Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Jun 2024
Closing DateCancelled
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_658414_1Bid Award Id
ViewTender No
GE/W/LKO/42 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for provn of roof treatment with polymeric water proofing membrane all as given below:-
(a) Preparation of old AC/Manglore tiles roof surfaces including cleaning of roof surface by washing and rubbing etc. and removing the retrieved material to a distance not exceeding 500m where directed.
(b) Applying a coat of Bitumen, blown type, 85/25 grade on prepared surface of AC/Mangalore pattern roof .
(c) Applying and laying 2 mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10cm and 15cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3.
(d) M&L for applying two coats of aluminium paint on membrane @ 0.10 Kg/Sqm (each coat) complete all as specified and as directed.
200
-
-
... More
M&L 10mm thick rendering in CM 1:4 using 100% coarse sand over roof slab, finished surface even and smooth without using extra cement and mixed with 3% integral water proofing compound complete all as specified and as directed..
Note: (i) WPC shall measured and paid seperately.. (ii) Wherever screed bed shall be provided, PCC padding shall not be provided.
2500
-
-
... More
M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate and mixed with 3% integral water proofing compound as in padding over roof slab, finished surface even and smooth without using extra cement complete all as specified and as directed.
Note: (i) WPC shall measured and paid seperately.
50
-
-
... More
Supply only Integral waterproofing compound with 3% by weight of Cement and as per manufacture instructions complete all as specified and as directed.
650
-
-
... More
M&L for repairing of cracks by cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
80
-
-
... More
M&L for cleaning the exposed concrete surface of floor/ wall/ chajja by brushing & watering and applying one coat of TAPECRETE P-151 Acrylic Polymer Modified Cementitious slurry consisting 1:2 (1 part of tapecrete : 2 parts of cement by weight) and shall be allowed to dry for 4-6 hours, then applying second coat of 1.5mm thick tapecrete brush topping consisting 1:2:2 (1 part of tapecrete : 2 parts of cement : 2 parts of silica sand by weight) over the first coat and cured for next 2 days complete all as specified and as directed.
300
-
-
... More
M&L for cleaning and removal of vegetation plant of girth not exc. 20cm with roots from the roof surface and making good to disturbed surface in CM 1:4 or PCC 1:2:4 type B-0 as required at site including removal of same material to a distance n. exc. 50m complete all as specified and as directed.
Note: The work shall be executed up to 12.50m height of bldg with all safety measures and no extra payment shall be paid to contractor on this account.
200
-
-
... More
M&L plain cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
5
-
-
... More
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm/75mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and as directed.
460
-
-
... More
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
10
-
-
... More
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
10
-
-
... More
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and directed.
400
-
-
... More
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and as directed.
40
-
-
... More
S&F in repair PVC (SWR) bends of any radius, suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
100
-
-
... More
S&F in repair PVC (SWR) bends of any radius, suitable for 75mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
12
-
-
... More
S&F in repair PVC (SWR) junction single, (single T), equal or unequal suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and as directed.
5
-
-
... More
S&F in repair PVC (SWR) floor trap, plain with gratings including jointing with solvent cement, suitable for 75mm bore PVC pipes complete all as specified and as directed.
8
-
-
... More
S&F in repair PVC (SWR) vent cowls suitable for 110mm bore pipes complete all as specified and as directed.
4
-
-
... More
S&F in repair mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintel hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and as directed.
12
-
-
... More
M&L for cleaning all around at the mouth of existing rain water pipe properly at terrace, wetting and grouting with CM 1:4 and mixed with 3% water proofing compound, area of each grouting n. exc. 0.10 sqm complete all as specified and as directed.
50
-
-
... More
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.
21.15
-
-
... More
M & L brickwork with fly ash bricks,Modular bricks straight or curved on plan exc 6m mean radius, built in, built in CM (1:6) complete all as specified and as directed.
10
-
-
... More
M & L for Brickwork with flyash Modular bricks, straight or curved on plan to any radius in half brick thick walls, built in, in CM 1:4, complete all as specified and as directed.
