Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jan 2025
Closing Soon13 Feb 2025
Tender Amount₹ 12,00,000
Costs
EMD
₹ 24,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693384_1Tender No
8409/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
6
-
-
... More
Supply and laying un-reinforced precast concrete cable cover, type-1, flat, size 300mm x 180mm x 40mm over the cable after spreading the sand for cable protection complete all as specified and directed.
250
-
-
... More
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including necessary form work for foundation filling and mass concrete complete all as specified and directed.
1
-
-
... More
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary form work for foundation filling and mass concrete complete all as specified and directed.
1
-
-
... More
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) including necessary form work for foundation filling and mass concrete complete all as specified and directed.
1
-
-
... More
Cutting and chassing or boring as required in hard standing,PCC, Road exceeding 10 cm girth for concealed to GI tubing and making good to disturbed surface with cement mortar 1:3 to match with existing surfaces including facing/finishing where as required and as directed by GE(I).
6
-
-
... More
Supply & laying in replacement GI tubing of 80 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.
6
-
-
... More
Taking down/out existing worn out/old HT UG cable of XLPE / PILCA insulated, armoured, aluminium conductor cable any size in pieces from pole, trenches culvert, pipe making loop for transportation and removal from site after taking proper shut down from MES competent staff complete all as directed.
120
-
-
... More
Supply laying jointing and testing HT XLPE Insulated , Screened PVC bedded ,galvanised steel strip or wire armoured electric power cable(heavy duty) with aluminum conductor 11000 volt (E) grade cross sectional area 95 sqmm 3 core confirming to IS-7098 (Part I ) of 1988 laid in trenches/Duct on pole witth FI CLAMP, Nut bolt ,Aluninum Lugs complete all as specified and directed at site. Make : Havells/Grandlay/polycab
Note- Joints will be measured and paid seprately.
120
-
-
... More
M&L for heat shrinkable type cable end joint indoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed.
Make : Denson/ Raychem/ M - seal as approved by GE (I).
3
-
-
... More
M&L for heat shrinkable type cable end joint outdoor type suitable for XLPE 95 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed.
Make : Denson/ Raychem/ M - seal as approved by GE (I).
4
-
-
... More
All as above item No 14.00 but straight through joint Heat shrinkable 95 sqmm 3 core 11 KV
2
-
-
... More
Supply, fixing and connecting in replacment single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge corrent 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified.
Make : Cromption Greaves type ZLAX 15 / Southern Insulators/ Alpro International as approved by GE. Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.
1
-
-
... More
M & L for Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 32x6mm GI strip up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt .
Note : Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate.
10
-
-
... More
Supply and topping up of insulating oil/pure hydrocarbon mineral oil, clean and sufficiently free from moisture and of other foreign matter as per ISS-335-1993 (fourth revision) incorportingup to date amendment of breakdown/value 60 KV or over at stndard gap after filteration for topping up upto required level in transformers & switchgears and PT's etc complete all as specified and directed and additional characteristics as indicated below :-
(a) Oxidation Stability.
(i) Newutralizatin value after oxidation max 0.4mg. KOH/Gm.
(ii) Total sludge after oxidation max 0.01% by weight.
(b) Break down value 60 KV or over at standard gap
(c) SK value upto 8% Make : APAR (POWER OIL)/CASTROL.
200
-
-
... More
Labour charge for filteration and dehydration of Transformer oil for 33/11 KV power transformer with stream line mobile filteration plant at a temp from 60-75 degree celsius to achieve the dielectric strength of oil not less than 60 KV for one minute at a standard gap as per IS 335 of 1983 to remove the moisture from winding and core complete all as specified and directed .
Note : Filteration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost.
1200
-
-
... More
Calibratin, performance testing with necessary adjustment of over current/earth fault /earth leakage/ACB in 11 KV panels by artificial high current/capacitive synthetic current injection test on as per IS 14658: 1999 or IS 13516 : 1993 to check tripping mechanism of HT combined inverse time over current and instantaneous relay and cleaning/decobonising its moving and fixed contacts and to ensure physical healthiness with visual check for healthy tripping of over current and earth fault, adjust tripping time, ratio setting, instantaneous time setting, delay time etc as per installed capacity of transformer with considering of percentage impedance of transformeers for successful operation at the time of fault occurence complete all as specified and directed.
