Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Dec 2023
Closing Date5 Jan 2024
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Blower assembly 5.5 TR complete all as specified and directed.

10

-

-

... More
S & F in replacement of AC, single phase, 220V, 50 Hz Condensor fan motor 1/3 to 1/2 HP suitable for 5.5 TR package out door unit.

15

-

-

... More
S & F in replacement of Filter dryer with flare nut suitable for package AC of Make - Blue Star / Emersion/Catch oil / Danfoss

15

-

-

... More
S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 22 of 11TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON

10

-

-

... More
S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 407C of 16.5TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON

6

-

-

... More
Supply and fixing in replacement of Liquid line valve,5.5 TR of size 1/2 inch or of suiteable size as per sample and testing the systemleakproof before and after fixing of new valve. Make:DANFOSS / EMERSON

10

-

-

... More
Supply and fixing in replacement of Liquid line valve,5.5 TR of size 5/8 inch or of suiteable size as per sample and testing the systemleakproof before and after fixing of new valve. Make:DANFOSS / EMERSON

10

-

-

... More
Supply and fixing in replacement of Liquid line valve,5.5 TR of size 7/8 inch or of suiteable size as per sample and testing the systemleakproof before and after fixing of new valve. Make:DANFOSS / EMERSON

10

-

-

... More
S&F in replacement of power contractor MNX12 coil voltage 240 3 pole complete all as specified and directed Make :- L&T/ABB/Siemens/C&S.

10

-

-

... More
S&F in replacement of power contractor MNX32 coil voltage 240 3 pole complete all as specified and directed Make :- L&T/ABB/Siemens/C&S.

6

-

-

... More
S&F in replacement of power contractor MNX18/MNX25 coil voltage 240 3 pole complete all as specified and directed Make :- L&T/ABB/Siemens/C&S.

10

-

-

... More
Supply and fixing in replacement of PVC sheathed copper cable of size 10 Sqmm 5 core, superior quality, laying over GI slotted cable tray including necessary supports and frame work compelte all as specified and directed. Make- Havells/ Polycab/Finolex.

80

-

-

... More
Supply and fixing in Replacement of PVC insulated and PVC sheathed round heavy duty multi strained copper conductor 1100 Volt grade conforming to IS-694 and cross sectional area 4 Sqmm 3 Core fixed on wall by saddles. Make- Havells/ Polycab/Finolex.

60

-

-

... More
Supply and fixing in Replacement of PVC insulated and PVC sheathed round heavy duty multi strained copper conductor 1100 Volt grade conforming to IS-694 and cross sectional area 2.5 Sqmm 3 Core fixed on wall by saddles. Make- Havells/ Polycab/Finolex.

70

-

-

... More
Supply fix in repair control wiring with copper conductor size 1.0 Sqmm , single core all as specified and directed by Engineer in Charge.

10

-

-

... More
S & F in replacement of Pressure control HP cut out switch with air cooled Package AC upto 16.5 TR Make - Danfoss/Indfos or equivalent as approved by GE

10

-

-

... More
S & F in replacement of Pressure control LP cut out switch with air cooled Package AC upto 16.5 TR Make - Danfoss/Indfos or equivalent as approved by GE

10

-

-

... More
S& F auxillary contactor 1NC+1NC, 2NC+2NO of approved make

15

-

-

... More
Supply and fixing in Replacement of MCB,3 Pole 63 Amps, TPN and breaking capacitry 10 KA complete as directed. Make: Legrand/Seimens/ L&T

10

-

-

... More
Supply and fixing in Replacement of MCB,3 Pole 32 Amps, TPN and breaking capacitry 10 KA complete as directed. Make: Legrand/Seimens/ L&T

10

-

-

... More
Supply and fixing in Replacement of MCB,3 Pole 25 Amps, TPN and breaking capacitry 10 KA complete as directed. Make: Legrand/Seimens/ L&T

10

-

-

... More
S&F New Out door unit suitable for 5.5 TR with COOPER CONDENSER COIL of the make as per OEM all as directed by Engineer in Charge.

16

-

-

... More
S&F water drain out pipe 20mm bore with and including fittings and fixture such as L-BOW,SOCKET,REDUCER all as specified and directed by Engineer in Charge.

20

-

-

... More
S&F water drain out pipe 25mm bore with and including fittings and fixture such as L-BOW,SOCKET,REDUCER all as specified and directed by Engineer in Charge.

20

-

-

... More
S&F water drain out pipe 40mm bore with and including fittings and fixture such as L-BOW,SOCKET,REDUCER all as specified and directed by Engineer in Charge.

