Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date11 Feb 2025
Closing Date4 Mar 2025
Tender Amount₹ 57,71,000
Costs
EMD
₹ 1,11,565Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697468_1Tender No
84360/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down cement or cement lime plaster of any discription on brick/ concrete or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
1240
-
-
... More
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed.
1050
-
-
... More
M&L for rendering 15 mm thick on concrete/ brick/stone surface wall in cement mortar 1:4 mixed with liquid WPC @ 200 ml/50Kg of cement or as per manufactures's instructions, finished fair and even, complete all as specified and directed. Note:- WPC shall be measured and paid separately as supply only.
160
-
-
... More
Supply only integral water proofing compound (liquid) complete all as specified and directed.
6
-
-
... More
M&L for 15mm thick rendering in CM 1:4 on any faces of brick or concrete surfaces of walls , drain & finishing the surface even and fair without using extra cement complete all as specified and directed.
30
-
-
... More
M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of oil bound distemper with roller application over a coat of primer over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed.
1050
-
-
... More
M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of cement base paint with roller application over a coat of primer complete all as specified and directed.
150
-
-
... More
M&L for complete removal of extg treatment with mechanical device of old plastered surfaces of wall and applying two coat of white wash (match with new surface) complete all as specified and directed.
1800
-
-
... More
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
15
-
-
... More
M&L for Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching,coping , roof kerbs, mud stop, padding , flooring etc and similar work complete all as specified and directed.
4
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
340
-
-
... More
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed .
310
-
-
... More
M&L non skid joint free coloured tiles (1st quality/ premium quality) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exc. 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.(toilet,bath,Kitchen)
30
-
-
... More
M&L Prepolished machine cut kota stone slab flooring 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including complete laid over and including 20mm thick screed bed CM (1:6) complete all as specified and directed.
360
-
-
... More
M&L Prepolished machine cut kota stone 20 mm thick as in riser of step, skirting,dado and pillar etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including laid over 15mm thick rendering CM (1:4) complete all as specified and directed.
30
-
-
... More
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specifically provided for complete all as specified and directed.
6
-
-
... More
M&L for 75mm thick PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection and finished even and smooth without using extra cement ,including making joint 12mm wide to the full depth of PCC at @ 3 mtrs C/C (Max) and at every change of direction and filling the same with & including bitumen sand complete all as specified and directed.
75
-
-
... More
M& L for sand filling under floors or in foundation incl watering and consolidation complete all as specified and directed.
5
-
-
... More
Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc complete all as specified and directed.
290
-
-
... More
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre complete all as specified and directed.
290
-
-
... More
M&L 4mm thick non asbestos fibre cement building boards in ceiling flat or sloping, fixed or laid/ inserted to timber/GI/Aluminium framework with screw complete all as specified and directed.
290
-
-
... More
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges , etc complete all as specified and directed
1410
-
-
... More
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
1335
-
-
... More
S&F pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
75
-
-
... More
Taking down timber roof trusses, coupled rafters or trussed beams clear span above 4 metres & upto 8 metre complete all as specified and directed.
18
-
-
... More
Taking down timber roof trusses, coupled rafters or trussed beams clear span above 4 metres & upto 8 metre for renewal of any defective member ( Timber enewed to be measured separately) and reassembling complete all as specified and directed.
15
-
-
... More
M&L for second class hard wood clean sawn timber framed and fixed in scantling, roof truss and rafters complate all as specified and directed.
0.92
-
-
... More
S&F rolled section as in main and cross beams hip and angle,hollow section, jack rafters, purlins, box type section where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc including steel primer coat, welding, confirming to Fe410 Gde E-250) quality B complete all as specified and directed.
7385
-
-
... More
Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, hollow section, channel or flat sections) including distance pieces, cleats etc. Fe-290W(GdeE-165) complete all as specified and directed.
4600
-
-
... More
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exc 22.5cm and n exc 30cm and diameter of neck 16mm to 20mm complete all as specified and directed.
200
-
-
... More
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
500
-
-
... More
S&F galvanised welded steel wire fabric as extra reionforcement to RCC members like ceilings, chajja’s, beams, columns parapet walls, waste slab etc including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed.
100
-
-
... More
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including flush pipe, brackets, rubber bush, washers etc complete all as specified and directed.
6
-
-
... More
S & F in repairs 15 mm bore brass chromium plated mixer hot & cold water screwed down, screwed for iron pipe complete all as specified and directed.
6
-
-
... More
S & F 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
6
-
-
... More
S&F in repair 15 mm bore CP Stop valve / angle valve screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
12
-
-
... More
S&F 15 mm bore CP Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
2
-
-
... More
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid as in floor in trenches ,fixed to wall etc complete all as specified and directed.
30
-
-
... More
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid as in floor in trenches ,fixed to wall etc complete all as specified and directed.
40
-
-
... More
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
6
-
-
... More
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
30
-
-
... More
All as per item No.44 above but 20mm bore
30
-
-
... More
M&L for GI tubing 15mm dia medium grade with all fittings fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
30
-
-
... More
All as er item No.46 above but 20mm dia
30
-
-
... More
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia complete all as specified and directed.
16
-
-
... More
S&F for 1000 ltrs capacity rotational moulded polyethylene water storage tank double layered, ISI engraved (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling of water tank complete all as specified & directed.
1
-
-
... More
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
2
-
-
... More
Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth etc brick wall complete all as specified and directed.
35
-
-
... More
S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with 'P' or 'S' trap front or back inlet including footrest (excluding fluxing cistern and flush pipe) complete all as specified and directed.
6
-
-
... More
S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed
12
-
-
... More
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe chain plug brackets complete all as specified and directed. .
6
-
-
... More
S&F in repair 15mm bore, brass chromium plated pillar cock (foam flow) two ways screwed down for pipe and fixed complete all as specified and directed.
6
-
-
... More
S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) of 32mm bore suitable for wash hand basin complete all as specified and directed.
6
-
-
... More
S&F in repairs 600x450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
6
-
-
... More
S & F in repairs CP shower rose 125mm dia alongwith shower arm complete all as specified and directed.
6
-
-
... More
S&F aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
6
-
-
... More
S&F for curtain rails ,Harrison rails,mild steel, cromium plated including fixing brackets, stops, rollers etc complete all as specified and directed.
40
-
-
... More
S&F in repair 150 mm square PTMT grating with openable flap (Min weight 100 gms) complete all as specified and directed.
12
-
-
... More
S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 45cm long complete all as specified and directed
6
-
-
... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
10
-
-
... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
12
-
-
... More
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed.
5
-
-
... More
Refixing the chowkhat or frame with shutters(without taking off shuters from the frame) of any description exc 1.50 Sqm but not exc. 4 Sqm each in the same opening or in other opening complete all as specified and directed.
15
-
-
... More
Refixing the shutters of any description exc 1.00 Sqm but not exc. 2 Sqm each in the same opening or in other opening complete all as specified and directed.
8
-
-
... More
Mild steel farmed work as in doors (as in ckowkats) or gates of angle or other section with guest plates rail, brasses rail etc exculsive of steel sheeting or other covering hanging also fastening and fixing complete confirming to Gde Fe-290 (Gde E-165) including shop coat of red oxide including prepration of surface before fixing complete all as specified and directed.
200
-
-
... More
S & F 35 mm thick flush shutters, board solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
15
-
-
... More
S&F 35 mm thick 2nd class hard wood , glazed skeleton door shutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed.
15
-
-
... More
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 174 of SSR 2020 (Part-II) complete all as specified and directed.
10
-
-
... More
S & F Solid PVC door frame for PVC doors, Kitchen cabinet of size 50mm x 47mm made out of 5mm PVC sheet reinforced with MS square tube, as shown on drawings as per manufacturers specification complete all as specified and directed.
30
-
-
... More
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
30
-
-
... More
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
20
-
-
... More
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
30
-
-
... More
S&F 125 mm long medium weight, stainless steel Butt hinges complete all as specified and directed.
50
-
-
... More
S & F mild steel 200mm, ordinary rat tail rod pattern door springs including roller and roller plate complete all as specified and directed.
12
-
-
... More
S & F Double shutter Box type steel windows comprised of tubular frame and shutters made out of outer frame ERW tube 'P' section (60x45x25)mm and shutters of ERW tube 'P' section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel windows will be double shutter external glazed and internal wire glazed including 10mm square bars as in grill complete all as specified and directed by engr- in - charge.
NOTE- The quoted rate against the above item shall also include-
(i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames
(ii) PCC block for embedding lugs.
10
-
-
... More
S&F Double shutter Box type steel ventilators comprised of tubular frame and shutters made out of outer frame ERW tube 'P' section (60x45x25)mm and shutters of ERW tube 'P' section (50x35x20)mm openable shutters side hung including piston hinges with two nos of MS tower bolts 150 mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings / opening for cooler / AC where required. Steel ventilators will be double shutter external glazed and internal wire glazed including 10mm square bars as in grill complete all as specified and directed by engineer -in -charge.
NOTE- The quoted rate against the above item shall also include-
(i) 4 Nos MS steel lugs of 20x5 mm MS flat 20 cm long over all welded to frames
(ii) PCC block for embedding lugs.
6
-
-
... More
S&F for framed work such as grills, grating etc. with ends of bars shouldered and/or riveted or forged into spike, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tank and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
50
-
-
... More
S & F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
11
-
-
... More
S&F 3.0 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
3
-
-
... More
S&F 3.0 mm thick shhet glass ordinary quality and glazing with oil putty in square n exc 0.5Sqm in each pane complete all as specified and directed.
10
-
-
... More
M&L for applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer including preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth complete all as specified and directed.
30
-
-
... More
M & L for applying one coat of synthetic enamel paint including preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
50
-
-
... More
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new or previously untreated steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed.
15
-
-
... More
M & L for broken bricks loose filling with aggregates of gauge 40 to 80mm in sub base / floor complete all as specified and directed.
3
-
-
... More
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed.
