Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jun 2024
Closing Date14 Sep 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SERVICING AND MAINTENANCE OF CLIMATE CONTROL EQUIPMENTS AND OTHER COOLING APPLIANCES AT OLD CANTT AND FORT CANTT UNDER GE (EAST) PRAYAGRAJ.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing in repair following spare parts of window type AC/split type AC 1.5/2 Ton (dismantled against item no 1 and 3 here in above) :-

-

-

-

... More
Running capacitor 36/45/50 + 6mfd ± 5%, 440 Volt AC.

25

-

-

... More
Starting capacitor 120-150 mfd

5

-

-

... More
Starting capacitor 100-120 mfd

25

-

-

... More
Relay for window AC. Capacity 1.5 T/2 T

30

-

-

... More
Thermostate

25

-

-

... More
Propeller fan suitable for window/split type AC

20

-

-

... More
Blower Motor 1/5 or 1/6 HP suitable for Air conditioner window type upto 1.5 ton capacity as per existing model complete all as directed and specified.

10

-

-

... More
Blower Motor 1/5 or 1/6 HP suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.

10

-

-

... More
Blower Motor 1/5 or 1/4 HP suitable for Air conditioner split type of capacity 1.5 ton as per existing model complete as directed and specified.

5

-

-

... More
Blower Motor 1/5 or 1/6 HP suitable for Air conditioner split type of capacity 2 ton as per existing model complete as directed and specified.

5

-

-

... More
Blower Motor for indoor unit suitable for Air conditioner split type of capacity upto 2 ton as per existing model complete as directed and specified.

10

-

-

... More
PLC unit for split type air conditioner as same make and capacity.

20

-

-

... More
Split AC contactor single phase 230V of suitable capacity for Split AC 1.5 Ton/2 Ton including coil.

20

-

-

... More
Sealed compressor unit of capacity of 1.5 Ton AC window/split type incl initial fiiling of suitable refrigerant gas of adequate quantity complete all as specified & directed.

10

-

-

... More
Sealed compressor unit of capacity of 2 Ton AC window/split type incl initial fiiling of suitable refrigerant gas of adequate quantity complete all as specified & directed.

10

-

-

... More
Stand suitable for installation of outdoor unit of split AC 1.5/2 ton incl nut bolts and fastner complete all as specified and directed.

5

-

-

... More
Repair to water cooler any capacity any make by dismantling the parts etc cleaning and servicing of serviceable parts, replacement unservicebale parts and re- assembling the serviceable spare parts etc and testing for smooth functioning and re-installation at site or deposit in MES store yard complete all as directed by Engineer-in-Charge. Note:- (i) The item shall be operated only if the appliances are not repairable at site. (ii) Spair parts incl refrigerant gas shall be measured and paid seperatly under respective items of Sch A. (iii) Cost of cleaning , washing, oiling, greasing, etc. and minor parts viz. screw, washer, insulated tape, clips, nut & bolts washers etc. deemed to be included in the quoted rates. (iv) Cost of re-installation at same location or other loaction and testing shall deemed to be included in the quoted rates. (v) Cost of to and fro transportation to workshop or MES store yard deemed to be included in above rates

25

-

-

... More
Supply and fixing in repair following spare parts of Water cooler any capacity (dismantled against item no 1 and 5 here in above) :-

-

-

-

... More
New sealed compressor unit of water cooler 80-120 Litre cooling capacity and make for suitable existing water cooler.

5

-

-

... More
New sealed compressor unit of water cooler 40-80 Litre cooling capacity and make for suitable existing water cooler.

5

-

-

... More
Running capacitor 25/36 mfd ±5% 440 Volt AC supply.

10

-

-

... More
Running capacitor 20/10 mfd ± 5% 440 Volt AC supply.

10

-

-

... More
Starting capacitor 60/70 mfd.

10

-

-

... More
Starting capacitor 40/50 mfd.

10

-

-

... More
Starting capacitor 80 mfd.

10

-

-

... More
Start Relay for water cooler any capacity.

15

-

-

... More
Over load protector same make and capacity.

15

-

-

... More
Thermostate

15

-

-

... More
Condensor motor 1/35 HP single phase 230V.

10

-

-

... More
Condensor motor 1/24 HP single phase 230V.

10

-

-

... More
Condensing coil

10

-

-

... More
Plastic drain hose pipe (not exe 1.0 Rm)

10

-

-

... More
Push cock/lift cock brass with chromium plated.

20

-

-

... More
Capillary Tube (not exceeding 0.60m).

20

-

-

... More
Float Valve 1/2 " including assembly brass made

20

-

-

... More
Chromium plated drain tray with PVC pipe of water cooler complete all as specified and directed.

5

-

-

... More
Repair to refrigerator/deep freezer any capacity any make by dismantling the parts etc cleaning and servicing of serviceable parts, replacement unservicebale parts and re- assembling the serviceable spare parts etc and testing for smooth functioning and re-installation at site or deposit in MES store yard complete all as directed by Engineer-in-Charge. Note:- (i) The item shall be operated only if the appliances are not repairable at site. (ii) Spair parts incl refrigerant gas shall be measured and paid seperatly under respective items of Sch A. (iii) Cost of cleaning , washing, oiling, greasing, etc. and minor parts viz. screw, washer, insulated tape, clips, nut & bolts washers etc. deemed to be included in the quoted rates. (iv) Cost of re-installation at same location or other loaction and testing shall deemed to be included in the quoted rates. (v) Cost of to and fro transportation to workshop or MES store yard deemed to be included in above rates

25

-

-

... More
Supply and fixing in repair following spare parts for refrigerators of any capacity (dismantled against item no 1 and 7 here in above) :-

-

-

-

... More
Sealed compressor unit of refrigerator 160 to 253 Litre cooling capacity complete all as specified and directed.

5

-

-

... More
Sealed compressor unit of refrigerator 280 to 340 Litre cooling capacity complete all as specified and directed.

5

-

-

15

-

-

... More
Over load protector

15

-

-

... More
Thermostate

10

-

-

... More
Cooling coil

10

-

-

... More
Condensing coil

5

-

-

... More
Bulb Holder

10

-

-

... More
Bulb pin type /screw type 15 Watt

10

-

-

... More
Door switch

15

-

-

... More
Chilled tray

20

-

-

... More
Vegitable tray

20

-

-

... More
Bottle supporter

20

-

-

... More
Capillary Tubeing (not exceeding 0.40m)

15

-

-

... More
Topping and filling of following refrigerant gas against item No- 1 to 8

-

-

-

... More
Supply only refrigerant gas (R-22) in sealed container with cylinder and valve duly tested complete all as specified and directed.

20

-

-

... More
Supply only refrigerant gas (R-32) in sealed container with cylinder and valve duly tested complete all as specified and directed.

25

-

-

... More
Supply only refrigerant gas (R-410) in sealed container with cylinder and valve duly tested complete all as specified and directed.

10

-

-

... More
Supply only refrigerant gas (R-134a) in sealed container with cylinder and valve duly tested complete all as specified and directed.

15

-

-

... More
M&L for Detection and rectification of leakage of storage tank of water cooler by brazing, soldering/ welding as required at site or at work shop and unserveciable spare parts such as Nipple adaptor, Push cock, float valve & Bush, nut, bolt, washer, rubber/plasting packing are included in unit quoted rates not any claim on this account will be replaced for smooth functioning & testing for leak proof complete all as specified and directed.

10

-

-

... More
M&L for Spray painting of water cooler after preparation of old surface of water cooler with one coat of synthetic enamel paint as approved complete all as specified and directed.

10

-

-

... More
Dismantling voltage stabilizer of capacity 3/4/5 KVA incl strip opening, checking, locating fault and repair the same incl replacement of unserviceable items and reinstalling the same at same or other location complete all as specified and directed Note: (i) Spare parts shall be measured and paid separately under item No. 12.01 to 12.09 as supply and fix in repair . (ii) Replacement of nut & bolts washers deemed to be included in unit quoted rate. (iii) Minor repair work deemed to be included in unit quoted rate.

25

-

-

... More
Volt meter (0-300 volts).

20

-

-

... More
Control relay.

