Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Feb 2025
Closing Date19 Mar 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair / Maint / Servecing / Periodical Maint Of Central Air Conditioning Plant Package Ac Plant And Walking Cooler Plants Including Connected Works Under Age (hosp) Under Ge E/m Lucknow
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699420_1Tender No
CWE/LKO/EM/T-169 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and fix in repair of copper tubing 1/2" dia with puff insulation complete all as specified and directed .
50
-
-
... More
Supply and fix in repair of copper tubing 1/4" dia with puff insulation complete all as specified and directed .
50
-
-
... More
Supply only of puff insulation of size1/2" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
20
-
-
... More
Supply only of puff insulation of size1/4" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
20
-
-
... More
Supply only of puff insulation of size5/8" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
10
-
-
... More
Attending the complaint of AC PLANT ,Walk in Cooler , by Refg mechanic /electrician/ technician for non functiong part of compressor , Blower motor , compressor pump , chiller pump , CT fan , AHU Electric panel and all parts of AC Plant at any location ,any capacity make and model and aectified the same as directed by EIC.
Note : - (i) Complaint Should be attended immediately within one hour & to be Rectified the same day at the earliest without effecting of service .( II ) Complaint should be attended 24 hrs through phone , ( III ) Complaint should be detail / attended by Specified Electrician / technician / Mechanic with knowldge of AC Plant ( IV ) Contractor are provide to all necessary T&P to attending and rectified complaints
250
-
-
... More
M&L for 3 x 15 TR capacity AC plant, Descaling of all sets of condensor tubes of central AC plant by disconnecting the condensor from the system, cleaning by descaling pump of suitable capacity of 110 ft head using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter as per below AC Plants. (Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.)
1
-
-
... More
All as per item No 10 but 3x9 TR capacity plant
1
-
-
... More
All as per item No 10 but 2x7.5 TR capacity plant
1
-
-
... More
All as per item No 10 but 3x45 TR capacity plant
1
-
-
... More
All as per item No 10 but 3x80 TR capacity
1
-
-
... More
All as per item No 10 but 3X37.5 TR capacity
1
-
-
... More
All as per item No 10 but 1X60 TR capacity
1
-
-
... More
All as per item No 10 but 3X50 TR capacity
1
-
-
... More
All as per item No 10 but 3X75 TR capacity
1
-
-
... More
All as per item No 10 but 2X8.5 TR capacity
1
-
-
... More
All as per item No 10 but 3X11 TR capacity
1
-
-
... More
All as per item No 10 but 2X12 TR capacity
1
-
-
... More
Carrying out pressure leak testing by nitrogen gas of the system of AC plant for leak proof valve joints, seal & other connected controls etc. including identifying & rectifying of leaks, defects (if any) & maintaining constant pressure of 160 LBS PSI on low side & 200 PSI on high side at least for 24 Hrs of any size and capicity Central AC plant .complete all as specified and directed. :- (Note: The arrangement of T&P & nitrogen gas shall be contractors responsibility).
