Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 May 2024
Closing Date15 Jun 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical type including MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating of cap 400 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including preparation of MS surface and applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and as directed.

7

-

-

... More
Supply and Fixing drop Out Fuse unit,expulsion type for outdoor air break gang operated switch,single pole,mounted on and including insulators for 11 KV working pressure fixed to and including MS channels with nuts,bolts & washers etc,synthetic bounded fuse tube complete suitable for current carrying capacity upto 100 Amps complete all as specified and as directed.

25

-

-

... More
Excavating in trenches exc 1.5 m but n exc 3.0 m in depth for foundation, shafts, wells, cesspits, manholes, pier holes, etc. as in soft/loose soil and getting out complete all as specified and as directed.

4.86

-

-

... More
Excavating in trenches, n exc 1.5 m wide exc 1.5 m but n exc 3.00m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 3.00m in depth and getting out in soft/loose soil complete all as specified and as directed.

0.97

-

-

... More
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.

0.49

-

-

... More
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.

5.83

-

-

... More
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.

0.82

-

-

... More
M&L for Cable route indicator showing "HT Cable" and route/joint of cable with arrow made of PCC 1X2X4 type B1 duly rendered with plaster 10 mm thick of size 40 x 50 x 20cm fixed and erected on PCC plateform of sixe 40 x 40 x 10 CM goruted in grounts duly painted on both sides with HT Cable Route complete all as specified and as directed.

80

-

-

... More
Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and as directed.

9

-

-

... More
M&L for mild steel work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.

9

-

-

... More
Disconnecting and taking out existing unserviceable defective HT cable any size any type from trenches/duct/ poles including taking out old bricks complete all as specified and as directed. Note : Excavation and earth work measured and separately under appropriate items of this BOQ.

1110

-

-

... More
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area 70 sq mm 3 core complete all as specified and as directed.

80

-

-

... More
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area 95 sq mm 3 core complete all as specified and as directed.

400

-

-

... More
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area 120 sqmm 3 core complete all as specified and as directed.

450

-

-

... More
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor, 11000V grade, of cross section area 150 sqmm 3 core complete all as specified and as directed.

80

-

-

... More
Supply laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000V grade, of cross section area 185 sqmm 3 core complete all as specified and as directed.

100

-

-

... More
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil complete all as specified and as directed.

324

-

-

... More
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand complete all as specified and as directed. Note:- For payment punned depth shall be measured.

65

-

-

... More
Supply and laying PCC cable cover class HV type 1 flat size 300mm x 180mm x 40mm complete all as specified and as directed.

4440

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and as directed.

224

-

-

... More
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.

99

-

-

... More
Supply and laying GI Pipe light grade with all fitting and fixed complete to walls/poles/underpass and ceilings or laid in floors complete all as specified and as directed.

-

-

-

... More
50 mm bore

40

-

-

... More
80 mm bore

40

-

-

... More
100 mm bore

70

-

-

... More
Supply and fix in replacement of battery charger suitable for 110 Volt DC, 100 AH battery bank complete all as specified and as directed.

1

-

-

... More
Supply & fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mouning 12 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete complete all as specified and as directed.

10

-

-

... More
S&F DC MCB DP 4-16 Amps, DP, 'C' series, rupturing capacity 10KA, suitable for DC ciurcuit complete all as specified and as directed.

10

-

-

... More
S&F in repair of copper cable 2.5 sqmm 3 core complete all as specified and as directed.

80

-

-

... More
Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx25mm thick complete all as specified and as directed.

4

-

-

... More
Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx20mm thick complete all as specified and as directed.

5

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified and as directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m.

15

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified and as directed. Note : GI wire and protection pipe upto 7.5 Mtr length from earth electrode shall be included in quoted rate of item.

15

-

-

... More
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.

50

-

-

... More
M&L for disconnecting the electric supply to the transformer, opening the top cover of 11 KV/0.433KV step down transformer upto 500 KVA capacity by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LH/HT bush from the sheel and replacement for burnt out/unserviceable LT/HT bush, studs and gasket of buchholes to avoid leakage of oil, refilling of oil into the transformer after required repair works complete all as specified and as directed. Note : (a) HT/LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items of this BOQ. (b) Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.

5

-

-

... More
M&L for painting of transformer upto 500 KVA including connected LT bus duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. and writing date of paint with black synthetic enamel paint complete all as as directed.

8

-

-

... More
Supply and filling of fresh transformer oil in transformers having diaelectric strength 45 KV in 3 mm gap including testing complete all as specified and as directed.

2200

-

-

... More
M&L for purification, filtration and dehydration of transformer oil from transformer installed at various indoor/outdoor sub station by ultra high vacuum filtration machine with stream line filtration plant at a temp 60 to 70 degree celsius and achieving minimum dieectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and as directed.

4500

-

-

... More
Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 100/1A including taking out unserviceable one connectiong testing and commissioning complete all as specified and as directed.

8

-

-

... More
Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 150/1A including taking out unserviceable one connectiong testing and commissioning complete all as specified and as directed.

7

-

-

... More
M&L for repair/overhauling of off load tap changer of step down transformer 11KV/433V including connection complete all as specified and as directed.