20

-

-

... More
IC controlled circuit for 5 KVA/4 KVA.

15

-

-

... More
IC controlled circuit for 3 KVA.

10

-

-

... More
Control transformer rating input 170 to 250 Volt and output 230 Volt.

12

-

-

... More
Low/high voltage cut off and TDR system.

10

-

-

... More
Main transformer for 5 KVA/4 KVA.

10

-

-

... More
Main transformer 3 KVA

10

-

-

... More
Main transformer 1 KVA

10

-

-

... More
Repairing of the Desert Cooler of any capacity and make, dismantling of complete items and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, opening of Fan motor from their brackets, and fixing of Fan Motor and Pump, replacement of internal wiring and connection and testing after repair complete. Note:- (i) Overhauling/Oiling of fan motor, Vertical pump replacement of Nuts, bolts washers/elbow, if required shall be deemed to be included in unit quoted rate. (ii) Unserviceable spare parts to be replaced shall be measured and paid separately as supply & fix in repair under respective item. (iii) Minor repair of chassis of brazing/welding work deemed to be included in unit rate. (iv) Provide PVC Sheathed cable of 23/.0076 up to 1.5 meter in replacement if required will be deemed included in the unit rate.

300

-

-

... More
Supply and fixing in repair following spare parts suitable for Desert Coolers existing make or existing capacity:-

-

-

-

... More
New wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.

300

-

-

... More
Fan motor of 1/6 HP to 1/10 HP 230V AC electric of same capacity and same make

70

-

-

... More
Blade for kit Fan.

50

-

-

... More
MS Bracket for kit fan motor

20

-

-

... More
Submersible Pump set suitable for desert coolers of fractional H.P.

300

-

-

... More
Rotory Switch

50

-

-

... More
Piano type Switch, 5 Amp 230 Volt AC

50

-

-

... More
Front Directional Grill

25

-

-

... More
PVC pipe 10 mm dia flexible

100

-

-

... More
Side panel made out of PGI Sheet 1 mm thick of size not less than 0.5m width and 0.7m height (set of three) complete.

15

-

-

... More
Storage tank made out of PGI Sheet 1 mm thick of size not less than 0.7 m X 0.7M and height 0.2m complete.

10

-

-

... More
M & L for dismantling the parts of desert cooler for body painting after scraping out of old paint of complete body (internally & externally) of Desert Coolers making good, smooth surface and applying spray painting with one coat of synthetic enamel paint for external surfaces/ internal surface, refixing of all parts, testing complete all as specified and directed. Note:- Painting has to done with proper spray paint gun and other T&P, rates to which deemed to be included in above rates

20

-

-

... More
Taking down from site, transporting to workshop and over hauling, servicing and repair of ceiling fan/exhaust fan/wall fan/air circulator fan/pedestal fan of any sweep/make i.e. opening of fan and cleaning ball bearing, filling grease/oil and changing of nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling including refixing at site complete all as specified and directed. Notes:- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately under appropriate item of Sch ‘A’ (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush deemend to be included in above rates (v) Painting of ceiling fan if required shall be measured and paid for separately under appropriate item of Sch ‘A’

2000

-

-

... More
Supply and fixing in repair following spare parts suitable for fans of existing make or existing capacity:-

-

-

-

... More
Metal bush bearing for ceiling fan/ exhaust fan/ cabinet/ pedestal fan of any make/ sweep complete

195

-

-

... More
Capacitor 3.15/ 4 mfd + 5% 440V AC.

450

-

-

... More
Capacitor 2.5 mfd rating complete all as specified and directed.

1280

-

-

... More
PVC sheathed white colour three core copper flexible cable of size 23/.0076 complete.

200

-

-

... More
Ball bearing size No. 6201 for ceiling/exhaust fan

850

-

-

... More
Ball bearing size No. 6202 for ceiling/exhaust fan

525

-

-

... More
Ball bearing size No. 6203 for ceiling/exhaust fan

240

-

-

... More
Rotor shaft for Ceiling/exhaust fan of any make/sweep complete all as specified and directed.

125

-

-

... More
Canopy for ceiling fan suitable for any sweep / make as required complete all as specified and directed.

