Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date2 Sep 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 20,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669814_1Tender No
AGE(I)/FAT/ET-18 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L cleaning of existing septic tank and sewage well by closing the existing sewage system at last man hole and providing temporary Katcha drain for flow of sewage water. Removing man hole cover and dewatering the liquid waste by mechanical pumping. Removing the solid sludge by manually or by mechanical system up to the bottom of septic tanks and sewage well at any size incl depositing the solid sludge in the pit providing by digging in near by septic tank of appropriate size. Covering the pit by natural earth obtained from excavation after filling the solid sludge and making the good completely hygienic .Opening the man hole after cleaning of septic tank and relaying the man hole cover complete work to be executed to the entire satisfaction of Engr –in-charge and as directed at site.
200
-
-
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth complete all as specified and directed
1500
-
-
Material and labour for Construction of Soakage well of size 2.4 m dia. x 3.0 m deep including excavation in any type of soil, foundation in plain cement concrete 1:3:6, walls of honey combed masonry with top ring of reinforced cement concrete of nominal mix type B-1 (1:2:4) using 20 mm graded stone broken aggregate complete filled with brick bats, complete all as specified and directed by Engineer-in-charge and as shown on drawing no. CELZ/TD/576 dated 16 Jun 1989 ( for reference purpose only).
Note :-(a) The above referred drawing can be seen in the office of AGE(I) during working hours.
1
-
-
Demolition and breaking up 150mm bore drain pipes (salt glazed ware ) in cement mortar and taking out from trenches all as specified and directed by Engineer - in – Charge.
150
-
-
M&L for PCC (1:4:8) type C2 using 40mm graded stone aggregate crushed stone aggregate as in bed SGSW pipe 150 mm bore and haunching against the sides of pipes after laying and testing complete.
150
-
-
M&L for 150mm bore internal dia salt glazed stone ware pipe grade ‘A’ conforming to IS laid in trenches, on concrete bed to required slope, jointed and tested complete all as specified and directed.
150
-
-
M& L for Cutting into existing manholes for connecting new drains, for 150 mm dia SGSW pipe making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4 ) type B1 using 20mm graded crushed stone aggregate finished smooth and reforming benching as required complete all as specified and directed.
5
-
-
Excavation in trenches in soft /loose soil n.exc 1.50 m deep and 1.50m wide or shafts, manhole etc n.exc 10 Sqm on plan and n.exc 1.50m deep and getting out complete all as specified and directed.
35
-
-
Returning, filling in trenches, including spreading, leveling watering and wall ramming in layers each n.exc 25cm in soft/loose soil complete all as specified.
31.5
-
-
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified.
3.5
-
-
Demolition of brick work built in cement mortar incl quoins and arches all as specified and directed
10
-
-
M&L for brick work built in cement mortar (1:4) using sub class ‘B’ bricks (old size) straight or curved in plan, exc 6.00 m mean radius complete all as specified.
10
-
-
M & L for rendering 15 mm thick to manhole brickwork in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
50
-
-
M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping bands and benching of manholes etc including slightly rounded or chamfered angles including necessary form work complete all as specified.
0.5
-
-
Demolition of RCC of any description and in any position complete all as specified and directed.
10
-
-
M&L for pre-cast reinforced cement concrete as in chajja, shelves, landings, cover slabs (1:2:4) type B1 using 20mm graded stone aggregate complete after placing in position over septic tanks/ manhole covers complete all as specified and directed .
8
-
-
M&L for RCC 1:2:4 type B-1 using 20mm graded aggregate slab supported on walls ,columns in floors, roofs landings, balconies canopies deck slab and in the shelves and the like, complete all as specified and directed.
2
-
-
Use and waste of Form work to sides/soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200cm thick (Horizontal or sloping) flat surface complete all as specified and directed.
30
-
-
M&L for MS TMT bars 6mm to 8mm dia and cut to length, bent to shape including cranking bending, and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified.
624
-
-
M&L for MS TMT bars 10 mm dia and over cut to length, bent to shape including cranking bending, and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified.
156
-
-
S & F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, white, with inlet, ball valve, float valve and handle including brackets, flushing pipe complete all as specified and directed.
10
-
-
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc, Plastic water closet seat white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, Health faucet (ABS Body) brass chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
5
-
-
Supply and fixing in repairs vitreous China squatting pan of pattern(Orrissa pattern) size 580mm x 440 mm white with integral foot rests n including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed.
10
-
-
Dismantiling Floor, hearth or Wall tiling including cement mortar bedding (but not baking), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
55
-
-
M&L for non skid ceramic any coloured/printed tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor of shade & designed as approved by AGE(I), set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over and including 15 mm thick screed bed in cement mortar (1:4) in floorse etc complete all as specified and directed.
45
-
-
M & L for Glazed ceramic tiles in vertical surface 450 x 300 x 7mm thick coloured tiles, set and jointed in neat cement slurry and pointed in white or colour cement to match, over and inlcuding 10 mm thick rendering on fair faces of concrete surface of verticle in CM (1:3) finished even and fair without using extra cement, shade & design of tile as approved by /AGE (I) etc compete all as specified and directed.
10
-
-
Demolition and breaking up drain pipes 75/100/150 mm dia (salit glazed ware, AC or reinforced concrete) set in cement Mortar upto triple story complete all as specified and directed.
325
-
-
S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls including fixing with new clamps complete all as specified and directed
200
-
-
S&F 75 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls including fixing with new clamps complete all as specified and directed.
125
-
-
S&F 110 mm bore PVC(SWR) bend/Tee/Y any radius complete all as specified and directed.
25
-
-
S&F 75 mm bore PVC(SWR) bend /Tee/Y any radius complete all as specified and directed.
10
-
-
Cleaning of PVC water tank exc 250 ltr but not exc 500 ltr and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes complete all as specified and directed
50
-
-
Cleaning of PVC water tank exc 500 ltr but not exc 1000 ltr and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes complete all as specified and directed
10
-
-