Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Oct 2024
Closing Date2 Nov 2024
Tender Amount₹ 38,59,000
Costs
EMD
₹ 77,180Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678191_1Bid Award Id
ViewTender No
8774/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Spl repair of bathroom and toilet of certain bldgs. at Old Cantt Prayagraj.
BOQ Items
All as per item No. 03 above but Except Bricks.
3
-
-
Demolition of cement/ lime conrete in roofs any thickness and in any position and leaping over roof terrace, removing the demolished material to a distance exceeding 50m & not exceeding 250m and depositing where directed at a level not exceeding 1.5 m above starting point, complete all as specified and as directed.
8
-
-
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof padding (levelling course), n'exc 25mm average thickness, finishing the surface fair & even complete all as specified and directed.
120
-
-
M&L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges all around periphery of the wall complete all as specified and directed.
1
-
-
M&L for applying high performance polyurethane liquid membrane waterproofing coating on roof in two layer complete as per manufacturer's instructions complete all as specified and directed. The treatment shall be carried out in following steps:-
(i) Step 1: clean the roof surface thoroughly to make it free of dust, dirt, grease, and other debris.
(ii) Step 2 : Fix the cracks on the surface bed by cutting it into the V section, followed by cleaning and filling with polyurethane-based crack filling compound and white cement in the ratio of 1: 2.
(iii) Step 3 : Substrate should be neutralized using the acid application to remove the alkalinity.
(iv) Step 4 : All joints, corners and RWP openings shall be properly repaired as per manufacturer's instructions. The material recommended by manufacturer shall be used and cost of same shall deemed included in quoted rates.
(iv) Step 5 : Apply a pack of polyurethane primer coat to the surface as an adhesive coat, and allow to dry completely for at least 8 hours.
(v) Step 6 : Two successive finishing coats with polyurethane liquid membrane must be applied by brush/roller/spray. Each coating must be dried for at least 12 hours before applying the subsequent coating. After Geotextile fabric of 40 GSM to be applied over first coat while first coat is still wet . This PU coating has to be continued 150 mm up the parapets or walls and at least 100 mm into the rainwater pipes.
(vi) The final polyurethane coating is sprinkled with a layer of 300 microns of sand.
130
-
-
NOTE:
(a) The contractor shall submit a guarantee of 10 years from the date of completion of work for waterproofing treatment along with manufacturer's guarantee. The amount @ Rs. 40 (Forty) per Sqm and subject to min of Rs. 4000/- shall be retained from final bill till the expiry of guarantee period. The contractor at his own option may furnish fix deposit receipt in lieu duly plaged in favour of GE (East) Prayagraj.
(b) The water proofing shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved in writing from GE within 30 days since commencement of work.
(c) Liquid membrane @ 1.5 Kg/Sqm/ 2 coats and epoxy primer @ 0.15Kg/Sqm shall be applied. The liquid membrane shall strictly as per relevant IS code/BIS code.
(d) Each stage (preparation of surface, priming, Ist coat and 2nd coat) shall be got approved from GE in writing before execution of successive stage.
(e) Production of Purchase vouchers for full quantity duly defaced by Engg-in-charge is mandatory requirement for release of payment. The same shall be recorded in MB.
-
-
-
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection and tank base, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
60
-
-
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
2.5
-
-
S&F in repair 500 litters capacity white colour double layer, ISI marked, rotational moulded polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces for inlet, outlet, washout, overflow, GI tank nipple and 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe complete all as specified and directed.
6
-
-
All as per item No. 11 above but 1000 litters capacity rotational moulded polythene water storage tank
2
-
-
S&F in repair 20 mm dia Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipes complete all as specified & directed.
8
-
-
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
660
-
-
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4, mixed with liquid water proofing compound @ 200ml/50Kg cement complete all as specified and as directed.
NOTE: Liquid water proofing compound shall be measured and paid separately under respective item here-in-under.
360
-
-
Supply only Liquid water proofing compound complete all as specified and as directed.
30
-
-
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) complete all as specified and as directed.
240
-
-
M&L for rendering 5 mm thick on concrete surface in ceiling in CM 1:3 complete all as specified and as directed.
60
-
-
M&L for preparation of old painted surface by complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) using 80grade sanding pad and make the surface free from dust, loose paint etc complete all as specified and as directed.
