Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Jan 2024
Closing Date21 Feb 2024
Tender Amount₹ 47,00,000
Costs
EMD
₹ 94,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_638405_1Bid Award Id
ViewTender No
8012/1004/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
- do- all as above item No-2 but one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
240
-
-
- do- all as per item No-2 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item No. 2 to 5-: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
180
-
-
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one No. MCB SP of capacity 20 Amps 240 volts complete all as specified & directed.
20
-
-
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed.
1500
-
-
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed.
440
-
-
Supply and fix switch piano, flush type, single pole, 20 Amps one way, 230 volts complete all as specified and directed.
180
-
-
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed.
180
-
-
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed.
30
-
-
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
800
-
-
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
250
-
-
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed.
220
-
-
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.
30
-
-
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
200
-
-
- do- all as per item No-16 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.
50
-
-
- do- all as per item No-16 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
80
-
-
- do- all as per item No-16 here in before but point wiring for one six pin socket outlet 15 & 5 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed. NOTE for item No. 16 to 19-: (i) the new metal flush mounting sunken boxes and its covering plates etc shall be measured and paid for separately under respective item of this schedule. (ii)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (iii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iv)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
50
-
-
Supply and fixing modular metal GI flush box 1/2 module as per site requirement suitable for 20mm dia conduit with and fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.
Make:- Legrand/Crabtree/Anchor/Plaza/Cona as per sample at site.
30
-
-
All as above item No -20 but modular metal flush box of 3 module complete all as specified and directed.
130
-
-
All as above item No -20 but modular metal flush box of 4 module complete all as specified and directed.
50
-
-
All as above item No -20 but modular metal flush box of 6 module
20
-
-
All as above item No -20 but modular metal flush box of 12 module
20
-
-
All as above item No -20 but modular metal flush box of 18 module
10
-
-
Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc complete all as specified and directed.
10
-
-
All as per above item No. 26 But modular white cover plate with frame 2 module complete all as specified and directed.
20
-
-
All as per above item No. 26 But modular white cover plate with frame 3 module complete all as specified and directed.
130
-
-
All as per above item No. 26 But modular white cover plate with frame 4/5 module complete all as specified and directed.
50
-
-
All as per above item No. 26 But modular white cover plate with frame 6 module complete all as specified and directed.
20
-
-
All as per above item No. 26 But modular white cover plate with frame 2x 6 module complete all as specified and directed.
30
-
-
All as per above item No. 26 But modular white cover plate with frame 3x 6 module
20
-
-
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
10
-
-
Supply and fix in replacement switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
330
-
-
Supply and fix in replacement socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed.
130
-
-
Supply and fix in replacement switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed.
50
-
-
Supply and fix in replacement socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed.
50
-
-
Supply & fix in replacement rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed.
30
-
-
Supply & fix commiosnig and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed.
20
-
-
Supply and fixing LED Bulb 15 watt suitable for lamp holder complete all as specified and directed.
250
-
-
Taking down existing old/ U/S sub main wiring along with fitting/fixtures existing of any type and description, removal of teak wood batten/ PVC pipe/ PVC casing & caping and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified and directed.
1430
-
-
M&L for in replacement of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.
Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
650
-
-
M&L for in replacement of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.
Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
730
-
-
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 10 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
50
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections uspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core of size 10.0 Sqmm cable flat or circular compele all as specified and as directed by Engr-in-Charge.
200
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections uspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core of size 6.0 Sqmm cable flat or circular compele all as specified and as directed by Engr-in-Charge.
200
-
-
Supply and fix in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .
18
-
-
Supply and fix in replacement MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 200 standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB but with enclosue blank plate complete all as specified and directed .
20
-
-
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed.
30
-
-
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 200 amps rated bus bar 240 volts complete all as specified and directed.
15
-
-
Supply and fix in replacement MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB.