12
-
-
... More
Cleaning of AHU cooling coil (after Opening front portion of AHU) by applying high air pressure followed by descaling solution Chemical agent & then washing with water pressure using jet pump and reassembling there after complete all as specified and directed by EIC including servicing of AC ducts cleaning etc and setting of grills, louvers and position of proportioning dampers & also minor repair to duct insulation for missing section complete for the following central AC plant :- 3 x 15 TR capacity AC plant
1
-
-
... More
All as per item No 23 but 3x9 TR capacity plant
1
-
-
... More
All as per item No 23 but 2x75 TR capacity plant
1
-
-
... More
All as per item No 23 but 3x45 TR capacity plant
1
-
-
... More
All as per item No 23 but 3x80 TR capacity
2
-
-
... More
All as per item No 23 but 3X37.5 TR capacity
2
-
-
... More
All as per item No 23 but 1X60 TR capacity
1
-
-
... More
All as per item No 23 but 3X75 TR capacity
1
-
-
... More
All as per item No 23 but 3X50 TR capacity
1
-
-
... More
All as per item No 23 but 3X11 TR capacity
1
-
-
... More
All as per item No 23 but 2X12 TR capacity
1
-
-
... More
S&F in replacemet Nylon 'V' belts of A -34 as below sizes
2
-
-
... More
All as per item No 34 but B- 64
2
-
-
... More
All as per item No 34 but B- 81/82
2
-
-
... More
All as per item No 34 but B- 68
2
-
-
... More
All as per item No 34 but C-120
2
-
-
... More
All as per item No 34 but B-78
2
-
-
... More
All as per item No 34 but B-76/74
2
-
-
... More
Taking out the defective hand shut off valve of pressure gauge and supply & fixing new handshut off valve ¼" dia complete all as specified and directed
2
-
-
... More
Taking out the defective safety valve of compressor Make:- ACCEL, Model - SMC - 4 - 65 and supply & fixing new safety valve complete all as specified and directed by EIC.
2
-
-
... More
Taking out the defective condensor safety valve suitable for working pressure of 350 PSI all as specified and directed.
2
-
-
... More
Taking out unserviceable defective finned strip heater and supply and fixing strip heater 3 KW suitable for AC plant including provision of nuts, bolts & washers etc all as specified and directed
25
-
-
... More
Dismantling defective GM gate valve 20 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new GM gate valve15 mm dia with GI Nipple, bends etc nuts & bolts and necessary electric welding all as specified and directed.
1
-
-
... More
Dismantling and removing defective Finns of FRP type cooling tower and supply and fixing new PVC Finns brick containing eleven layers size of brick 600 x 30 x 150 mm complete all as specified and directed.
20
-
-
... More
Taking down carefully rotating sprinkler from cooling towers and S&F new rotating sprinkler assembly from comprising of coupling made out of aluminium alloy with one side 50 to100 mm threaded, and other side with fixing arrangement of 04 Nos sprinkler arm distributed four way with one side ball bearing for easy rotation complete including 04 Nos of PVC heavy duty sprinkler arm pipe of 25 mm dia 300 mm long with six holes of 20 mm dia at equal interval complete with one side threaded check nut and other side dead end complete all as specified and directed.
2
-
-
... More
Taking out wire mesh filter from AHUs , cleaning the filter with castic soda and water with pump pressure and reassembling in their position complete all as specified.( Note Ceaning shall be done three times in a season and payment shall be made in once only .)
10
-
-
... More
Dismantling defective butterfly of size 50 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new butterfly valve 65 mm dia with complete accessories all as specified and directed.
2
-
-
... More
Dismantling defective butterfly of size 65 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new butterfly valve 65 mm dia with complete accessories all as specified and directed.
2
-
-
... More
Dismantling defective butterfly of size 80 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new butterfly valve 65 mm dia with complete accessories all as specified and directed.
1
-
-
... More
Dismantling defective butterfly of size 100 mm dia at drain pipe of cooling tower of AC Plant supply & fixing new butterfly valve 65 mm dia with complete accessories all as specified and directed.
1
-
-
... More
S& F in replacement High Efficiency Particulate Air Filters,(HEPA) Efficiency 99.97% (EU13)down to 0.3 micron filter,mediaThe filters all use a pleated fiberglass media, folded,and separated by aluminum spacers in a metal frame. all as specified and directed
20
-
-
... More
S& F,in replacement fine filter (EU-7)Efficiency 99 % down to 03 micron Filter Media: HDPE Media / Non Woven Synthetic Media Type: HDPE 1 ply+Non Woven Synthetic Media 1 ply+ al. mesh 1, ply, Type - BOX Type, MICRON -3, Frame MOC - Aluminium all as specified and directed
12
-
-
... More
S& F in replacement Pre filter (EU-4)Efficiency 90 % down to 10 micron Filter Media: HDPE Media / Non Woven Synthetic Media Type: HDPE 1 ply+Non Woven Synthetic Media 1 ply+ al. mesh 1, ply Type - BOX Type, MICRON -10, Frame MOC - GI SHEET
12
-
-
... More
Cleaning of AC supply and return duct, diffusers, dampers, coil installed components by Robotic vedio camera at Base Hospital for 04 nos OT including carry out Baceriogical test after cleaning of duct and submission of test report complete all as directed.
