Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date4 May 2023
Closing Date1 Jun 2023
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Summary

8250 Maint/repair Of Stp And Sewage Pump Installation Under Ge East Bareilly.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl item No.1 here-in-before but STP JRC of Capacity01 MLD.

1

-

-

... More
Note for item no. 1 to 4 :- (a) The followings are deemed to be included in the rate quoted. (i) The disposal of accumulated/deposited sludge after drying out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the STP. (ii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at STP in order to complete the work in max 02 days. (iii) Cutting and rewelding of supporting MS frame structure. (b) Replacement of unsv rusted portion of supporting MS frame structure. The cost of MS frame will be measured and paid separately

-

-

-

... More
Dewatering and pumping out of existing accumulated sewage from Chlorine Contact Tank and Treated Water Tank at STP 80 OR of capacity of 90 MLD by manullay or using external sewage disposal pump sets to near by sewage disposal drain and cleaning of tanks by scrapping with wire brush or any other means on walls and bottom of tank and removing the sludge / silt / sand / fungus etc deposited inside the sumps / tanks with buckets and depositing where directed, followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external walls complete all as specified and directed. Note :- (i) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the STP cost of which shall be deemed to enclusive in the quoted rate and nothing extra shall be paid on this account. (ii) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in STP. (iii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at STP in order to complete the work in max 02 days.

1

-

-

... More
All as per Srl item No.6 here-in-before but STP MH OR of Capacity of 150 KLD

1

-

-

... More
All as per Srl item No.6 here-in-before but STP JRC of Capacity 01 MLD

1

-

-

... More
All as per Srl item No.6 here-in-before but STP 42 Map of Capacity 461 KLD

1

-

-

... More
Dewatering and pumping out of existing accumulated Sludge and Water from Sludge Holding Tank at STP 80 ORs of Capacity of 90 KLD by using external sewage disposal pump sets to near by sewage disposal drain and cleaning of tanks by scrapping with wire brush or any other means on walls and bottom of tank and removing the sludge / silt / sand / fungus etc deposited inside the sumps / tanks with buckets and depositing where directed, followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external walls complete all as specified and directed. Note:- (i) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the STP cost of which shall be deemed to enclusive in the quoted rate and nothing extra shall be paid on this account. (ii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at STP in order to complete the work in max 02 days. (iii) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in STP.

1

-

-

... More
All as per Srl item No.10 here-in-before but STP MH OR of Capacity of 150 KLD

1

-

-

... More
All as per Srl item No. 10 here-in-before but STP JRC of Capacity 01 MLD

1

-

-

... More
All as per Srl item No. 10 here-in-before but STP 42 Map of Capacity 461 KLD

1

-

-

... More
Dewatering and pumping out of existing accumulated Sludge and mud including cutting of grass, bushes, plant growth from Sludge Drying Beds at STP under GE East bareilly by using external sewage disposal pump sets to near by sewage disposal drain and cleaning of tanks by scrapping with wire brush or any other means on walls and bottom of tank and removing the sludge / silt / sand / fungus etc deposited inside the sumps / tanks with buckets and depositing where directed, followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external walls complete all as specified and directed. Note:-(i) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to adistance exceeding 1.5 KM and not exceeding 5.00 KM from the STP cost of which shall be deemed to enclusive in the quoted rate and nothing extra shall be paid on this account. (ii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at STP in order to complete the work in max 02 days. (iii) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in STP. (iv) Cleaning of sludge transfer line from tube settler tank to Sludge holding tank

4

-

-

... More
Supply and fix in replacement of Glass tube type Air Rotameter including taking down existing unserviceable Air Rotameter of any description complete all as specified and directed. Make: Flowstar / Microflow / Aster

3

-

-

... More
M&L for replacement of Unsv MBBR Media from the tank and supply of filling Fresh media of MBBR Media in the main reactor as specified of existing /suitable Make with the following specificatios:- Effective surface area of media Approx - 400 Sqm/Cum (b) Mesdia ht Approx - 15/10 mm (c)Media dia Approx- 22 mm (d) Weight per unit surface area approx -22 mm (e) Voidage - 093 gm/Cucm (g) Media fill Range - 25-55% of volume

20

-

-

... More
S&F in replacement, heavy duty cloth strips of filter press as per existing frame of capacity of 01 MLD and complete over hauling of filter press including testing complete all as specified and directed.