3
-
-
... More
M&L for preparing, scraping old painted surfaces and applying two coat of aluminium paint on HT steel tubular swaged poles and swan neck , bracket. channels, angles including making/pasting three nos circular strips of 300 mm wide with reflected synthetic enamel paint (100 mm width each strip for HT pole 03 strips of red colour ) and marking/stencil writing of pole numbers with black paint complete and all as specified and directed.
Make of paint : Asian/ Burger/ Nerolac as approved by GE (I).
10
-
-
... More
M&L transformer silica gel breather complete with all accessories for transformer of any capacity up to 400KVA transformer all as directed at site
2
-
-
... More
M&L transformer silica gel for transformer of any capacity all as specified and directed.
4
-
-
... More
Supply & fixing in replacement of Off load Tap Charger switch, oil immersed of transformer of capacity 300/400 KVA, 11/0.433 KV, 3 Phase 4 wire, 50 Hz, vector group-Dyn 1, on HV winding by making taps on it properly in such a manner that the contacts of all the three windings are changed simultaneously to change + 2.5% + 5% + 7.5% + 10% to control the flow of KW and KVAR & maintain voltage at consumer end as per I.E. rules complete all as specified and directed.
1
-
-
... More
Disconnecting/dismantling in position minor servicing/overhaul of 11 KV distribution transformers 100KVA to 400 KVA capacity for any type of leakage/defect at LT/HT bushing, gasket, drain plug etc., after disconnecting of electric supply and earth connections, drain out transformer oil and keeping in close containers for re-use, lifting/removing of top cover of transformer if it requires, re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers, as required at site, re filling of Transformer oil, complete after electric connections and testing all as specified and directed by Engr-in-Charge.
Note :- (i) If retrieved transformer oil's di-electric strength is very less than it will be replaced with new one in relevent items.
(ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemed to be included in the unit rates.
1
-
-
... More
Transportion the defective transformer sefly from yard to workshop and return back after repair the transformer with loading and unloading to vehicle from required crane and safe fixing in the plinth without any damage to transformer all as required and directed ( Note : Quoted rate will be for shifting the workhshop up to 100 Km from the yard to workshop and return.)
1
-
-
... More
Opening of transformer 160 to 400 KVA capacity 11 /0.415 KV top cover and all other connected accessories ie conservator temprature and oil indicator and other connected items after opening the nut bolts and taking out the plate by crane and required T&P and electrical connection complete after taking out the old used transformer oil complete with all as required and directed at site
1
-
-
... More
M&L for inspection ,rewinding and testing of wornout three phase power transformer of 160 to 400 KVA 11 KV/0.415 KV 50 HZ Vector group -DYN II by taking out the /lifting the winding core /coil care fully according to manufacturer instruction with disconnecting the internal connection for its inspection and taking out the defected/worn out winding wire/strip and rewinding the copper coil with strip/wire coated with insulated varnish ,double paper covered of existing gauge assembled on limbs of the core , first LV winding (star) is assembled and HV widing is asssembled over both winding are insulated from core and main tank by providing sufficient electrical insulation ing cotton tape spacers, wooden block etc , ovening the coil for demoisturising and drying the winding core and main tank cleaning the empty tank by removing dirty sediments ,wash with warm oil , chek the dain cock for workability and assembling the complete core with tightening the nut bolts complete all as required and directed at site.
150
-
-
... More
Reconditioning the LV coil of worn out transformer with insulating material all as required and directed complete all as requied
100
-
-
... More
Supply the packing set of any size suitable for transformer of capacity 160 to 400 KVA made out of 10 mm/6mm thick cock sheet single piece including removing old unserviceable packing kit/ set cleaning the surface of the top cover gasket inspection kit,radiator fins,vent pipe and bucholz and other part of transformer and other part all as required and directed at site.
1
-
-
... More
Providing the crane of appropriate capacity to lift/lowering the core assembly and top cover alongwith conservator for saftey of core assembly and other part for fixing in tank after repair of assembly all as required and directed at site.
1
-
-
... More
Refixing the transformer 160 to 400 KVA capacity top cover and all other connected accessories ie conservator temprature and oil indicator and other connected items and tightening the nut bolts and cleaning the radiator ,testing commissioning complete transformer and fixing on plateform after unloading transformer making the connection with testing the transformer with qualified engineer complete all as required and directed at site.
