Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jan 2025
Closing Date22 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Rewinding of ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire complete all as specified and directed.

400

-

-

... More
S&F in repair fan capacitor AC 440 volts 4 mfd 50HZ complete all as specified and directed.

200

-

-

... More
All as per item No 5 above but 2.5 mfd and complete all as specified and directed.

400

-

-

... More
All as per item No 5 above but 3.15 mfd and complete all as specified and directed.

150

-

-

... More
S&F in repair of gun metal bush suitable for any size / model / type of fans complete all as specified and directed.

70

-

-

... More
S&F in repair alignment grinding to shaft, remetalling & finishing all as required complete all as specified and directed.

300

-

-

... More
S&F in repair ceiling fan shaft of standard size including taking out old shaft, complete all as specified and directed.

70

-

-

... More
Supply and fixing in replacement fan regulator electronic, 80 Watt 5 step hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.

50

-

-

... More
M&L for painting of ceiling/exhaust fans in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and writing MES No. with black enamel paint etc. complete all as specified and directed. Note : White paint/Brown to be used for ceiling fans and gray/sky blue paint to be used for exhaust fans.

150

-

-

... More
Disconneting & taking down exhaust fan any type/make and size for servicing, strip opening of exhaust fan including servicing, cleaning with kerosen oil/thinner, oiling & greasing and complete at site. Re-assembling and refixing to the same/other location and testing complete after servicing and fixing for smooth and noise free operation of exhaust fan complete all as specified and directed.

200

-

-

... More
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair re-assembling, re-fixing after replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete all as specified and directed.

60

-

-

... More
Disconnecting electrically, taking down existing exhaust fan any type and capacity with due care, dismantling blades and removing for repair with all accessories complete all as specified and directed.

150

-

-

... More
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete all as specified and directed.

150

-

-

... More
S&F in repair of ball bearing suitable for ceiling fan upto 1400mm sweep complete all as specified and directed.

300

-

-

... More
S&F in repair of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete all as specified and directed.

100

-

-

... More
S&F in repair of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep complete all as specified and directed.

50

-

-

... More
S&F in replacement of fan blade set steel 1200/1400mm sweep complete all as specified and directed.

400

-

-

... More
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin of size 45 Cm long complete all as specified and directed.

50

-

-

... More
All as per item No 21 above but of size 1 Mtrs long and complete all as specified and directed.

5

-

-

... More
All as per item No 21 above but of size 1.5 Mtrs long and complete all as specified and directed.

4

-

-

... More
All as per item No 21 above but of size 2 Mtrs long and complete all as specified and directed.

2

-

-

... More
All as per item No 21 above but of size 3 Mtrs long and complete all as specified and directed.

2

-

-

... More
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed.

100

-

-

... More
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified & directed.

30

-

-

... More
M&L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed.

300

-

-

... More
M&L for in replacment matel clad socket single pole and neutral enclousere with a top pin, earth plug and socket with one MCB 20 Amps, 240 Volts complete all as specified & directed.

30

-

-

... More
S&F repair of ceiling fan clamps for fixing with fan rod including nut, bolt, lock pin, rubber seal complete all as specified & directed.

50

-

-

... More
Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site complete all as specified and directed.

120

-

-

... More
S&F in replacment of 2 feet flexible stainless steel connection pipe with two brass adopter as per existing suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.

80

-

-

... More
Supply only PVC connections 15 mm size with PTMT nuts of length 450 mm length (for hot and cold water inlet and outlet) complete all as specified and directed.

125

-

-

... More
M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply complete all as specified and directed.

100

-

-

... More
S&F in replacement of autocut suitable for 25/50 litres capacity Geyser complete all as specified and directed.

100

-

-

... More
S&F in replacement of geyser heating element triangular type 1500 Watt suitable for 25/50 litres capacity Geyser complete all as specified and directed.

40

-

-

... More
S&F in replacement of geyser heating element triangle 2000 Watt suitable for 25/50 litres capacity Geyser complete all as specified and directed.

40

-

-

... More
S&F in replacement of geyser heating element circular type 1500 Watt suitable for 25/50 litres capacity Geyser complete all as specified and directed.

40

-

-

... More
S&F in replacement of geyser heating element circular type 2000 Watt suitable for 25/50 litres capacity Geyser complete all as specified and directed.

40

-

-

... More
M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon assy with thermostate, heating element 2 KW and rubber gasket complete all as specified and directed.

30

-

-

... More
S&F inreplacement of unsv stainless steel inner tank suitable for 25/35 Ltr storage water heater/geyser complete as per existing all as specified and directed.

30

-

-

... More
S&F inreplacement of glass wool as existing suitable for 25/35 Ltr storage water heater/geyser as per existing complete all as specified and directed.

4

-

-

... More
S&F in repair/ replacment of pressure release valve with inlet coupling of superior quality complete all as specified and directed.

25

-

-

... More
S&F in repair/ replacment of plug top 15 Amps complete all as specified and directed.

80

-

-

... More
S&F in replacement stop valves, cromium plate cast copper alloy,screwed down,high pressure,with crutch or angular type, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.

20

-

-

... More
Checking thermostat calibration only of the geyser 25/50 ltrs capacity and setting temperature between 60 degree to 70 degree complete all as specified and directed.

60

-

-

... More
Material and Labour for Brazing of Storage Type water heater (Geyser) to stop leakage and testing of any capacity and make after completion upto the satisfaction of concerned JE/ Engr-in-Charge complete all as specified and directed. Note :- Disconnecting and reconnecting of geyser (water and elctric ) is included in unit rate.

25

-

-

... More
S&F in replacement of PCB for BLDC fan any type or make complete all as specified and directed.

100

-

-

... More
S&F in replacement of remote with battery of suitable cap for BLDC fan any type or make complete all as specified and directed. Note - For item no 48 & 49, contractor has to bring the item of directed make, to match with existing ceiling fan.

45

-

-

... More
M&L in repair for taking down/out desert cooler from exsting place and removing the old paint from the body of desert cooler and applying paint external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.

25

-

-

... More
M&L in replacment of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over and including a coat of primer etc complete all as specified and directed.

15

-

-

... More
M&L replacment of desert cooler water tank made out of 19 SWG mild steel sheet of size not more than 0.80x0.80x0.20 mtr (approx) to match with existing cooler including front side panel opening complete with louvers, provision for selector switch, indicator lamp etc and top cover plate made of 22 SWG mild steel along with vertical angle support of suitable height and two coat of synthetic enamel paint over and including a coat of primer etc complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacment of water lifting pump submersible type, 220 -240 Volts 50 HZ and head not less than 1.5 mtr complete all as specified and directed.

20

-

-

... More
Supply & fixing in repair of kit fan motor of desert cooler 230 volts with blades, fixing legs, nuts, bolts, washers etc of complete all as specified and directed.

10

-

-

... More
S&F in replacement of ready made wood wool pad of any size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.

50

-

-

... More
M&L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed

15

-

-

... More
S&F in repair of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.

5

-

-

... More
M&L in repair for dismantling taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as specified and directed.

15

-

-

... More
Disconnecting, dismantling old u/s selector switch and fixing with new selector switch complete all as specified and directed.

25

-

-

... More
Disconnecting, dismantling old u/s indicator lamps and replaced with new complete all as specified and directed.

30

-

-

... More
Dismantling old PVC Water distributor four way and refixing with new complete all as specified and directed.

10

-

-

... More
S&F in repair of existing UNSV desert cooler blade as per site requirement complete all as specified and directed.

12

-

-

... More
M&L for disconnecting, dismantling old u/s wiring of desert cooler and replacement with new wiring of selector switches and indication lamps and other as required at site with 1.5 Sqmm single core wires complete all as specified and directed. Note - Selector switch & indicator lamp wil be paid separately

11

-

-

... More
Supply and fix in repair electronic meters temper proof, LCD display with polycarbonate cover single phase, 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. NOTE:- old/unservicable energy meters will be deposited to E/M store.

30

-

-

... More
All same as per item No 64 above but 3 Phase, 415 volt complete all as specified and directed.

5

-

-

... More
Supply and fix metal louvers of suitable size for exhaust fan of the following sweep complete all as specified and directed.

-

-

-

... More
(a) 450 mm sweep complete all as specified and directed.

10

-

-

... More
(b) 300 mm sweep complete all as specified and directed.