18
-
-
Supply and fixing in replacement miniature circuit breaker (MCB) TPN 40 to 63 Amp, 4 poles, 415V 10KA 'C' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning., complete all as specified & directed.
20
-
-
Supply & fix in replacement MCB SPN, 40 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed.
45
-
-
Supply & fix in replacement MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
396
-
-
Supply & fix in replacement MCB SP, 6 to 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed.
210
-
-
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.
320
-
-
Supply & fix in replacement, outdoor street light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
120
-
-
Supply & fix in replacement, surface mounting type bulkhead 10 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
50
-
-
Supply & fix, surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2ftX2ft (600mm x 600mm) environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.
150
-
-
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
50
-
-
Supply & fix in replacement, surface round mounting type 12/15 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
.
30
-
-
Supply & fix in replacement, surface square mounting type 12 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
30
-
-
Supply & fix NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 65 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
10
-
-
Supply and fixing of bollard light fitting suitable for 09 to 12 Watts LED Bulb/ light fully cast aluminum body finished with polyurethane paint (with prior treatments) bollard of length 755 mm (29.75 Inches) & circular base diameter of 177 mm (7 Inches) and max diameter of leg of bollard 76 mm (3 Inches) surmounted with aluminium sheet spray painted canpoy & transparent improted acrylic cover with 5 Louvers duly stacked duly pipe mounted on cast aluminium spigot as per IS 10322, B-22 ABS holder alongwith lamp lock device. Total Length of fiting 349 mm (13.75 Inches) and Max Breadth of fitting 304 mm (12.0 Inches) total length of bollard fitting 1104 mm (43.5 Inches).
30
-
-
S & Laying,jointing,commissioning and testing XLPE insulated steel armoured heavy duty elect power cable 1100 volt grade, stranded aluminium conductor 4 core 25 sqmm laid in trenches or fixed to wall with saddles or layed in duct or passing through pipe for making electrical connection between LT panel/ feeder pillar box and DBs compele all as specified and as directed by Engr-in-Charge.
170
-
-
S & Laying,jointing,commissioning and testing XLPE insulated steel armoured heavy duty elect power cable 1100 volt grade, stranded aluminium conductor 4 core 16 sqmm laid in trenches or fixed to wall with saddles or layed in duct or passing through pipe for making electrical connection between LT panel/ feeder pillar box and DBs compele all as specified and as directed by Engr-in-Charge.
160
-
-
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
77.27
-
-
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
45.28
-
-
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
32
-
-
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable.
1945
-
-
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
23.18
-
-
Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,.
12
-
-
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4 mm galvanised iron or steel strip.
250
-
-
S&F in replacement of Air termination, single pointed rod 25mm dia and 1800mm long of GI on Hanger roof at height upto 11 mtr with necessary arrengment for fixing on roof with insulating material of minimum 6 mm thick PVC insulation between roof structure amd air termination point including necssary screws, nuts, bolts & washer of GI with suitable size base plate to fixed in a manner to insure non conductivity with bldg structure complete all as directed and specified Note:- Rate is inclusive of specilised ladder having requirement upto 11.0 mtr hanger height
20
-
-
S&F in replacement of GI strip 32x6 mm with saddles/insulators and fixing screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors above ground on Hanger at height upto 11 mtr all as directed and specified.
80
-
-
S&F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw all as directed and specified.
40
-
-
S&F in replacement aluminum strip 25 x 3 mm with saddle of porcelain insulator and fixing screws not less than 50 mm long with PVC plug & gutties etc. on roof/wall and connecting from earth pit the lightning rods point on Hanger at height upto 11 mtr etc all as specified and directed
800
-
-
Refixing of hanging Aluminium/GI strip on same location with saddles/insulators, screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors on Hanger at height upto 11 mtr all as specified and directed
800
-
-
Supply and fixing GI Pipe 50mm Light grade , for Earth strip protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,.
20
-
-
M&L for earthing in replacement complete with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements