Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date9 Nov 2024
Closing Soon23 Nov 2024
Tender Amount₹ 67,92,900
Costs
EMD
₹ 1,35,858Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679158_2Tender No
87431/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply , installation, testing and comissioning of fire alarm sounders/sirens electronic type single stage continuos normal operation for atlest 50 minute with sound level 65 dB to 120 dB measured at 1.5 m with sound output variation of +5dB 500 m range .
9
-
-
S&F of 2Cx1.5 sqmm FRLS PVC with mylertape insulated copper conductor armoured cable including PVC conduit size 25mm with all fittings and accessories complete all as specified and as directed.
5760
-
-
Supply and fixing factory made epoxy powder coated distribution board SPN 04 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
9
-
-
Supply and fixing MCB single pole & neutral 240 volt 'C' curve 10 KA 40 to 63 Amps complete all as specified and directed .
9
-
-
Supply and fixing MCB single pole 240 volt 'C' curve 10 KA 32 Amps complete all as specified and directed .
9
-
-
M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
405
-
-
Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed for following size :-
-
-
-
16 Sqmm 4 core
450
-
-
25 Sqmm 3.5 core
675
-
-
35 Sqmm 3.5 core
820
-
-
Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
498.89
-
-
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
340.6
-
-
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
158.3
-
-
Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected
149.67
-
-
Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
15.96
-
-
Supply & Fixing in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
60
-
-
Excavation in soft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out incl old U/s cable cover of ant type , taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces complete all as specified and directed.
482
-
-
Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed.
462
-
-
Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed.
25
-
-
Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
10
-
-
Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :-(Earth work shall be measured and paid separately).
-
-
-
150mm bore dia
250
-
-
100mm bore dia
780
-
-
Laying only in trenches CI pipe with spigot and socketed ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :-
-
-
-
150mm bore dia
50
-
-
100mm bore dia
80
-
-
Supply & laying in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-
-
-
-
150 mm bore dia
200
-
-
100 mm bore dia
700
-
-
M&L for cutting of the CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes complete all as specified and directed:-
-
-
-
150 mm bore
20
-
-
100 mm bore
40
-
-
M&L for rubber gasket joint suitable for DI pipe and fittings with size of nuts, washer & bolts etc complete all as specified and directed for the following sizes :-
-
-
-
150 mm bore
85
-
-
100 mm bore
180
-
-
M&L for upto 150 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot,caps and plugs complete all as specified and directed.
350
-
-
Taking up or down steel water tubing and connections including clearing the pipes free from scaling for reusing the same complete all as directed for the following sizes :- Note :-Excavation will be measured and paid separately
-
-
-
50 mm dia bore
90
-
-
40mm dia bore
110
-
-
25 mm dia bore
300
-
-
20 mm dia bore
200
-
-
15 mm dia bore
110
-
-
Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc all as specified and directed
-
-
-
50 mm dia bore
30
-
-
40 mm dia bore
50
-
-
25 mm dia bore
100
-
-
20 mm dia bore
100
-
-
15 mm dia bore
50
-
-
Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for the following sizes:- Make: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately.
-
-
-
50 mm dia bore
60
-
-
40 mm dia bore
60
-
-
25 mm dia bore
200
-
-
20 mm dia bore
100
-
-
15 mm dia bore
60
-
-
S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves.Make : Zoloto/Seico/Jindal/Upadhaya/Venus
-
-
-
50 mm bore
20
-
-
40 mm bore
20
-
-
25 mm bore
35
-
-
20 mm bore
32
-
-
15 mm bore
30
-
-
S&F 15 mm dia PVC bib tap with crutch handle screwed down screwed for iron pipe including taking out unserviceable tape of 15mm dia complete all as specified and directed.
50
-
-
Supply, fixing, jointing and testing in repair of cast iron sluice valve class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed for following bore of CI pipe line :-
-
-
-
150 mm dia bore
5
-
-
100 mm dia bore
6
-
-
Dismantling old broken / damaged valve pit chamber and construct valve pit chamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
8
-
-
All as per item No 18 above but size of valve chamber is 900 x 900 x 900 mm (internal) and all as specified and directed.
5
-
-
S&F in replacement of service outlet having two half clamp made out of MS strip of 6 mm thick with nut bolt and rubber sealing ring suitable to fit for PVC pipe, the out let shall be threaded 40 mm size to suit the inlet of hydraunt complete all as specified and directed.
42
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%