80

-

-

... More
(c ) 230 mm sweep complete all as specified and directed.

25

-

-

... More
Supply and fix in replacment of 12 mm stainess steel fastner suitable for fixing geyser 25/50 ltrs complete all as specified and directed.

100

-

-

... More
Supply and fix in replacment of 10 mm stainess steel fastner suitable for fixing exhuast fan 300/450 mm complete all as specified and directed.

50

-

-

... More
Supply and fixing BLDC ceiling fan of cap 1200 mm sweep, with remote control copper winded, 230 v, 50 Hz 5 star rating complete all as specified and directed.

72

-

-

... More
Supply and fixing Normal ceiling fan of cap 1200 mm sweep, copper winded 230 v, 50 Hz 3 star rating complete all as specified and directed.

48

-

-

... More
S&F in replacement PVC ventilators, copper winded Single Phase 250mm sweep, with louvres complete all as specified and directed.

8

-

-

... More
S&F in replacement PVC ventilators, copper winded Single Phase 300mm sweep, with louvres complete all as specified and directed.

8

-

-

... More
S&F for Metal exhaust AC, copper winded ,Single Phase 300mm sweep 1400 RPM, with louvres complete all as specified and directed.

12

-

-

... More
S&F for Metal exhaust AC, copper winded, Single Phase 450mm sweep 1400 RPM, with louvres complete all as specified and directed.

6

-

-

... More
Supply, fixing, Testing water heater storage type with multifunctional safety valve, electric operated 230 V, Single Phase including one Nos of heating element, automatic thermal cut out, fusible plug, anti vaccum sys, built in presser release valve,thermostat, rust proof powder coated body, indicator lamps, 15 amps 3 pin plug top, all safety advices as per E-in-C's Branch technical instructions and of capacity 25 liters including provn of grouting bolts in walls including piller cock, pvc connection ect and making good disturbed surfaces complete all as specified and directed.

10

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.

540

-

-

... More
Taking down Old unserviceable switch, socket, ceiling rose, modular regulator, modular cover, call bell and switch sockets combination etc. without point wiring complete all as specified and directed.

300

-

-

... More
Taking down the unserviceable MCB DBs & metal clad sockets of any capacity/any type complete all as specified and directed.

51

-

-

... More
Taking down the unserviceable MCB of any rating and any size/type complete all as specified and directed.

78

-

-

... More
Taking down old unsreviceable sub main wiring of any size complete all as specified and directed.

620

-

-

... More
M&L for point wiring with 1.5 sqmm (nominal cross sectional area) single core PVC insulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including non metallic rigid PVC white conduit not less than 20mm dia and conduit accessories concealed/fixed to wall/floors/ceiling etc and provision of PVC Insulated heavy duty ISI marked unsheathed copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlests, fan regulators including fixing PVC round block 8 cm dia and 4 cm in depth etc, for the following.

-

-

-

... More
(a)One light point controlled by one 5 Amps switch complete all as specified and directed.

100

-

-

... More
(b)One ceiling fan/exhaust fan controlled by one 5 Amps switch complete all as specified and directed.

50

-

-

... More
(c) One socket 5 Amp on independent board complete all as specified and directed.

50

-

-

... More
(d) One socket 5 Amp on same board with other switches complete all as specified and directed.

25

-

-

... More
All as per item No 84 above but wiring with 2.5 sq mm FRLS copper cable including earth continuty conductor with 2.5 sq mm FRLS copper cable for one 6 pin 15 Amps socket outlet on independent board controlled by 15 Amps switch complete all as specified and directed.

50

-

-

... More
Point wiring with 1.5 Sqmm (nominal cross sectional area ) , single core, PVC insulated with multistranded PVC unsheathed copper conductor FRLS cable in and including PVC casing - caping of suitable size medium grade ISI marked complete and sunk CI/pressed steel terminal switch boxes flush mounting type with new hylam sheet (white) top cover, including earth wire continuity of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) copper conductor connected to all fittings, sunken boxes and common earth and connected to earth dolly for the following:-

-

-

-

... More
(a) One light point controlled by one 5 Amps switch complete all as specified and directed.

100

-

-

... More
(b) One ceiling fan/exhaust fan controlled by one 5 Amps switch complete all as specified and directed.

50

-

-

... More
(c) One 3 pin socket outlet, 5 Amps on the same board with other switches complete all as specified and directed.

25

-

-

... More
(d) One 3 pin socket outlet, 5 Amps, independent complete all as specified and directed.

55

-

-

... More
All as per item No. 90 above but wiring with 2.5 sq mm copper cable with 2.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out on independent board controlled by 15 Amps switch complete all as specified and directed.

35

-

-

... More
Supply and fix in repair switch piano 5 Amps flush type one way complete all as specified and directed.

455

-

-

... More
Supply and fix in repair socket outlet 5 pin 5 Amps multi pin flush type complete all as specified and directed.

155

-

-

... More
Supply and fix in repair switch socket combination 5 pin 5 Amps with box, multi pin flush type complete all as specified and directed.

100

-

-

... More
Supply and fix in repair switch socket combination 5/15 Amps with box, multi pin flush type complete all as specified and directed.

85

-

-

... More
S&F in repair ceiling rose, three terminal, PVC/polycarbonate, isolated body, complete all as specified and directed.

50

-

-

... More
Supply and fix in repair Modular switch 1 way 6A, 1 module type, 230 volts, complete all as specified and directed.

100

-

-

... More
Supply and fix in repair modular type Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, complete all as specified and directed.

50

-

-

... More
Supply and fix in repair modular type Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, complete all as specified and directed.

50

-

-

... More
Supply and fix in repair Modular switch 1 way 16A, 1 module, multipurpose flush type, complete all as specified and directed.

45

-

-

... More
S&F in repair Modular type stepped type electronic fan regulator 2 Module 230 Volts complete all as specified and directed.

25

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 1 module complete all as specified and directed.

20

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 2 module complete all as specified and directed.

20

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 3 module complete all as specified and directed.

50

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 4 module complete all as specified and directed.

10

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 6 module complete all as specified and directed.

10

-

-

... More
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME, 8 module complete all as specified and directed.

10

-

-

... More
Supply and fix MODULAR METAL FLUSH BOX 1/2 module complete all as specified and directed.

40

-

-

... More
Supply and fix MODULAR METAL FLUSH BOX 3 module complete all as specified and directed.

50

-

-

... More
Supply and fix MODULAR METAL FLUSH BOX 4 module complete all as specified and directed.

10

-

-

... More
Supply and fix MODULAR METAL FLUSH BOX 6 module complete all as specified and directed.

10

-

-

... More
Supply and fix MODULAR METAL FLUSH BOX 8 module complete all as specified and directed.

10

-

-

... More
M&L for sub-main wiring with two runs of 4sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 4 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 4 Sqmm and PVC conduct is measured as one Run or one Meter.

200

-

-

... More
All as per item No 117 above but in PVC Casing Capping complete all as specified and directed.

200

-

-

... More
M&L for sub-main wiring with two runs of 6 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 6 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces complete all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 6 Sq mm and PVC conduct is measured as one Run or one Meter.

60

-

-

... More
All as per item No 119 above but in PVC Casing Capping complete all as specified and directed.

60

-

-

... More
M&L for sub-main wiring with four runs of 10 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with copper stranded conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 10 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces complete all as specified and directed. Note: Four runs of 10 Sqmm copper cable, one run of 10 Sqmm copper cable for earth continuity and PVC conduit will be measured as one run or one meter.

50

-

-

... More
All as per item No 121 above but in PVC Casing Capping complete all as specified and directed.

50

-

-

... More
Supply and fix in repair sheet metal enclosures for MCB distribution board 415 Volts Triple pole and neutral 4 way, Double door with 200A rated bus bar including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed. Note : MCBs to be paid separately.

3

-

-

... More
Supply and fix in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 16 way Double door with 200A rated bus bar including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed. Note : MCBs to be paid separately.

2

-

-

... More
Supply and fix in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door with 200A rated bus bar including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed. Note : MCBs to be paid separately.

5

-

-

... More
Supply and fix in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200A rated bus bar including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed. Note : MCBs to be paid separately.

5

-

-

... More
Supply and fix in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way, Double door with 200A rated bus bar including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed.. Note : MCBs to be paid separately.

