If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Oct 2024
Closing Date1 Nov 2024
Tender Amount₹ 41,00,000
Costs
EMD
₹ 82,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677943_1Bid Award Id
ViewTender No
GE(I)/KAN/T-77 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.
57.59
-
-
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
4266
-
-
M&L for drilling manually in soft/loose/ hard soil under road, pavement hard standing for protection of GI pipe up to 80mm dia complete all as spfd and directed. Note Depth of bore shall not be more than 1 Mtr from ground level complete all as specified and directed.
30
-
-
Supply & laying in replacement of GI tubing of 80 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or pole incl fixing arrangement as directed, culvert etc of required length for cable protection complete all as specified and directed.
30
-
-
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.
360
-
-
All as per item No 8 above but HT 11 KV cable of size 120 Sqmm complete all as specified and directed.
280
-
-
All as per item No 8 above but HT 11 KV cable of size 185 Sqmm complete all as specified and directed.
150
-
-
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
4
-
-
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
4
-
-
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sq mm complete all as specified and directed.
3
-
-
Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
2
-
-
Supply and fix cable straight through jointing kit for 11 KV (Earthed) grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
20
-
-
Supply and fix cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
20
-
-
S & F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 6 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed.
250
-
-
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable complete all as specified and directed.. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
10
-
-
Cable route indicator made out of RCC patties size 15cm x 15cm x 75cm in lengths duly engraved with (HT CABLE 11 KV) with projection of 45 cm above ground level and 30 cm grouted in foundation including PCC foundation, RCC shall be painted with yellow colour above ground and HT CABLE 11 KV will be marked with Red Colour Paint complete all as specified and directed.
60
-
-
Dismantling & taking down old, deteriorated, switch air break and S & F with new 11 kV Isolator Double Stack, Horizontal Type, 400 Amp, each pole consist of galvanised steel base, HT insulators as per IS, non ferrous knife and spring loaded contact, arcing horns of adequate section to break the magnetizing current, including horizontal G.I. pipe adequate length for phase separation, adequate length of G.I. pipe of 32 mm for operation from ground level and operating handle complete in both OFF and ON position, jumpers with suitable conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontally mounting, supplied and fixed in repairs, complete all as specified and directed.
4
-
-
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and directed.
(Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.
(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets
over 10 kg each to be measured under 'Structural Steel')
400
-
-
S&F mild steel galvanised chain fencing made of galvanised steel wire of not less than 2.5 mm of fixed iron rails to flat iron rails with RCC/ angle iron post complete all as specified and directed.
250
-
-
Servicing / Calibration to 33 / 11 KV HT VCB / SF-6/LBS/RMU complete including the following (a) Taking out 33 / 11 KV HT VCB / LBS/RMU of 400 /800 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB / SF6 trolley including opening the VCB / SF6 & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where reqd complete all as specified and directed.
(b) Taking out relay set of any make from HT 33 / 11 KV VCB / SF6 panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only. Note : Minor spares if required shall deems to be included with the above job.
15
-
-
Supply only shunt trip coil assembly suitable for HT, SF6 / VCB, operating on 30 / 110 volt system and testing complete all as specified and directed.
6
-
-
Supply and fixing closing / tripping coil operated on 110 / 30 volt system as per sample suitable for working of relay of HT SF6 / VCB complete all as specified and directed.
4
-
-
Supply and fixing only fabricated gears as required for spring charger of VCBs as per sample complete all as specified and directed.
3
-
-
S&F in replacement of vaccum circuit bottle as per existing make complete all as specified and directed.
9
-
-
S&F in replacement of feeder protection relay for 33/ 11 KV incomer feeder panel complete all as specified and directed.
2
-
-
S&F (in replacement) indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed.
40
-
-
Dismantling and taking out unserviceable DO fuse unit and supply and replace of DO fuse unit complete with insulators with metal fitting on both ends unit 11 KV complete all as specified and directed.
4
-
-
Supply & Fixing in replacement Pin type insulator porcelain, vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut, 100mm high & 65mm dia suitable for 11 KV grade working pressure fixed incl dismantling old complete all as specified and directed.
15
-
-
Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines complete all as specified & directed.
1
-
-
S&F Aluminium conductor of any size with GI/steel reinforced complete all as specified and directed.
1
-
-
Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site/store and shifting/refixing in other location under GE Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.
