Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Date10 Jan 2025
Tender Amount₹ 1,30,00,000
Costs
EMD
₹ 2,05,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682948_1Tender No
CE RnD/DLI-24/AGRA/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 20 KVA, 415V AC supply 3 phase, 50 HZ, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank vibration damper and other accessories with acoustic enclouser as per latest CPCB-IV norms and AMF panel including PCC foundation work as per OEM reccommandation and taking out the old DG set from the location and deposited to MES store Yard complete all as specified and directed, internally comprising of following .
(A) DIESEL DRIVEN ENGINE :- Developing a net output suitable matched to give a net rated output of suitable to drive 20 KVA alternator, at 0.8 power factor 415 volts. The engine should be capable of delivering the required output at 1500 RPM, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.
(i) Fly wheel to suit flexible coupling and fly wheel housing.
(ii) Air cleaner complete as per manufacturer specification.
(iii) Fuel injection pump.
(iv) Flexible coupling with guard, nuts and bolts.
(v) Fuel filter with mounting.
(vi) Oil filter with mounting.
(vii) Starter motor as per manufacture's design.
(viii) Exhaust, silencer industrial type with exhaust pipe suitable length.
(ix) Batteries 12 volts 1x180 AH maintenance free batteries with copper lead, terminals etc.
(x) Instrument panel complete with microprocessor based controller comprising shut down valve indication, LCD hour counter indication, RPM indication , LED lamps for fail to start, over speed /under speed . Low lub oil pressure, high engine coolant temperature gaugae.
(xi) Dynamo/alternator suitable rating.
3
-
-
... More
(B) ALTERNATOR:- The above engine will be coupled through flexible coupling on an indigenous alternator mounted in a strong steel fabricated common base frame suitable for mountingin an acoustic enclousre. The alternator will be 3 phase 50 HZ 1500 RPM self reglating self existing type and have class H insulation of stator and rotor windings and generate 20 KVA output at 0 .8 Power factor 4 wire 415 volts AC supply under NTP condition with a provision of 10% overload for 1 hour in every 12 hrs running. The alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.
(C) CONTROL PANEL :- S&F AMF (Automatic on mains failure) control panel CPRI approved outdoor ype KIOSK ' water, dust and vermin proof and fabricated out of 3.15 mm thick CRCA sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 Hz AC supply with and incl the following :-
(i) MCCB of suitable capacity
(ii) Necessary relays, times and power contractors of suitable rating/capacity for auto ON-OFF the DG set and changeover of the load in case of power failure.
(iii) Digital mulfifunctional meter for phase wise reading of amps, voltage KWH and frequency -01
(iv) Internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.
(v) Earthing terminals 02 Nos
(vi) Auto/Manual start switch to by pass auto start.
(vii) Battery charging system suitable for charging for charging the battery provided with the DG Set incl boost/stickle switch and system, DC voltmeter digital type
-
-
-
... More
(D) FUEL TANK :- One No built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacity to run the DG for 12 Hrs countinuous running with inlet and outlet connection including the following :-
(i) Level indicator with float and gauge.
(ii) Fuel piping for fuel supply to engine and over flow to tank
(iii) Fuel strainer
(E) ACOUSTIC ENCLOSURE :- Enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per IS 8528 part 10 and as per approved CPCB morms. the acoustic encloure must consist of the following :-
(i) CRCA sheet with body 16 SWG thick.
(ii) Base frame fabricated from ISMS Channel
(iii) Insulated rock wool fire retardant/non-igniting noice reduction type and properly clamped provided on all doors, roof and sides.
(iv) Special designed SS doors locks and door hinges..
(v) Thermostate switch to shut off the engine in case the temperature inside the accoustic enclousre increases beyond 70 degree Celsus.
(vi) Glass windows in acoustic enclousre suitably located to read/check the various meters and controls
-
-
-
... More
Supply, install, testing & commissioning machine room less, Lift 8 Passanger, 544 Kgs suitable to serve G+2 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set including taking out the old Lift set from the location and deposited to MES store Yard all as specified below :-
Note:-
(i) Contracor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 before dispatch of material from OEM (ii) The existing lift well dimension are 1870 mm x 1870 m, centre opening door size 800 mm . However contractor is advised to visit the site before quoting the rate. (iii) Any civil / mechenical work required for proposed installation of new lift with respect to safety required by OEM will be carried out by the contractor, cost of same shall be deemed included in the quoted rate. (iv) The Contractor shall be responsible for 2 year defect liability period from certified date of completion of GE. During the said defect liability period the lift shall be kept functional/serviceable all the time & all consumable items shall be provided by the Contractor for operation and maintenance of lift. All periodical maintenance, regualar check up/inspection shall be carried out by OEM during two year defect laibility period. In addition to regular check up and periodical services special visit/inspection will also be carried to rectify defects by representative of OEM, if any emergency/trouble developed. An agreement will be made between Contractor and OEM and this shall be submitted to GE on the date of handing over of the lift (date of completion) for comprehensive maintenance of defect liability period. The cost of above shall be deemed to be included in the quoted rates.
