Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date23 Dec 2024
Closing Date28 Jan 2025
Tender Amount₹ 5,42,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹44,500/MT*
Uttar Pradesh

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of Scotter Shed with Permanent specification complete all as specified and shown on drawings.

1

-

-

... More
SCHEDULE A PART II (Internal Water Supply) for details refer Sch A in pdf folder

1

424461

-

... More
SCHEDULE A PART III 'A' (Internal Electric Supply) for details refer Sch A in pdf folder

1

175151

-

... More
SCHEDULE A PART III 'B' (Internal Electric Supply)

-

-

-

... More
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - Note: Rates is included with modular plate and frame.

-

-

-

... More
(a) One light point point /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch.

565

-

-

... More
(b) One three pin 5 Amp socket on same board with other switches.

76

-

-

... More
(c) One three pin 5 Amp socket on independent board.

152

-

-

... More
(d) All as per above but for two way wiring.

10

-

-

... More
All as per item No-8 here-in-before above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.

152

-

-

... More
All as per item No-8 here-in-before above but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm.

19

-

-

... More
Supply and fix modular switch 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.

793

-

-

... More
Supply & fix modular switch 05 / 06 Amps single pole, two way 240 volts complete all as specified & directed.

20

-

-

... More
Supply and fix modular socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.

228

-

-

... More
Supply & fixing of modular socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed .

152

-

-

... More
Supply and fix in modular switch 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.

152

-

-

... More
Supply and fixing modular bell push flush type , 5 amps , 240 volts complete all as specified and directed.

19

-

-

... More
Supply and fix ding dong bell,AC , 230 volts ,Single pole complete all as specified and directed.

19

-

-

... More
Supply & fix lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed.

57

-

-

... More
Supply & fix modular setp type Fan step regulator, 120W - 2 module complete all as specified and directed.

76

-

-

... More
Supply and fix modular blanking plate on the existing modular plate & switch box excluding modular plate as required complete all as directed.

150

-

-

... More
Supply and fix ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified

337

-

-

... More
Supply and fixing of MCB TPN, 100 Amps, 415 Volt,10 KA 'C' curve complete all as specified and directed.

5

-

-

... More
S&F DB TPN, 415 volt with 250 amps rated copper bus bar for double door 4 way IP-54, IK-09 suitable for one MCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).

5

-

-

... More
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).

19

-

-

... More
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 04 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).

5

-

-

... More
S&F MCB SP, 40 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .

30

-

-

... More
S&F MCB SP, 5 to 32 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .

162

-

-

... More
S&F MCB SPN, 40 to 63 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .

19

-

-

... More
S&F MCB SPN, 32 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .

5

-

-

... More
Supply & fix LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders, including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.

211

-

-

... More
Supply & fix LED light fitting high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders, including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed.

19

-

-

... More
Supply & fix LED lamp 12 watt, 220 volt AC decorative type connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.

57

-

-

... More
Supply and fix exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers

19

-

-

... More
Supply and fix exhaust Plastic body AC single phase 230 V of size 250 mm sweep with blades and frame and louvers

38

-

-

... More
Supply and fix BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with squirrel cage induction motor complete all as specified and directed.

76

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion

15

-

-

... More
Supply and fixing of earth continuity conductor or main earthing lead wire 4.0 mm , GI wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles/wall or any other indicated situation for loop of earthing etc. complete all as directed.

100

-

-

... More
S&F GI pipe light grade 15 mm dia laid in trenches/ fixed in walls complete all as specified and directed

100

-

-

... More
Supply, installation, testing and commissioning of Water Heater Storage Type five star rating, electric suitable for single phase ,50HZ, AC supply, stainless steel inner assembly, 2 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 25 ltrs capacity.

19

-

-

... More
Supply, fix, connecting and testing building LED security light fitting 35 W with pressure die cast aluminium housing, heat resistant toughened glass, IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.

