Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Jun 2023
Closing Date19 Jul 2023
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_605554_1Bid Award Id
ViewTender No
8656/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 10 Sqmm 2 core with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately under respective item.
800
-
-
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 10 Sqmm 4 core with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately under respective item.
900
-
-
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade of size 16 Sqmm 4 core with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as specified and directed. Note: - Excavation, earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately under respective item.
700
-
-
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for laying of electric cable complete in any type of soil complete all as specified and directed. Note :- For the digging of soil, JCB machine will not be allow at site, it will be done by labour only and contractor will be responsible to repair the existing cable , pcc plinth etc without extra cost which will be damaged during execution of wk.
598
-
-
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed.
290
-
-
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
308
-
-
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
26560
-
-
M & L for sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured for payment.
269
-
-
M&L for boring under road horizontely of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil complete all as specified and directed.
100
-
-
M&L in replacement for 40 mm bore GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor / as garden post including 2 Nos mild steel FI clamps 35x3 mm size to support pipe with pole complete all as specified and directed.
80
-
-
S&F in replacement pole box junction three phase of size 297x 250 x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint, and in built locking arrangement, out door type , fix to pole with suitable MS clamp comprising of aluminium busbar 16 Amp 04 Nos fix on epoxy insulated support and including MCB 6 Amp 10 KA 240 volt complete all as specified and directed.
310
-
-
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings any type for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacement by department) complete all as specified and directed.
424
-
-
M& L for repairing of unserviceable search light fittings fixed on watch tower of any type/make by replacing burn out/worn-out/ weak MH lamp 1000 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
6
-
-
M& L for repairing of unserviceable street light fittings fixed on pole of any type/make by replacing burn out/worn-out/ weak HPSV lamp 250 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
75
-
-
M& L for repairing of unserviceable street light fittings fixed on pole of any type/make by replacing burn out/worn-out/ weak HPSV lamp 150 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
100
-
-
M& L for repairing of unserviceable street lightT-5 fittings fixed on pole of any type/make by replacing burn out/worn-out/ weak T 5 tube rod 24 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
110
-
-
M&L for repair of Bldg security light by replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/ saving retrofit LED tube of nominal wattage-18 watt , having lumen out put 2100 lumen or above, colour temperature 6500 kelvin, size & length- G13/ T8 / 4 feet operating voltage 140 to 280 volt AC THD -15 % , with integral /inbuilt driver and having short circuit and surge protection including minor addition/ alteration in existing circuit as required complete all as specified and directed.
345
-
-
M& L for repairing of unserviceable bldg security light fittings by replacement of worn out 36 watt FPL with linear LED PLL lamp with extruded plasting body and PC diffuser complete with inbuilt driver of high efficacy of system wattage 18 watt length 419 mm lumen out put 1800 lm or above, colour temp 6500 K suitable for existing 2G 11 lamp holders including minor alteration complete all as specified and directed.
235
-
-
M& L for repairing of unserviceable street light fittings fixed on pole of any type/make by replacing burn out/worn-out/ weak copper ballast 250 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
110
-
-
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak copper ballast 150 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
90
-
-
M& L for repairing of unserviceable search light fittings fixed on watch tower of any type/make by replacing burn out/worn-out/ weak copper ballast 1000 watt and re-fixing the fitting in position after repair and testing complete all as specified and directed.
8
-
-
M& L for repairing of unserviceable street lightT-5 fittings (fixed on pole) of any type/make by replacing burn out/ worn-out/ weak Electronic ballast 2x24 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
90
-
-
M& L for repairing of unserviceable street light(70-400watt ) fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak Electronic ignitor and re- fixing the fitting in position after repair and testing complete.
200
-
-
M& L for repairing of unserviceable search light(1000 watt ) fittings (fixed on watch tower) of any type/make by replacing burn out/worn-out/ weak Electronic ignitor and re- fixing the fitting in position after repair and testing complete.
6
-
-
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak bi-pin holder for T-5 fittng and re- fixing the fitting in position after repair and testing complete.
365
-
-
M& L for repairing of unserviceable street light (fixed on pole) of any type/make by replacing burn out/worn-out/ weak holder for HPSV/MH fitting (70-400 watt) and re-fixing the fitting in position after repair and testing complete.
55
-
-
M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 9/11 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
311
-
-
M& L for repairing of unserviceable Gate light of any type/make by replacing burn out/worn-out/ weak LED lamp 25 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
105
-
-
M&L for repairing of unserviceable LED street light any make /model of 70-90 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 277 Volt 50/60 Hz AC supply complete all as specified and directed.
340
-
-
M&L for repairing of unserviceable LED street/flood light any make /model of 100-150 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 277 Volt 50/60 Hz AC supply complete all as specified and directed.
145
-
-
Make of item No. 23 to 40 : Contractor will mark a identity (i.e CA No . or Firm Name) ,using permanent paint marker pen on each component which will be replace under repair of street light and he will be liable to change his new replaced items without any extra cost which become unserviceable due to any reason, during execution period of CA and further upto defect liability period. it will be contractor responsibility to take the location of unvs street/garden/post top/ search light fittings by MES rep at 9 AM at Power house in every working day.
-
-
-
S&F in replacement contactor 3 phase 40 amps for street light timer in existing panel/ location and connection incl necessary alteration in panel/ door as required for proper fixing & connection complete all as specified and directed.