(v) The provision of suitable steel structure/platform for installation of lifts equipment is part of lift items and nothing extra should be paid.
(vi) If any clearance required to be sought from state govt. i.e. from lift inspector or electrical safety department or fire safety department is the contractor's responsibility & any expenditure on this account shall be deemed to be included in the quoted unit rates.
1
-
-
... More
BASIC DATA:-
(a) Type of Lifts : Passenger.
(b) Load & capacity : 544 Kgs/ 08 Persons
(c) Speed : 1.00/ mtr/sec with single speed motor
(d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Stops and openings : 3 Stops and 3 openings, Single entrance Car.
(f) Travel height : 3 Floor.
(g) Car size : 1100 mm wide x 1300 mm deep x 2200 mm height.
(h) Door size : 800 mm wide .
(j) Door type : Two- panel Centre opening T, frameless glass door.
-
-
-
... More
CAR FINISHES:-
Rear Mid Panel : Stainless Steel
Rear Corner Panels : Stainless
SteelSide Mid Panels : Stainless Steel
Side Corner Panels : Stainless Steel
Front Panels : Stainless Steel
-
-
-
... More
STANDERED FEATURES
(a) Anti-nuisance Car Call Protection
(b) Independent Service (for Duplex only)
(c) Overload Device
(d) Nudging
(e) Emergency Car Light Unit
(f) Infrared Curtain Door Protection
(g) Door Time Protection
(h) Emergency Alarm Button
(j) Extra Door Time of Lobby & Parking
(k) Door Open/Close Button
(l) Manual Rescue Operation
(m) Belt Inspection Drive
(n) Regenerative Drive
(o) Auto Fan Cut Off
(p) Emergency Firemen’s Service,
(q) Automatic Rescue operation,
(r) Intercom.
(s) CCTV Provision (CAT-6 Cable)
-
-
-
... More
Supply , laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm Sqmm 3.5 Core
150
-
-
... More
M&L for earthing complete with copper earth plate electrode of size 60cm x 60 cmX 3.15 mm thick buried in the ground to a depth not less than 2.25 mtr below ground level connected to copper strip 20 ×3 mm as earthing lead by means of GI nut, bolts, washers and check nut and complete as shown in electric plate No 03 of SSR Part-I including 20 mm dia GI pipe medium grade for watering, funnel and PCC pit cover with RCC cover of size 30cm x 30cm including earth work for excavation and removal of surplus soil complete all as specified and directed.
8
-
-
... More
M&L for Sheet metal enclosures for MCB DB Triple pole and neutral, double door, 4 way, 415 volts, powder coated with IP 43 protection, including provision and housing MCB,s and fixed flush on wall and grouting complete all as specified and as directed. Notes:- (a)The cost of fixing the DB flush to brick / stone wall surface, including cutting holes / chases, packing around the DB, making good and finishing to match surrounding surfaces shall be deemed to be included in the quoted rates. (b) MCBs shall be measured and paid separately.
1
-
-
... More
Supply and fixing 415V 10KA 'B' 63 Amp curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
2
-
-
... More
Supply and fix, MCB, SP, 6-32 Amp all as specified and directed.
1
-
-
... More
M&L for earthing complete with GI earth plate electrode of size 60cm x 60 cmX 6 mm thick buried in the ground to a depth not less than 2.25 mtr below ground level connected to GI strip 25X4 mm as earthing lead by means of GI nut, bolts, washers and check nut and complete as shown in electric plate No 03 of SSR Part-I including 20 mm dia GI pipe medium grade for watering, funnel and PCC pit cover with RCC cover of size 30cm x 30cm including earth work for excavation and removal of surplus soil complete all as specified and directed.
18
-
-
... More
M&L earthing complete with galvanised steel earth plate electrode, 60x60cmx 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion
2
-
-
... More
Supply and fixing ceiling fans complete with blades, down rods ,remote for speed regulation and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and fixing electronic fan regulator compatible with BLDC fan including Smart remote to regulate speed and necessary materials, erected in provided hook/clamp including taking down the old fan and deposited to MES store Yard inculding marking of Sr No and date of errection with superior quality enamel paint of specified colour.
151
-
-
... More
Taking down old unserviciable Window/Split type air conditioner of capacity 1.5/ 2.0 TR from its original position at any height, disconnecting all electrical connection and depositing to MES Store of AGE E/M (R&D) Agra, complete all as specified and directed.
33
-
-
... More
Taking down old unserviciable desert coller of capacity 4000 CuM per hrs steel body from its original position at any height, disconnecting all electrical connection and depositing to MES Store of AGE E/M (R&D) Agra, complete all as specified and directed.