50

-

-

... More
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as directed

19

-

-

... More
SCHEDULE A PART IV 'A'(Site Clearance and Earthwork) for details refer pdf folder

1

1605214

-

... More
SCHEDULE A PART IV B (Site Clearance and Earthwork)

-

-

-

... More
Supply selected/approved earth brought from outside the site and filling the same in plinths,back of retaining walls,foundations and trenches and spreading in landscaping and other location as directed by project manager and shall be done in layers,not exc 20cm in depth and consolidating each deposited layer by mechanical means,ramming and watering as specifications including transportation,cost of soil,royalty,loading,uploading,carriage to dumping spot and all incidentals at all depths and levels,for all leads and lifts complete(Net consolidated area fill volume will be computed from the initial and final levels.Volumslopes,embankments etc.will be computed applying appropriate formula,as per MES specification.)

100

-

-

... More
SCHEDULE A PART V 'A' (Road, Path and Hardatanding) for details refer pdf folder

1

14932159

-

... More
SCHEDULE A PART V B (Road, Path and Hardatanding)

-

-

-

... More
S&F cat eye solar reflective type of metal body alloy of size 100mmx100mmx20mm with PAMA striplens reflector of model No DA 972.0 fixed with and incl MS stud of suitable size as per manufacturers instructions all as specified and directed.

112

-

-

... More
S&F metal tubular dealineator made our of ABS round body fitted with 2 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600mm height duly powder coated and thermo plastic elasomer 3 bands of green, red and yellow reflector radium tape of 25mm wide strips with anti theft steel net for reflector protection including embeeding in PCC 1:2:4 (150x150x300) type B-1 complete all as specified and directed.

35

-

-

... More
M&L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc and the like on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufactures instruction complete all as specified and directed.

560

-

-

... More
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder

1

371681

-

... More
SCHEDULE A PART VI B (Sewage Disposal)

-

-

-

... More
Construction of RCC septic tank fo 100 User excavation in any type of soil foundation in PCC 1:2:4 RCC wall and slab covers including RCC precast manhole covers having 6m plate embeded all around / fabric reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified and directed.

1

-

-

... More
M&L for soakage well excavation in ordinary soil foundation in PCC 1:3:6 walls of honeycomb masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick massonary in CM. RCC cover shelves in M-25/SFRC cover interconnecting pipe of RCC/ DWC complete filled with brick bats of size 2.40x6.00m complete all as specified and directed.

1

-

-

... More
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder

1

1081952

-

... More
SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder

1

2769111

-

... More
SCHEDULE A PART IX A (Hot Water Supply) for details refer pdf folder

1

74755

-

... More
SCHEDULE A PART IX B (Hot Water Supply)

-

-

-

... More
Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element up to 2.0 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, with PVC connection 45Cm long both end SS nut threaded type with cromium coated and PVC washer complete all as directed at site.

19

-

-

... More
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder

1

355119

-

... More
SCHEDULE A PART X B (External Water Supply)

-

-

-

... More
Material and labour for construction of brick massonery valve pit of size 1 Mtr X 1 Mrt X 1 Mrt (Internal dimensions ) including all excavation and earth work in any type of soil and disposal of soil to a distance of not exciting 50mtr and depositing all as directed including 10mm plastering internally in CM 1.4, PCC type 1:2:4 ratio and 100mm thick at bottom and top of valve pit, including and MS Sheet cover of 3.0mm thick with angle iron frame 35X35X5mm and 40X40X5mm at bottom for minting and MS sheet cover inlet handle inlcuding two coats of synthetic enamel paint over a coal of red oxide primer on steel surface complete all as specified

2

-

-

... More
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder

1

1019083

-

... More
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)

-

-

-

... More
Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) 1000mmx800mmx400mm size, outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 600 Amps rating installed on porcelain insulators having statndard size 80x10 mm. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indiated in Hindi and English with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directedincluding connections of all out going/in coming existing cables of size 25/35/50/95/120/ 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, . Contd...

