If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 6,41,200
Costs
EMD
₹ 12,824Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Spl Repair To Conf Hall At Bde Hq, Zone -11
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664610_1Bid Award Id
ViewTender No
8936 E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
210
-
-
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment of voids in masonry, alongwith wall below concrete or masonry apron using chemical emulsion @ 1.00 litre per holes, soil under existing floors using emulsion @ 1.00 litre per hole, including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) and match the existing floors complete all as specified and as directed.
100
-
-
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment of soil under existing floor using chemical emulsion 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) and match the existing floors using emulsion @1 litre por hole complete all as specified and as directed.
50
-
-
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre / hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with cement mortar (1:3) & painted with white or coloured paint complete all as specified and as directed
15
-
-
Dismantling floor, hearth or wall tilling including cement mortar bedding, and rubbish off premises etc complete all as specified and directed.
46
-
-
M & L for Vitrified Ceramic tiles Dark Shade 10mm thick (Square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), complete all as specified and directed.
41
-
-
All as the item above but as in skirting but tile laid over 10mm thick CM (1:4) plaster complete all as specified.
5
-
-
Taking down chowkats or frames n.exc. 1.5 sqm each with shutters (W/o taking off shutters from the frame) and removal to store complete all as specified and as directed
4
-
-
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),
Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water
etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x
18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected
accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each ®
3
-
-
S&F in position 4.8 to 5mm thick frosted glass on one side quality and glazing with glazing clips including necessary rubber packing to aluminium framen n. exc 0.5 sqm in each pane all as specified and as directed.
3
-
-
M&L for Framed work such as grills, gratings, etc with ends of bars
shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors,ladders; framed baluster,railings and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed
34
-
-
Cutting openings, through brick walls built in cement mortar for door, windowand other openings or enlarging existing openings.converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m ®
0.25
-
-
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8
and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
5
-
-
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing ®
1.45
-
-
S&F butt hinges medium weight cold rolled mild steel ISI marked size 100 mm size complete all as specified and directed.
3
-
-
S & F 200mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed
2
-
-
S & F 150mm long Extruded brass Handles fabricated type polished
2
-
-
M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
1
-
-
M&L for 15mm thick plaster in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed.
9
-
-
M & L preparation new plastered surfaces of walls and providing two coat of cement base paint complete all as specified and directed.
4.5
-
-
Supply and Installation of Spring Polyester Roller Blinds spring component easy for useing, once touch up the second pull stop, can stay any positions you want.Spring strength can be adjusted by a key with hanging rails, mounting bracket , spring , weight including all accessories and required hard ware in different size of window indifferent rooms complete all as specified and directed.Make and sample approved by AGE (I).
5
-
-
Excavation in trenches in soft/disintegrated rock/hard dense soil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 meter in depth and getting out complete all as specified and directed.
20
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm each layers complete all as specified and directed.
15
-
-
Removal of excavated material & surplus spoil n. exc 50 m to a distance and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and directed.
5
-
-
M&L for spreading M-sand cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thickness up to 18 cm complete all as specified and directed.
Note: - Only punned thickness will be considered for payment.
5
-
-
Supply and laying Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed.
298
-
-
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
55
-
-
Taking down carefully complete light fittings removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
5
-
-
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete.
Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
7
-
-
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc complete.
20
-
-
M/L for point wiring concealed type with 1.5 sq mm FRLS PVC insulated single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia alongwith chase/ chisel cutting, PVC conduit and making good to the disturbed surface and match the existing colour all as specified and directed : Wire: Make -Mescab/Polycab/KEI/Havells/Finolex
PVC conduit: Make -Polycab/Precision/Plaza/Kalinga
Note:- (i) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
(ii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quated.
-
-
-
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
25
-
-
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
8
-
-
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
10
-
-
All as per item NO 5 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core FRLS PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
12
-
-
S&F modular switch single pole one way 6/10 Amp 240 volt.
MAKE:- Havells(Oro)/Anchor(Roma classic)/Philips
43
-
-
S&F modular switch single pole one way 16/20 Amp 240 volt.
MAKE:- Havells(Oro)/Anchor(Penta)/Gold Medal
12
-
-
S&F for modular socket 5 Pin 6/10 Amp with shuttered, suitable for 2 module 240 volt.
MAKE:-Havells(Oro)/Anchor(Roma classic)/Philips
18
-
-
S&F for modular socket 5 Pin 6/16 Amp flush type, with shuttered, suitable for 2 module.
Make: Havells(Oro)/Anchor(Roma classic)/Philips
12
-
-
S&F for modular Outer and Inner plate for 2 module MAKE:-Havells(Oro)/Anchor(Roma classic)/Philips
5
-
-
S&F for modular Outer and Inner plate for 3 module MAKE:-Havells(Oro)/Anchor(Roma classic)/Philips
5
-
-
S&F for modular Outer and Inner plate for 6 module MAKE:-Havells(Oro)/Anchor(Roma classic)/Philips
8
-
-
S&F modular type fan regulator electronic step type, suitable for 2 modules 100 watt, 240 volt.
MAKE:-Havells(Reo)/Anchor(Roma classic)/Philips
3
-
-
M&L for sub main concealed wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly.
Wire: Make -Mescab/Polycab/KEI/Havells/Finolex
PVC conduit: Make -Polycab/Precision/Plaza
Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit.
(ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
(iii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quated.
20
-
-
M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm, 04 Core complete.
50
-
-
S&F vertical sheet metal enclosure double door for MCCB DB Triple pole and neutral 4 way, (4+12) with 200 Amps rated bus bar 440 volts earth dolly IP-43, IK09, and making good to the disturbed surface complete.
Make:- Legrand/Hager/Schneider/IndoAsian/Siemens/Havells.
1
-
-
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with one single pole MCB of 20 to 32 Amp 240 volt.
Make:- Legrand/Hager/Schneider/IndoAsian/Siemens.
4
-
-
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts double door (Metallic) type.
Make:- Legrand/Hager/Schneider/IndoAsian/Siemens.
2
-
-
S&F MCB SP 6 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
12
-
-
S&F MCB SPN 40 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
2
-
-
S&F MCCB 4 pole 63 Amp, 440 volt 'C' series, 16 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
1
-
-
Supply and fixing LED Recessed Panel 15 W Square ceiling light complete all as specified and as directed by Engineer-in-Charge. Make Havells/Surya/Crompton/Philips
5
-
-
M&L for PVC casing capping of size 100 x 50 mm complete
16
-
-
Note :-
Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
-
-
-