Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Feb 2025
Closing Soon13 Mar 2025
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698559_1Tender No
8346/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge.
1500
-
-
... More
Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 90 mm, inner dia 75 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge.
500
-
-
... More
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
4
-
-
... More
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 400Sqmm single core as per IS 7092 Pt -I complete all as specified and directed.
100
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 300Sqmm single core as per IS 7092 Pt -I complete all as specified and directed.
100
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 400Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
60
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 300Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
60
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 240Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
100
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 185Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 150Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 120Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
300
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 95Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
400
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 50Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
300
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 35Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
300
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 25Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed.
500
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16Sqmm 4 core as per IS 7092 Pt -I complete all as specified and directed.
300
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10Sqmm 4 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16Sqmm 2 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10Sqmm 2 core as per IS 7092 Pt -I complete all as specified and directed.
200
-
-
... More
M&L for taking out under ground LT cable different sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size and re-laying in the same trenches or re-routing after rectification of fault as required complete all as specified and directed
NOTE:- (i) Joints & Jointing materials, new cable, additional bricks/ HDPE pipe, shall be measured & paid for separetely.
(ii) Retrieved serviceable bricks or PCC cable cover and sand shall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate.
250
-
-
... More
M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 25 sqmm to 50 Sqmm 3.5 core XLPE armored aluminum conductor cable including jointing with copper lugs and ferrules complete all as specified and directed.
5
-
-
... More
M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 70 sqmm to 120 Sqmm 3.5 core XLPE armored aluminum conductor cable including jointing with copper lugs and ferrules complete all as specified and directed.
5
-
-
... More
M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 150 sqmm to 240 Sqmm 3.5 core XLPE armored aluminum conductor cable including jointing with copper lugs and ferrules complete all as specified and directed.
5
-
-
... More
Supply , installing, testing and commissioning factory made and tested, CPRI approved LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work, minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a) Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b) The holes/ aprons of cable entry/ exit will be closed with suitable size of glands.Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd Incoming
(b) MCCB, 04 Pole, 400 Amps with ultimate breaking capacity 36 KA at 415 volts, with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), Make - L&T/ABB/Havells/Schneider/Legrand
4
-
-
... More
Outgoing
(c) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%),Make - L&T/ABB/Havells/Schneider/Legrand
(d) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos (Ics=Icu=100%) ,Make - L&T/ABB/Havells/Schneider/Legrand
(e) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic typeconforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) ,Make - L&T/ABB/Havells/Schneider/Legrand
(f) Digital type voltmeter 0-500 Volt with selector switch with MCBs -1 Set
(g) Digital type Ammeter 0-600 Volt with selector switch with MCBs -1 Set
(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. a) Aluminum bus bar four strips 600 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
-
-
-
... More
Supply , installing, testing and commissioning factory made and tested, CPRI approved LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work, minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a) Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b) The holes/ aprons of cable entry/ exit will be closed with suitable size of glands.Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd(a) Aluminum bus bar four strips 500 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Incoming
(b) MCCB, 04 Pole, 315 Amps with ultimate breaking capacity 36 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
4
-
-
... More
Outgoing
(c) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release and Adjustable magnetic type conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%),L&T/ABB/Havells/Schneider/Legrand
(d) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic type conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
(e) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic type conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
(f) Digital type voltmeter 0-500 Volt with selector switch with MCBs -1 Set
(g) Digital type Ammeter 0-500 Volt with selector switch with MCBs -1 Set
(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
-
-
-
... More
Supply , installing, testing and commissioning factory made and tested, CPRI approved LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work, minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:- (a) Panel drawings and make of MCCB will be submitted by contractor for approved by GE before orders the panel. (b) The holes/ aprons of cable entry/ exit will be closed with suitable size of glands.Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd (a) Aluminum bus bar four strips 400 Amps ,415 volts, fixed on epoxy insulated on panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Incoming
(b) MCCB, 04 Pole, 250 Amps with ultimate breaking capacity 36 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
6
-
-
... More
Outgoing
(c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 25 KA at 415 volts with Adjustable thermal release and fixed magnetice settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
(d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic type conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
(e) MCCB, 04 Pole, 40 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release and Fixed magnetic type conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), L&T/ABB/Havells/Schneider/Legrand
(f) Digital type voltmeter 0-500 Volt with selector switch with MCBs -1 Set
(g) Digital type Ammeter 0-500 Volt with selector switch with MCBs -1 Set
(h) Indication lamps R,Y,B LED type with 3 Nos of 2A HRC fuses -1 set: i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
Note: Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
-
-
-
... More
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and salt and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item.