1

-

-

... More
All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old skelton type panel with control switches complete all as specified and as directed Engr-in-Charge , The scope of work includes the following:- Note: Rate of items No. 61 to 68 are to be included in this item

-

-

-

... More
Incoming MCCB 4 Pole , 415V, 250 Amps, with rupturing capcity 35 KA Nos -1

-

-

-

... More
Outgoing MCCB TPN, 415V, 63 Amps,50 Hz with rupturing capcity 25 KA Nos-6

-

-

-

... More
Busbar aluminium 600 Amp with air insulated for TPN - One Set

-

-

-

... More
Digital Voltmeter 0- 500 V - 01 No, Digital Ampere Meter 0- 200 Amp - 01 No

-

-

-

... More
RYB Phase indicating lamp LED type - 03 Nos

-

-

-

... More
Panel wiring with 2.5 sqmm copper cable PVC single core

-

-

-

... More
Fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure.

-

-

-

... More
PCC of platform with foundation 1:2:4 Job

-

-

-

... More
Supply and Install steel tubular swaged poles type 410 SP-31 (9 Mtr long) complete with CI base plate and singlr swan neck and Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m heightcomplete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supplying fixing in repair connecting and testing of energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium with toughened glass cover housing, 70 watts LED to achieve electrical safety class 1, CRI70 colour temperature 5000k to 6000k with LED working life time 50000 burning hours with integrated constant current electronic driver, nominal volatge 240V, AC,50 Hz, operating voltage range 120-280V, suitable for ambient environmental condition of station, TDH10%,, Pf 0.95, lumens 80 lm/W, Ingress protection not less than IP65, driver and luminaire shall comply not less than LM-79 or IS 16106 of 2012 including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with Two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers or providing reducers and GI pipe of size suitable for exixting top fixed bracket duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed. Make Polycab/Bajaj/Phillips

15

-

-

... More
M&L for Weather proof flat twin core aluminium cable conductor of size 2.5 Sqmm for connection of Securiry light to OH or Pole Box all acomplete as specified and directed.

150

-

-

... More
M& L for pole box fabricated out of PVC 1.8 mm thick MS Sheet having for out door installation having 3 nos busbar 50 Amp Aluminium bus bar conductor mounted on insulators, one no 20 x 3 mm aluminium bus bar with 2 clamps of aluminium strip for earthing of the armoured of cable complete. making connection of cables etc nuts bolts etc size of box 250 x 150 x 100 mm front openable hinged cover suitable for mounting on steel tubular poles using clamps nut bolt etc , PVC adopters and PVC hose pipe upto cable trench for incoming and outgoing cable , MCB SP 6 Amp , factory made duly painted powder coating process complete all as specified and directed.

15

-

-

... More
Supply and errecting steel tubular pole swaged type 11.0 Meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc. Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m heightcomplete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply, installation, testing and commissioning outdoor type platform mounted step down transformer of capacity 160 KVA, 11 KV/415 Volts (at NO load), AC 3 Phase, 50 HZ, core type double copper wound, oil immersed, naturally cooled, oil natural-Air natural (ON/AN) with external cooling tubes, delta connection on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with Neutral brought out on secondary side (LV side) and having tapings at (-) 2.5% and 5% on HV side to be changed by means of hand operated OFF load tap changer gear and transformer should conforming to level-2 of IS-1180 : 2014. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree celsius. Transformer shall comprise of the following item No. 79 to 88

1

-

-

... More
(a) One cable box LT side (secondary side) consisting of four Nos porcelain bushing with copper rods complete with nut & washers with one No cable gland suitable for reception/ taking out of 240 Sqmm 3 1/2 core LT 1100 Volts grade XLPE insulated and PVC sheathed heavy duty armoured cable including gland, joint & jointing material complete all as specified.

-

-

-

... More
(b) HT side (primary side) consisting of three Nos porcelain bushing with copper rods complete with nut and washers with cable gland HT busing suitable for outdoor mounting transformer, 11000 Volts grade XLPE insulated heavy duty armoured cables including gland joint and jointing material complete

-

-

-

... More
(c) Oil conservator with filter type drain valve and oil level guage complete

-

-

-

... More
(d) De-hydrating breather with first fill of dehydrating agent (silica gel) complete

-

-

-

... More
(e) Explosive vent & thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, air release valve plug and four Nos solid cast steel detachable rollers

-

-

-

... More
(f) One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device

-

-

-

... More
(g) Four earthing terminals on tank cover to facilitate fixing of 32mm x 6mm galvanised iron earth strip for earthing of neutral & body

-

-

-

... More
(h) Rating plate and terminal marking plate

-

-

-

... More
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthig for neutral.