50

-

-

... More
S&F in replacement, heavy duty cloth strips of filter press as per existing frame of capacity of 150KLD and complete over hauling of filter press including testing complete all as specified and directed.

40

-

-

... More
Supply and fixed in replacement, connecting and testing of (non return valve ISI - 5312) CI of 150 mm sizes bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with joint with rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement of CI Butterfly valve of following size as per IS 13095, PN 16, wafer type without lugs, suitable for clamping between flanges as per ANSI B 16.1 CI-125, including flanges, fittings, gasket, nuts, bolts, washers etc. including taking up / down of existing unserviceable butterfly valve of any description complete of size 50 mm all as specified and directed. Make : Leader / Crawley / Audco / L&T / Zoloto

10

-

-

... More
All as per Srl item No.20 here-in-before but 100 mm

8

-

-

... More
All as per Srl item No.20 here-in-before but 150 mm

2

-

-

... More
Material and labour for M.S. Black Pipe of size 80mm bore, plain end as per IS:1239 (I), nominal bore, heavy Grade ('C' class) with all fittings like elnow, tee reducer, flange nut bolt with washer including cutting, welding and joining etc as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including taking up / down of existing unserviceable pipe of any description complete all as specified and directed. Make : Tata / Jindal / Prakash Surya. Note:- fixing of pipe line will be carried out on wall or floor and cost of the same will be deemed to be included in tthe rate quoted however for the pipe line laid under ground by digging trench will be paid saperately.

100

-

-

... More
All as per Srl item No.23 here-in-before but 100 mm

35

-

-

... More
All as per Srl item No.23 here-in-before but 150 mm

25

-

-

... More
All as per Srl item No.23 here-in-before but 50 mm mm

125

-

-

... More
M&L for Structure Steel Work, made out of god quality-A Rolled Mild Steel Chaneel, Angle or Tee Sections, MS Sheet with hinges & looking arrangements et. Cut to shape / ordinary length, drilled and counter sunk for screws / Bolts, including bending and welding duly painted with 2 coats of anticorrosive synthetic enamel paint over a coat of Zinc Chromate as in framed work with MS Sheet cover complete all as specified and directed.

250

-

-

... More
M&L for complete overhauling and repairing of multi-grade sand filter with replacement of filter media as per existing and activated carbon filter media including replacement of filter media including other connected assessories as required at site of STP JRC capacity of 1 MLD including testing and wire mesh size shuold as per existing, colour in Black, Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness (abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed

1

-

-

... More
M&L for complete overhauling and repairing of multi-grade sand filter with replacement of filter media as per existing and activated carbon filter media including replacement of filter media including other connected assessories as required at site of STP MH capacity of 150 KLD including testing and wire mesh size shuold as per existing, colour in Black, Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness (abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed

1

-

-

... More
M&L for complete overhauling and repairing of multi-grade sand filter with replacement of filter media as per existing and activated carbon filter media including replacement of filter media including other connected assessories as required at site of STP 80 ORs capacity of 90 KLD including testing and wire mesh size shuold as per existing, colour in Black, Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness (abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed

1

-

-

... More
M&L for complete overhauling and repairing of multigrade sand filter with replacement of filter media as per existing and activated carbon filter media including replacement of filter media including other connected assessories as required at site of STP 42 Map of capacity of 461 KLD including testing and wire mesh size shuold as per existing, colour in Black, Grade of GAC 8x30 and bulk density approx 450kg / cum, Hardness (abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed

1

-

-

... More
M&L for cleaning, scrapping out side of vessel properly including painting with one coat zinc chrome primer & two coats of best quality synthetic enamel paint etc. complete all as specified and directed

4

-

-

... More
M&L for servicing / maintenance of air compressor machine 415 volts 50 Hz motor complete with cleaning of air tank incl replacement of all defective parts and lubricating oil complete all as specified and directed. Note:- Spare parts will be measured and paid under relevant item separately. All minor consumables incl T&P and Tpt required shall be deemed as included in the rates quoted.