45
-
-
Taking down of single phase electric operated search light motor of capacity 2 HP from watch tower & dismanteling, rewinding with existing guage size copper wire and as existing Nos of turns of coils for maitaining existing capacity of the motor and varnishing ,drying including refixing & testing for proper rotation of search light fitting at watch tower complete all as specified and directed.
3
-
-
Taking down of single phase electric operated search light motor of capacity 2 HP from High Mast & dismanteling, rewinding with existing guage size copper wire and as existing Nos of turns of coils for maitaining existing capacity of the motor and varnishing ,drying incl re fixing & testing for proper rotation of search light fitting at watch tower complete all as specified and directed.
8
-
-
S&F in replacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm two core complete all as specified and directed.
1000
-
-
S&F rigid PVC conduite 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed.
1100
-
-
Supply, fixing, connecting, & testing LED streetlight fitting of 90 Watt high pressure die cast aluminium housing, with minimum 125 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector including PVC conduit 20 mm & PVC copper cable 2.5 Sqmm 3 core from junction pole box to fitting complete all as specified and directed.
90
-
-
Supply, fixing, connecting, & testing LED street light fitting of 70 Watt high pressure die cast aluminium housing, with minimum 120 lumen / watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector including PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed.
90
-
-
Supply, fixing, connecting, & testing LED Flood light fitting of 100 Watt high pressure die cast aluminium housing, with minimum 110 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector including PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3 core from junction pole box to fitting complete all as specified and directed.
42
-
-
Supply, fixing, connecting, & testing LED Flood light fitting of 170 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector including PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed.
30
-
-
Supply, fixing, connecting, & testing LED streetlight fitting of 35 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3 core from junction pole box to fitting complete all as specified and directed.
115
-
-
S&F in replacement new generation, post top, energy saving, environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium landscape IP65 luminaire with high power COB LED of 10/12 watt as light source including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed. Make Philips, Cat Part No. BGP30035757 PSUPCINS1 or equivalent make as specified in PS.
30
-
-
S&F in replacement new generation, post top, energy saving, environment friendly, long life aesthetically designed with good symmetrical light distribution, spum aluminium landscape luminaire with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed. Make-Crompton Cat Part No. LPTP-40-CDL or equivalent make as specfied in PS.
30
-
-
S&F in replacement new generation,post top, energy saving,environment friendly, long life aesthetically designed with good symmetrical light distribution, spum aluminium landscape luminaire with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed. Make-Havells Cat Part No. CORALMINIPT15WLED757PSYMTOPC or equivalent make as specified in PS.
25
-
-
S&F in replacement new generation,post top, energy saving,environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed. Make-Philips Cat Part No.BCP400 LED09 D CW PSU GR S1(1.0 M) or equivalent make as specified in P.S.
25
-
-
M&L for painting with green colour synthetic enamel paint including preparation of surfaces to perimeter light stand 2.5 mtr long 40 mm GI pipe complete all as directed.
190
-
-
M&L for replacement of Lamp holder of post top latern fitting complete all as specified & directed.
80
-
-
S&F in replacement pole box three phase of size 297x 250 x 130 mm made out of 2 mm MS sheet factory made with in built locking arrangement, out door type, fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fix on epoxy insulated pole and MCB 6 Amp 10 KA 240 volt complete all as specified and directed.
55
-
-
S&F in replacement bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
85
-
-
S&F MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using PCC & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
45
-
-
Supply & fixing of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is 30 lux and for switching OFF 10 lux.The nature switch along with suitable power contactors , incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure make of rust proof , electric shock proof and FR grade SMC junction box confirming to IP 65/66 complete all as specified for the following: -
-
-
-
Suitable of three phase load of 5 kw with contactors (single phase 3 Nos), incoming & Outgoing MCB SP (6 Nos),rating of 20-25 Amp & circuit wiring of min 10 sqmm complete all as specified and directed. Make -Swadeep Cat No. swadeep -02EC 5kw3P or equivalent make in Siemens /Indoasian
15
-
-
Suitable of single phase load of 2 kw with contactor (single phase 1 No), incoming & Outgoing MCB SP (6 Nos), rating of 20-25 Amp & circuit wiring of min 10 Sqmm. Make -Swadeep/siemens /Indoasian or as approved.
15
-
-
Note for item No 61.01 & 61.02 (i) Nut bolts, clamp for fixing on pole/wall are to be included in quoted rate.
(ii) The sensor must have warranty of minimum 2 years.
(iii) Test certificate and warranty certificate must be provided by supplier.
(iv) Cost of marking description on the box is included in the quoted rate.
-
-
-
M& L for repairing of unserviceable street light fittings fixed on pole of any type/make by replacing burn out/worn-out/ weak MH lamp 250 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
40
-
-
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak MH lamp 150 watt and re- fixing the fitting in position after repair and testing complete all as specified and directed.
35
-
-
S&F MCB DB SPN 2 way double door type , comprising of one MCB SPN 16 Amp 'B' series 415 volt including fixing of DB on pole/ wall with suitable arrangement for the garden light incl making wall surface smooth as existing using plastering and white wash complete all as specified and directed.
23
-
-
S&F in replacement contactor 3 phase 25 amps for street light timer in existing panel/ location and connection incl necessary alteration in panel/ door as required for proper fixing &connection complete all as specified and directed.
12
-
-
M&L for repairing of unserviceable LED street light any make /model of 20-35 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt 50/60 Hz AC supply complete all as specified and directed.
180
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements