Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date29 May 2024
Closing Date27 Jun 2024
Tender Amount₹ 28,50,000
Costs
EMD
₹ 57,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_656536_1Bid Award Id
ViewTender No
8100/B/806/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
ditto- all as above but of capacity 7.5 HP to 12.5 HP complete all as specified and directed.
3
-
-
... More
Supply only Bearing of motor existing sizes as per requirement at site complete all as specified and directed.
10
-
-
... More
Supply only Bearing of blower shaft pulley as per existing sizes at site complete all as specified and directed.
5
-
-
... More
Supply only Fan Blades of existing sizes complete all as specified and directed.
3
-
-
... More
Supply only Connection Plate complete for three phase star delta winding connection of motor including lugs/thimble and wire complete all as specified and directed.
5
-
-
... More
M&L for opening/dismantling monoblock pump set of chilled water expansion tank of OTs cap 1 HP and complete overhauling rewinding including oiling, greasing and reassembling after replacing unserviceable parts and testing all as directed.
4
-
-
... More
M&L for opening/dismantling centrifugal pump set Condenser pump 25 HP/chiller pump 20 HP and complete overhauling including Lathe machine work , oiling, greassing of ball bearing, reassembling after replacing unserviceable parts and testing all as directed. (Note- Spare parts will be measured and paid seaparately under following item)
4
-
-
... More
Supply only Impeller as per existing size complete all as specified and directed.
2
-
-
... More
Supply only GM Bush complete all as specified and directed.
10
-
-
... More
Supply only Steel Studs complete all as specified and directed.
16
-
-
... More
Supply only Wear rings of existing sizes complete all as specified and directed.
10
-
-
... More
Supply only Shaft seal complete all as specified and directed.
10
-
-
... More
Supply only Shaft sleeves complete all as specified and directed.
10
-
-
... More
Supply only Coupling nut bolts and bush complete all as specified and directed.
20
-
-
... More
Supply only Coupling as per existing size including shaft key and lathe work complete all as specified and directed.
3
-
-
... More
Supply only New Shaft complete including lathe work as per existing sizes for Becon make Pumps complete all as specified and directed.
2
-
-
... More
Supply only Cast iron flangs (Halves) complete all as specified and directed.
12
-
-
... More
Supply only Bearing 6207,6309,6211,6311 as per requirement at site complete all as specified and directed.
16
-
-
... More
Supply only Gland Box complete all as specified and directed.
6
-
-
... More
Supply only Gland dori packet as per existing size complete all as specified and directed.
12
-
-
... More
S&F in replacement of Butterfly valves of size 80/65mm of Chiller pipe lines and condenser pipelines as per existing sizes of Central AC Plant MH including packing and making good the chiller pipelines insulation complete all as specified and directed.
2
-
-
... More
All as per item No. 24 above but 125 mm complete all as specified and directed.
1
-
-
... More
All as per item No. 24 above but 150 mm complete all as specified and directed.
4
-
-
... More
Supply and fix in repair 3 pole contactors of ranges MNX-18 including suitable auxillary contact A1/A2 and side mounting add on block complete all as specified and directed.
5
-
-
... More
All as per item No. 27 above but MNX-25 complete all as specified and directed.
15
-
-
... More
All as per item No. 27 above but MNX-32 complete all as specified and directed.
20
-
-
... More
All as per item No. 27 above but MNX-40 complete all as specified and directed.
5
-
-
... More
S&F in replacement Side mounting add-on block with Auxiliary contact 1No+1Nc /2NO+2NC suitable for MNX 9 to 40 contractor complete all as specified and directed.
15
-
-
... More
Supply and Fixing in replacement Single phase preventor in LT panels for Pump and motors complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement of connector HT5/HT4 /ST3 etc in the LT panel for connection of cables and wires as per existing and as per requirement on site complete all as specified and directed.
20
-
-
... More
Supply and fix bakelite connector strip for current rating more than 30/63 Amp for connection of cables and wiring in three phase circuits in the LT panel of AHUs for connection of cables and wires as per requirement on site.
15
-
-
... More
S&F in replacement O/L relay 28 to 63 Amps 3 pole, directly operated. All as specified and as directed.