-

-

-

... More
(k) First filling of new and unused transformer oil IS-335 marked filtered and tested upto 40 KV dielectric strength at 2.5mm air gap between testing electrodes.

-

-

-

... More
Supply and Install APFC Panel with MPPH capacitor and MCCB as incommer Cap:100 KVAR with 5 steps (50+25+15+5+5) capacity

1

-

-

... More
M&L earthing of pole GOD and other equipments complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe medium grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC cover 40 mm thick in plain cement concrete 1:2:4 type B1 duly reinforced with 8mm dia TMT bars @ 150mm c/c with 10mm dia MS round bar as in lifting handles, mild steel angle iron frame for pit cover made out of 40x40x5mm thick duly painted with two coats of ssynthetic enamel paint over a coat of priner , excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 03 of SSR Part I

7

-

-

... More
All as per item no 95 above but using galvanized strip 32x6mm as earthing lead.

3

-

-

... More
M & L for boaring in any type of soil under road 1.5 Mtr below the top surface of road by conventional method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.

35

-

-

... More
M&L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable) completed all as specified and directed. Note:- Punned thickness only will be considered for payment.

124

-

-

... More
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm, ISI marked complete all as specified and directed.

3611

-

-

... More
M&L burnt clay fly ash Modular bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.

7.56

-

-

... More
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 100Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 complete all as specified and directed.

10

-

-

... More
SCHEDULE A PART XII (Arboriculture)

-

-

-

... More
Supply and plantation of grass selection No 1 bermuda by digging root method all with following activites :- (a) Ploughing of whole site in soft/ordinary soil upto variable depth and removing all unwanted material such as stones, weeds, tree roots etc. (b) Dressing and levelling to a required gradient and slope after loosening the soil. (c) Mixing of manure and fertilizers evenly manually in the ratio specified as under :- (i) Old cow dung or okhia sludge @ 4 cubic ft per 10 sqm (ii) Neem @ 1kg per 10 sqm (iii) DAP (18-46-0) @ 0.15Kg per 10 sqm (iv) BHC 10 % or lindane dust @ 0.15 Kg per sqm (d) Fine dressing of top soil after mixing the namure and fertilizer to required slope (e) watering the area and fine dressing of soil after one week till soil gets water upto reqd depth. (f) Plantation of grass @ 10 Cm c/c both ways by Root digging method complete all as specified and directed.

250

-

-

... More
Supply and plantation of green sapling of plants and shurbs of Rose 2' to 3' high incl preparation of compost of size 300mm x 300mm x 300mm by excavation, applying ATT, planting the trees / plants refilling the pit with compost manure sand and sweet earth in the ratio 1:1:4 breaking the clots, ramming and flooding with water and filling with more compost earth if necessary, fine dressing incl removal of rubbish / unserviceable material. ATT shall be in form of 200 gms Neem cake mixed with every cum of compost followedby dursban 20 EC applied at 2ml/litre in the first watering of 20 ltr per pit. As per user requirement :

180

-

-

... More
-ditto- as above but Sunflower

25

-

-

... More
Supply and plantation of green sapling of plant and shurbs of Ashoka 2' to 4' high incl preparation of compost of size 300mm x 300mm x 300mm by excavation, applying ATT, planting the trees / plants refilling the pit with compost manure sand and sweet earth in the ratio 1:1:4 breaking the clots, ramming and flooding with water and filling with more compost earth if necessary, fine dressing incl removal of rubbish / unserviceable material. ATT shall be in form of 200 gms Neem cake mixed with every cum of compost followedby dursban 20 EC applied at 2ml/litre in the first watering of 20 ltr per pit all as specified and directed. As per user requirement

90

-

-

... More
Supply & Fixing Fountain having dia 3.00 mtr, 1.50m depth including Excavation, RCC Water Tank, RCC Pardi as retaining wall, Water Proofing to Water tank , fixing glazed ceramic tiles in water tank , providing Pump 7.5 Hp and Necessary elcrification and necessary plumbing work complete all as specified .

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.