Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jan 2024
Closing Date29 Jan 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No-2 above but of size 35 sqmm 3.5core, complete all as specified and directed at site.

200

-

-

... More
All as per item No-2 above but of size 70 sqmm 3.5core, complete all as specified and directed at site.

200

-

-

... More
All as per item No-2 above but of size 120 sqmm 3.5core, complete all as specified and directed at site.

200

-

-

... More
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed.

270

-

-

... More
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil,complete all as specified and directed at site.

189

-

-

... More
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed at site.

81

-

-

... More
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed.

81

-

-

... More
Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed.

8

-

-

... More
Taking out old LT U/G cable from trench and relaying LT cable after repair in trench (Note:-Excavation and other related items will be measured and paid separately) a)240Sqmm3.5 core XLPE Cable complete all as specified and directed at site.

50

-

-

... More
b) 95Sqmm3.5 core XLPE Cable complete all as specified and directed at site.

50

-

-

... More
c)70Sqmm3.5 core XLPE Cable complete all as specified and directed at site.

50

-

-

... More
d) 25 SQMM 4 Core XLPE Cable complete all as specified and directed at site.

50

-

-

... More
e)16 Sqmm 4 core XLPE Cable complete all as specified and directed at site.

50

-

-

... More
Surface dressing n.exc 30 cm deep including cutting of bushes, small tree, grass etc complete all as specified and directed at site.

1800

-

-

... More
M&L for disconnecting burnt end or portion of 10 sq mm to 185 Sq mm 3 1/2 core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and realaying the same, and reconnecting the cable by removing burnt protion of cable and preparing fresh terminals of LT cable to pole / main switch etc complete all as specified.

120

-

-

... More
Supply and fix in repairs aluminium lugs for fixing armoured cable in panel of following sizes taking down old one . a) from 10 to 16 sqmm 4 core cable complete all as specified and directed at site.

40

-

-

... More
b) from 25 to 35 sqmm 4 core cable complete all as specified and directed at site.

40

-

-

... More
c) from 50 to 70 sqmm 3.5 core cable complete all as specified and directed at site.

40

-

-

... More
d) from 95 to 120 sqmm 3.5 core cable complete all as specified and directed at site.

40

-

-

... More
e) from 150 to 185 sqmm 3.5 core cable complete all as specified and directed at site.

40

-

-

... More
f) from 240 to 300 sqmm 3.5 core cable complete all as specified and directed at site.

40

-

-

... More
Detecting of fault of LT UG cable (any place any length any type /size) with help of vehicle mounted cable fault locator including detecting exact location of cable fault and remove of cable for rectification.

2

-

-

... More
M&L for painting of LT pole 8/9 m long (above ground) after cleaning the complete body surface of pole by rubing with emery paper to remove old paint,dust etc and applying two coat of aluminium paint by brush and zebra painting with enamel paint of 20 cm alternating layer with black and white colour for 1 Mtr from bottom all as directed.

350

-

-

... More
M&L for machine spray painting of the under mentioned LT Panel by rubbing, scraping of old paints with emery paper, cleaning and preparation of smooth surfaces complete including writing INCOMING/OUTGOING,LOCATION etc with approved quality paint all as specified and directed by Engineer – in – Charge.

150

-

-

... More
Disconnecting and taking out old existing unserviceable junction box and S&F in position new sheet moulding compound (SMC) junction boxes of size 450mmX450mmX150mm depth made out of 1.8mm thick CRCA sheet with front side hinged opening having rubber linking & locking arrangement with nut and bolt and arrangement for incoming and outgoing cable and wire. The box shall provided with and including 4 Nos, 100 Amps aluminum bus bar mounted on porcelain insulators including connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI round clamps, nuts, bolts & washers and Provn of cable from bus bar to MCB and 1 MCB 5 to 32 AMP including two coat of synthetic enamel paint over a cot of red oxide primer complete all as specified and directed.

450

-

-

... More
Supply, install, testing and commissioning in repairs of LT Cubicle panel of suitable size, outdoor type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts , springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz , 3 phase 4 wire system 1100 volts grade, coloured heat shrinkable sleaving, internal connection should be provided with aluminium strip of suitable size and necessary grouting/ foundation all as required at site and comprising following:-:- a) Ammeter, digital including selector switch, b) CT of required capacity -03 No, (c) Voltmeter Digital type including selector switch, (d) Phase indicating lamps -03 Nos, e) Control wiring, (f) Copper conductor wiring ., (g) BusBar made out of aluminium of 400 amps capacity mounted on insulators 04 nos. & (h) MCCB 3 Pole 415 Volt 250 Amps Capacity, 36 KA - 01 Nos ( for incoming ).

7

-

-

... More
Material and labour in repairs for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, incl taking out old pipe complete all as specified and directed including clamps, nut bolt and washers.

80

-

-

... More
M&L for Boring under road /foot path upto 1.5 mtr depth for inserting of 80 mm dia GI tubing for drawing UG cable by manual or mechanical complete all as specified and directed.

100

-

-

... More
M&L in repairs straight through LT Cable joint including cutting of fault cable and preparation and jointing complete of size 16 sqmm to 50 sqmm 3.5 core complete including taking out old joint.Make : Dension/MS-Seal/Fontech.

9

-

-

... More
M&L in repairs straight through LT Cable joint including cutting of fault cable and preparation and jointing complete of size 70 sqmm to 150 sqmm 3.5 core complete including taking out old joint.Make : Dension/MS-Seal/Fontech. .Make : Dension/MS-Seal/Fontech.

10

-

-

... More
M&L in repairs straight through LT Cable joint including cutting of fault cable and preparation and jointing complete of size 185 sqmm to 240 sqmm 3.5 core complete including taking out old joint.Make : Dension/MS-Seal/Fontech. .Make : Dension/MS-Seal/Fontech.Note ;-excavation/returning filling in will be measured and paid separately

5

-

-

... More
S&F in repairs cable route indicator consisting of CI disc,round 150mm dia,6mm thick duly embossed with lettering "MES LT Cable" and fixed with mild steel angle iron of size 50x50x6mm 600mm long with bolts and nuts embedede in ground in route of cable including PCC block all as directed by Engineer-in-Charge

100

-

-

... More
Material and Labour required for re-stretching/ restringing of existing loosed / sagged ACSR over head conductor of any type and size including supply and binding wire/aluminum tape of required size, opening from insulators as fixed on pole after taking proper electric shut down from concerned staff including taking down unserviceable conductor from OH line and proper binding with additional conductor and restringing on line, complete all as directed by Engineer-in charge

1

-

-

... More
Supply and fixing (in repair) MCCB 100 Amp 4 pole 16 KA all as specified and directed. Make- L&T,C&S Havells

2

-

-

... More
Supply and fixing (in repair) MCCB 160 Amp 4 pole 36 KA all as specified and directed. Make- L&T,C&S Havells

2

-

-

... More
Supply and fixing (in repair) replacement MCCB 200 Amp 4 pole 36 KA all as specified and directed.Make- L&T,C&S Havells

2

-

-

... More
Supply and fixing (in repair) MCCB 250 Amp 4 pole 36 KA all as specified and directed. Make- L&T,C&S Havells

2

-

-

... More
Supply and fixing (in repair) MCCB 400 Amp 4 pole 36 KA all as specified and directed. Make- L&T,C&S Havells

2

-

-

... More
Supply and fixing (in repair) MCCB 630 Amp 4 pole 50 KA all as specified and directed.Make- L&T,C&S Havells

1

-

-

... More
Supply and fixing (in repair) on load Changeover switch 415 Volt in sheet metal enclosure 4 pole of capacity 200 Amp.Make Indo Asian/Standard/HPL.

1

-

-

... More
Supply and fixing (in repair) on load Changeover switch 415 Volt in sheet metal enclosure 4 pole of capacity 400 Amp.Make Indo Asian/Standard/HPL.

1

-

-

... More
Material and labour for MS sheet 2mm/3.15mm thick for making doors of panel boards/feeder pillar boxes including taking out the old damaged doors.

30

-

-

... More
M & L for Trimming of tree branches (touching on HT/LT OH lines) upto 10 Cms girth at any height, carefully by taking proper shut down, including suitable disposal of cut tree branches all as directed.

20

-

-

... More
Material and labour in repairs for clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, drilling holes for bolts, in any shape or size inclusive of one primer coat, one under coat and one finishing coat of aluminium paint.

0.3

-

-

... More
Replacement of damaged doors of panel boards/feeder pillar boxes by cutting, bending, welding MS sheet to suit with the existing MCCB's including providing hinges. Note ;- MS sheet will be measured and paid in separate item.

4

-

-

... More
M& L (in repair) Aluminium bus bar in panels all as specified and directed by Engineer- in-charge .

7

-

-

... More
Supply and laying in repairs weather proof cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections

450

-

-

... More
Disconnecting and taking out old existing unserviceable street light fitting of any description and Supply & fixing Street light fitting IP-66 powder coated pressure die cast aluminium housing with high power LED as lighting source with heat resistant toughtened glass 70 W LED with 10kv surge protection complete with all assessaries of capacity 70 watt. Make-Havells cat part No. ENDURACITYLINERNEOSL70WLED757PASYBOTG

90

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25mm X 4mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.

3

-

-

... More
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.

1800

-

-

... More
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)

600

-

-

... More
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)

900

-

-

... More
M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 4.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)

300

-

-

... More
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.

68

-

-

... More
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.

6

-

-

... More
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.

8

-

-

... More
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.

12

-

-

... More
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.

30

-

-

... More
S&F factory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.

10

-

-

... More
S&F in repairs sheet metal enclosure distribution board SPN 2 ways complete all as specified and directed.

2

-

-

... More
S&F in repairs MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.

10

-

-

... More
S&F in repairs MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.

10

-

-

... More
S&F in repairs MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.

4

-

-

... More
S&F in repairs MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.

300

-

-

... More
S&F in repairs MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.