10
-
-
... More
Supply and fix protecting relay with UL rating 6A/277 VAC and 8A/28 VDCwith cat part NO as per existing RXM4AB1P7 230 Volt 50 Hz 6/250 VAC as per IEC61810-1 fit for RXZE2 series socket current limited to rating of relay or socket whichever is less all as specified and as directed
4
-
-
... More
Supply and fix in repair NO -NC connecter, connected back side of the push start/ stop button green/Red colour complete assembly including push button for the interlocking control panel of AC Plant for compressor, chiller,motors and pumps complete all as specified and as directed.
10
-
-
... More
Supply and fix in repair fuse assembly in the LT panel of Central AC plants as per existing make and sizes complete all as specified and directed.
6
-
-
... More
Supply and fix in repair ET timer in the LT panel of Central AC plants as per existing make and sizes complete all as specified and directed.
5
-
-
... More
Supply and fix in repair LED indicating lamp assembly of green/Red/yellow/blue colour in the LT Panel ,AHU Electric Panel and electric control panel of central AC Plant as per requirements at sites.. complete all as specified and directed.
10
-
-
... More
Supply and fix in repair RYB selector switch in the electric panel of central AC Plant complete all as specified and directed.
10
-
-
... More
Supply and fix in repair Toggle switch SPST 10 Amps Make KAYCEEL ,L&T or equivalent complete assembly in the AHU electric panel of central AC Plant complete all as specified and directed.
5
-
-
... More
Supply and fixing in replacement of 3 phase Digital Volts Meter 0-500 Volts AC 0-5000 Amps 3½ Digit Resolution High Accuracy, Guaranteed to Class 1.0 / Class 0.5 Unique Feature,TRUE RMS meters Guaranteed performance even under extremely poor power quality conditions Site selectable CT ratios.complete all as specified and directed.
8
-
-
... More
Supply and fixing in replacement of 3 phase Digital Amp Meter Wide range, AC / 0-5000 Amps 3½ Digit Resolution High Accuracy, Guaranteed to Class 1.0 / Class 0.5 Unique Feature,TRUE RMS meters Guaranteed performance even under extremely poor power quality conditions Site selectable CT ratios in Ammeter complete all as specified and directed.
8
-
-
... More
Supply and fixing in replacement of Temperature control meter with sensor & thermostat in the AHU panels with its complete assembly and sensors of high Resolution & High Accuracy of temperature complete all as specified and as directed.
5
-
-
... More
S&F in replacement MCB four pole 63 Amp 10 KA 415 V complete all as specified and directed
4
-
-
... More
S&F in replacement MCB four pole 32 Amp 10 KA 415 V all as specified and directed by Engr-in-Charge.
8
-
-
... More
S&F in replacement MCB three pole 32 Amp 10 KA 415 V all as specified and directed by Engr-in-Charge.
7
-
-
... More
S&F in replacement MCCB 100 Amps 4 pole 415 V 50Hz breaking capacity 25 KA confirms to IS/IEC complete all as specified and directed.
1
-
-
... More
Ditto- all as above but of capacity 125 Amps 4 Pole 415 Volts 50 Hz complete all as specified and directed.
1
-
-
... More
M & L for servicing of LT distribution panels of AHU Of MH of Central AC plant complete cleaning of panel including CTs, and bus bar Chamber welding of hinges incl replacement of U/S internal wiring with copper wiring (as per existing size wire )including replacement of coroded thimble/lugs and connector as per existing size/ type complete all as specified and directed.
(Note :Cost of wires,lugs, insulating tape roll and thimbles for internal wiring shall be included in the quoted rates and Other major spare part shall be measured and paid separately.)
10
-
-
... More
M & L for servicing of main LT distribution panels of Central AC plant including control panel complete cleaning of panel including CTs, and bus bar Chamber welding of hinges incl replacement of U/S internal wiring with copper wiring (as per existing size wire )including replacement of coroded thimble/lugs and connector, replacement of unserviceable volt/amp meters etc as per existing size/ type complete all as specified and directed.Note :-(Cost of wires,lugs insulating tape roll and thimbles for internal wiring shall be included in the quoted rates and Other major spare part shall be measured and paid separately.)