3

-

-

... More
All as per Srl item No. 33 here-in-before but Cap 515M3/Hr with 10 HP motor.

3

-

-

... More
Supply only rotor roller machineing and alignment complete all as specified and directed.

3

-

-

... More
Supply only all packing for casing complete all as specified and directed.

15

-

-

... More
Supply only air filter complete all as specified and directed.

6

-

-

... More
Supply only 'O'-Ring complete all as specified and directed.

3

-

-

... More
Supply only oil seal complete all as specified and directed.

25

-

-

... More
Supply only Gear wheel pair complete all as specified and directed.

3

-

-

... More
Supply only lock nut complete all as specified and directed.

3

-

-

... More
Supply only lock washer complete all as specified and directed.

2

-

-

... More
Supply only ball bearing No. 2211 complete all as specified and directed.

2

-

-

... More
Supply only ball bearing No. 3211 complete all as specified and directed.

3

-

-

... More
Supply only ball bearing No. 6211 complete all as specified and directed.

2

-

-

... More
Supply only V belt complete all as specified and directed. Make Fainiyar

2

-

-

... More
M&L removing the submersbile pump set from existing position, Shifting to authorised workshop for repair work, dismantle/open, removing the burnt winding, cleaning of rotor / stator, re-winding the motor with F Class insulation super enameled copper wire of size equivalent to the original winding incl insulate packing materials, Varnishing, Drying incl replacement of both water seal, compound, both bearing, fill with new lub oil etc. re-assembling the pump set, installing back to the original position, testing and commissioning on full load for 4 hrs continuous running for the motor cap of motor upto 5 HP complete all as specified and directed. Note :- Spares parts will be measured and paid under relevant items separately all minor consumable/Eqpt/Tpt required shall be deemed as included in the rates quoted.

1

-

-

... More
All as per Srl item No. 47 here-in-before but more than 7.5 HP and upto 10 HP.

1

-

-

... More
All as per Ser item No. 47 here-in-before but more than 11 HP and upto 15 HP.

4

-

-

... More
M&L for removing the submersbile pump set from existing position, Shifting to authorised workshop for repair work, overhauling and servicing of submersible pump set with motor incl replacement of unsv nuts, bolts & washers, seals, packing, opening of delivery casing volute for checking of non clog type impeller checking & replacement of stuffing box unit seals and match seal housing /casing cover for checking/filling of suitable grade lubricating oil upto required, checking of seat & replacement of seat ring, checking for smoothness of motor runnning and clearance between impeller and casing ring and casing cover, greasing of flower bearing of pump set, incl cleaning of 3 phase electric submersible squirrel cage induction motor in water tight housing testing it for its water tightness by air for its joints incl replacements of unsv parts as required re-assembling the pump set, installing back to the original position testing and commissioning on full load for 4 hrs continuous running for the motor cap of motor upto 5 HP complete all as specified and directed. Note :- Spares parts will be measured and paid under relevant items separately all minor consumable/Eqpt/Tpt required shall be deemed as included in the rates quoted

1

-

-

... More
All as per Srl item No. 50 here-in-before but more than 5 HP and upto 10 HP.

1

-

-

... More
All as per Srl item No. 50 here-in-before but more than 10 HP and upto 15 HP.

4

-

-

... More
Supply only Non Clog impeller suitable for and upto 5 HP submersible pump set complete all as specified and directed.

1

-

-

... More
All as per Srl item No. 53 here-in-before but more than 5 HP and upto 10HP.

1

-

-

... More
All as per Srl item No. 53 here-in-before but more than 10 HP and upto 15 HP.

2

-

-

... More
Supply only upper/lower or back to back roller or Ball bearing suitable for and 3 HP to 15 HP non clog submersible pump set complete all as specified and directed. Make FAG/SKF

3

-

-

... More
Supply only Mechinical seal carbonite 25 mm suitable for and upto 3 Hp to 5 HP non clog submersible pump set complete all as specified and directed

1

-

-

... More
Supply only Mechinical seal carbonite 33 mm suitable for and 5HP to 20 HP non clog submersible pump set complete all as specified and directed

3

-

-

... More
Supply only oil seal 2 HP to 20 HP non clog submersible pump set complete all as specified and directed.