50

-

-

... More
S&F in repairs MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.

50

-

-

... More
S&F in repairs MCB, TP, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.

12

-

-

... More
S&F in repairs MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.

20

-

-

... More
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.

12

-

-

... More
S&F in repairs sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one Triple pole MCB 32 Amp complete all as specified.

12

-

-

... More
S&F in repairs10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS10WLED865SPCWH or equivalent in Bajaj / CG.

50

-

-

... More
S&F in repairs 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865SPCWH or equivalent in Bajaj / CG.

502

-

-

... More
S&F in repairs recess mounting LED luminaire of size 2'x2' white 34 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR34W LED840S or equivalent in Bajaj /CG.

120

-

-

... More
S&F in repairs recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. INTEGRAHED LR12W LED840S or equivalent in Bajaj /CG.

4

-

-

... More
S & F in repairs LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.

24

-

-

... More
S&F,in repairs testing energy saving, die cast aluminium housing IP 65 protection, 25 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL25WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO

6

-

-

... More
S&F,in repairs testing energy saving, die cast aluminium housing IP 65 protection, 30 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:-Havells Cat No. ENDURA CITYLITEPLAT PLUS SL30WLED 757S ASYBOPC or equivalent iin Bajaj/ Philips / CG/ WIPRO

5

-

-

... More
S&F,in repairs testing energy saving, die cast aluminium housing IP 65 protection, 70 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Havells Cat No. JETA PROFL70WLED757LT G or equivalent iin Bajaj/ Philips/CG/ WIPRO

5

-

-

... More
S&F in repairs 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.

30

-

-

... More
Supply, laying and testing 6 Sqmm, 2.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items. complete all as specified and directed at site.

100

-

-

... More
S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed.

10

-

-

... More
Supply only wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed.

100

-

-

... More
M&L in replacement for factory made gate light junction box, single phase, 2 wire, 240 volts, weather proof pole mounted made out of 1.63 mm thick MS sheet of size 250x150x100mm depth, with properly insulated aluminium buses - 02 Nos of 32 Amps rated current cap with holes for connecting of cables, hinged door and locking bolt, handle complete all as specified and directed.

4

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.

8

-

-

... More
M&L for earthing complete in replacment with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip of size 32/6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed at site.

4

-

-

... More
Disconnecting, taking down & removing carefully the existing Geyser of any capacity from any position/locations for repairs / fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the geyser, hanging/fixing the repaired geysers in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.

10

-

-

... More
S&F in replacement heating element of 1.5KW any type as per sample ISI marked complete all as specified and directed.

10

-

-

... More
S&F in replacement heating element of 2.0KW any type as per sample ISI marked complete all as specified and directed.

10

-

-

... More
Supply and replace complete Geyser assembly as per exisiting sample including rubber washer and nuts & bolts suitable for water heater capacity 25 Ltrs of existing make.complete all as specified and directed at site.

2

-

-

... More
M&L for repairing leakage of inner copper tank of geyser (any make) 25/50 litres capacity by brazing including all necessary denting etc complete all as specified and directed

10

-

-

... More
S&F in replacement thermostat suitable for 25 Ltr geyser complete all as specified and directed.

10

-

-

... More
S&F in replacement thermostat suitable for 50 Ltr geyser complete all as specified and directed.

10

-

-

... More
S&F in replacment PVC pipes of 450mm long best quality, heavy duty for geyser of 15mm dia with brass connecting nuts/couplers complete all as specified and directed.

10

-

-

... More
S&F in replacment indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed.

10

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed at site.

21

-

-

... More
M & L piont wiring complete copper conductor 1.5 Sq mm size (nominal area)PVC insuloated FRLS unsnearned cable 1100 V grade conforming to IS 694 drawn in and including 1.6 mm thick concealed ER W stove enameled rigid steel conduit conforing to IS:9537 of size not less than 25mm dia including flame proof fittings such as MS junction bos,. MS couo-ling uninors bends, reducers inspection albow seeling conduits, plugs etc and also including single core standed copper conductor 1.5 Sq mm PVC insulated unsheathed FRLS cable as earth wire to common earth adn connected to earth doily and body of the flameproof lumiaires an drawn in the same concealed conduit complete all as specified and directed for following:-(a) One flame proof light/ fan point controlled by single pole one way 10 Amp flame proof ON-OFF rotary switch.

21

-

-

... More
S & F in repairs Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed at site.

21

-

-

... More
S & F in repairs LED light fitting 1x 16 watt flame proof , CMRI certified recommended for gas / vapour/ group of IIA& IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened gkass with LED tube light fixture , driver, holder, connector etc . complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed at site.

18

-

-

... More
S & F in repairs LED light fitting 1x 50 watt flame proof , CMRI certified recommended for gas / vapour/ group of IIA& IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened gkass with LED tube light fixture , driver, holder, connector etc . complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed at site.

4

-

-

... More
Supply only in replacement motor, single phase for 200/250mm Exhaust fan as per sample complete all as specified and directed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.