20
-
-
... More
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
610
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
140
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
440
-
-
... More
M&L for rendering 5 mm thick in cement mortar 1:3 on fair face of brick/concrete surfaces of Ceiling, , finished even & smooth without using extra cement complete including complete all as specified and as directed.
30
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/ tint over a coat of priming complete all as specified and as directed.
140
-
-
... More
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified and as directed.
440
-
-
... More
M&L preparation of new surfaces of of ceiling and applying two coat of white wash on ceiling complete all as specified and directed.
30
-
-
... More
S&F in repair 'E' board of size 600 x 600 x 4mm thick white, prelaminated sett embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped GI imposed grid with 24mm wide T sec exposed flanges which shall be coated white. The frame work shall comprise of main runner made from 0.33 mm thick GI sheet of size 24x32x300mm and spaced at 1200 mm C/C securely fixed to be structural soffits by approved hangers at 1200mm C/C. Hanger of GI wire 4 mm dia to be fixed by approved recoil plug, screw etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall. flash fitting of 1200 mm long cross tee (with double sticking) to be interlocked bet wean main runner at 600 mm centre from 1200x600 mm to modules cross tee longer than 600 mm to be supported independency 600x600 mm do duels to be formed by filling 600 mm long cross tec centrally between the 1200 mm cross tee. Tee perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19x19 mm and 300 mm long of white colour all as per manufacture instruction complete all as specified and as directed.
100
-
-
... More
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors. Including taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and as directed.
40
-
-
... More
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors. Including taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and as directed.
150
-
-
... More
S & F of Rotational moulded PVC water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position including dismantling of OHT of capacity 500 ltrs complete all as specified and as directed.
10
-
-
... More
S & F of Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position including dismantling of OHT of capacity 1000 ltrs complete all as specified and as directed.
10
-
-
... More
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.exc 250 Ltr but n.exc 500 ltr in capacity complete all as specified and as directed.
Note:- Cleaning of tank shall be measured & paid separately.
40
-
-
... More
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.exc 500 ltr but n.exc 1000 ltr in capacity complete all as specified and as directed.
Note:- Cleaning of tank shall be measured & paid separately.
30
-
-
... More
S&F 15 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
10
-
-
... More
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
10
-
-
... More
S&F in repair 15 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
100
-
-
... More
S&F in repair 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
100
-
-
... More
Supply and fixing in repair PVC connections 450mm long, 15 mm size with brass chromium plated nuts at ends complete fixed complete all as specified and directed.
100
-
-
... More
Supply and fixing in repair PVC connections 600mm long, 15 mm size with brass chromium plated nuts at ends complete fixed complete all as specified and directed.
100
-
-
... More
S&F in repairs of ABS body CP health faucet complete set including holder stand and one metre PVC pipe, 15 mm cast copper alloy screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and as directed.
46
-
-
... More
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc exc 250 & n.exc 500 ltrs capacity and writing date of cleaning using synthetic enamel paint complete all as specified and as directed.
40
-
-
... More
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc exc 500 & n.exc 1000 ltrs capacity and writing date of cleaning using synthetic enamel paint complete all as specified and as directed.
30
-
-
... More
Dismantling of asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and as directed.
570
-
-
... More
S&F for 0.50 mm thick pre-painted galvalume aluminium zinc alloy coated steel (550 Mpa) corrugated sheet of any colour, double ribbed trapezoidal profile in desired length etc, as in roof covering/cladding to wall, with joints overlapped and fastened with fasteners using hot dipped zinc coated self drilling hexagonal washer head fasteners complete all as specified and as directed.
520
-
-
... More
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L type or J type or cranck hook complete all as specified and as directed.
50
-
-
... More
S&F in repair for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe - 410- W(Gde - E 250 quality B) complete all as specified and as directed
1300
-
-
... More
M & L for preparing new steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed.
70
-
-