76
-
-
... More
S&F for replacement & testing commissioning of outdoor type bus bar panel weather proof , IP - 65 class protection, MS cubical panel board made of 3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 400 Amp capacity with MCCB 4 pole of Capacity 250 Amp 25 KA (Ics =Icu=100%,Make - L&T/ABB/Havells/Schneider/Legrand) including one coat of redoxide and two coat of enamel paint powder coated, mounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
6
-
-
... More
S&F for replacement & testing commissioning of outdoor type bus bar panel weather proof , IP - 65 class protection, MS cubical panel board made of 3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%,Make - L&T/ABB/Havells/Schneider/Legrand) including one coat of redoxide and two coat of enamel paint powder coated, mounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
6
-
-
... More
S&F for replacement & testing commissioning of outdoor type bus bar panel weather proof, IP-65 Class protection, MS cubical panel board made of 3.15 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 250 Amp capacity with MCCB 4 pole of Capacity 160 Amp 25 KA (Ics =Icu=100%, Make - L&T/ABB/Havells/Schneider/Legrand) including one coat of red oxide and two coat of enamel paint powder coated, mounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd Note:-(i) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(ii) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
8
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 63 Amps with ultimate breaking capacity 16 KA at 415 volts with Adjustable thermal release, fixed magnetic release settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make - L&T/ABB/Havells/Schneider/Legrand
4
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 100 Amps with ultimate breaking capacity 36 KA at 415 volts Adjustable thermal release, fixed magnetic release settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make - L&T/ABB/Havells/Schneider/Legrand
5
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 160 Amps with ultimate breaking capacity 25 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
4
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 200 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
3
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 250 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
2
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 320 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
2
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 400 Amps with ultimate breaking capacity 36 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
2
-
-
... More
S & F in replacement of MCCB, 04 Pole, capacity 630 Amps with ultimate breaking capacity 50 KA at 415 volts with Adjustable thermal release, Adjustable magnetic type settings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) including spreader terminals & connected accessories complete and connected in the existing panel with suitable lugs/ferrules in terminals at site complete all specified and directed. Make-L&T/ABB/Havells/Schneider/Legrand
3
-
-
... More
S&F in replacement of Air Circuit Breaker 4 Pole, 630 Amps, 415 V, 50 Hz,50 KA Manual Fixed type with microprocessor release for second as per IS/IEC:60947-2, ICS=ICU= 100% with over load current and time settings, short circuit current and time settings, INST current settings, Ground fault settings , manual operated inclunding dismantling and taking out old U/s ACB from panle & fabrication work to bus bars for proper fittings etc complete all specified and directed. Make:- Havells/L&T/ABB/Schneider/Legrand
2
-
-
... More
Supply and fixing in repair MCCB 63 Amps to 125 Amps 4 Pole, 415 Volts steel sheet enclosure, confirming to IEC 60647-2, not less than IP-30 class protection suitable Make- Havells/L&T/ indo asian/ Siemens/ ABB/Legrand
2
-
-
... More
Supply and fixing in repair MCCB 200 Amps to 250 Amps 4 Pole, 415 Volts steel sheet enclosure, confirming to IEC 60647-2, not less than IP-30 class protection suitable Make- Havells/L&T/ indo asian/ Siemens/ ABB/Legrand
2
-
-
... More
Supply and fixing in repair MCCB 320 Amps to 630 Amps 4 Pole, 415 Volts steel sheet enclosure, confirming to IEC 60647-2, not less than IP-30 class protection suitable Make- Havells/L&T/ indo asian/ Siemens/ ABB/Legrand
2
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 100 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / Schnieder / ABB/Siemens
3
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / Schnieder / ABB/Siemens
3
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 320 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / indo asian / Siemens
2
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / indo asian / Siemens
1
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 630 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / indo asian / Siemens
1
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 1000 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / indo asian / Siemens
1
-
-
... More
S&F in repairs Off load changeover with side handle in sheet enclosure 1250 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells/L&T / indo asian / Siemens
1
-
-
... More
Supply & fixing GI tube 50 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge.
40
-
-
... More
S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
1
-
-
... More
M&L for painting of steel tubuler 11/ 9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red/Black strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint and also including numbering of poles with white paint are located on different locations complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
M&L for painting of steel cross arm, bracing supports of 11/9 mtr PCC poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one cement based paint over cemented portion of PCC poles, marking with alternate white and black/red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint and also including numbering of poles complete all as specified and directed by Engr-in-Charge.
150
-
-
... More
S&F in replacement of PVC insulated stranded Copper conductor 1100 Volts grade heavy duty ISI marked twin core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
400
-
-
... More
S&F in replacement of PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked twin core cable flat or circular of size 6 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
300
-
-
... More
S&F in replacement of PVC insulated stranded aluminium conductor 1100 Volts grade heavy duty ISI marked twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
200
-
-
... More
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated copper conductor two core cable flat or circular of size 1.5 sqmm for street light connections etc complete all as specified and direcetd.
500
-
-
... More
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated copper conductor two core cable flat or circular of size 2.5 sqmm for street light connections etc complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 06 Sqmm to 16 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 25 Sqmm to 50 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 70 Sqmm to 95 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 120 Sqmm to 185 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 200 Sqmm to 300 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only aluminium lugs/thimble suitable for LT XLPE cable of 400 Sqmm to 630 Sqmm complete all as specified and direcetd.
100
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 06 Sqmm to 16 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 25 Sqmm to 50 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 70 Sqmm to 95 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 120 Sqmm to 185 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 200 Sqmm to 300 Sqmm complete all as specified and direcetd.
200
-
-
... More
Supply only copper lugs/thimble suitable for LT XLPE cable of 400 Sqmm to 630 Sqmm complete all as specified and direcetd.
100
-
-
... More
Supply only self adhesive PVC electric insulation tape, multicolour (Red,Yellow,Blue,Black),ISI marked, 1-2mm width, 10 meter length suitable for 1100 V complete all as specified and directed.
200
-
-
... More
Supply only HT insulation self amalgamating tape/rubber splicing tape, ethylene propylene rubber, non- adhesive, self sticking,vulcanizing, 09 meter length.], 19 mm width suitable for upto 33 KV complete all as specified and directed. Make - 3M
100
-
-
... More
M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50 mtrs complete all as specified and directed.
20
-
-
... More
M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 10 sqmm to 16 Sqmm 4 core XLPE armored aluminum conductor cable including jointing with copper lugs and ferrules complete all as specified and directed.
2
-
-
... More
Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%