Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Oct 2024
Closing Soon21 Nov 2024
Tender Amount₹ 47,78,000
Costs
EMD
₹ 95,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680304_1Tender No
GE(I)/KAN/T-82 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
All as per item No 3 above but for 22 G complete all as specified & directed.
400
-
-
S&F of insulation in ducts including accessories complete all as specified & directed.
650
-
-
S&F Acoustic insulation including accessories complete all as specified & directed.
120
-
-
Supply, fixing installation and testing of extruded powder coated air Grill made out of GI wire mesh for discharge of exhaust air from exhaust fans complete all as specified & directed.
19
-
-
Supply and fixing of 3 phase 415 volt 50 Hz venticool protector Panel having overvoltage cut off limit 480V+/-2% and undervoltage cut off limit 350 V+/- 2% On time 1 to 120 sec including all accessories complete all as specified & directed.
21
-
-
Supply and fixing of MS frame stand of required size for AHU Complete all as specified & directed.
Note for Item Nos 1 to 9:- The work shall be executed by OEM of the air cooler.
21
-
-
Supply & fix PVC insulated flexible copper conductor cable of size 2.5 sqmm 3 core cut to pieces as required at site for connection with proper thimbles, pole complete all as specified & directed.
850
-
-
Supply& fix exhaust fan steel body AC single phase 230V/240V of size 450 mm sweep with blade, and frame & louver with cavity complete all as specified & directed.
34
-
-
M&L for Earthing with galvanised iron earth plate electrode of size 600x600x6mm thick with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers including providing earth wire protection with GI light grade pipe of size 15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, excavation, earth work in any type of soil and removal of surplus excavated material from site all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.
10
-
-
Supply,Laying, jointing and leakage testing of GI Pipe medium grade of size 15 mm bore including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches / floor/ walls etc complete all as specified and as directed :-
Notes : (i) The laying and jointing of pipes are required to be carried out in short / long streches catering to specific requirements of a purticular quarter, building block or a group of blocks.)
350
-
-
Rotational moulded polythelene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed position complete all as specified & directed
21
-
-
S&F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size of copper bus bar and neutral link, including one MCCB 4 pole 415 Volts 125Amps rating with rapturing capacity of 16 KA of the same make of distribution board & with MCBs of required capacity making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as required at site or directed by Engr-in-Charge.
3
-
-
S&F isolator TPN 415 volt 3 phase 63 amp with enclosure box complete all as specified & directed.
21
-
-
Supply and fix sheet metal enclosure MCB distribution board 4 way, double door with IP-43 protection with 200 Amp rated bus bar complete all as specified & directed.
22
-
-
M&L for MCB single pole 240 volts 6 to 32 amps, C curve with rapturing capacity of 10 KA using thimbles of required size complete all as specified & directed.
44
-
-
M&L MCB single pole & neutral 240 volts 63 amps, C curve with rapturing capacity of 10 KA using thimbles of required size complete all as specified & directed.
22
-
-
Supply and laying on wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sqmm nominal cross section 4 core in service connections complete all as specified and directed. (Note : Including making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
170
-
-
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified & directed.
37.8
-
-
Returning filling, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified & directed.
26.18
-
-
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed.
11.62
-
-
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified & directed.
Note:- Punned thickness shall be measured and paid.
11.34
-
-
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified & directed.
1.12
-
-
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade of size 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
300
-
-
M&L for point wiring for one light point/bell point/exhaust fan point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper colour coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green colour) as earth lead in and including concealed non metalic rigid PVC conduit medium grade of size not less than 20mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified & directed.
20
-
-
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified & directed.
20
-
-
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified & directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%