1
-
-
... More
M&L for dismantling/opening and replacement of safety valves in the condenser of central AC plant of existing size and make (i.e pressure rating 1 MPa and 40-105 deg celcius of temperature ranges and of sizes 3/4" ) for Carrier 30HXC model Central AC Plant duly recommended by the OEM i.e Carrier complete all as specified and directed.
2
-
-
... More
M&L for dismantling/opening and replacement of Filter drier core Model XW12GB008E of size 1- 1/8" ODF SOLDER with Bloc/Cores 02 Pressure Max 500PSIG/3.5M Pa complete in the chiller unit of central AC plant of existing size and make for Carrier Make Central AC Plant 146 TR duly recommended by the OEM complete all as specified and directed.
2
-
-
... More
M&L for dismantling/opening and replacement of External Oil Filter of Compressor of size 2- 1/4" Pressure Max 500PSIG/3.5MPa complete in the chiller unit of central AC plant of existing size and make for Carrier Make Central AC Plant 146 TR duly recommended by the OEM complete all as specified and directed.
1
-
-
... More
M&L for dismantling/opening of Internal Oil Filter part No 2001972 of Compressor complete in the chiller unit of central AC plant of existing size and Make Central AC Plant 146 TR duly recommended by the OEM complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement of emergency pressure safety switch/Head Pressure (HP) switch with Sensor cum control switch assembly including push button Model cat part No H20PSM pressure controler with OFF 1.45 MPa and ON 0.80 MPa complete as per existing for Carrier Make and Model-30HXC155A Central AC Plant installed in the Chiller unit for restart of Chiller/compressor after resetting of Alarming condition complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of Loading/Unloading Coil capacity 24 volt for Compressor of and Model-30HXC155A Central AC Plant 1x146TR installed on the compressor complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of Hydraulic Coil capacity 24 volt 20 Watt / 24 Volt 10 watt for Compressor and Model-30HXC155A Central AC Plant 1x146TR installed on the compressor complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of Pressure transducer switch assembly for condenser of Chiller Plant of 30HXC model Central AC Plant 1x146TR complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement of Oil Pump 30HXC 410 volt 3 phase 50 Hz EBV 18 , 115 V ±10% , 120 Watt for Compressor and Model-30HXC155A Central AC Plant 1x146TR installed for the compressor complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement for HRC fuse model CHNT RT 36 of cap 125- 160 Amp of Chiller Electric Panel of HXC Carrier Central AC Plant 1x146TR complete all as specified and directed.
12
-
-
... More
Supply and fixing in replacement for Contactor assembly 3TF 47 Make SIEMENS complete with Relay and aux contact 1No+1 NC/2NO+2NC with coil control voltage 110-115 Volt of Chiller Electric Panel 30HXC model Central AC Plant complete all as specified and directed.
2
-
-
... More
_ditto_ as above but 3TF 48 complete all as specified and directed.
2
-
-
... More
_ditto_ as above but 3TF 44 complete all as specified and directed.
2
-
-
... More
_ditto_ as above but 3TF 45 complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement for CHNT ON/OFF Controller 1.6 -2.5 A of Chiller Electric Panel of Carrier 30HXC model Central AC Plant complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement for connecter with thimble for Control transformer 400 volt 50 Hz and of Chiller Electric Panel of 30HXC Central AC Plant complete all as specified and directed.
25
-
-
... More
Repair of Microprocessor control display card including replacement/repair of unserviceable push buttons and repair and commisioning testing by setting of programming in the microprocessor control assembly and resetting of control of cut out temperatures of Chilled waters and condensor water by qualified and experienced refrigerant mechanic complete as per existing for and Model-30HXC155A Central AC Plant1x146TR installed in the Chiller unit complete all as specified and directed.
2
-
-
... More
Repair of Microprocessor mother board of Chiller Plant/ SCPM card of compressor complete including replacement/repair of unserviceable ICs and components and commisioning testing by setting of programming in the microprocessor control assembly by qualified and experienced refrigerant mechanic/OEM complete as per existing and Model-30HXC155A Central AC Plant 1x146TR installed in the Chiller unit complete all as specified and directed.