200

-

-

... More
Nut bolt of size 8mm dia 100mm length complete all as specified and directed.

200

-

-

... More
Rubber reel for ceiling fans complete all as specified and directed.

420

-

-

... More
CLIP for down rod complete with rubber reel and nut bolts for ceiling fans complete all as specified and directed.

415

-

-

... More
Down rod of size 1 ft/2ft for ceiling fans complete all as specified and directed.

300

-

-

... More
Down rod of size 3ft for ceiling fans complete all as specified and directed.

20

-

-

... More
Fan blade made out of aluminium, painted with white colour and suitable for 1200 mm sweep ceiling fan complete all as specified and directed.

50

-

-

... More
Fan blade made out of aluminium, painted with white colour and suitable for 1400 mm sweep ceiling fan complete all as specified and directed.

40

-

-

... More
Fan hook made out of 40x6 mm flat iron suitable for hanging of ceiling with proper size nut bolt and washers to be fixed in pipe of 40 mm bore dia fixed in repair complete all as specified and directed.

30

-

-

... More
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc incl re-marking MES No. complete all as specified and directed.

450

-

-

... More
S&F in repair Stepped socket type electronic fan regulator flush type AC 230 volt 120 W suitable for any type of ceiling fan fixed in repair complete all as specified and directed.

120

-

-

... More
S&F mettalic louvers for opening of exhaust fan of size 300/380 mm complete all as specified and directed.

100

-

-

... More
S&F mettalic louvers for opening of exhaust fan of size 450 mm complete all as specified and directed.

25

-

-

... More
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-

-

-

-

... More
Ceiling Fan of 1200 mm sweep size

1800

-

-

... More
Ceiling Fan of 1400 mm sweep size

850

-

-

... More
Exhaust Fan of 450 mm sweep size

40

-

-

... More
Exhaust Fan of 380 mm sweep size

75

-

-

... More
Exhaust Fan of 300 mm sweep size

315

-

-

... More
Exhaust Fan of 225/230 mm sweep size

210

-

-

... More
Cabin/padestal Fan of 400 mm sweep size

40

-

-

... More
M&L in repair for GI tubing 40mm bore medium grade in required length and grouting in wall for hanging of ceiling fan all as directed by Engr- in -Charge ande making good disturbed surface of wall to match existing surface complete al as specified and directed.

10

-

-

... More
Taking down carefully existing geyser of any capacity after disconnecting all electrical and water supply connection and removing the geyser & bring to E&M store yard for opening the geyser, cleaning all the serviceable parts throughly including descaling the geyser, replacing the defective/ wornout parts/ material reassembling the geyser after repair testing for proper functioning, including re-fixing the same in position and reconnecting the geyser with electric and water supply line and testing as directed, complete all as specified and directed. NOTE:- (a) Spare parts required for replacement shall be measured and paid separately .

550

-

-

... More
M&L for Repair to leakage of inner tank including assembly 25/50 litre capacity geyser by brazing or soldering, including cutting of nut, bolt, washer etc, as required with gas welding cutter and provinding new nut, bolt, washer etc including testing of leakage of tanks, complete all as specified and directed.

100

-

-

... More
S&F in repair Inner tank made of MS 1.6 mm thick suitable for 25 litre capacity geyser, complete all as specified and directed.

30

-

-

... More
S&F in repair Inner tank made of MS 1.6 mm thick suitable for 50 litre capacity geyser, complete all as specified and directed.

10

-

-

... More
S&F in repair Apperture plate assembly suitable for 25 litre capacity geyser, complete all as specified and directed.

30

-

-

... More
S&F in repair Apperture plate assembly suitable for 50 litre capacity geyser, complete all as specified and directed.

15

-

-

... More
S&F in repair Outer body of geyser made of 1.25 mm thick MS sheet suitable for 25 litre capacity geyser, complete all as specified and directed.

40

-

-

... More
S&F in repair Outer body of geyser made of 1.25 mm thick MS sheet suitable for 50 litre capacity geyser, complete all as specified and directed.

20

-

-

... More
S&F in repair Bottom cover for geyser in two pieces made of MS sheet in required/ existing size and shape suitable for 25 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing, complete all as specified and directed.