20

-

-

... More
Supply and fixing in replacement of moulded case circuit breaker 63 Amps,TP, 16 KA, 415 volts 50 Hz including necessary connection for incoming/outgoing with lugs of suitable size complete all as specified and directed Make: L&T/Legrand/CG/C&S/Schneider/Havells

4

-

-

... More
All as per item No 29 above but of 100 Amps TP 16 KA, 415 V, 50 Hz.

4

-

-

... More
All as per item No 29 above but of 200 Amps TP 36 KA, 415 V, 50 Hz

4

-

-

... More
S & F in replacement of copper pipe of size 5/8" complete all as specified and directed.

150

-

-

... More
S & F in replacement of copper pipe of size 7/8" complete all as specified and directed.

150

-

-

... More
S&F COPPER L-BOW 5/8

50

-

-

... More
S&F COPPER SOCKET 5/8

50

-

-

... More
S&F COPPER REDUCER 5/8 *1/2

25

-

-

... More
S&F COPPER L-BOW 7/8

50

-

-

... More
S&F COPPER SOCKET 7/8

50

-

-

... More
S&F COPPER REDUCER 7/8* 5/8

25

-

-

... More
M & L for dismantling old UNSV compressor & supply, installation, testing & commissioning of hermetically sealed scroll type compressor 3 ph 415 V 50 Hz of capacity not less than 5.5 TR & connecting suction, discharge line by jointing with copper rod & oxygen flame and making electric connections & wiring with microprocessor control panel & sensor complete all as specified and directed. Note: (i) The cost of any other sensing/protective device Eqpt required to make the plant functional related to compressor shall be included in quoted rates. (ii) The cost of hiring of technician from the OEM of compressor for installation & commissioning shall be included in quoted rate.

15

-

-

... More
S & F in replacement of Belt V 49 suitable for package AC blower Make:- Fenner/TATA/Dunlop.

10

-

-

... More
Supply and fixing in Replacement PLC (microprocessor controller unit with display suitable for 11 TR (5.5 TR* 2 Compressor) ) suitable for package AC of make Blue star/Voltas having following features or any other control required to make system functional and safe. (i) Run time equalisation. (ii) Auto start after power failure. (iii) Memory back up (iv) Built in time delay (v) Single phasing and auto phase squence corrector (vi) Self fault diagnostics (vii) Easy look up with fire alarm System

6

-

-

... More
Supply and fixing in Replacement PLC (microprocessor controller unit with display suitable for 16 TR Compressor ) suitable for package AC of make Blue star/Voltas having following features or any other control required to make system functional and safe. (i) Run time equalisation. (ii) Auto start after power failure. (iii) Memory back up (iv) Built in time delay (v) Single phasing and auto phase squence corrector (vi) Self fault diagnostics (vii) Easy look up with fire alarm System

2

-

-

... More
Supply only Nitrogen gas complete all as specified and directed by Engr-in-charge.

100

-

-

... More
M&L for detecting leakage from the close circuit of package type AC unit of capacity upto 16.5 TR, rectifying the leakage by breezing of copper rod & oxygen flame, vaccuming the system after rectification of leakage, charging nitrozen and holding the pressure not less than 24 hrs or as specified and directed by Engr-in-charge.

25

-

-

... More
S&F insulation pipe of size 5/8,7/8 complete all as specified and directed by Engr-in-charge.

100

-

-

... More
S&F insulation pipe of size 1/2,3/8 complete all as specified and directed by Engr-in-charge.

100

-

-

... More
S&F insulation pipe 1 inch/ 1.5 inch complete all as specified and directed by Engr-in-charge.

50

-

-

... More
M&L for de-scaling of condenser of various Pacakage AC plant of cap upto 11 TR complete all as specified and as directed :- (i) Opening Block of condenser Inlet and Outlet water pipe. (ii) De-scaling of condenser tubes with de-scaling solution mixed with water by pump method for a duration of 08 hours continuous circulation. (iii) Opening of bolts side condenser cover for following work. (iv) Cleaning of condenser copper tubes carefully with condenser cleaning brushes to the entire satisfaction of Engineer-in-Charge. (v) Removing of rubber gasket of both side covers, preparing, new rubber gasket 6 mm thick, fixing properly with existing bolts/nuts/washers Note :- Cost of descaling solution is deemed to be included in quoted rates. Descling of water cooled condenser capacity 16.5TR by chemical solution with use of long brush in proper manner without leakage

5

-

-

... More
M&L for Descling of water cooled condenser capacity 16.5TR by chemical solution with use of long brush in proper manner without leakage complete all as specified and as directed :- (i) Opening Block of condenser Inlet and Outlet water pipe. (ii) De-scaling of condenser tubes with de-scaling solution mixed with water by pump method for a duration of 08 hours continuous circulation. (iii) Opening of bolts side condenser cover for following work. (iv) Cleaning of condenser copper tubes carefully with condenser cleaning brushes to the entire satisfaction of Engineer-in-Charge. (v) Removing of rubber gasket of both side covers, preparing, new rubber gasket 6 mm thick, fixing properly with existing bolts/nuts/washers Note :- Cost of descaling solution is deemed to be included in quoted rates.

