Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Date19 Dec 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685001_1Tender No
84357/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condensor unit, gas piping system and AHU complete cycle system of capacity 1x22 TR, and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Note:- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item herein after.
2
-
-
... More
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condensor unit, gas piping system and AHU complete cycle system of capacity 1x23 TR, and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Note:- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item herein after.
3
-
-
... More
M&L for disconnecting, taking out/ down, dismantling, loading/unloading, transporting form site to trade workshop and back after repair of electric motor, including strip opening & taking out the old worn out/unserviceable winding wire and rewinding the electric motor/mono-block with superior quality copper winding wire of suitable size including insulating material (PVC insulation sleeve, tape, film paper, varnish, cotton) required and re-fixing in position and testing complete all as specified & directed of following capacities :-
-
-
-
... More
(a) 3 HP
5
-
-
... More
(b) 5 HP
4
-
-
... More
(c) 12.5 HP
3
-
-
... More
(d) 20 HP
3
-
-
... More
(e) 30 HP
3
-
-
... More
M&L for taking out the mono-block pump 5 HP shaft, remetalling, welding, turning and fixing new bush and sleeve and re-fixing in position complete all as specified and directed.
5
-
-
... More
S&F in replacement ball bearing double coller type complete all as specified and directed for following capacities of electric motor/mono block motor:-
-
-
-
... More
(a) 3 HP
10
-
-
... More
(b) 5 HP
5
-
-
... More
(c) 12.5 HP
4
-
-
... More
(d) 20 HP
3
-
-
... More
(e) 30 HP
3
-
-
... More
S&F in replacement refrigerant gas pressure gauge of suitable size with adopter flair work and brazing work of the following range complete all as specified and directed.
-
-
-
... More
(a) HP - 30 to 300 Lbs
12
-
-
... More
(b) LP - 30 to 150 Lbs
10
-
-
... More
(c) OP - 30 to 150 Lbs
10
-
-
... More
S&F in replacement dial type water pressure gauge 4'' dia of working pressure 5 Kg/Sqcm complete with adopter complete all as specified and directed
10
-
-
... More
S&F in replacement HP/LP cut off switch including control valve & brass flare nuts and making electric connections complete for any capacity of AC plant complete all as specified and directed.
10
-
-
... More
S&F in replacement OP cut off switch including control valve & brass flare nuts and making electric connections complete for any capacity of AC plant complete all as specified and directed.
10
-
-
... More
Taking out oil filter assembly by opening up all the bolts of side cover and replacing the unserviceable oil filter by new one, re-assembling the same and fixing in to its original position by tightening the all bolts & making the system leak proof including providing the side cover gasket for the following sizes :-
-
-
-
... More
(a) SMC - 3 x65
6
-
-
... More
(b) SMC - 4 x65
3
-
-
... More
(c) SMC - 8 x 65
3
-
-
... More
Repair of LT electric control panel board, cleaning inside with blower, servicing tightening all electrical connections/ contacts points, replacing defective locking clips thimble and making it serviceable with inter locking wiring including replacement of the defective parts and refixing back in its existing position complete all as specified and directed.
Note : Defective parts will be measured and paid separately as supply only.
5
-
-
... More
Supply only the following parts of panel board to be fixed under respective items here in above or before complete all as specified and directed:-
-
-
-
... More
(a) Electronic timers type ET-100, 110 V to 240 V, 50 Hz, 3 Sec to 10 Sec.
6
-
-
... More
(b) Electronic timers type ET-100, 110 V to 240 V, 50 Hz, 9 Sec to 30 Sec.
5
-
-
... More
(c) Contactor ML 1.5
6
-
-
... More
(d) Contactor ML 2
5
-
-
... More
(e) Contactor ML 3
4
-
-
... More
(f) Power contactor ML 4
4
-
-
... More
(g) Biametalic over load relay ML type 9 to 14 Amps
8
-
-
... More
(h) Biametalic over load relay ML type 20 to 32 Amps
4
-
-
... More
(j) Biametalic over load relay ML type 28 to 48 Amps
4
-
-
... More
(k) Volt meter 0-500V make : AE (Digital type)
8
-
-
... More
(l) Ampere meter CT type of ratio 5/100 Amp any range Make : AE (Digital type)
10
-
-
... More
(m) PVC insulated stranded single core copper conductor cable 1100 Volts grade of size 10 Sqmm
50
-
-
... More
(n) PVC insulated stranded single core copper conductor cable 1100 Volts grade of size 16 Sqmm
30
-
-
... More
(o) connector 4 pole, 20 to 40 Amp, 240 volts complete all as specified and directed.