2
-
-
... More
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 150mm bore of pipe complete all as specified and directed.
15
-
-
... More
M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed.
15
-
-
... More
M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed
15
-
-
... More
M&L for providing pre-cast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover (for manholes and drains) including necessary form work set in CM 1:6 with and including demolition complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately)
1
-
-
... More
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with cli complete all as specified and directed.
80
-
-
... More
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
158
-
-
... More
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
113
-
-
... More
All as per item No.95 here in before but one socket out let 5/6 Amps on independent board board controlled by one switch but not below the board complete all as specified & directed.
15
-
-
... More
All as per item No-95 here in before but one socket out let 5/6 Amps controlled by one switch on the same board with other switches complete all as specified & directed.
10
-
-
... More
All as per item No.95 here in before but one socket outlet 3/5 pin, 5/6 Amps controlled by 1 one way switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed.
5
-
-
... More
All as per item No.95 here in before but 2.5 sqmm PVC FRLS insulated stranded copper conductor cable and for one socket outlet 3/6 pin, 15/16 Amps controlled by one 1 way switch on indepdendent board complete all as specified and directed. NOTE-For item No 95 to 99 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface steel conduit of suitable size fixed on surface with using PVC rawl plug. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of rns of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade).
(iv) The rate of all type of conduit, fittings, rawl plugs etc deemed included in items.
15
-
-
... More
Supply and fix switch piano flush type, sigle pole, 5/6 Amp one way, 230 volts complete all as specified and directed.
143
-
-
... More
Supply and fix switch piano flush type, sigle pole, 15/16 Amp one way, 230 volts complete all as specified and directed.
15
-
-
... More
Supply and fix socket outlet, 5/6 Amp, flush type, 5 pin, 230 volts complete all as specified and directed.
30
-
-
... More
Supply and fix socket outlet, multi purpose 3 pine 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed.
15
-
-
... More
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 volts complete all as specified and directed.
8
-
-
... More
S&F for ceiling rose surface bakelite 50 x 25 mm size 3 terminals complete all as specified and directed.
78
-
-
... More
Supply and fix lamp holder insulated body with back plate for battern fitting complete all as specified and directed.
25
-
-
... More
Supply and fix rotory steeped type electronic fan regulator mini flush type 100 watt 230 volts complete all as specified and directed.
14
-
-
... More
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 volt complete all as specified and directed.
8
-
-
... More
Supply and fixing LED bulb 15 watt, single phase, 230 volts, AC supply suitable for lamp holder complete all as specified and directed.
25
-
-
... More
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps, 240 Volts IK-08 as per IEC 61439-3 complete all as specified and directed.
6
-
-
... More
Supply & fix surface / wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall / celing with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified and directed.
30
-
-
... More
Supply & fix, surface ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2 X 2 environmental friendly new generation aesthetically ultra modern recess mounting with high brigthness SMD LEDs as light source with reflected cover elecronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified and directed.
10
-
-
... More
Supply & Fix outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodized and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20 M long bracket made out of 40 mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm flat iron / MS clamps & 12 mm dia bolts, nuts & washer etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and directed.
8
-
-
... More
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
6
-
-
... More
Supply & Fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly altra modern energy saving, decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and directed.
6
-
-
... More
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified and directed.
265
-
-
... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified and directed.
Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length
145
-
-
... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified and directed.
Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
120
-
-
... More
Taking down distribution boards any size any type including MCB/TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified and directed.
5
-
-
... More
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .
1
-
-
... More
Supply and fix MCCB 4 pole 100 to 125 Amp, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified and directed.
1
-
-
... More
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
4
-
-
... More
Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
4
-
-
... More
Supply & fix MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
12
-
-
... More
Supply & fix MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit)
10
-
-
... More
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
14
-
-
... More
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 complete all as specified and directed.
2
-
-
... More
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repaire/ servicing & painting with one coat of synthetic enable paint and re-hanging/ re-fixing in original position but including replacement of three coer flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as specified and directed
20
-
-
... More
Supply, laying and commissioning & testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
209
-
-
... More
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed.
47.87
-
-
... More
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
27.77
-
-
... More
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
20.1
-
-
... More
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed.
1182
-
-
... More
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as specified and directed.
13.54
-
-
... More
Supply and fixing in replacement of GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed.
12
-
-
... More
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
6
-
-
... More
Supply and fix medium grade galvanized iron tubes with all fitting such as tees bends elbow etc fixed on walls / floors of 20 mm bore complete all as specified and directed.
90
-
-
... More
Supply and fix medium grade galvanized iron tubes with all fitting such as tees bends elbow etc fixed on walls / floors of 25 mm bore complete all as specified and directed.
40
-
-
... More
Supply anf fix gun metal gate valve of size 20 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as specified and directed.
6
-
-
... More
Supply anf fix gun metal gate valve of size 25 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as specified and directed.
1
-
-
... More
Supply anf fix ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 20 mm bore complete all as specified and directed.
6
-
-
... More
M&L for drilling and tapping cast iron water mains (in position) for branch connections of the internal 20 mm dia complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%