50

-

-

... More
S&F in repair Bottom cover for geyser in two pieces made of MS sheet in required/ existing size and shape suitable for 50 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing, complete all as specified and directed.

25

-

-

... More
S&F in repair Heating element threaded/ screwed/ triangular or cup style type 1500 Watt ISI marked of suitable make without taking down Geyser, complete all as specified and directed.

950

-

-

... More
S&F in repair Heating element threaded/ screwed/ triangular or cup style type 2000 Watt ISI marked of suitable make without taking down Geyser, complete all as specified and directed.

400

-

-

... More
S&F in repair Thermostat suitable for 25 or 50 litre capacity of geyser, range 20 to 80 degree ISI marked, without taking down geyser, complete all as specified and directed.

500

-

-

... More
S&F in repair geyser assembly suitable for geyser of capacity 25 ltrs complete all as specified and directed.

100

-

-

... More
S&F in repair geyser assembly suitable for geyser of capacity 50 ltrs complete all as specified and directed.

10

-

-

... More
S&F in repair PVC connection cotton braided heavy duty with brass union/ coupling of length 450 mm with rubber washer suitable for 15 mm dia pipe for hot or cold water connection, without taking down geyser, complete all as specified and directed.

400

-

-

... More
S&F in repair Indicator lamp assembly with bulb suitable for geysers round or square type of approved make and quality as approved, without taking down geyser, complete all as specified and directed.

300

-

-

... More
S&F in repair Bib taps, cast copper alloy, chromium plated, fancy type, capstain head handle, screwed down, screwedat one end, 15mm bore, complete all as specified and directed.

10

-

-

... More
S&F in repair Stop valves, cast copper alloy, screwed down, high pressure, with capstan head handle, screwed both ends for iron pipe or for unions and fixed, chromium plated, 15 mm bore complete all as specified and directed.

10

-

-

... More
M&L for Flexible copper wire 3 core of size 40/0.0076/2.5 sqmm, 1100 volt and making electric connection in geyser, complete all as specified and directed.

200

-

-

... More
M&L One coat painting of Geyser at site by spray gun painting of 25 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number, complete all as specified and directed.

100

-

-

... More
M&L One coat painting of Geyser at site by spray gun painting of 50 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number, complete all as specified and directed.

30

-

-

... More
S&F in repair Zebra fastener of size 12x100 mm, complete all as specified and directed.

400

-

-

... More
S&F in repair Spring loaded air release safety valve made of brass as per existing shape and size of approved make, complete all as specified and directed.

100

-

-

... More
Taking down solar water heating system panel of 200 litres capacity, any make and type carefully for cleaning dust, cleaning the water collector tubes including descaling the existing hot water storage tank of any capacity and refixing after repair complete all as specified and directed. Note:- Spare shall be measured &paid seperately

2

-

-

... More
S&F in repair Gun metal globe or gate valve, 15mm bore, complete all as specified and directed.

5

-

-

... More
S&F in repair Non return valve 15mm dia made of bronze ISI marked heavy duty, complete all as specified and directed.

5

-

-

... More
M&L for Painting of complete system after scrapping and cleaning old painted surfaces with synthetic enamel paint including writing MES No complete all as specified and directed

2

-

-

... More
S&F in repair Solar water heater storage tank of capacity 200 litre with MS stand of strandard size, inlet outlet, over flow water pipe connections complete with nuts and bolts of suitable size and PCC work in 1:2:4 ratio as required at site including taking down old unserviceable, fixed in replacement complete all as specified and directed.

1

-

-

... More
M&L for Taking down carefully sub main wiring of any numbers of wire on wooden batten or surface conduit or concealed conduits / casing caping any type, complete all as specified & directed.

750

-

-

... More
M&L for Sub main wiring with two single core PVC insulated unsheathed, grade cable 4.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 4 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.

250

-

-

... More
M&L for Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 6 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.

200

-

-

... More
M&L for Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 6 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS and including provision of cutting chases for sinking for boxes inlcuding making good to walls disturbed surfaces and applying finishes to match existing surfaces and including laying in and including provision of 20mm wide PVC suface casing and caping and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC casing and caping and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.