2
-
-
... More
Cleaning of AC supply and return duct, diffusers, dampers, coil installed components by Robotic vedio camera at ICU AC plants CH CC /NEFRO/X -RAY AC PLANTS/CMDC AC PLANTS including carry out Baceriogical test after cleaning of duct and submission of test report complete all as directed.
5
-
-
... More
Taking out defective / burnt power contractor from electric panel board and S&F in replacement new Power contactor 3 TF 49 with NO & NC contact , of coil Volatge 220 V all as specified and directed.
2
-
-
... More
S&F in replacement new Power contactor 3 TF 30 in existing LT panel all as specified and directed.
2
-
-
... More
S&F in replacement new Power contactor 3 TF 31 in existing LT panel all as specified and directed.
2
-
-
... More
Supply and fixing in replacement power contactor MNX 18, 3 phase in existing LT panel all as specified and directed.
2
-
-
... More
Taking out defective / burnt power contactor from electric panel board and S&F in replacement new power contactor 3 TS 47.
2
-
-
... More
Supply and fixing in replacement auxillary contactor MNX A1, 3 phase in existing LT panel all as specified and directed.
2
-
-
... More
Supply and fixing in replacement auxillary contactor MNX A2, 3 phase in existing LT panel all as specified and directed.
2
-
-
... More
Supply and fixing in replacement three ways mixing valve switch model No GLB 331.9E of siemence in existing LT panel all as specified and directed.
2
-
-
... More
Taking out carefully defective electronic timer from panel board and S&F new electronic timer Cat No. 800-S/7PU rating 30 to 0/60 to 20 in position complete all as specified Make Siemens/ Selectron
2
-
-
... More
Taking out carefully defective/burnt single phase preventor complete with wiring from LT panel and supply & fixing in replacement in position single preventer complete with wiring all as specified and directed.
2
-
-
... More
Taking out carefully defective / burnt power contactor type ML-1.5 from the LT panel board and supply & fixing new in position in replacement power contractor ML-1.5 all as specified and directed.
2
-
-
... More
Taking out carefully defective / burnt power contactor type MNX 12 from the LT panel board and supply & fixing new in position in replacement power contractor MNX 12 all as specified and directed.
2
-
-
... More
S&F (in replacement) motor terminal plates complete with nut, bolts and washers etc suitable for 75/10/15/20 HP capacity electric motor all as specified and directed.
2
-
-
... More
Disconnecting electrically unserviceable CT fan motor and Supply installation testing and commissioning of CT fan motor complete with other accessories like fan blades etc. 3 phase, 415 Volts, 7.5 HP capacity complete all as specified and directed by EIC.
1
-
-
... More
All as per item No. 71 above but CT fan 3 HP.
1
-
-
... More
All as per item No 71 above but CT fan 2 HP.
1
-
-
... More
All as per item No 71 above but CT fan 1.5 HP.
1
-
-
... More
S& F fresh compressor oil into the plant at different locations in Lucknow Cantt with in a distance of not exceeding 6 Km complete all as specified and directed.
100
-
-
... More
Disconnecting electrically three phase 440 volt induction motor 20 HP unbolting it and transporting to the contractor workshop opening it to taking out burnt out copper windings, cleaning of stator slots by means of CTC or petrol and rewinding it with suitable size/gauge copper enameled wire including insulating/varnishing material, replacement of damaged ball bearing of suitable size and transporting it to the site and refixing to its original position and making necessary electrical connection and testing complete all as directed by Engr-in-Charge.