3

-

-

... More
M & L for cleaning of cooling tower and FRP by chemical solution complete all as specified and directed by Engr-in-charge.

1

-

-

... More
S&F sprinkler assembly suitable for 16.5 TR complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Taking out burnt / defective CT fan motor of capacity 2 to 3 HP and re-winding with super eanmelded copper wire, refixing in existing package unit complete testing and commissioning all as directed. Make of copper wire as approved by GE.

1

-

-

... More
Taking out burnt / defective condenser mono block pump motor 10 to 15 HP suitable for package unit of capacity upto 16.5 TR and re-winding with super eanmelded copper wire, refixing in existing package unit complete testing and commissioning all as directed. Make of copper wire as approved by GE.

1

-

-

... More
M&L for refrigerant gas R-22 in package type AC in cylinder of capacity 61 KG after detection and rectification of leakage.Empty cylinders shall be returned to the contractor only after complete consumption of gas without any extra cost to the Department complete as specified and directed by Engr-in-charge.Make:- Mafron/freon/Refron

15

-

-

... More
All as per item no. 55 above but of refrigerant gas R-410 in cylinder Capacity of each cylinder shall be 40 Kg all as directed by Engineer in Charge.

5

-

-

... More
All as per item no. 55 above but of refrigerant gas R-407C in cylinder Capacity of each cylinder shall be 61 Kg all as directed by Engineer in Charge.

5

-

-

... More
Supply, laying, testing and commissioning in replacement of M S Pipes heavy grade of size 50mm with complete fittings such as bends, tees, elbows, reducers, flanges, special fiittings, suspension hangers, etc., as required Make : TATA/ Jindal/ Prakash/ Zenith

24

-

-

... More
S & F in replacement of galvanised steel tubes medium grade of size 25mm including all fittings and testing complete. Make - Tata / Jindal /QST/Surya

40

-

-

... More
Supply and Fix Butterfly Valve of 50 mm dia, Cast Iron body, Wafer type integrally moulded close end body construction with Hand lever operated and rating of PN-10 with thermal insulation as per requirment of chilled water line. Make :- Advance/ Castle/ Intervalve/ SAAPL

6

-

-

... More
All as described in serial item No. 60 above, but of size 100 mm dia

1

-

-

... More
S & F in replacement of Over load thermal relay 12 to 23 Amp suitable for package AC of capacity upto 16.5 TR complete all as specified and directed.

4

-

-

... More
S&F in replacement of single phase preventer VSP 2 complete all as specified and directed. Make:- Minilec/L&T or equivalent as approved by the accepting officer.

4

-

-

... More
S&F blower moter 3 TO 5 HP complete all as specified and directed.

2

-

-

... More
S&F PVC filling complete all as specified and directed.

15

-

-

... More
S & F in replacement of Evaporative blower fan blade of indoor unit suitable for package AC of capacity 11 TR

6

-

-

... More
S & F in replacement of propeller type Condenser fan blade suitable for outdoor unit of capacity upto 16.5 TR as per sample.

5

-

-

... More
S & F in replacement of stainless steel fan guard grill for Condenser fan suitable for out door unit of capacity upto 16.5 TR as per sample.

5

-

-

... More
S & F in replacement of running capacitor 6 MFD, 240 Volt. Make :ASIAN/ELLYT/EPCOS/HAVELLS

10

-

-

... More
S & F in replacement of running capacitor 10 MFD, 240 Volt. Make :ASIAN/ELLYT/EPCOS/HAVELLS

10

-

-

... More
S & F in replacement of Non- woven polyester media enclosed by HDPE mesh type Air filter suitable for package AC upto 16.5 TR of blue Star/Voltas Make - Cecon / Thermodyne or equivalent as approved by GE

5

-

-

... More
S&F in replacement of cable connection connector suitable for current capacity upto 200 Amps Blue star/ voltas package AC unit complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&F in replacement of Timer 5-30 seconds Make:- GIC/L&T or euivalent as approved by the accepting officer.

4

-

-

... More
S&F in replacement of On/Off Push switches

20

-

-

... More
S&F in replacement of RYB LED type indicator lamp

20

-

-

... More
S & F in replacement of pressure guage type 1-32 size 100 mm dia thread 3/8" surface mounting of range upto 150 PSI.

5

-

-

... More
S & F in replacement of siphon (as per sample) in existing line including cutting and welding of new socket/adopter complete all as specified and as directed. Note:- cost of new socket and welding work and making good to existing pipe is deemed to be included in unit rate quoted.