38
-
-
... More
Taking down old unserviciable Water cooler of any size type from its original position, disconnecting all electrical connection and depositing to MES Store of AGE E/M (R&D) Agra, complete all as specified and directed.
13
-
-
... More
Supply, fixing, testing and commissioning of window type air conditioner complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with ISEER 3.5 (5 Star), electric driven single phase of capacity 1.5 Ton, by cutting walls/window/ grill and making good with cement mortar/welding work,finishing to match the surrounding,maikng airtight around the window AC opening with suitable material incl Industrial socket& plug of suitable size, standard angle iron frame work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units
12
-
-
... More
Supply, fixing, testing and commissioning of hi wall split units indoor & outdoor of capacity 1.5 TR,Hot and cold AC, complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with latest ISEER 5.0 rating(5 star), electric driven single phase installing at wall/roof/floor upto three storey building, electrical connection with Industrial Socket & plug of suitable capacity ISI marked , including necessary PVC drain pipe upto a length of 15M, concealed brick/stone wall/floor by cutting chases and making good, finishing to match the surrounding, copper tubing upto 6 M length for suction & discharge line, standard angle iron frame work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Notes:- Quoted rate shall be including of followings.
(a) The Contractor shall make necessary opening on the brick/stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed by Engineer-in-Charge.
(b) The refrigerant pipe and cable shall be drawn through and including flexible PVC conduit 40mm dia duly fixed on wall with suitable clamps, screws complete all as directed by Engineer-in-Charge.fixing PVC drain pipe for water drainage and jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall/floor including grouting of angle iron 50X50X6 mm or MS fabricated AC stand of required size complete all as specified and as directed.
9
-
-
... More
Supply, fixing, testing and commissioning of hi wall split units indoor & outdoor of capacity 2.0 TR,Hot and clod AC, complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with latest ISEER 3.8 rating(3 star), electric driven single phase installing at wall/roof/floor upto three storey building, electrical connection with Industrial Socket & plug of suitable capacity ISI marked , including necessary PVC drain pipe upto a length of 15M, concealed brick/stone wall/floor by cutting chases and making good, finishing to match the surrounding, copper tubing upto 6 M length for suction & discharge line, standard angle iron frame work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. The contractor shall furnish the manufacturers warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Notes:- Quoted rate shall be including of followings.
(a) The Contractor shall make necessary opening on the brick/stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed by Engineer-in-Charge.
(b) The refrigerant pipe and cable shall be drawn through and including flexible PVC conduit 40mm dia duly fixed on wall with suitable clamps, screws complete all as directed by Engineer-in-Charge.fixing PVC drain pipe for water drainage and jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall/floor including grouting of angle iron 50X50X6 mm or MS fabricated AC stand of required size complete all as specified and as directed.
12
-
-
... More
Supply and fixing of desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size) Steel body ISI marked and shall confirm to IS 277, electric control panel consisting two nos 5 amp switch, one rotary speed regulator switch,Exhaust fan and submersible pump shall confirm to IS 2312 and IS 11951 respectively steel body dully painted with two coats of water resistance paint over one coat of primer internally and two coat syntetic enamel paint externally including all electrical connections, testing and commisioning complete all as specified and directed.
38
-
-
... More
Supply and fix water cooler electric driven (single phase), fully SS tank and body having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour,with in built RO+UV purification fully automatic system,with longer cooling retention,Eco-frindly Refrigerant, anti-corrosive pre-coated Body including necessary connection with existing pipe line all as specified and directed by Engineer inCharge.
4
-
-
... More
Supply and fix water cooler electric driven (single phase), fully SS tank and body having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour,with in built RO+UV purification purification fully automatic system,with longer cooling retention,Eco-frindly Refrigerant, anti-corrosive pre-coated Body including necessary connection with existing pipe line all as specified and directed by Engineer inCharge.
9
-
-
... More
Dismantling tile work upto 25 mm thickness in floors and walls laid in cement mortar including disposing debris out of premises.
20
-
-
... More
M&L for Ist quality ceramic glazed wall tiles of size 450mm X 300mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as spd and directed.
20
-
-
... More
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and out of premises.
30
-
-
... More
M&L for 25mm thick Kota stone slab flooring (over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
30
-
-
... More
M&L for Providing and fixing 18 mm thick Granite stone slab all colour and texture except black, cherry/ ruby red, area of slab upto 0.50 sqm, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 : 4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish complete at all levels.
20
-
-
... More
Material and labour for 15 mm cement plaster on brick wall of mix 1 : 6 (1 cement : 6 fine sand) complete all as specified and directed.
18
-
-
... More
Demolishing brick work In cement mortar, manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
1
-
-
... More
M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed.
1
-
-
... More
M&L prepration new plastered surfaces and applying three or more coats of white washing with lime to give an even shade complete all as specifed and directed.
72
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%