cross tees centrally between the 1200mm cross tees. The 1200mm cross tees to have central "birdsmouth" notches to facilitate fitting of 600mm cross tees. Perimeter trim to be Armstrong wall angles, secured to walls at 450mm maximum centres. Hangers made of galvanised steel of size 26x26x25x1.2mm with a galvanised thickness of 80 grm/Sqm. A pre straightened hanger wire of dia 2.68mm of 1.83m length , thickness of 80grm/Sqm and a tensile strength of 344 - 413 MPa, alongwith adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68mm with a minimum pull strength of 110 Kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner complete all as specified and directed.

130

-

-

... More
M & L for providing 8mm thick gypsum board PVC laiminated ceiling tiles of size 595 x 595 mm , fixed or laid/ inserted to timber/GI/Aluminium frame work as in ceiling, with / without screws, having RH-95%, light reflectance 0.82 - 0.85 complete all as specified and directed.

130

-

-

... More
M & L for providing 8mm thick gypsum board PVC laiminated ceiling tiles of size 595 x 595 mm , fixed or laid/ inserted to timber/GI/Aluminium frame work as in ceiling, with / without screws, having RH-95%, light reflectance 0.82 - 0.85 complete including taking down ceiling boards complete all as specified and directed.

20

-

-

... More
Dismantling PVC water tanks of capacity exc 250 ltr but n exc 500 ltr and removing to store complete all as specified and directed.

5

-

-

... More
S&F HDPE triple layer rotational moulded polyethylene water storage tanks in white colour (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.

5

-

-

... More
Disconnecting existing water tank, setting aside (for lowering if required) for repair, cleaning etc. and hoisting, reconnecting and re-fixing in same position in new errected cage including cleaning of tank of capacity exc. 250 ltrs but not exc. 500 ltrs complete all as specified and directed.

12

-

-

... More
S&F ball valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed 20mm bore complete all as specified and directed.

5

-

-

... More
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed 20mm bore complete all as specified and directed.

5

-

-

... More
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.

20

-

-

... More
S&F 15 mm bore galvanized steel tubes medium grade with all fittings laid concealed/surface in walls complete all as specified and directed.

20

-

-

... More
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.

50

-

-

... More
S&F 20 mm bore galvanized steel tubes medium grade with all fittings laid in walls complete all as specified and directed.

50

-

-

... More
Dismantiling of concrete by chiselling from RCC members like col, beam, parapet, facia, ceiling etc exposing the reinforcement without disturbing the reinforcement and get free from rust by sand blasting providing at places addl reinforcement welding with existing reiforcement as directed wherever required binding with welded mesh 100 mmx100mm (12 gauge welded mesh) & tack welding and primed with using Araldite epoxy resins ( manufactured by M/s Ciba Geigy Ltd/ FAIR BOND EP/Sika or other approved manufacture) & provision of guniting pressure 2 to 3 Kg/Sqm with admixer 1 cement 3 sand mixed Dr fixit Pidicrete SC plasticiser (2 to 10% by weight of cement) of thickness 40mm average including stripping, floating with wooden strippers for proper dimension control inclusing necessary form work & scaffolding up to Three storey complete and surface of guniting to be finished fair and even with and including 10 mm thick plaster in cement mortar 1:4 with water proffing compound @3% by weight of cement, cleaning & removing of waste material etc as directed at site including necessary painting,white wash, distemper/ exterior acrylic emulsion).All surrounding wall, joineries and fitting should be covered with polythene sheet by contractor while work. (Any wall, floor,fittings and roof damaged by the contractor shall be repaired/change by contractor under same item and no extra payment will be paid to contractoron this account complete all as specified and directed. Note: Welded mesh & addl reinforcement if required measured and paid separetly.

260

-

-

... More
M & L for Mild steel TMT bar 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally, binding wire (0.9mm dia annealed ) complete all as specified and directed.

150

-

-

... More
S&F welded steel wire fabric weight n exc 4 Kg/sqm complete all as specified and directed.

780

-

-

... More
Taking down cement plaster on bricks including raking out joints hacking for key scrubbing down with water etc.complete all as specified and directed.

1000

-

-

... More
M&L for 10mm thick cement plaster on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.

50

-

-

... More
M & L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, finished fair and even (upto two storey of building) complete all as specified and directed.

300

-

-

... More
M & L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces, mixed with liquid water proofing compound as per manufacturer's instructions, surfaces finished fair and even (upto two storey of building) complete all as specified and directed. Note:- Liquid WPC will be measured and paid separately.

400

-

-

... More
M & L for 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of wall finished even and smooth without using extra cement complete all as specified and directed.

250

-

-

... More
M & L for Acid/Alkali wash and drying of any existing efflorescence and leaving the wall to dry for min. 3 days and watch for any extra efflorescence. The surface to be washed with clean water and left to dry for 3 to 4 hours before application of further treatment complete all as specified and directed.

150

-

-

... More
Supplying and Applying , one component penetrative-cum-film forming interior waterproofing solution, with negative hydrostatic resistance upto 4 bar, with forced coverage of 350 ml per Sqm single coat using brush or roller, complete all as specified and directed.

250

-

-

... More
Supplying and Applying, two components acrylic polymer modified cementitious coating on new masonry surfaces devoid of plaster, with Hydrostatic resistance upto 5 bars with forced coverage of 1.75 Kg per Sqm in two coats using roller or brush with a gap of 4 to 6 hrs between the coats. The coats to be applied shall be perpendicular to each other complete all as specified and directed. Note : The Coverage is to be strictly maintained for film formation.

200

-

-

... More
M&L for preparation of new plastered surfaces and applying three coats of white wash as on ceiling surfaces complete all as specified and directed.

50

-

-

... More
M&L for preparation of new plastered surfaces and applying three coats of white wash as on wall surfaces complete all as specified and directed.

50

-

-

... More
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper on surfaces of wall over a coat of primer complete all as specified and directed.

200

-

-

... More
M&L for preparation of new plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.

700

-

-

... More
M&L for preparation of old plastered surfaces and applying one coat of white wash as on wall including removing/ brooming down or scraping down loose dirt by steel wire brushes etc complete all as specified and directed.

300

-

-

... More
All as per Item No 54.00 above but as on surface of ceiling complete all as specified and directed.

100

-

-

... More
M&L for preparation of old plastered surfaces including removing / brooming down or scraping down loose dirt by steel wire brushes etc, applying wall care putty where required for filling purpose of any depression /cavity etc and applying one coat of oil bound distemper of any colour on old surfaces of wall complete all as specified and directed.

500

-

-

... More
M&L for preparation of old plastered surfaces and applying one coat of cement based paint of approved shade on plastered surfaces or unplastered surface of wall including brooming down or scraping down loose dirt by steel wire brushes etc complete all as specified and directed.

870

-

-

... More
M&L for preparation of old wooden surfaces width or girth exc 10 cm and applying one coat of synthetic enamel paint complete all as specified and directed.

200

-

-

... More
M&L for preparation of old steel surfaces width or girth exc 10 cm and applying one coat of synthetic enamel paint complete all as specified and directed.

120

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.