1
-
-
... More
Repair of lekage of gas/oil from compressor by qualified and experienced refrigerant mechanic by overhauling and disconnection and dismantling and detecting the lekage of gas and compressor oil by checking of oil sight glass by using desired measuring instruments and repair in situ by using dead nuts gasket & washers as required to stop the leakages and cleaning of compressor outer surface and checking and tightening of all electrical circuits and gas pipelines and all connecting valves as per existing for and Model-30HXC155A Central AC Plant 1x146TR complete all as specified and directed.
2
-
-
... More
M&L for Overhauling and repair of Compressor Screw type Carrier Model No 06NW2300S5NA-A00 three phase 400 Volts 50 Hz 63 KW by replacement of all Ball Bearing and rewinding of motor burnt/short winding with existing size Copper insulated winding and repairing of evaporator tubes by repalcing of brass dead plugs etc precisely and accuratley through highly sensitive machineries, commissioning and testing of insulation resistance,winding resistance etc complete all as specified and as per recommendation of OEM of the equipments
1
-
-
... More
Loading/unloading/rigging/lifting with Chain pulley and heavy Labour machineries for Compressor Screw type of Model No 06NW2300S5NA-A00 three phase 400 Volts 50 Hz 63 KW for Central AC Plant from existing platform and refixing including transporting to the OEM/Auth dealer for repair complete all as specified and as directed.
2
-
-
... More
M&L for Commissioning testing by vaccumising through pump, Leak testing by Nitrogen after refixing/reinstallation of Compressor Screw type Model No 06NW2300S5NA-A00 three phase 400 Volts 50 Hz 63 KW after complete repair all as specified and as per recommendation of OEM of the equipments .Note : Charging of Gas also Includes in this job, but Gas will be measured separately under relavant items of Sch 'A'
1
-
-
... More
Supply and fixing in replacement of water flow switch assembly complete for flow control of chilled water and condensate water pipelines of liquid temp range 1- 100 deg celcius and max pressure 10 Bar complete as per existing after disconnection and dismantling of electrical connections for Make and Model-30HXC155A Central AC Plant 1x146TR complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement of Water Energy switch assembly with Sensing device complete for flow control of chilled water in the Chilled water pipelines near three way mixing valves of AHUs complete as per existing after disconnection and dismantling of electrical connection for Carrier Make and Model-30HXC155A Central AC Plant 1x146TR complete all as specified and directed.
4
-
-
... More
M&L for dismantling/opening air filter, nut bolts, tray for AHU general servicing including descaling and cleaning of cooling coil from both sides with coil cleaner solution and brushing suitable for the AHU tubing,correcting tension in belts, checking and correcting allingment of shaft pulley of motor and blower motor, washing condenser and filter of AHU with blower of capacity 2000 to 12000 CFM complete all as specified and directed.
46
-
-
... More
M&L for UPVC/CPVC pipeline of dia 25mm including fittings and clamps laying and fixing on roof and walls and floors by dismantling of old choked unserviceable pipelines and laying of new as per existing including nitril vinyl foam insulation fixed around the complete pipelines covered with pvc packing tapes required for drain out of chilled water from the Air handling unit condensate water tray by making good of disturbed surfaces complete all as specified and directed.
60
-
-
... More
M&L for descaling of condenser unit by descaling agent including opening and refixing in original postion all as required at site for shell and tube condenser unit of central AC Plant by using proper descaling solution like SR 601 by brushing, cleaning by recirculating pressure pumps by pressure water including replacement of gas kit of both ends of condensor all as specified and directed for 1x146 TR capacity plant .