6

-

-

... More
Supply and fix in repair 63 Amp rating, 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single Pole and Neutral in the MCB DB with connection testing and commissioning complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 32 Amps rating, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of Single Pole and Neutral, in the MCB DB with connection testing and commissioning complete all as specified and directed.

20

-

-

... More
Supply and fix in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB with connection testing and commissioning complete all as specified and directed.

50

-

-

... More
M&L in replacment of Supply and fix Aluminium strip 25x3.15 with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.

300

-

-

... More
M&L in replacment of Earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanised iron earth strip 25x4mm thick by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip for lightening arrester shall be provided with HDPE pipe, protection pipe of 32 mm dia and water pipe of size 20 mm dia shall be provided. excavation earth work, PCC chamber RCC cover slab charcoal, salt, wiremesh water funnel etc all applicable and as per plate No 5 and all as specified. (Note (i) : The rate is inclusive of earth work and excavation PCC chamber in PCC (1:3:6) type C1 RCC Cover slab 50mm thick with RCC (1:2:4) type B1, with 8mm CTD bars re-inforcement both ways at 140mm centre to centre.Note (ii): Earthing lead from earth plate to test point upto 7.5 Mtr is deemed to be included in item.

10

-

-

... More
M&L in replacment of Supply and fix Test Point Terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw including removing the existing u/s test point terminal bloch complete all as specified and directed.

4

-

-

... More
M&L in replacment of Supply and fix Air termination, single pointed alluminium rod 12mm dia and 300 mm long including floor coupling for joint the lightening conductor complete all as specified and directed. Note : The conductors and termination point should not touch the buildings surface and quoted rate is deemed to the inclusivee of fixing arrangements.

100

-

-

... More
M&L in replacment of Earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, protection pipe of 15 mm dia and water pipe of size 20 mm dia shall be provided. excavation earth work, PCC chamber RCC cover slab charcoal, salt, wiremesh water funnel etc all applicable and as per plate No 3 and all as specified. (Note (i) : The rate is inclusive of earth work and excavation PCC chamber in PCC (1:3:6) type C1 RCC Cover slab 50mm thick with RCC (1:2:4) type B1, with 8mm CTD bars re-inforcement both ways at 140mm centre to centre.Note (ii): Earthing lead from earth plate to test point upto 7.5 Mtr is deemed to be included in item No.1.

10

-

-

... More
M&L for earth resistance test of all type of earthing of electrical & water supply installation or any special equipment or bldg earthing using digital earth resistance tester, the result of each earthing to be noted in a register duly signed by JE & AGE EM complete all as specified and directed. Note – Digital Earth resistance tester has to be provided by contractor

100

-

-

... More
Repair, maint and making the continuity of electric supply after rectifying the defects of the water cooler, refrigrator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceeding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifing the defact on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor

60

-

-

... More
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner of 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening by using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor.

8

-

-

... More
S&F in replacement of cooling coil of window type AC of capacity up to 2 ton complete all as specified and directed.

4

-

-

... More
S&F in replacement of front grill of window AC suitable for 1.5/2 ton capacity complete all as specified and directed.

4

-

-

... More
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton capaciy complete all as specified and directed.

4

-

-

... More
S&F in replacement of Air blower motor suitable for window type AC of 1.5/2 Ton capacity single phase complete all as specified and directed.

4

-

-

... More
S&F in replacement of starting capacitor suitable for window AC of rating 45 - 100 Mfd complete all as specified and directed.

4

-

-

... More
S&F in replacement of starting relay suitable for Window AC of capacity 1.5 / 2.0 Ton complete all as specified and directed.

2

-

-

... More
S&F in replacement of rotary /push type selector switch suitable for window type AC of capacity 1.5 / 2.0 Ton complete all as specified and directed.

4

-

-

... More
S&F in replacement of thermostat switch for window/split type AC of 1.5 /2.0 Ton capacity complete all as specified and directed.

4

-

-

... More
S&F in replacement of condenser fan blade suitable for window type AC of any make & capacity complete all as specified and directed.

4

-

-

... More
M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spary painting with a coat of synthetic enamel paint of requried shade complete all as specified and directed.