2

-

-

... More
M&L for dismantling and removing the motor of the mono block / coupled Pump set or Air Compressor from existing position, Shifting to authorized workshop for the repair work, removing the burnt wirding cleaning rotor/stator, re-winding the motor with super enameled copper wire of size equivalent to the original winding incl insulate packing materials, Varnishing, Drying etc incl installing back to the original position, testing and commissioning on full load for 4 hrs continuous running for the motor cap of motor upto 5 HP complete all as specified and directed.

3

-

-

... More
All as per Srl item No. 60 here-in-before but more than 5 HP and 10 HP.

5

-

-

... More
All as per Srl item No. 60 here-in-before but more than 10 HP and upto 20 HP.

3

-

-

... More
M&L for Dismantling and removing the mono block / Coupled pump set from the existing position after disconnecting the inlet/outlet pipe connections, disconnecting the electric supply cables and transporting to repair work shop complete, opening the pump side, servicing the pump set including cleaning the shaft including replacement of worn out bearing, bushes, check nut, shaft sleeves etc. and installing back to the original position, testing and commissioning on full load for 4 hrs continuous running for the capacity of pump upto 5HP complete all as specified and directed. Note: Spares parts will be measured and paid under relevent item separately. All minor consumables / Eqpt /Tpt required shall be deemed as included in the rates quoted.

3

-

-

... More
All as per Srl item No. 63 here-in-before but more than 5HP upto 10HP

2

-

-

... More
All as per Srl item No. 63 here-in-before but more than 10HP upto 20 HP

2

-

-

... More
Supply only Ball bearing of suitable size for and upto 5 HP mono block / Coupled pump set. Make: SKF / NBC complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 67 here-in-before but more than 5HP upto 10 HP

2

-

-

... More
All as per Srl item No. 67 here-in-before but more than 10 HP upto 20 HP

2

-

-

... More
Supply only brass bush of suitable size for and upto 5 HP mono block / Coupled pump set complete all as specified and directed.

2

-

-

... More
All as per Srl item No 69 here-in-before but more than 5 HP upto 10 HP

2

-

-

... More
All as per Srl item No. 69 here-in-before but more than 10 HP upto 20 HP

2

-

-

... More
Supply only new impeller of suitable size for and upto 5 HP mono block / Coupled pump set complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 72 here-in-before but more than 5 HP upto 10 HP

2

-

-

... More
All as per Srl item No. 72 here-in-before but more than 10 HP upto 20 HP

2

-

-

... More
M & L in repairs for Gland packing of thickness upto 14mm complete all as specified and directed. Make: Spitmaan Graflon / Charminar / Champion

50

-

-

... More
M&L in repairs Air Cobe, suitable size for mono block / Coupled pump set, made out of brass, as per site complete all as specified and directed.

5

-

-

... More
M&L for cleaning and desiIting the sewage intermediate well of any capacity, dewatering the complete well, removing all the deposited sludge, soil and other material from the well including bailing / pumping out muddy water from the well by manually or by providing suitable pump sets from bottom level of well, scrapping out the scales / deposits from inner surface of the well throughly, washing with bleaching powder and soda ash, cleaning / bailing out settled materials completely by any means and removing sludge to a distance up to 3 km out side of defence land limit and dispose off in low lying area including dewatering as required including writing 'Tank cleaned on ......(date) with 10 cm size white letter on black surface by engaging skilled artist using first quality synthetic enamel paint complete all as specified and directed. Note:-(i) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in Lift well.(ii) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the Lift well cost of which shall be deemed to inclusive in the quoted rate and nothing extra shall be paid on this account. (iii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at lift well in order to complete the work at the earliest.

5

-

-

... More
All as per Srl item No 77 here-in-before but Collection tank of STP JRC

2

-

-

... More
All as per Srl item No 77 here-in-before but Collection tank of STP MH

1

-

-

... More
All as per Srl item No 77 here-in-before but collection tank of STP 80 Ors

2

-

-

... More
All as per Srl item No 77 here-in-before but collection tank of STP 42 Map

1

-

-

... More
M&L for preparing the surface by scrapping the old painting and removing the grease, oil, dirt, algae etc. Painting of outer surfaces of MS pipes with one coat of black Japan paint over a coat of Zync Chromate complete incl its MS supports / clamps / nuts / bolts and marking / writing flow arrows and name with white paint by skilled painter All as directed of 150 - 200 mm dia complete all as specified and directed.