10

-

-

... More
M&L for cutting wild grass, bushes, creaper, unwanted vegetation and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance from inside / surrounding of E/M sub station (transformers) including cutting creapers from barbed / cattle fencing of the sub stn as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura complete all as specified and as directed. Note :- The item shall be operated maximum two times in entire period of contract in the same installations and area measured separately each time.

5000

-

-

... More
Supply and fixing in replacement of unserviceable Automatic voltage regulating relay (AVR) suitable for 110 Volt + 3% AC supply, 50 Hz complete all as specified and as directed. Make : EMCO Cat Part No EE-301E/Ashida/ABB/Areva

1

-

-

... More
M&L for taking out old unserviceable HT/LT coil removing insulation complete by brushing coil,cleaning the the inner body complete making free from dust and dirt,all impurities, applying paper insulation(IS specified) of transformer complete of capacity 63 to 630 KVA complete all as specified and as directed.

960

-

-

... More
M&L for re-winding of HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 630 KVA complete all as specified and as directed.

850

-

-

... More
M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 630 KVA complete all as specified and as directed.

440

-

-

... More
Supply and fixing in repair transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 800 grams complete all as specified and as directed.

8

-

-

... More
Supply and fixing in repair transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 1200 grams complete all as specified and as directed.

6

-

-

... More
M&L for disconnecting electrical connections of step down transformers 11KV/0.433 KV after taking proper electric shutdown and labour and T&P for opening/stripping of the same, draining out oil in clean barrels, lifting the core & coil assembly, washing and cleaning dust, dirt & sludge deposit from all parts, cleaning and polishing of tapping contact point, making internal connections, providing new cork sheet gasket packing 10 mm thick and pouring in the insulating oil in the transformer, re-assembling the transformer after repair work, checking for any leakages including replacement of any unserviceable parts required to make it serviceable all as directed and placing the transformer at original or any other location and making all electric connections including testing the transformer to the entire satisfaction of Engr-in-Charge of following capacities. Note : (i) Spares required for replacement of unserviceable parts shall be measured and paid separately under relevant item of this BOQ as supply only and cost of labour thereof is deemed to be included in unit rate quoted. (ii) Cost of transportation, loading, unloading from sub station to workshop & back including its installation, testing & commissioning complete is deemed to be included in unit rate quoted.

-

-

-

... More
50 KVA to 160 KVA

2

-

-

... More
150 KVA to 250 KVA

4

-

-

... More
300 KVA to 400 KVA

4

-

-

... More
500 KVA to 630 KVA

2

-

-

... More
Supply only LV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:-

-

-

-

... More
50 KVA to 160 KVA

8

-

-

... More
150 KVA to 250 KVA

6

-

-

... More
300 KVA to 400 KVA

10

-

-

... More
500 KVA to 630 KVA

4

-

-

... More
Supply only HV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:

-

-

-

... More
50 KVA to 160 KVA

2

-

-

... More
150 KVA to 250 KVA

4

-

-

... More
300 KVA to 400 KVA

4

-

-

... More
500 KVA to 630 KVA

4

-

-

... More
Supply only LV bushing with gasket suitable for 11KV/433V distribution transformer of following capacites:-

-

-

-

... More
50 KVA to 160 KVA

8

-

-

... More
150 KVA to 250 KVA

6

-

-

... More
300 KVA to 400 KVA

10

-

-

... More
500 KVA to 630 KVA

4

-

-

... More
Supply only HV bushing with gasket and arcing horn suitable for 11KV/433V distribution transformer of following capacites:-

-

-

-

... More
50 KVA to 160 KVA

2

-

-

... More
150 KVA to 250 KVA

4

-

-

... More
300 KVA to 400 KVA

4

-

-

... More
500 KVA to 630 KVA

4

-

-

... More
Replacement of old unserviceable/damaged temperature gauge with new temperature gauge suitable for transformer of any capacity and any type including all necessary accessories i.e. nipple, socket, complete all as specified and as directed.

16

-

-

... More
S&F aluminium lugs for the following sizes complete all as specified and directed :-

-

-

-

... More
25 to 70 Sqmm

160

-

-

... More
95 to 120 Sqmm

150

-

-

... More
150 to 185 Sqmm

120

-

-

... More
185 to 240 Sqmm

80

-

-

... More
300 to 400 Sqmm

20

-

-

... More
Heat shrinkable PVC sleeve suitable for XLPE LT UG cable fo following sizes complete:-

-

-

-

... More
50 sqmm to 95 Sqmm.

20

-

-

... More
120 sqmm to 300 Sqmm.

30

-

-

... More
Supply and fixing in replacement selector switch as per sample or as directed.

10

-

-

... More
Disconnecting and taking down HT UG cable from HT pole/transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-

-

-

-

... More
95 Sqmm 3 core.

25

-

-

... More
120 Sqmm to 300 Sqmm 3 core.

7

-

-

... More
Disconnecting and taking down HT UG cable from HT pole/transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-

-

-

-

... More
95 Sqmm 3 core.

4

-

-

... More
120 Sqmm to 185 Sqmm 3 core.