4

-

-

... More
Supply and fixing of micron filter suitable for window type AC of 1.5 Ton capacity complete all as specified and directed.

4

-

-

... More
S&F in replacement of Sensor for window type AC's, of any model / make complete all as specified and directed.

4

-

-

... More
Disconnecting electrically and opening the cover of split AC 1.5/2 ton capacity inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as specified and directed.

10

-

-

... More
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and for replacing with new spares as per model / capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.

20

-

-

... More
S&F in replacement of sealed compressor, rotary type, of any make suitable for split type AC of 1.5/2 Ton capacity complete all as specified and directed.

2

-

-

... More
S&F in replacement of Inlet/ outlet control valve for outdoor / indoor unit of split AC, of any size/make & any type complete all as specified and directed.

4

-

-

... More
S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s complete all as specified and directed.

6

-

-

... More
S&F in replacement of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed.

5

-

-

... More
S&F in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed.

4

-

-

... More
Supply and fixing of micron filter suitable for split type AC of 1.5 Ton capacity complete all as specified and directed.

5

-

-

... More
Supply and fixing of annealed copper tube of 375 mm outer complete all as specified and directed.

50

-

-

... More
Supply and fixing of annealed copper tube of 625 mm outer complete all as specified and directed.

50

-

-

... More
Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete all as specified and directed.

1

-

-

... More
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard with outer/inner unit, copper tubing, drain pipe and remote complete all as specified and directed.

4

-

-

... More
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 162 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion complete all as specified and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required.

4

-

-

... More
S&F in replacement of foamed polythene insulating pipe of 16 mm internal dia and 13 mm wall thickness complete all as specified and directed.

40

-

-

... More
S&F in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.

40

-

-

... More
S&F in replacement of Main control circuit (PCB) for normal split AC's, of any model / make complete all as specified and directed.

3

-

-

... More
S&F in replacement of (PCB) main control circuit of indoor unit for invertor type 1/ 1.5/ 2 ton split AC for split type AC's, of any model / make complete all as specified and directed.

4

-

-

... More
S&F in replacement of (PCB) main control circuit of outdoor unit for invertor type 1/ 1.5/ 2 ton split AC for split type AC's, of any model / make complete all as specified and directed.

3

-

-

... More
S&F in replacement of Sensor for split type AC of capacity 1/1.5/2 ton of any model / make complete all as specified and directed.

4

-

-

... More
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia, 1.5 mtr length with PVC adoptors on both end complete all as specified and directed.

40

-

-

... More
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia, 2 mtr length with PVC adoptors on both end complete all as specified and directed.

12

-

-

... More
S&F in replacement of drain tray suitable for 1 ton split AC complete all as specified and directed.

10

-

-

... More
S&F in replacement of drain tray suitable for 1.5 ton split AC complete all as specified and directed.

10

-

-

... More
S&F in replacement of drain tray suitable for 2 ton split AC complete all as specified and directed.

10

-

-

... More
M&L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR capacity at site / contractor's workshop including any welding / repair work required at site complete all as specified and directed.

12

-

-

... More
Supply & fix in concealed or fixed on wall upto 15 m Height of rigid non-metallic PVC conduit medium grade of size 25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC complete all as specified and directed.

20

-

-

... More
Supply & fix in concealed or fixed on wall upto 15 m Height of rigid non-metallic PVC conduit medium grade of size 32 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC complete all as specified and directed.

20

-

-

... More
Supply and filling refrigerant R-22/R134a/R410 environment friendly refrigerants as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc one time for topping up or making full qty including plugging the leakage/ welding / repair work required at site complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacment of blower blade of split AC indoor unit of capacity 1 ton complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacment of blower blade of split AC indoor unit of capacity 1.5 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of blower blade of split AC indoor unit of capacity 2 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of blower BLDC motor of split AC indoor unit of capacity 1.5 ton complete all as specified and directed.

3

-

-

... More
Supply and fixing in replacment of blower BLDC motor of split AC indoor unit of capacity 2 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of copper evaporator of split AC indoor unit of capacity 1 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of copper evaporator of split AC indoor unit of capacity 1.5 ton complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacment of copper evaporator of split AC indoor unit of capacity 2 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of swing motor for split AC indoor unit cap 1/ 1.5/ 2 ton complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacment of blower BLDC motor suitable for split AC outdoor unit of capacity 1 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of blower BLDC motor suitable for split AC outdoor unit of capacity 1.5 ton complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacment of blower BLDC motor suitable for split AC outdoor unit of capacity 2 ton complete all as specified and directed.