8
-
-
... More
(p) MCB TP 63 Amp,50 Hz,, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
6
-
-
... More
(q) MCB TP, 40 Amp,50 Hz, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
4
-
-
... More
S&F in replacement strip heater 3 KW single phase complete all as specified & directed.
60
-
-
... More
Dismantling air filter section any size of air handling unit and M&L for overhauling/servicing of AHU by cleaning the AHU complete, cooling coil with coil shine, by spraying the dust removal chemical on the fins of coil and let the chemical remains on the fins for 04 hours then clean the chemical with fresh water till the chemical flushes out entirely by pressure of water & wash completly including stoppage of air leakage by using gasket clothing and PGI sheet with nut , bolts and cleaning air handling room with bleaching powder solution/chemical/acid & cleaning of air filter wire mesh/5 micron filter with above solution complete all as specified and directed.
7
-
-
... More
S&F in replacement of fan belts of following size complete all as specified and directed :-
-
-
-
... More
(a) B-72 Compressor Motor 20HP
10
-
-
... More
(b) B-84 Compressor Motor 12.5 HP
12
-
-
... More
(c) B-96 Compressor Motor 30 HP
8
-
-
... More
S&F in replacement to old existing safety release valve comprising for renewal of Teflon sheet and adjustment of valve for AC plant of any capacity complete all as specified and directed.
6
-
-
... More
S & F in replacement three phase motor connector plate suitable for 3 HP to 5 HP complete all as specified and directed.
8
-
-
... More
S & F in replacement three phase motor connector plate suitable for 12.5 HP to 30 HP complete all as specified and directed.
6
-
-
... More
Supply and fix in replacement water spray header, suitable for 2x9.5 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
4
-
-
... More
Supply and fix in replacement water spray header, suitable for 2x14 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement water spray header, suitable for 2x20 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement water spray header, suitable for 2x23 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
2
-
-
... More
Supply and fix in replacement PVC fills of size 300x300x150 mm complete all as specified and directed.
180
-
-
... More
S & F in replacement solenoid coil (for any size of solenoid valve or loader- unloader) and making necessary electric connection complete all as specified and directed
6
-
-
... More
S&F in replacement thermostatic expansion valve flange type of size suitable for 3x9.5 TR (R-22) AC plant as per and making necessary connection complete all as specified and directed.
6
-
-
... More
S&F in replacement thermostatic expansion valve flange type of size suitable for 3x14 TR (R-22) AC plant and making necessary connection complete all as specified and directed.
4
-
-
... More
S&F in replacement thermostatic expansion valve flange type of size suitable for 3x23 TR (R-22) AC plant as per and making necessary connection complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement PVC water protection cover /jali for protecdtion from birds, leaf etc to cooling tower tank complete all as specified and directed.
76
-
-
... More
M& L for installing, commissioning & testing of the filter section consists of pre-filter should be made of 14 gauge stainless steel to remove 99.90% of dust, pollen, mold, bacteria and any airborne particles with a size 0.1 micrometer at 85 liters per minute, 90% efficiency complete all as specified and directed. The pre-filter having the following sizes :
-
-
-
... More
(a) 60 x 60 cm
12
-
-
... More
(b) 54 x 60 cm
10
-
-
... More
S&F in replacement GI steel tubing 'medium grade' on wall/floor including cutting, threading of required size suitable for connection to condenser, mono block pump, cooling tower, gate valve including all GI fittings complete all as specified and directed for the following bores:-
(a) 80mm dia bore
10
-
-
... More
(b) 40 mm dia bore
8
-
-
... More
(c) 25mm dia bore
20
-
-
... More
S&F in replacement gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified & directed. (a) 80 mm dia
5
-
-
... More
(b) 40 mm dia
4
-
-
... More
(c) 25 mm dia
5
-
-
... More
S&F in replacement cast iron non return valve of 80 mm bore with flanged end, ISI marked complete with jointing materials complete all as specified and directed.