80

-

-

... More
All as per Srl item No. 82 here-in-before but 80 to 100 mm dia

50

-

-

... More
All as per Srl item No.82 here-in-before but 50 mm dia

50

-

-

... More
All as per Srl item No. 82 here-in-before but 25 mm dia

40

-

-

... More
S&F in repair and connect, MCB SP 6 to 32 A, AC, 240V, ISI Marked complete all as specified and directed.

2

-

-

... More
S&F in repair and connect, Isolator DP, 40A, AC, 240V, ISI Marked complete all as specified and directed.

2

-

-

... More
S&F in repair and connect, Isolator 4P, 63A, AC, 415V, ISI Marked complete all as specified and directed.

2

-

-

... More
S&F in repairs and connect, Single Phase Preventer suitable for motor protection complete all as specified and directed.

5

-

-

... More
S&F in repairs and connect, NO-NC auxiliary contact block suitable for 10 to 25A 3 phase contactors complete all as specified and directed..

2

-

-

... More
S&F in repairs and connect, NO-NC auxiliary contact block suitable for 32 to 60A 3 phase complete all as specified and directed.

2

-

-

... More
S&F in repairs and connect, over load Relay 3 Phase, 415V, 25 Amp to 40 Amp complete all as specified and directed.

2

-

-

... More
S&F in repairs and connect, DOL starter suitable 2 to 7.5HP motor, 3 Phase, 415 V, with 1Ø preventer and thermal relays complete all as specified and directed.

2

-

-

... More
All as per Srl item No 93 here-in-before but for more than 7.5 to 15HP

2

-

-

... More
S&F in repairs, fully automatic star delta motor starter suitable for 15/ 20 HP pumpset, 3 phase, 415 V with relay of suitable range incl enclosure complete all as specified and directed. Make : L&T, model No. ML- 4FASD or equivalent of C&S / Legrand complete all as specified and directed.

1

-

-

... More
S&F in repairs, 3 Pole MCCB 25 -100 Amp, 50 Hz, 415 V with rupturing capacity 18KA with Thermal - Magnetic Release. complete all as specified and directed.

1

-

-

... More
All as per Srl item No 96 here-in-before but 4 Pole 100-200Amps. 25KA

1

-

-

... More
S&F in repairs, testing Volt meter 0-500 Volts complete all as specified and directed. Make: AE/ Rishab/Meco/Enercon.

1

-

-

... More
S&F in repairs, Pressure Gauge, 100/80 mm dia, 0 - 100 lb/Sq inch pressure rating complete all as specified and directed. Make: Lub / Meco / H Guru / Pfizer

1

-

-

... More
Supply and fixing of non clog sewage submersible pump set, 2HP, 1Ø, AC, 240V, complete all as specified and directed. Make: CG/ Kirloskar / KSB

1

-

-

... More
Supply only DWPE (Dewatering Polyelectrolyte) powder, pack of 10/25Kg in polythene bags / HDPE drums complete all as specified and directed

500

-

-

... More
Supply only AQUAFIT-CHLORINE-65%-70% (Calcium based granular disinfectant for water treatment, more stable than Chlorine gas, and stronger than Bleaching powder, and sodium Hypochlorite) in 45 kg Drums complete all as specified and directed. Make : Sree Rayalaseema HI-Strtength HYPO LTD .

1400

-

-

... More
Supply only Calcium Hydro-Oxide (Lime, 80-85%) in Powder form as pH Booster for STP water, packing in 40 Kg Packs complete all as specified and directed.

400

-

-

... More
Supply only Ortho Tolidin solution for testing of dissolved chlorine in water complete all as specified and directed

3

-

-

... More
Supply only Chlorination testing glass test Tube kit complete all as specified and directed

4

-

-

... More
Supply only Alum Ferric (Grade-4) (best quality as per sample) for purification of water (containing lead (as PB) 30 ppm Max and arsenic 6 ppm Max) confirming to IS-299/2012 (Revised) as amended upto date complete all as specified and ddirected by Engineer-in-Charge. (Note :- The Alumino Ferric Sulphate shall be supplied in superior quality bricks (slabs) as per IS specifications. Manufacturers Name/trade mark shall be engraved on each brick (slab) in addition to marking of relavant clause of IS specification).