2

-

-

... More
Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables:-

-

-

-

... More
95 Sqmm 3 core.

10

-

-

... More
120 Sqmm to 185 Sqmm 3 core.

5

-

-

... More
M&L for painting of steel tubular HT/LT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint complete all as specified and as directed.

40

-

-

... More
All as per item No 61.00 here-in-before but for 2 pole structure including bracings complete all as specified and as directed.

15

-

-

... More
All as per item No 61.00 here-in-before but for 4 pole structure including bracings complete all as specified and as directed.

15

-

-

... More
Supply and fixing in replacement of MCCB 630Amp rating 4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 50 KA complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement of MCCB 400Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 50 KA complete all as specified and as directed.

10

-

-

... More
Supply and fixing in replacement of MCCB 250Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.

11

-

-

... More
Supply and fixing in replacement of MCCB 160Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.

8

-

-

... More
Supply and fixing in replacement of MCCB 100Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.

14

-

-

... More
Supply and fixing in replacement of MCCB 250Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.

9

-

-

... More
Supply and fixing in replacement of MCCB 200Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.

8

-

-

... More
Supply and fixing in replacement of MCCB 100Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement of MCCB 63Amp rating, 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 35KA complete all as specified and as directed.

10

-

-

... More
M&L for making of surface for painting duly scrubing the existing paint and apply of two coats of existing synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and as directed.

30

-

-

... More
M& L for welding works to LT Panel/Bus Bar/Feeder pillar box for fixing hinges, locking arrangement or reapir pitted area etc at site complete all as specified and as directed.

15

-

-

... More
Supply and fixing cable tray 300mm wide including all required accesories for supporting and carrying out LT cable upto transformer complete all as directed.

50

-

-

... More
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 200 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existing design etc including nut, bolt, complete all as specified and as directed.

30

-

-

... More
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 400 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existing design etc including nut,bolt,complete all as specified and as directed.

40

-

-

... More
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 600 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and as per existing design etc including nut,bolt,complete all as specified and as directed.

20

-

-

... More
Supply and fixing after disconnected of electric supply to VCB and replace the unserviceable Over current and earth fault protection relay, Vx=24 -240 V AC/24-250 V DC,In=1A/5A(0,1In-40In), Ion=1 A/5A(0,01Ion-2Lon) complte all as specified and as directed. Note:- Fixing of protection relay shall be carried out through engineer/technician of OEM.

3

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering /cladding to wall with self tapping screws complete all as specified and as directed.

200

-

-

... More
M&L for framed work as in MS sheet section,hinges, angle iron etc complete confirming to Fe-410-O or Fe 310-0 complete all as specified and as directed.

600

-

-

... More
Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar box suitable for rating 80 Amp to 100 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

20

-

-

... More
Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar box suitable for rating 125 Amp to 200 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

15

-

-

... More
Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar box suitable for rating 200 Amp to 400 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

15

-

-

... More
Supply and Fixing in replacement of spreader terminal for MCCB in LT panel/Feeder pillar box suitable for rating 500 Amp to 630 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

12

-

-

... More
Supply and fixing in replacement of existing LT feeder pillar box out door type of size 60cm x 60cm x 40cm made out of MS sheet of 3.15mm thick with alluminium busbar duly powder coated and mounted on angle iron frame made out of size 50 x 50 x 6mm, 90cm high consisting of the following accessories and make as approved by GE from approved list:- (a) MCCB 4 pole 415 volts 160 Amps, 25 KA adjustable type -01 Nos (for incoming). (b) Aluminium bus bar 200 Amp for three phase and 100 AMp neutral complete. (c) Digital volt meter with selector switch-01 Nos (d) Digital voltmeter ameter and On/Off switch-01 Nos Note : Drawing of LT Feeder Pillar shall be got approved from Engineer-in-Charge before procurement.

3

-

-

... More
M&L for carrying out calibration of Air Circuit Breaker 630 Amp to 1000 Amps, over fault relay, earth fault relay, checking of alignment of ACB isolating contacts, servicing of electronic operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section. Removing perished monoplus compound cleaning and re-insulating with LT taps wherever necessary, also supply and fixing Outdoor/indoor type ACB mounting panel conopy as per suitable size 2.00 mm thick CRCA sheet, front and back opening and locking arrangement of ACB mechanism, with fixing arrangement at foundation and including repalcement of minor items like nuts, bolts, washer etc of authorised dealer/representative and refixing the ACB breaker in its original position and testing entire satisfaction of Engineer-in-charge. Note : (i) The major spare parts measeured and paid separetely against items at BOQ. (ii) Calibration of ACB shall be got carried out from autorised representative of OEM

3

-

-

... More
Supply and Fixing in replacement of spring charging motor capacity 110/230 Volt suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-

... More
Supply only shunt trip coil suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-

... More
Supply only under voltage trip device suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

3

-

-

... More
Supply only Adapter type terminal suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

3

-

-

... More
Supply only in replacement of Spring charge indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

3

-

-

... More
Supply only trip indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-

... More
Supply only position indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-

... More
Supply only on/off push button suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-

... More
Supply only on/off neutral CT suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.