Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date23 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 14,90,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, testing and commissioning of addressable sensor type certified to EN 54 part 1, 58 degree, addressable type microprocessor based, programable inteligent type, blue light optical thermal heat detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc, necessary connection including taking down old unsv sensor complete all as specified and directed.

10

-

-

... More
Supply, Installation, testing and commissioning of addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including, connection including taking down old unsv sensor complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply, Installation, testing and commissioning of addressable intelligence having inbuilt microprocessor, memory and decision alogrithm twin angle with both forward and backward light scattering mechanism cum thermal multicriteria detector (sensor) with heat and smoke combination confirms EN54-5 & FN 54-7 LPCB approved complete including, connection including taking down old unsv addressable intelligence complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply and fixing of maintenance free battery of capacity 12 Volt 7 AH, VRLA AGM type including standard spade terminals connecting and testing at site complete including taking down old unsv battery complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
S&F of PCB of Control panel of existing make including taking down old unsv PCB complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
S&F ONLINE UPS 1 KVA (1000 VA) 6 Volt pure sinewave without in-Built batteries,40-50 Min backup, inbuilt OVCD (over voltage Cut off Device) with surge protection, efficient micro controller based, advanced PFC technology, static bypass-improves reliability, over temperature indication and protection, generator compatible, boost function for low input over voltage protection Extended input voltage range of 135 to 300 volt UPS to battery backup mode including wall mounted stand for UPS of suitable size including taking down old unsv UPS complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&F of addressable manual call with Box with flush mounting glass box resettable type, unique plug and play installation concept, confirm to EN 54-11, LPCB approved, point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and bliking facility complete including taking down old unsv existing manual call point complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply, Installation, testing and commissioning of addressable wall mounting intelligent electronic sounder cum strobe, 32 built-in tones, lower power requirement, optional IP 65 rating, optional built in isolator, Anti tamper feature, CPD approved, LPCB approved in accordance to EN 54 part -3, EN 54 part 17 & CPD including making all connection including taking down old unsv electronic sounder cum strobe complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F of analogue addressable short-circuit Isolator module, operating voltage 15 to 30 Vdc, LPCB approved including taking down old unsv short-circuit isolator complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S&F of unarmoured sheathed twin core twisted cable FRLSH multi stranded copper conductor 1.50 Sqmm 2 core 1100 volts control cable as per IS-7098 and including drawing through on wall/ceiling in rigid PVC conduit medium grade pipe 20 mm dia with all necessary fittings, tee, elbow, u-clip, etc including taking down old cable complete all as specified and as directed. Note : (i) unarmoured sheathed 1.50 sqmm 2 core with one run of PVC conduit pipe 20 mm dia medium grade shall be measured as one unit.

350

-

-

... More
Supply, install, testing and commissioning of active repeater panel for remote monitoring with 1 x 40 character liquid crystal display with backlight illumination, operating voltage 18-32 Vdc, rated voltage 24 Vdc, Alarm current 120 mA, Ambient temprature 5 to 45 deg celcius, dimention 165 x 253.5 x 50 mm and weight should not be exceed 1.7 Kg including taking down old unsv repeater panel complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Taking down any type of detector and refixing the same in existing position after properly cleaning with the help of air blower complete all as directed by Engr-in-Charge. Note : All T&P like ladder, air blower etc shall be provided by contractor and nothing extra shall be payable to contractor on this account.

600

-

-

... More
Supply, Installation, testing and commissioning of floor/surface mounting addressable microprocessor fire alarm control main control panel single loop with BS EN 54 and indicating panel sounder circuits complete with LCD Display and push button to acknowledge alarm, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger,compatible with detector for communication to detectors and 2 x 16 character LCD, confirming to IS : 2189 and BSEN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4' character 2 sounder circuits PTR requires network card and modules (per each loop) etc incl making all connection and fixing accessories including taking down old one complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F of fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured with sound output variation of +5 DB 500 mtrs range including taking down old one complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F of addressable control unit for siren complete with all connection accessories including taking down old one complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and laying of XLPE insulated PVC inner sheathed, armoured LT control cable FRLSH multistranded copper conductor, 1100 volts grade, cross-sectional area 2.50 Sqmm 4 core as per IS 7098 (Part I) 1988 including taking down old cable complete all as specified and directed by Engr-in-Charge.

1000

-

-

... More
Supply and fixing AFO (Auto fire off) plastic fire extinguisher ball (orange colour) which can self active in the presence of fire, active within 3 to 5 seconds upon reaching the appropriate temeprature and extinguish the fire, maintenance free for period 5 years completely harmless to the human body, area cover 360 degree angle, area of about 70 to 80 sqft, which can be extinguish three classes of fire (solid, Liquid and electrical classes), weight 1.50 Kg, 100% eco friendly, 100% bio-degradable along with fixing on wall accessories including taking down old unsv extinguisher complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing Eco fire ABC powder type 6 Kg fire extinguisher (red and black) effective for all type of fire with wall mounted hook, ISI/ BIS marked, ISO & CE certified, multipurpose use with 5 year warranty portable including taking down old unsv extinguisher complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply and fixing Eco fire ABC powder type 9 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable including taking down old unsv extinguisher complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, foundation, etc or for shaft well, cesspits, manholes, pireholes, etc not exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed at site.

330

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays, struts have been erected and tested complete all as specified and directed.

121

-

-

... More
Removing excavated surplus soil obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

179

-

-

... More
M&L for sand cushioning(dry sand) to underground cable for cable protection with layer of 8cm deep before laying the cable and 15 cm depth after laying the cable complete all as specified and directed. Note: Punned thickness of sand layers shall be measured and paid.

100

-

-

... More
M&L for laying of old size sub class B well burnt Brick laid dry flat in trenches over the cable for protection complete all as specified and directed.

9

-

-

... More
Labour only old size sub class B well burnt Brick laid dry flat in trenches over the cable for protection. Note: serviceable old size sub class B well burnt Bricks obtained from item No taking down old cable from item no 19, 31 & 32 shall be reused.

1.6

-

-

... More
Material & labour for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to cross the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. (Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site and all as directed by Engineer-in-charge.

20

-

-

... More
S&F for galvanised water tubing light grade 50 mm dia of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc including taking down old tubing complete all as specified and directed.

20

-

-

... More
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 50 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items)

200

-

-

... More
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 70 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items)

350

-

-

... More
Taking down old foam of fire extinguisher and refilling of ABC powder type, CO2 fire extinguisher, foam type fire in extinguisher cylinder complete all as specified and as directed by Engr-in-Charge. (Note : Contractor shall provide all safety equipment to the person which is refill the Cylinder)

30

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.

5

-

-

... More
Item no 34 contd.... (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe and earth lead wire for protection of earth wire/strip. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.