3
-
-
... More
Material & labour for Repair and servicing of FRP cooling tower of cap 175 TR of Central AC Plant of MH by Dismantling of cooling tower for removing of top cover and cleaning of PVC Fills ,Choked nozzles,PVC loavers and replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust and oiling of motor and checking of serviceablity of motor complete all as directed by Engineer-in-charge.(Note:- Others major spare parts shall be measured separately)
6
-
-
... More
M & L for replacement of old PVC FILLS by new of suitable length and sizes (each length lXBXH= 2'X1'X8") and fixing and spreading and laying complete in the cooling tower uniformly such that the water falls down uniformly in tthrough the complete cooling towers of capacity 175 TR. Note :-(Cost of nut bolts ,washers and other minor spares shall be included in the quoted rates )
450
-
-
... More
M & L for replacement of old unserviceable PVC Spray Nozzle as per existing size and type of the Cooling tower by new of suitable length and sizes and fixing complete in the cooling tower such that the water falls down uniformly through the complete cooling towers of capacity 175 TR. Note :-(Cost of nut bolts ,washers and other minor spares shall be included in the quoted rates )
4
-
-
... More
M&L for Chilled water pipeline insulation of pipeline sizes 80 mm to 125 mm with removing the old worn out insulation and complete scrapping and applying varnish over the surface and refixing of C shaped nytril vinyl insulation of 25mm/40 mm thickness with applying proper adhesive and packing with insulating tapes complte complete all as specified and as directed
60
-
-
... More
M&L for repair of AHU Duct including replacement of canvas clothing complete as per existing sizes including rivetting joints and thermal insulation including air tight packing of ducts by using rubber glands complete all as specified as directed by Engr-in charge,
6
-
-
... More
Taking down CT fan electric motor from Cooling tower, dismantling and opening of motor 3 phase 440 Volt 50 HZ, cap 12.5 HP for rewinding and overhauling, taking out old burnt copper winding wires cleaning of slots, rewinding of motor with super enamelled coper wire of suiltable size or guage including insulation material applying varnish and drying properly at slow temprature, reassembling the motor after proper greasing of ball bearing, replacing nut bolts with washer and refixing the same at existing platform complete all as specified and directed.
1
-
-
... More
Taking down Hepa filter from drafts and closure, removing OT light and S&F Hepa filter size 610x202x305mm box type frame-Al,EU13 grade, micron 0.3, efficiency 99.99% & IPD 25mm wg as per sample Make Eec (Enviromental Engineering Co) or equivalent company with proper Test Certificate recommissioning properly and testing for satisfactory function after replacing the Hepa filter complete all as specified and directed.
48
-
-
... More
Taking down old and choked Screen filter without any damage to the assests and S&F screen filter size 900x1000 mm duly fabricated with superior quality of filter cloth suitable for filteration of light as well as refigerated air complete complete all as specified and directed.
48
-
-
... More
Supply and Fixing in repair of 'V' belt of sizes A-22 ,A-26 ,A-31, A-40,A-48,A-31, A-64 or any other size and type complete all as specified and directed
42
-
-
... More
M&L for replacement of PVC cable 6 sqmm single core stranded copper conductor including taking down unserniceable cable and connection with strip heater unit with woven or braided fabric insulation covered on cables near the heater so that save it from the high temperature of strip heaters complete all as specified and directed.
100
-
-
... More
Supply and fix in repair Strip heater 3 KW finned type 240 Volt total length 33.5" and H to H length 32.75" for AHU of AC plant complete all as specified and directed.
44
-
-
... More
S& F Humidistat cum digital type thermometer with 99% efficiency and quick response time in AHU room.
5
-
-
... More
S& F Dry wet Bulb type industrial thermometer complete all as specified and directed.
5
-
-
... More
S & F in repairs water pressure gauge 7-10 Kg pressure 100 mm dia complete all as specified and directed.
8
-
-
... More
S & F in repairs water pressure gauge U- shape syphon of mild steel with butterfly valves suitable for 7-10 Kg pressure 100 mm dia guages complete all as specified and directed.
10
-
-
... More
S & F in repairs vertical type industrial thermometer for chilled water pipelines and condensate water pipelines temperature complete all as specified and directed.
12
-
-
... More
M&L for repair to Humidification system of AHU including replacement of unserviceable chilled spray nozzle and repair of unserviceable monoblock pumps and testing of Humidification and dehumidification system complete all as specified and as directed
6
-
-
... More
M&L for repair of leakage of Chiller pipeline of AHU of size as per existing including fittings and fixtures, clamps laying and fixing on roof and walls and floors by dismantling of old choked unserviceable pipelines and arresting of leakage by making necessary arrangement/ laying of new as per existing including nitril vinyl foam insulation fixed around the complete pipelines covered with pvc packing tapes by making good of disturbed surfaces complete all as specified and directed.