2
-
-
... More
Supply & charging refrigerant gas M-22 in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all as specified and directed.
960
-
-
... More
Supply & filling non freezing compressor oil in sealed standard sized containers complete all as specified and directed.
180
-
-
... More
M &L for spray painting of 9.5 TR to 23 TR compressor -03 Nos, 12.5 HP to 30 HP electric motor- 03 Nos, 3 HP to 7.5 HP Monoblock pump - 02 Nos and GI Tubing 100 mm dia -15 RM, Cooling tower - 01 No outer body of complete AC Plant by applying one coat of synthetic enamel grey/green paint over the existing paint including cleaning and preparation of surface complete all as specified & directed.
3
-
-
... More
De-scaling the entire water circulation system of AC Plant including condenser but excluding mono block pump set from existing AC plants by circulating de scaling solution with the help of de -scaling pump circulating acid independently in each tube by gravity cleaning the condenser tubing with brush including renewal of worn out gasket, nuts and bolts complete all as specified and directed of following size:-
-
-
-
... More
(a) 3 x 23 TR AC plant capacity
3
-
-
... More
(b) 3 x 20 TR AC plant capacity
3
-
-
... More
(c) 3 x 14 TR AC plant capacity
3
-
-
... More
(c) 3 x 9.5TR AC plant capacity
6
-
-
... More
M&L for openig side cover of compressor by descrewing nuts, bolts etc and replacing shaft seals assy, complete with neoprene 'O' ring and corban seal & refixing side cover with replacement of packing gaskets and leak testing and rectifying if found complete all as specified and directed of following capacity:-
-
-
-
... More
(a) Suitable for SMC 3-65
4
-
-
... More
(b) Suitable for SMC 4-65
2
-
-
... More
(c) Suitable for SMC 8-65
2
-
-
... More
Supply and fixed in replacement, air break (power) contactor 3 TF30 0-32 Amp complete all as specified and directed.
5
-
-
... More
Supply and fixed in replacement, air break (power) contactor 3 TF30 0-10 Amp complete all as specified and directed.
5
-
-
... More
Supply and fixed in replacement, HRC catridge fuse 20 Amp, (IS9224) complete all as specified and directed.
15
-
-
... More
Supply and fixed in replacement, HRC catridge fuse 63 Amp, AC complete all as specified and directed.
12
-
-
... More
S&F in replacement, 25 mm dia gun metal stop valve with iron wheel head screwed both ends for iron pipe complete all as specified & directed.
6
-
-
... More
S&F in replacement, 20 mm dia stop valves, cast copper alloy, screwed down , high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions complete all as specified and directed.
6
-
-
... More
M& L for replacement of templrature gauge suitable for fixing on existing water line of AC plant of range 0 to 60 degree centigrate complete all as per existing sample including filling of oil in mounting pocket complete all as specified and directed.
14
-
-
... More
S&F in replacement water flow control switch suitable for fixing on chilled water type central AC plant condensor/chilller pipe line,suitable for max pressure 10 bar, model HFS-25, Make Synergy or eqivalant as approved by GE complete all as specified and directed.
4
-
-
... More
Supply and fixing in repairs MCCB 4 Pole, 415 V, Adjustable type, 100 to 63 Amps with breaking capacity 16 KA.complete all as specified and directed.
1
-
-
... More
Supply and fix in repairs three Phase Auto Sequence Corrector of 200 Amps, 440volt Suitable for correcting the RYB phase sequence, whenever the sequence is changed or reversed complete all as specified and directed.
1
-
-
... More
Technician Charges for Checking of Package type AC for detecting any kind of fault in AC with attending the fault immediately at any time round the clock and Carry out certain repair required as per site requirement.
Note: (a) Parts required shall be measured and paid separately as "supply only" under respective item here-in-before. (b) Rate quoted shall be inclusive of detecting any kind of fault in DG set.
8
-
-