1
-
-
... More
All as above but capicity of 50 HP
1
-
-
... More
All as above but capicity of 37.5 HP
1
-
-
... More
All as above but capicity of 12.5 HP
1
-
-
... More
Dismantling of monoblock pump of capacity 5 HP from its foundation after unbolting it and servicing/overhauling of pump complete including replacemnt of worn out spares such as ball bearings,gland bush,gland packing,nuts and bolts of gland,greasing and oiling of all moving parts,grinding/turning etc. and reassembling the pump including re-installation to its original position including testing of water leakage all as specified and directed.
1
-
-
... More
Supply and charging refrigerant gas CFC compatible to R-22 with new sealed cylinder having refrigerent capacity 61 Kg complete all as specified and directed. (Make:- Floran / Mafron) Note:- 1. After filiing the gas empty cyelinder will be deposited in MES Store yard .
10
-
-
... More
Supply Fixing Testing and Commissioning (In repair) of factory built Hot Water coil, casing GI, copper tube, tube diameter 12.7mm, MS Header, fins 0.15mm Aluminium , Air Flow 10000 CFM, Fin lenth 1541mm, Fin height 1207mm, coil area 20 Sqft , 02 Coil row deep,
1
-
-
... More
M&L for dismantling old UNSV Scroll compressor & Supply installation, testing & Commissioning (In repair) of hermetically sealed scroll type compressor 3ph 415v 50HZ of capacity not less than 13 TR connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
2
-
-
... More
M&L for dismantling old UNSV Scroll compressor & Supply installation, testing & Commissioning (In repair) of hermetically sealed scroll type compressor 3ph 415v 50HZ of capacity not less than 7.5 TR connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
2
-
-
... More
M&L for dismantling old UNSV Scroll compressor & Supply installation, testing & Commissioning (In repair) of hermetically sealed scroll type compressor 3ph 415v 50HZ of capacity not less than 5 TR connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
4
-
-
... More
M&L for dismantling old UNSV Scroll compressor & Supply installation, testing & Commissioning (In repair) of hermetically sealed scroll type compressor 3ph 415v 50HZ of capacity not less than 11 TR connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
2
-
-
... More
M&L for dismantling old UNSV condenser & Supply installation, testing & Commissioning (In repair) of water cooling shell and tube condenser capacity not less than 13 TR connecting suction, discharge & liquid line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
2
-
-
... More
M&L for dismantling old UNSV chiller & Supply installation, testing & Commissioning (In repair) of water cooling shell and tube chiller capacity not less than 13 TR connecting suction, discharge & liquid line by jointing with copper rod & oxygen flame and making electric connection, wiring with sensor complete all as specified and directed.
2
-
-
... More
Supply & Fixing in replacement PLC (Microprocessor) controller unit with display suitable for 37.5 TR make Blue Star, Model No XWC3S-039ARY having the following featres or any other controls requird to make system function and safe,
(i) Run time eqalization,
(ii) Auto Start,
(iii)Memory back up,
(iv) Built in Time delay
1
-
-
... More
Supply & Fixing in replacement PLC (Microprocessor) controller unit with display suitable for 11 TR make Blue Star, having the following featres or any other controls requird to make system function and safe,
(i) Run time eqalization,
(ii) Auto Start,
(iii)Memory back up,
(iv) Built in Time delay
1
-
-
... More
Supply,Installation testing and commissioning (In repair) Hot water Generator of capacity 25KW for controlling the Humidty including suitable capacity panel boad cabling work connection of water pipe in existing AHU complete all as specified and directed by EIC.
1
-
-
... More
Supply Fixing Testing and Commissioning (In repair) of factory made built cooling coil of size (76x32x10 inch) , casing GI, copper tube , MS Header , 03 Coil row deep, suitable for 3x37 TR ac plant AHU installed at ICU , CHCC , complete all as specified and directed by EIC.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%