400

-

-

... More
M&L for replacement filteration media of six drying bed with ten layer of sand gravals and stone gravels as per existing all as specified and directed

10

-

-

... More
Supply only bacteria culture areobic in 30 Kg of drum complete all as specified and directed.

500

-

-

... More
Supply only DAP fertiliser for day to day use in sewage treatment plant complete all as specified and directed.

300

-

-

... More
Supply only molasses for day to day use in Sewage treatment plant complete all as specified and directed.

400

-

-

... More
Supply only PAC (Poly Aluminium Chloride AC 1005 in organic soluable Polymer Powder packed in 25 Kg Poly bags completed all as specified and directed.

250

-

-

... More
M&L for testing of treated sewage water from out let of chlorine contact tank once in every three months from NABL accredited authorized lab as per IS 3025 for recording essential parameters such as BOD, COD, PH, suspended solids and total dissolved solids complete for STP JRC , 80 OR, MH and 42 Map all as specified & directed.

8

-

-

... More
Supply only compressor oil 320 grade complete for top up oil level all as specified and directed .

5

-

-

... More
Supply and fix in replacement u/s selector switch complete 230 volt complete all as specified and as directed. Make L&T/Kaycee

1

-

-

... More
Supply & fix in repair push button switch with mounting adaptor complete 230 volt complete all as specified and as directed. Make-L & T/Kaycee./BCH

2

-

-

... More
M&L for cleaning panel bd busbar and de carbounising of panel board and replacement of unsv parts including wiring and testing complete all as specified and as directed.

1

-

-

... More
M&L for taking out unserviceable Air diffuser and replacement with new one air diffuser complete as per existing all as spefified and directed

2

-

-

... More
M&L for complete overhauling and repairing of cake formation Machine and air Compressor of capacity 2 HP to 3 HP and all the connection of chemical mixer including other connected assessories as required at site for STP JRC Capacity of 1 MLD as specified and directed. Note:- 1. Payment will be made after testing of forming of cake

1

-

-

... More
Supply and fixing of Filter press Plate as per existing size in Cake formation machine complete all as specified and directed

2

-

-

... More
Supplying and fixing in repair Switch Gear Change over of 400 Amps 3 Pole 415 volts complete all as specified and directed

1

-

-

... More
Supplying and fixing Contactor 50 Amps 220 Volts all as specified and directed

1

-

-

... More
Supplying and fixing in repair single phase preventor all as specified and directed

5

-

-

... More
M&L for Disconnection flange of MS pipe and replacement of rubber packing to arrest the leakage of 50mm to 100 mm all as specified and directed

5

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mmnominal cross section inservice connections of 3 core of 10 sqmm stranded conductor type.

100

-

-

... More
M&L for Cleaning of sweeping, mooping, cleaning oil and grease chamber and and the open area of STP JRC and furniture yard STP including disinfection of room as well as cleaning of installed machinary at both STP's and Cleaning / Cutting of bushes of STP Drying Bed, open drain area and keep maintained from 0900 Hrs to 1700 hrs daily complete all as specified and directed. Note for item No. 125 to 127:- (a )The contractor shall keep the following aspect in mind while quoting unit rates in item above (a)The contractor shall be responsible for safety of worker and also upkeep of installation safe as per MES standard . (b) Contractor has been binded to strictly maintain cleaning as mentioned above at STPs otherwise, there shall be penalty imposed of 500/day from contractor payment. (c) The contractor will be responsible to provide a proper dress code to worker and also provide all safetly.

180

-

-

... More
M&L for Cleaning of sweeping, mooping, cleaning oil and grease chamber and and the open area of STP Lal phatak and STP 80 Ors including disinfection of room as well as cleaning of installed machinary at both STP's and Cleaning / Cutting of bushes of STP Drying Bed, open drain area and keep maintained from 0900 Hrs to 1700 hrs daily complete all as specified and directed.