150

-

-

... More
M&L for Sub main wiring with two single core PVC insulated unsheathed, grade cable 10.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 10 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 10 sq.mm copper conductor, one run of 10 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.

150

-

-

... More
M&L for Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 15mm dia GI pipe 'medium' grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.

10

-

-

... More
M&L in repair for Wall mounted LT panel board of size as per manufacturer's design, powder coated paint, dust & vermin proof, factory fabricated with 2 mm thick CRCA sheet with front openable doors and locking arrangement comprising of following:-- Note : All connection from bus bar will be copper Insulated strip of suitable size & Insulated support. [a] Three phase and neutral Insulated bus bar copper LT 440 Volt 200 Amp [b] Digital voltmeter 96x96 mm size (0-500Volt) range with selector switch -- 01 No [c] Digital Ampmeter 96x96 mm size (0-300 A) with selector switch and CTs -- 01 No [d] Indicator lamp LED type RYB --- 01 (Set of three) [e] MCCB 100 Amp Four Pole breaking capacity 25 KA fixed magnetic and thermal release -- 01 No [f] MCB 32 Amp SPN, breaking capacity 10 KA - 04 Nos [g] MCB 20 Amp SPN breaking capacity 10 KA as outgoing -- 01 No [h] Fixing and connection of existing Energymeter -- 04 Nos [j] Name slip holder on each compartment for identification of Accn -- 04 Nos [k] Earthing Terminal -- 02 Nos

5

-

-

... More
M&L in repair for Wall mounted LT panel board of size as per manufacturer's design, powder coated paint, dust & vermin proof, factory fabricated with 2 mm thick CRCA sheet with front openable doors and locking arrangement comprising of following:-- Note : All connection from bus bar will be copper Insulated strip of suitable size & Insulated support. [a] Three phase and neutral Insulated bus bar copper LT 440 Volt 200 Amp [b] Digital voltmeter 96x96 mm size (0-500Volt) range with selector switch -- 01 No [c] Digital Ampmeter 96x96 mm size (0-300 A) with selector switch and CTs -- 01 No [d] Indicator lamp LED type RYB --- 01 (Set of three) [e] MCCB 160 Amp Four Pole breaking capacity 25 KA fixed magnetic and thermal release -- 01 No [f] MCB 32 Amp SPN, breaking capacity 10 KA - 06 Nos [g] MCB 20 Amp SPN breaking capacity 10 KA as outgoing -- 01 No [h] Fixing and connection of existing Energymeter -- 04 Nos [j] Name slip holder on each compartment for identification of Accn -- 06 Nos [k] Earthing Terminal -- 02 Nos

5

-

-

... More
S&F in repair Plug top of 15/16 Amps, 230 Volt capacity, three pin, complete all as specified and directed.

30

-

-

... More
S&F in repair two pin and earth plug and socket set of current rating 20 Amps in existing box complete all as spicified and directed.

50

-

-

... More
S&F in repair MCB 6 to 32 Amps Single pole 'C' series, 10 KA complete all as specified & directed.

50

-

-

... More
S&F in repair MCB 32 Amps Double pole 'C' series, 10 KA complete all as specified & directed

25

-

-

... More
S&F in repair sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket of current rating 20 Amps complete with fixing one single pole MCB. 'C' series of current rating 20/25 Amps incl taking out existing DB complete all as specified and directed.

25

-

-

... More
S&F in repair single phase & neutral MCB distribution box of 8 way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, din rail, earth bar confirming to IS 13032 & 86234 incl replacing existing worn out Kit Kat DB/MCB DB/switch fuse unit complete all as specified and directed.

10

-

-

... More
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.

20

-

-

... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed.

10

-

-

... More
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.

10

-

-

... More
Supply and fix wall fan made of sturdy Engineering plastic complete voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 400mm complete all as specified and directed.

10

-

-

... More
Supply and fixing swimming pool light 100% water proof resin filled and high brightness wall hanging, 9" dia, warm white light 12 volt, 30 watt with minimum IP-65 protection and required size of PVC insulated copper conductor cable complete all as directed as specified.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.