Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Housekeeping Services
Eprocure
Opening Date13 Nov 2024
Closing Date28 Nov 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683568_1Tender No
8012/1078/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No.3 above but capacity of sump 20000/25000 gallons.
2
-
-
All as per item No. 3 above but capacity of sump 50000 to 70000 gallons.
4
-
-
All as per item No. 3 above but capacity of sump 100000 gallons.
2
-
-
All as per item No. 3 above but capacity of sump 200000 gallons.
5
-
-
All as per item No. 3 above but capacity of sump 350000 gallons.
3
-
-
All as per item No. 3 above but capacity of sump 400000 gallons.
2
-
-
All as per item No. 3 above but capacity of sump 800000 gallons.Note for item No 01 to 10 : (a) Removal of remaining sludge from the flor with the help of industrial vacuum cleaner : (b) Removal of remaining sludge with the help of imported heavy duty industrial vacuum, cleaner and sludge sucker having max power of 1200 watt with suitable heavy duty rugged motor.
(c) Imported sludge sucker should be a part of the high pressure system which sucks and throws the same out of the tank this must handle solid partials as well.
(d) All safety gadgets like safety bells, special safety belts, special safety ladders helmets, heavy duty gum boots, electric safety gloves and special working gloves saftety masks, aprons etc. for complete security and operation be used by well trained person.
1
-
-
S&F in repairs aviation obstruction light luminaries fittings having integral LED aviation light comprising of aluminium housing with polycorbonate enclosure at the top of OHT and making necessary electric connection and fixing arrangement of aviation lights complete all as specified and directed.
10
-
-
S&F in repairs electronic water level indicator,5 stage, showing 0%, 25%, 50%, 75% & 100% (Sensor system with LED display) complete all as specified and directed.
15
-
-
S&F in repair on wall/surface or on top of over head tank or laying in trenches PVC insulated 1.5 Sqmm, 3 core copper conductor 1100 Volts grade cable drawn through PVC conduit pipe of 20mm dia complete all as specified and directed.
180
-
-
All as per item No. 13 above but 1.5 Sqmm, 06 Core.
300
-
-
S&F in repair pressure gauge, 100mm dia of scale 0 to 7 Kg/cm2 with FI clamp of size 25 x 3 mm and 15mm socket complete all as specified and directed.
15
-
-
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm size, buried directly in ground (earth pit not less than 3.25M deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to and including galvanized steel earth strip 32 x 6mm, including 40mm bore GI light grade protection pipe as earth lead strip connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150mm thick alternate layers of charcoal or cock dust & common salt 20mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) cover 50mm thick of precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8mm deformed or twisted bars @ 100mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/loose soil and deposited the surplus soil to a distance n.exc 50mtr away from starting point complete all as specified and shown in electrical plate No 3 of MES standard schedule of rates 2009 Part-I all as specified and directed.
23
-
-
Supply and fix in repairs air terminal single pointed aluminium rod 12mm dia and 300mm long including taking down of old existing terminal all as specified and directed.
15
-
-
S&F in repairs test point terminal block made of gun metal or phosphoras bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25mm long, head screw complete including taking down of old existing test point all as specified and directed.
14
-
-
Supply and fix in repairs aluminium strip 25x3 mm with saddles and fixing screw etc for roof and down conductors and above ground complete including taking down of old existing all as specified and directed.
140
-
-
Supply and fix in repairs GI strip 32x6mm buried in ground including taking out/down old existing strip all as specified and directed.
150
-
-
Supply and fix in repairs galvanised iron pipe of 50mm bore 'medium grade' including fittings complete including taking up/down old pipe complete all as specified and directed.
30
-
-
M&L for Mild steel, plain, black sheet 1.25mm thick in hearths; covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required.
40
-
-
Supply, fabrication and fixing of MS channel/Angle'C' section etc conforming to GDE FE 410- W as hip and jack rafter, purlins,ladder ect where connected to common rafters and running rails fixed with other connecting plates ect including necessary welding, cutting etc and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
1600
-
-
Sampling and testing of water for the conformation of Desirable / permissible limit of following requirements for "DRINKING WATER" as per IS : 10500-1991 from govt approved laboratory including transportaion of warer complete all as specified and directed
(a) Bacterioligical requirements: Testing of coliform Organisms/100ml.
(b) Chemical requirements : Testing of colour hazen unit max odour taste turbidity NTU max, pH value, total hardness (as CaCo3) mg/lmax, iron (as FE) mg/l max.