180

-

-

... More
M&L for Cleaning of sweeping, mooping, cleaning oil and grease chamber and and the open area of STP Lal phatak and STP 80 Ors including disinfection of room as well as cleaning of installed machinary at both STP"s and Cleaning/Cutting of bushes of STP Drying Bed and open drain area and keep maintained from 0900 Hrs to 1700 hrs daily complete all as specified and directed.

180

-

-

... More
M&L for Cleaning of sweeping, mooping, cleaning oil and grease chamber and and the open area of STP Lal phatak and STP 42 Map including disinfection of room as well as cleaning of installed machinary at both STP"s and Cleaning/Cutting of bushes of STP Drying Bed and open drain area and keep maintained from 0900 Hrs to 1700 hrs daily complete all as specified and directed.

180

-

-

... More
Taking out of booster pump from foundation/electric motor manually or machnically and transporting to workshop for repair and back to site incl reinstallation refixing and reconnecting after necessary repair complete all as specified and as directed. Note :- Repair/Replacement of unserviceable parts will be measured and paid under relevent items

2

-

-

... More
S&F in repair of Star coupling suitable for 2 HP multi stage pump set, complete all as specified and as directed. MAKE:- NE or equivalent as approved by GE

2

-

-

... More
S&F in repair of GM impeller for booster pump motor ,3 phase 415 v, 2HP/3HP capacity complete all as specified and as directed.

2

-

-

... More
Supply and fix in repair energy saving and environemntal friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire 72 W LED fitting with high power LEDs light source and electronic driver etc complete as specified and directed

5

-

-

... More
Supply and fix 15 W new generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aestheticallydesigned with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. clear cover offers bright illumination for different applications.

10

-

-

... More
S & F in replacement of street light brackets 40 mm bore GI pipe medicum grade upto 1.5 mtr long bend to shape including flat iron clamps and sutable nuts and bolts .etc complete all as specified and directed

10

-

-

... More
Material and labour for replacement of PVC insulated single core multistranded copper cable of size 1.5 sq mm unsheathed 1100 volts grade drawn through conduit / cassing capping on surface / pole / wall concealed and making good of disturbed surface including taking down unserviceable wire etc complete all as specified and directed

100

-

-

... More
S&F Bldg Security light energy efficient 1X20 Watt LED 6K Endura cityliner leaf (with Toughned glass) die cast aluminium and fixing arrangement of fitting including 1 mtr 35/50mm GI 90 degree bend pipe complete all as specified.

20

-

-

... More
Taking down the Unseviceable LT panel installed at PH and replacement with new one CPRI approved with following parts including panel board Wall mounted LT panel board indoor type of size 1500 x 1500 x400 mm with sheet CRCA sheet of 2 mm thickness comprising of the following :- ( a) 3 pole power contactor type ML 4 suitable for operation on,440 Volts, AC, 50 Hz -03 Nos (b) over load protection relay with relay range 45-75A suitable for operation on 3 phase, 415 V -01 Nos (c) voltmeter three phase anologue type class 1 voltage range 0-500 V flush mounting 96x96mm (d) ammeter three phase anologue type 5A class 1 of range 0-200 A flush mounting 96x96mm inculding CT 200/5 (e) MCCB 63A capacity 3 pole for 415V -01 Nos (f) Supply and fix in repair MCCB 200 A capacity 4 pole for 415V -01Nos (g) indicating lamp on all 3 phases R Y B -01 set (h) PVC insulated multistranded copper conductor single core cable 4 sq mm (Nominal cross sectional area) as per site requirement including suitable size of copper lugs etc all as specified and directed-01 Job (j) single phase preventer direct mounting type with relay range 28-40 A 230 Volts suitable for electric motor of water supply installation-01 No (k) Electronic timer type ST 100 suitable for operation on 240/360/415 volts 50 Hz for 3-10 Sec-01 Nos. (l) Painting complete panel board with one coat of silver inside and outside -01 Job

1

-

-

... More
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).

5

-

-

... More
Supply fixing testing and commissioning submersible cable flat 16 sqmm 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr lenght all as specified and directed.

250

-

-

... More
Supply fixing testing and commissioning submersible cable flat 1.5 sqmm 2 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer foe every column pipe of 3 mtr lenght all as specified and directed.