1
-
-
... More
M&L for providing re-insulation like cotton tape/paper insulation on LT side of strip winding and resetting the same in existing position and fixing the transformer core assembly in transformer housing/tank, making complete internal electric/mechanical connections, replacement of old sleeves, bolts, nuts, washers/wires, hooks etc. including tightening of all loose connections complete all as specified and as directed by Engineer in Charge
10
-
-
... More
M & L for painting of OCB/VCB by means of spray painting with two coat of synthetic enemal grey paint including marking with stancile of capacity, location, MES No etc after cleaning of transformer complete by thiner and preparation of surface of transformer body, cable end box etc complete all as specified and directed.
Make of paint : Asian/ Burger/ Nerolac as approved by GE (I).
4
-
-
... More
S&F in replacement of unserviceable brass spindle duly threded at the end complete with nut bolts and washer suitable for HT side of transformer out door type all as specified and directed at site for the following capacity suitable for existing transformer of required size/ shape for spindle of transformer of any capacity up to 400KVA 11000 volts grade indoor type suitble for HT side all as specified and directed :- 160 KVA
1
-
-
... More
All as per ser item No 35.00 above but 400/300 KVA
1
-
-
... More
All as above item No 35.00 but suitable for LT side of transformer of following capacity :- 160 KVA
1
-
-
... More
All as per ser item No 37.00 above but 400/300 KVA
1
-
-
... More
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 1.1/ 6.6 /11 KV XLPE/PILCA insulated LT/HT cable complete all as required and directed at site
1
-
-
... More
S&F in replacement of unserviceabile porceline vitreous bushing of required size / shape (suitable for exisiting transformer ) for spindle of transformer of any capacity upto 400 KVA 11KV indoor type siutable for HT side all as specified and directed
2
-
-
... More
All same as per item No 40.00 above but 1100 Volts grade suitable for LT side indoor type
2
-
-
... More
Dismantling existing worn-out old GOD and fixing only 11 KV out door type gang operated air break switch triple pole & Disconnecting from existing system and Supply and installation and testing 11 KV outdoor type ,gang operated Air-break switch triple pole mechanically operated ,mounted on insulator and steel frame with operating mechanism worked from ground level with 25 mm GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 200 amps with dropout fuse & 12 insulator connected and out going with Steel nut bolts and washers all as specified and directed at site.
1
-
-
... More
Routine and periodical work required for trimming / cutting of tree branches of any girth, touching /obstructing the over head lines of HT/LT poles of three phase distribution system at places not more than 40 mtr span distance so as to keep minimum 2.0 mtr clearance all around the lines and poles with due care after taking proper electric shoutdown from concern MES competent staff complete disposal thereof ( trimmed branches) to a distance not exceeding 100 metre complete all as specified and directed.
50
-
-
... More
Routine and periodical cleaning around the area of out door swith yard of 11 KV Sub Station No 1 and 11 KV sub stn No 2 etc by cutting and removal/uprouting of unwanted grass/bushes, small trees including surface dressing and leveling by surface excavation wherever required complete in all respect or as directed.
600
-
-
... More
Supply & fixing in replacement of DO fuse element of current rating 20 to 40 Amp in fire resistance tube suitable for working voltage of 11 KV complete all as specified and directed.
20
-
-
... More
Supply & fixing in replacement of HT tape suitable for working voltage of 11 KV complete all as specified and directed. Make : Johnson/scotch or equivalent.
20
-
-
... More
Providing highly skilled mechanic/ specialist in electric HT breakers/Panels line certified from OEM ( Original Equipment Manufacturer) for carrying out the mechanical servicing/overhauling of 11 KV VCB/SF6 breaker complete (Make-CG/ALSTOM/ABB /OR ANY MAKE ) by drawing out the trolly from existing HT panels with due care after taking proper shut down from concerned staff, opening of l tank, decanning of old carbonised parts and cleaning/decarbonising all mechanical/metal parts with CRC/CTC-226 solution/spray, inspection/ checking of all fixed and moving parts, dressing of male and female contact by using emery paper for fine/smooth contact, meggering of IR value of all HT incoming and out going bushing, providing oil, grease and re-assembling the same by tightening of all connections including checking of alignment for easily movement of breaker for ON/OFF operation with setting of buffer gap adjustment, contact travel allignments , rollar gap , hard or light setting of breaker greasing of all moving mechanism including removing and fixing worn out/cracked/moistured/loosing IR value spare parts ( for which supply of spare parts only will be paid seperately )and fixing the trolly in HT panels and testing, charging the system in presence of Engr in Charge/JE E/M complete all as specified and directed.