5

-

-

... More
Taking out unserviceable compressor by disconnecting all cable connection and charging/discharge copper lineing with Supply, installation testing highelly efficient hermatecally sealed unit scroll compressor,inverter type 3-phase 4-wire system( 380–415 V, 50 Hz)shall be working on 48 degree centigrate ambient tempreture and based on the indoor temperature 27degree temp DB,19 degree temp W.B with outdoor temp 35 degree centigrade DB,Refrigerent R-410A of compresser suitable highly integreted VRVX genrated on air cooled 46 HP (16 HPX2+14HPx1) or 60 HP (20HPx3) nos of capcitor only one up to 30 HP,VRV air conditioning system Make Daikin/Mitsubishi/Toshiba/Blue Star all as specified and directed by Engr-in Charge.

1

-

-

... More
Supply and replacement to invertor type PCB complete to working on refrigerent cooled condition of VRV system airconditioning plant of capacity suitable up to 60 HP compressor all as specified and directed

1

-

-

... More
Supply and replacement of PCB controller suitable to VRV system aircooled plant of capacity suitable up to 60 HP compressor all as specified and directed

1

-

-

... More
Supply and replacement to PCB Hoise filter complete set suitable for 40HP/ 60 HP VRV system air conditioner compressor all as specified and directed

1

-

-

... More
Supply and replacement to PCB Fan on extsting base with all electrical connection suitable up to 46 HP(16HPx2+14HPx1) or 60HP(20HPx3) VRV system airconditioner of Blue star make all as specified and directed

1

-

-

... More
Supply and replacement to outdoor fan moter suitable up to 20 HP of highly integrated VRV generating airconditioning system of make suitable for blue star all as specified and directed

1

-

-

... More
Supply and replacement to Casette type indoor unit PCB suitable for(46HPx2+14HPx1) or 60 HP (20HPx3)VRV system airconditioning of make blue star all as specified and directed

1

-

-

... More
Supply and replacement indoor unit Fan moter suitable up to sensing flow cassette type(2.08TR to 4.63 TR+corded remote + refnet) VRV system airconditioning of existing blue star make plant all as specified and directed

1

-

-

... More
Supply and replacement to old crached existing copper tube 9/8" dia with all brazing and soldering work including cutting flaring and testing and make lekage proof all as specified and directed

10

-

-

... More
Supply and replacement to old craoted existing copper tube 3/4" to 7/8" dia with all brazing and soldering under including cutting flairing & testing and make lekage proof all as specified and diected

10

-

-

... More
Supply and replacement of over voltage PCB suitable for 46 HP(16HPx2+14HPx1)or 60 HP(20HPx3) VRV system airconditioing of blue star make all as specified and directed

10

-

-

... More
Supply and replacement control wiring of 2 core x 1.5 sqmm copper between indoor units and their wired remote all as directed by Engineer in Charge.

50

-

-

... More
Supply and replacement laying of MS slotted angle for pipes and cables horizontally and vertically along with threaded rod,nut,bolt,saddle,tie etc. all as directed by Engineer in Charge.

50

-

-

... More
S & F single pole and neutral enclouser with a two pin and earth plug and socket complete with single pole MCB 32 Amps fixed properly on in connected position all as directed by Engr-in-Charge

2

-

-

... More
Supply and replacement PVC insulated & PVC sheathed industrial round multicore flexible cable copper conductor 1100 volts grade Conf o IS 694/2010 with lattest amendenents size 2.5 sqmm 3 core all as specified and directed by Engineer in Charge.

50

-

-

... More
Supply and replacement for out door units (46 HP) 100 Amp,16 KA,415 V TP+NL MCCB with adjustable thermal settings,overload and short circuit relaese including door interlocking device ,front operating handle,ON and OFF indication LED modul,bus bar extension for connecting cables etc complete in all respects all as specified and directed

1

-

-

... More
Supply and replacement for out door units (60 HP) 125 Amp,16 KA,415 V TP+NL MCCB with adjustable thermal settings,overload and short circuit relaese including door interlocking device ,front operating handle,ON and OFF indication LED modul,bus bar extension for connecting cables etc complete in all respects all as specified and directed

1

-

-

... More
Supply and replacement for indoor units 63 Amp,16 KA,415 V TP+NL MCCB with adjustable thermal settings,overload and short circuit relaese including door interlocking device ,front operating handle,ON and OFF indication LED modul,bus bar extension for connecting cables etc complete in all respects all as specified and directed

1

-

-

... More
Supply and replacement for indoor units 40 Amp,16 KA,415 V TP+NL MCCB with adjustable thermal settings,overload and short circuit relaese including door interlocking device ,front operating handle,ON and OFF indication LED modul,bus bar extension for connecting cables etc complete in all respects all as specified and directed

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.