2

-

-

... More
Disconnecting, dismantling and taking out old u/s voltage stabilizer of capacity 2 to 5 kVA and refixing the same in same/other location after repair including all minor parts i.e wire, nut, bolt and washers etc complete all as specified and directed. Note : Spare parts will be measured and paid seperately under respective items.

15

-

-

... More
S&F in replacement of Main relay of voltage stabilizer 3 to 5 KVA complete all as specified and directed.

4

-

-

... More
S&F in replacement of Main control circuit (PCB) of voltage stabilizer 3 to 5 KVA complete all as specified and directed.

4

-

-

... More
S&F in replacement of replacement of sensor transformer of voltage stabilizer 3 to 5 KVA complete all as specified and directed.

4

-

-

... More
S&F in replacement of voltmeter of voltage stabilizer 3 to 5 kVA complete all as specified and directed.

3

-

-

... More
S&F in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 kVA complete all as specified and directed.

3

-

-

... More
S&F in replacement of transformer 3 to 5 kVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.

3

-

-

... More
Disconnecting electrically and water pipe line of water cooler any type/ capacity/ model for cleaning, using suitable cleaning agent or soap solution, including inside water storage tank & outside surface of the water cooler and re-connecting the same electrically and water pipe line & making it servicable for drinking water after cleaning complete all as specified and directed.

15

-

-

... More
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.

2

-

-

... More
Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair complete all as specified and directed.

5

-

-

... More
M&L for fixing/installation of water cooler any type of capacity 40/ 80/ 150 ltrs and making all electrical/water connection and testing after repair complete all as specified and directed.

4

-

-

... More
S&F in replacement of sealed compressor suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs complete all as specified and directed.

1

-

-

... More
S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd for water cooler complete all as specified and directed.

2

-

-

... More
S&F in replacement of Running capacitor 10-30 Mfd for water coller/ window ac/ split ac/refrigerator complete all as specified and directed.

2

-

-

... More
S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs complete all as specified and directed.

2

-

-

... More
S&F in replacement of Starting relay of water cooler as per compressor requirement complete all as specified and directed.

2

-

-

... More
S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement complete all as specified and directed.

1

-

-

... More
S&F in replacement of Over load protector suitable for water cooler complete all as specified and directed.

5

-

-

... More
S&F in replacement of PVC transparent flexible pipe of size 15 / 20 mm dia for water cooler complete all as specified and directed.

8

-

-

... More
S&F in replacement of Brass chromium plated Push cock heavy duty universal type, suitable for water cooler of capacity up to 150 ltrs complete all as specified and directed.

3

-

-

... More
S&F in replacement of PVC float valve 15 / 20 mm dia with rod & ball for water cooler complete all as specified and directed.

3

-

-

... More
S&F in replacement of Liquid line filter one way / two way for water cooler complete all as specified and directed.

3

-

-

... More
S&F in replacement of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed.

3

-

-

... More
S&F in replacement of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed.

2

-

-

... More
S&F in replacement for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed.

2

-

-

... More
S&F in replacement for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed.

2

-

-

... More
M&L in repair for filling up cavity nearby indoor unit through the wall vermin/rat proof from outside using PU foam spray all purpose cosmos MRO preferabbly off white in color & 750 mm bottle complete all as specified and directed.

6

-

-

... More
S&F in replacement for water leakage tray from indoor unit any type & any make, height upto 15 ft complete all as specified and all as directed.

8

-

-

... More
S&F in replacment of split AC indoor unit complete of capacity 1.5 ton 3 star rating built with copper evaporator including connecting with existing outdoor unit with electrically, gas pipes, electronic circuits and other accessories complete all as specified and directed.

2

-

-

... More
S&F in replacment of split AC outdoor unit complete of capacity 1.5 ton 3 star rating built with copper evaporator including connecting with existing indoor unit with electrically, gas pipes, electronic circuits and other accessories complete all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.