4
-
-
... More
Supply and fixing Auxilariy Switch 7NO+ 7NC suitable for existing panel complete all as specified and directed.
2
-
-
... More
Supply and fixing Close coil 24/30V DC suitable for existing panel complete all as specified and directed. Greave/ABB
2
-
-
... More
Shunt trip coil 24/30V DC.suitable for existing panel complete all as specified and directed.
2
-
-
... More
Supply and fixing Series trip coil 24/30V DC. suitable for existing panel complete all as specified and directed.
2
-
-
... More
Supply and fixing Power Pack suitable for HT panel /VCBcomplete all as specified and directed.
2
-
-
... More
Supply and fixing of Vaccum intrupter complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of led light R,Y,B as specified and directed
9
-
-
... More
Supply and fixing in replacement of T&C swithch as speciifed and as direected at site
2
-
-
... More
Supply and fixng in replacement of spout HT, suitbale type of VCB as specified and as directed at site
8
-
-
... More
S & F CT (set of three) for 11 KV indoor VCB, draw out type, 11 KV11000/110V,VA5, Class I Rated, freequency 50 Hz.or as per existing Make CG,PRAGATI,National or equivalent
1
-
-
... More
S & F PT (voltage transformer) for 11 KV indoor VCB, draw out type, 11 KV11000/110V,VA5, Class I Rated, freequency 50 Hz or as per existing. Make CG,PRAGATI,National or equivalent
1
-
-
... More
S&F in replacement of male female contacts suitable for existing type of VCB suitable for existing panel complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of geary mechanicsm as per existing of VCB for complete all as specified and as directred at site
1
-
-
... More
Supply & fixing in replacement of worn out IDMP relay by Three Phase Over Current + Earth Fault Digital Protective Relay with high set, CT operated of rating 5.0 Amp, auxilary voltage 24 -240 V AC/DC , out put contacts-02 NO + 02 NC, selectable Fielf type, fixed in 11 KV HT panel including cutting slot in existing MS sheet of HT panel, if required and making internal control circuit service connection with FR PVC insulated copper wire of size not less than 2.5 sqmm including calibration, performance testing with necessary adjustment of over current /earth fault/earth leakage by artificial high current/capacitive synthetic current injection test on primary/secondary side as per IS-14658 : 1999 or IS 13516 : 1993 to check the CT ratio and polarity and to ensure physical healthiness with visual check for healthy tripping of over current and earth fault by adjustment of tripping time, flag setting, ratio setting, instantaneous time setting, delay time etc as per installed capacity of transformer with considering of percentage impendance of transformers for successful operation at the time of fault occurence complete with providing standby electric supply for testing complete all as specified and directed. Model No MC 61A, Cat Part NO MC61ANX2200 of Make -L&T / Secure/Siemens/Areva/Kaycee/HPL as approved by GE (I).
2
-
-
... More
M & L for painting of transformer 11 KV, upto 400 KVA by means of spray painting with two coat of synthetic enemal grey paint including marking with stancile of capacity, location, MES No etc after cleaning of transformer complete by thiner and preparation of surface of transformer body, cable end box etc complete all as specified and directed.
Make of paint : Asian/ Burger/ Nerolac as approved by GE (I).
4
-
-
... More
S&F danger board for HT/ LT pole equipments made out of MS sheet not less than 1.6mm thick vitreous enamelled with letters figure and size of board 200mm x 150mm including mild steel work for fixing danger board complete all as directed.
6
-
-
... More
Supply, fixing, connecting and testing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps including replacement of connection lead of suitable size with suitable lugs/ clamps complete all as specified and directed.
1
-
-
... More
Labour work required for restretching/restringingof existing loos/sagged ACSR/GI Conductor of HT/LT OH lines of three phase distribution system by opening binding wire from insulator as fixed on pole and restring OH Line with proper binding with insulator by using additional binding wire/conductor not less than 2.0 mm dia with due care using safety belt etc after after taking proper electric shut downfrom concern JE E/M complete all as directed by Engr-in-charge.
300
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%