5
-
-
M&L for disconnecting electrically and dismantling of LT Panel/RMU/ LBS at site and shifting/ refixing in other location and making all electrical connections complete all as specified and directed. Note : Cost of T&P / transportation is included in this item)
2
-
-
Dismantlling top cover of transformer 11/.440 KV of capacity upto 750 KVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed.
Note - spare parts will be measured and paid separately
4
-
-
Dismantling old u/s HT 11 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 KVA complete all as specified and directed.
8
-
-
All as per item No 37 above but exceeding 250 KVA not exceeding 750 KVA complete all as specified and directed.
9
-
-
Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 KVA complete all as specified and directed.
10
-
-
All as per item No 39 above but exceeding 250 KVA but not exceeding 750 KVA complete all as specified and directed.
10
-
-
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket/seal, or Repairs to the leaks of transformer body/fins, by welding/brazing etc complete all as specified and directed.
6
-
-
M&L for taking out old burnt winding and rewinding of HT/LT coil of any type, capacity and make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required complete all as specified and directed.
455
-
-
S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 750 KVA complete all as specified and directed.
4
-
-
M&L for replacement and full fill up fresh silica gel in assembly at site complete all as specified and directed.
3
-
-
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 33/11/6.6/0.433 KV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed.
12
-
-
Disconnecting electrically, open the cover of transformer any type/size and filteration and dehydration of Transformer oil for 33/11 / 6.6 / 0.433 KV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.
1500
-
-
Cleaning of transformer of size 63 KVA to 315 KVA outer surface suitable for painting and painting with two coat of synthetic enamel paint by spray machine of light grey colour or as directed including transformer accessories such as radiator, conservator tank, marshalling box and incl writing SM No/size/ feeder name etc all as specified and directed.
6
-
-
All as per item No 47 above but of transformer of size 315 KVA to 750 KVA complete all as specified and directed.
6
-
-
M&L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved color complete all as specified and directed.
25
-
-
Earthing complete with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified & directed.
10
-
-
M&L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictldispose them at suitable place complete all as specified and directed.
30
-
-
Removal of unwanted vegetation/bushes/small plants/ shrubs complete inside/outside the installations all around and surface excavation not exceeding 15 cm depth levelling the ground and removing the excavated material to a distance exceeding 50 Mtr complete all as specified and directed.
6
-
-
M&L for coarse aggregate not less than 40 mm graded nominal size without any vegetation or chemical incl levelling spreading all around complete all as specified and directed.
30
-
-
S&F in replacement of HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed.
4
-
-
Transportation of Transformer from site E/M yard to workshop for repairing and from workshop to site E/M yard after repair etc of capacity upto 750 KVA complete all as specified and directed by. NOTE : The rate deemed to be included of transportation charges.
4
-
-
Material and labour for dismantling of complete HV/LV coils of transformer upto 750 KVA (33/11/6.6/0.433 KV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed.
Note : 1. Rewinding of defective HV / LV Coils shall be measured and paid seperately. 2. The rate deemed to be included of all tools and plants.
2
-
-
M & L Installation, commissioning, testing of transformer up to 750 KVA by connecting all HT 33/11/6.6/0.433 KV connections, earthing connections, control cables for various protections, indications, metering, connection and bezels connections and testing complete all as specified and directed.
2
-
-
S&F in replacement of fully retroreflective sign boards of cut to sizes/shape having writing back ground made out of 18 SWG MS Sheet duly painted with two coats of synthetic enamel paint over a coat of primer including marking/writing letters, road sign any type with radium tape in different colours, duly mounted on angle iron frame 45mm X 45mm and 5mm thick fixed with nut, bolt, washer and welding (height as per site requirement) etc and painting with two coats of black synthetic enamel paint over a coat primer including all necessary earth work and PCC for foundation complete all as specified and directed.
4
-
-
M&L for making for LBS operating handle and compartment key as per existing make of LBS complete all as specified & directed.
9
-
-
S&F in replacement of battery 12 volt 12 AH complete all as specified & directed.
11
-
-
S&F in replacement of battery bank consisting of 15 battery having cell capacity 100 Ah 2 volt complete all as specified & directed.
1
-
-
S&F in replacement of CT having ratio 200-100/1-1A Burden 7.5 VA /7.5 VA accuracy class 1/5P10 Complete all as specified & directed.
1
-
-
M&L for Open the cover of transformer any type/size on site and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 60 KV when tested at 4mm gap complete all as specified and directed.
800
-
-