2
-
-
... More
M&L for repair of CI water tank of Chilled water expansion tank of OTs AHU including welding works and replacement of gate valves after complete cleaning and painting and insulation repair complete all as specified and as directed.
1
-
-
... More
S& F in replacement of fire dampers of AHU of Central AC Plant including dismatling of old Unserviceable fire dampers without any damage to existing AHU Ducts complete all as specified and as directed
2
-
-
... More
Supply and refilling of carrier synthetic screw compressor oil of Central AC plant model 30 HXC after detection of leakage and low level from the compressor oil sight glass from Compressor/chiller units of Central AC plant and top up to the desired level through oil pump precisely after leakage repair if any and testing the chiller/compressor units for obtaining the desired cooling temperatures complete all as specified and directed
50
-
-
... More
Supply and refilling/charging of refrigerant gas R- 134 A to the compressor of Central AC plant after detection of leakage of Refrigerant gas from Compressor/chiller units of Central AC plant and top up to the desired level after flushing with nitrogen and leakage repair if any and testing the chiller units for obtaining the desired cooling temperatures complete all as specified and directed
65
-
-
... More
M& L for repair of Exhaust Fan motor 85 watt 900 RPM 0.41 Amp of OT return air duct including dismantling and testing repair / rewinding and refixing after repair including replacement of broken XPM jali as per existing shape & size
5
-
-
... More
Material & Labour for AC Plant Duct cleaning & servicing including cleaning of difusser grills of supply air & return air ducting by robotics method / manual as per requiremet at site or as directed and checking of leagae if any and reapir in situ including safely removal of HEPA Filters/Pre filters/Screen filters from the existing air diffusers grills and ducts complete all as specified and directed.
90
-
-
... More
M&L for servicing of OT automatic doors complete all as specified and directed for 04 Nos doors.
2
-
-
... More
Material & Labour for Leakage packing of HEPA filters diffusers grills and ducts by hot glue gun and adhesive materials complete all as specified and as directed for 6 Nos OTs
1
-
-
... More
M&L for replacement of cable copper conductor 25 sq mm 4 core passing throuh pipe or fixing on cable tray wall roof with suitable arrangement of fixing material complete all as spd and directed.
78
-
-
... More
Material & Labour for Validation test of HEPA filter efficiency test of OTs performed by specialist technician and engineer of the designated field and perform the three type of testsas follows:
(a) ACPH Test (b) Integrity Test / PAO (Poly Alpha Olefin) Test Note : The testing team visit the OTs of MH and carry out the above tests by proper inspection of HEPA Filters Diffusers and arresting of Leakage before carrying out the Tests.The Test Reports must be provided within a week after testing with proper indication of results and reference values complete all as specified and directed.
2
-
-
... More
Material and labour for cement concrete for floor/foundation filling and mass concrete using type B1 (1:2:4) (20 mm graded aggregate ) complete all as specified and directed.
0.5
-
-
... More
M&L for Brick work with sub class B straight or curved on plan n.exc 6m mean radius built in cement mortor 1:4 complete all as specified and directed.
0.5
-
-
... More
M&L for rendering for Brick works surfaces of concrete surface of supporting pillar in 1:4 .10mm thick complet all as specified and directed
5
-
-
... More
Demolition of brick or stone /bolder masonary or pipe supporting pillars,kerbs,apron laid in any mortor complete all as specified and directed.
1
-
-
... More
Supply and fixed "Central AC Plant GE (W) MH Bareilly" Glow sign board of size 3x2 Meter with with PVC letters of height 8" including LED 15 watts module light of each letter, alcopanel of 5mm both side about 6 Sqmtr with requireed qty of iron Frame for AC Plant MH complete all as directed.
1
-
-
... More
Supply and fixed Notice board of size 2x3 feet suitable for fixing of standing order fire order duty roster etc complete all as directed.
2
-
-
... More
Supply and fixed sign board for details of Central AC plant and fire fighting installed Pump of size 2x3 feet with vinyal letters of height 1"complete all as directed.
2
-
-
... More
Supply and fixed Electric shoke treatment chart plastic cotted of size 2x3 feet complete all as directed.
2
-
-
... More
Supply and fixed Fire chart plastic cotted of size 2x3 feet complete all as directed .
2
-
-