(c) Desorable Charactreristics : Testing of dissolved solids mg/l max, Calcium (as CA mg/l mnax, magnesium (as Mg) mg/l max, Copper (as Cu)mg/l max, Manganese (as Mn) mg/l max, Shulphate (as SO4) mg/l, max, nitrate (as NO3) Mg/l phenolic compound mg/l max, mercury (as Mg) mg/l max, Cadmium (as Cd) Mg/l max, Selenium (as Se) mg/l max, Arsenic (as As) mg/l max, Cyanide (as CN) mg/l max, Lead (as Pb) mg/l max, Zinc (as An) mg/l max, Chromium (as Cr+( mg/l max, Mineral Oil, mg/l max Note :- Testing of raw water is mandetory at every quarter failing which a recovary of Rs 1000.00 per test shall be recovered from the contractor.
10
-
-
M&L in repairs rotational modulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 1000 Ltr size all as specidied and directed by Engr-in-Charge.
10
-
-
S&F in repairs circular cover for water storage tank, any capacity made out of 1 mm thick GI sheet PVC water storage tank fix with suitable screws (indoor to protact monkey menance) design and size as per sample kept in GE office or as approved by Engr-in-Charge complete all as specified.
10
-
-
Reapair to header 300 mm using mild steel, plain black sheet, 4 mm thick in wall cladding, cut to size, fixed to headers at various locations of water supply installations with 40 mm lap join by welding seams, including bending or turning up, mitred angles and fixing of sluice valve etc as required complete all as specified and directed by Engr-in charge at site.
2
-
-
Reapair to header 250 mm using mild steel, plain black sheet, 4 mm thick in wall cladding, cut to size, fixed to headers at various locations of water supply installations with 40 mm lap join by welding seams, including bending or turning up, mitred angles and fixing of sluice valve etc as required complete all as specified and directed by Engr-in charge at site.
2
-
-
S&F in repair MS Pipe ERW Steel including specials, nominal 300 mm dia as per IS 3589 (1981) thickness 5.4 mm.
18
-
-
All as per item No. 29 above but 250 mm dia
20
-
-
Material and labour for clearing of surrounding area of pump house by surface excavation upto 10 cm average depth including removing shrubs, grass, implant, small bushes, branches of tree and other unwanted materials/stones etc and spray of herbicide chemical on grass at all around area of pump house including levelling complete all as specified and directed. Note : (i) The cost of hebricide chemical for grass & petrol and machinery for cutting of grass included in quoted rate.
15
-
-
S&F in repair sluice valve, Class PN-1, 200 mm dia both end flanged with high tensile SS spindle with lock nut (gutka), ISI marked complete with jointing materials such as rubber packing, nuts, bolts & washers complete all as specified & directed.
2
-
-
All as per item No-32 above but 150 mm dia.
2
-
-
All as per item No-32 above but 100 mm dia.
2
-
-
All as per item No-32 above but 80 mm dia.
2
-
-
S&F MCCB 4 Pole, 415 V, fixed type type, 25 to 100 Amps with breaking capacity 16 KA
4
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
4
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
4
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
4
-
-
S&F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
4
-
-
Taking up or down for 100mm bore old steel tubing and connections complete all as specified & directed.
250
-
-
All as per item No 41 here in before but 80 mm bore
350
-
-
Supply, laying and jointing for the 100mm bore in trenches/on floor/wall, galvanized steel tubing medium grade including ISI marked GI fittings, including cutting to reducing length, screwing and connecting with existing line including fix existing connection with required size of Tee or MS clamp with rubber bush complete all as specified and directed
250
-
-
All as per item No 43 here in before but 80 mm bore
350
-
-
Excavation in trenches in soft/loose soil, n. exc. 1.5 M wide and n.exc 1.5 M in depth, to required level and gradient for laying of pipe etc and getting out complete all as specified and directed.
162
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed.
16.2
-
-
Removing excavated materials (soft/loose soil) to a distance n.exc. 50 M and depositing where directed at a level n.exc. 1.5 M above the starting point complete all as specified and directed.
145.8
-
-
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.
200
-
-
Supply and fixing 100 watt ,230 V AC outdoor type ,5700K LED security Flood light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed.
40
-
-
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed.
220
-
-
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
190
-
-
All as per item No-50 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.
Note for item No. 50 and 51:- (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
30
-
-
S&F switch piano flush type single pole , 5/6 Amps one way, 230 volts, all as directed .
220
-
-
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed.
220
-
-
M&L for calcium hypochlorite having 65%-70% available chlorine packed in 45 Kgs plastic durms for water treatment chemical of make approved by the E-in-Cs Br. Note :- Test report is reqd with item
730
-
-
Supply, laying testing, connecting XLPE armoured, LT 1100V grade (heavy duty) copper conductor cable,of following sizes confirming to IS7098(Part-I) 1988, laid in existing RCC covered duct/Sub way/along wall/MS bracket. Note : The Cables shall be fixed to LT panel with suitable size brass/stain less steel cable glants, copper lugs and rate deemed to be included in rate quoted for respective cable
-
-
-
a) 3 Core 95 Sqmm
30
-
-
b) 3 Core 70 Sqmm
30
-
-
b) 3 Core 50 Sqmm
95
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%