Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 38,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.

187.92

-

-

... More
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/length wise perpendicular to the axis of cable all as specified & directed.

14560

-

-

... More
Labour only for Laying old bricks complete all as specified and directed. Note Bricks obtained from Srl item No 5 shall be used under this item.

4000

-

-

... More
Taking out old defective cable from trenches/ floor/road/wall/pipe/pole /service connections of any size , testing with LT magger , seggregating the serviceable part of cables and store for relaying complete all as specified & directed by Engr-in-charge.

2900

-

-

... More
Supply and laying of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 2 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.

460

-

-

... More
All as per Ser item No 8 here-in-before but 10 Sq mm 4 core

180

-

-

... More
All as per Ser item No 8 here-in-before but 16 Sqmm 2 core

220

-

-

... More
All as per Ser item No 8 here-in-before but 16 Sq mm 4 core

320

-

-

... More
All as per Ser item No 8 here-in-before but 25 Sq mm 4 core

350

-

-

... More
All as per Ser item No 8 here-in-before but 50 Sq mm 3.5 core

150

-

-

... More
All as per Ser item No 8 here-in-before but 95 Sq mm 3.5 core

250

-

-

... More
All as per Ser item No 8 here-in-before but 120 Sq mm 3.5 core

450

-

-

... More
All as per Ser item No 8 here-in-before but 185 Sq mm 3.5 core

200

-

-

... More
All as per Ser item No 8 here-in-before but 240 Sq mm 3.5 core

220

-

-

... More
Relaying only serviceable LT UG Cable obtained from Srl item No 07 of any size and discription including necessary cable lugs complete all as specified and as directed. Note :- ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)

100

-

-

... More
M&L for Straight through joints heat shrinkble type 1.1 KV for PVC insulated and sheathed aluminium conductor under ground cable of size 25 to 50 sqmm 3.5 / 4 core including testing of joints after completion complete all as specified and as directed.

12

-

-

... More
All as per Ser item No 19 here-in-before but 120 to 185 sqmm 3.5 core complete all as specified and as directed.

8

-

-

... More
All as per Ser item No 19 here-in-before but 240 sqmm 3.5 core complete all as specified and as directed.

2

-

-

... More
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.

10

-

-

... More
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.

50

-

-

... More
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. 50 mm dia

20

-

-

... More
All as per Srl Item No 24 above 80 mm dia complete all as specified & directed.

20

-

-

... More
All as per Srl Item No 24 above 100 mm dia complete all as specified & directed.

10

-

-

... More
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 36 KA incl making connection /thimbles complete all as sepcified and directed

5

-

-

... More
M&L for stay assembly complete with accessories and fittings of diameter of stay rod in 20 mm including earth work complete all as specified and directed by Engineer -in-Charge.

2

-

-

... More
Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge.

2

-

-

... More
Dismantling of LT PCC/steel tubular pole incl coping, foundation etc and serviceable insulators from poles for reuse and shifting of poles to E/M yard or any other location complete all as specified and as directed

10

-

-

... More
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.

10

-

-

... More
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.

3

-

-

... More
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.

6

-

-

... More
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.

2

-

-

... More
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed.

2

-

-

... More
Dismantling insulators any type any size from LT poles complete all as specified and directed.

20

-

-

... More
M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia. complete all as specified and directed.

20

-

-

... More
Dismantling of ACSR from the poles all as specified and directed by Engineer -in-Charge.

1

-

-

... More
M&L Aluminium conductor, steel reinforced incl stringing in position all as specified and directed by Engineer -in-Charge.

1

-

-

... More
M&L for earthing complete with galvanised iron steel earth plate of size 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthing by means of nuts bolts check nuts and washers made of galvanised iron or steel earth wire protected by galvanised iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 5 of SSR Part-I including testing on completion all as specified and directed.

15

-

-

... More
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground complete all as directed.

150

-

-

... More
Material and labour for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises complete all as specified and as directed.

800

-

-

... More
S&F of PVC LT OH line spacer for 5 wires complete all as specified and directed.

20

-

-

... More
S&F of PVC LT OH line spacer for 4 wires complete all as specified and directed.

30

-

-

... More
S&F of PVC LT OH line spacer for 3 wires complete all as specified and directed.

20

-

-

... More
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge.

5

-

-

... More
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed.

80

-

-

... More
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: 1. Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. 2. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.

500

-

-

... More
Disconnection of electric connection from LT Panel of any size dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including all inter connection with aluminium strip of size not less than 0.6Mx0.03Mx6MM 1100 volts grade and suitable current rating including painting of Panels complete with inner & outer with two coats of synthetic enamelled paint over a coat of primer including excavation & earth work required for taking out & refixing the incoming and out going cable etc complete all as directed by Engr -in Charge; Note :-Replacement of unserviceable accessories parts shall be measured and paid separately under relevent items.

4

-

-

... More
S&F in replacement MCCB 415 Volts 4 pole 400 Amps 50 Hz 50 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
S&F in replacement of unserviceable parts of LT Panels complete all as specfied and as directed.

-

-

-

... More
S&F MCCB 250 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz complete all as specfied and as directed.

12

-

-

... More
S&F 200 Amp 36 KA 4 pole adjustable type 415 Volts 50 Hz complete all as specfied and as directed.

14

-

-

... More
S&F MCCB 125 Amp 25 KA 4 pole adjustable type 415 Volts 50 Hz complete all as specfied and as directed.

6

-

-

... More
S&F MCCB 63 Amp 16 KA 4 pole 415 Volts 50 Hz complete all as specfied and as directed.

10

-

-

... More
S&F Aluminium bus bar 600 Amp with colour code & porcelain insulator complete suitable for 3 phase 4 wire system of length not less than 1 Mtr.

2

-

-

... More
S&F Phase Indicator lamp RYB complete all as specfied and as directed.

2

-

-

... More
S&F Volt meter 0-500 Volts with selector switch complete all as specfied and as directed.

2

-

-

... More
S&F Amp meter 0-600 Amp with selector switch complete all as specfied and as directed.

2

-

-

... More
S & F Rubber Mat of size 2mtr x 1mtr x 12mm at Elect Supply installations complete all as directed by Engr in Charge

12

-

-

... More
S&F in replacement 1100 volts grade PVC insulated aluminium conductor screened served with inner sheathed in service connection flat twin core cable of size 10 sqmm complete all as specified and directed.

2500

-

-

... More
All as per Ser item No 61 here-in-before but 06 sqmm complete all as specified and directed

3000

-

-

... More
Note : (i) Complaints pertaining to LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 1000/- per day per complaint shall be imposed from the contractor.(ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (iv) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.