100

-

-

... More
Supply, installation, commissioning and testing in replacement of APFC panel of capacity 40 KVAR (20 KVAR X1,10 KVAR X 1,5 KVAR X 2) powder coated factory made outdoor type of suitable size made of CRCA sheet made from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:- (a) Incoming MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos (b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No. (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor. (e) Microprocessor based 3 phase current transformer sencing relay 4 stage = 01 No( for operating of capacitor bank) (f) Auto/Manually switch of capacitor bank (g) PCC 1:2:4 for installation of panel

5

-

-

... More
Supply install in repair and commissioning of Granular chlorination dosing pump of high pressure single head gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U S GPD and adjustable high pressure of up to 100 PSI (7 kg/cm2) or more , power input 230 V, 50 HZ self priming with nonmetalic with connecting nuts, ferrules and with all accessories including lead, tubing connection injection check valve complete all as specified and directed. Preparation tank (300 ltr) : (i) Water inlet line (ii) Outlet with strainer (iii) Drain (iv) Overflow (v) Conical bottom for sludge deposition (vi) Pot hole with over (vii) Level gauge (viii) Inspection port (ix) Agitator 120 watt 900 RPM single phase mounted with plastic shaft and impeller. Service Tank (100 ltr): (i) Water line inlet (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level gauge (vi) Inspection port make-Potter & watts/Briozing/Declibec.

3

-

-

... More
Supply and fixing all in one solar LED street light IP66 with high efficiency mono crystaline solar panel PV module not less than 12V, 20W lithium ferro phosphate battery with in-built BMS technology, capacity 12.8V, 10.5 Ah high efficiency LED 100LM/W, MPPT solar charge controller and aluminium extruded body & is specially programmed to automatically control the dimming and brightness of light, which increase the backup time and minimum 10 Hrs backup.

5

-

-

... More
Supply and fixing of display board of outer size 4.1X1.0 mtr made out of stainless steel of thickness 2 mm at square pipe 8X8 cm with back support of 40X5 mm stainless steel plate fitted at 3 fet interval of board backside including writing name of installation and unit as directed with reflecting tape of any colour as directed alongwith legs of size 8X8 cm square pipe upto the height of 14 feet from ground with foundation with stand 26 km/hr air velocity alongwith 02 nos of spot light at suitable place as directed with point wiring as directed.

5

-

-

... More
Supply and fixing aesthetically designed decorative banner arm single, enhancing the appearance of the pole including pole of size 50 mm dia of 03 mtr hight fitted in PCC (1:2:4) including foundation and coping of size 1' X 1' X 3' and banner of desired material including supportive rod on upper and bottom side of banner and fixed with clamp on arm and with writing description all as specified and directed by Engr-in-Charge.

5

-

-

... More
Dismantling and Taking Out old U/S LT Busbar chamber and Supply, installation, Commissioning and testing LT Busbar chamber,size of 600x600x400 mm for 3 phase, 6 wire, 415 Volts ,AC , 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick MS sheet with using 25mm x 25mm x 5mm angle iron frame and supports, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement and including PCC work for fixing panel legs and bus bar of Copper conductor suitable shape and size , 6 No of 200 amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size.

2

-

-

... More
Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter Feed pumps Complete in CI body& CI impeller with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, strainer at suction. The pump shall be suitable for 415±10% volts 3 phase AC supply . Pumps = 02 Nos.(1w + 1s) Flow rate (each) = 10 m³/hr Head = 25 - 30 m

2

-

-

... More
Supply and fixing in replacement of non clog type of submersible pump set with motor of capacity 12.5 HP, 415V, 50 Hz all as specified and directed by Engr-in-charge.Note:- Old unsv pumpset with motor will be deposited in MES store.

1

-

-

... More
Supply and fixing in replacement of PVC suction currugated hose pipe with flanged ends of green colour of bearing capacity 2500 Pa, temperature range 0deg-100deg and velocity 30-40 m/s of foloowing size all as specified and directed by Engr-in-Charge.

-

-

-

... More
(a) 25 mm bore

50

-

-

... More
(b) 50 mm bore

50

-

-

... More
(b) 80 mm bore

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.