1100
-
-
M&L for applying waterproof cement based putty @ 1 Kg (undiluted) per sqm over prepared surface of wall and sanding of the putty surface with mechanical wall sander using sanding pad of 240 Grit or above to make the surface even and smooth complete and make it free from dust etc. complete all as specified and directed.
900
-
-
M&L for one coat of acrylic water based interior /exterior grade primer @ 0.9 ltr (undiluted)/10 sq mtrs mixed with water in 1:1 ratio complete all as specified and directed.
1140
-
-
M&L for two coats of water based premium acrylic smooth exterior emulsion paint of approved colour using Airless spray technology (Spray mechine) complete all as specified and as directed.
900
-
-
M&L for two coats of Oil bound distemper paint using Airless spray technology (Spray mechine) complete all as specified and directed.
240
-
-
NOTES FOR SMART PERIODICAL UNDER ITEM NO. 19 TO 23 ABOVE: a) The paint shall have silicon additive & Color stay Technology, Excellent Dirt Pick up resistance, anti algal properties and low VOC (less than 50 gram/ litre) as per the LEEDS specifications, (b) Consumption of paint shall not be less than 1.79 Kg/10Sqm for two coats where as for primer it shall not be less than 0.90 ltr/10 Sqm for one coat. (a.) The smart periodical services shall be got executed through authorized applicator of manufacturer whom painting materials is proposed to use. The approval of GE in writing for name of applicator and MOU with him is mandatory requirement. before execution of work. (c) Production of Purchase vouchers for full quantity duly defaced by Engg-in-charge is mandatory requirement for release of payment. The same shall be recorded in MB. (d) No material brought st site shall be allowed to incorporate in the work without approval of GE in writing.
(e) All painting work i.e removal of existing treatment, application of putty, primer and paint, sanding putty surface etc shall be done through grinding or spray machine of appropriate capacity and specifications.
-
-
-
M&L for applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
60
-
-
M&L for applying two coat of white wash on old decorated plastered on ceiling including preparation of surfaces complete all as specified and directed.
150
-
-
M&L for applying two coat of white wash on old decorated plastered on ceiling including preparation of surfaces complete all as specified and directed.
Note for tem No. 26 & 27: Preparing old decorated plastered surfaces include brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots.
40
-
-
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
97
-
-
M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in vertical surface, skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:4 Complete all as specified and directed.
230
-
-
M&L for Coloured Glazed ceramic tiles in vertical surface 450mm X 300mm X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick plaster in cement mortar (1:4) complete all as specified and directed.
740
-
-
M&L for sunken portion treatment in following steps and procedure given below:-
(a) Taking out complete filling from shuken portion including demolition of existing floor and underneath layers of any thickness and description compete.
(a) Making provision of drainage spout using 40mm dia bore light grade GI pipe up to outside of outer wall (Approx 450mm to 600mm long) including making hole in wall and sealed properly after putting spout pipe with rich cement mortar mixed with sealant compound.
(b) Clean the sunken surfaces (bottom and sides) thoroughly to make it free of dust, dirt, grease, and other debris. (c) Provide 50mm thick PCC 1:1.5:3 type A-0 (using 12.5mm graded stone agg) mixed with waterproofing chemical as per manufacturer instructions , laid in slope towards spout pipe. (d) 15mm thick cement plaster on vertical faces in CM 1:3 mixed with water proofing chemical. (e) Applying two coats of polyurethane liquid membrane waterproofing coating on vertical as well as horizontal surface.
(f) Drainage and water supply pipe shall test for leakage properly. If any leakage is observed the same shall be blocked/sealed properly before loose filling in sunken portion.
80
-
-
Contd/...
(g) Pond test for sunken portion shall carried out before filling singhals and test report duly signed by Enng-in-charge shall be kept in record. This stage shall be passed in writing by GE.
h) Provide 20mm singhals aggregate as filter media, 150mm thick and than PCC1:5:10 type E-2 (using 0mm graded stone aggregate) of required thickness as sub base for floor
(j) Provide 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm grade stone aggregate) as base for receiving floor finish.
(k) Provision of non skid ceramic coloured joint less tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exc 0.11 Sqm but n'exc 0.18sqm as in floors etc; over and including 15mm thick screed bed in CM (1.6), laid, jointing in neat cement slurry and pointed/filled with epoxy chemical mixed with pigment to match the shade of tiles complete all as specified and directed.
NOTE : (i) Chemical in various applications shall be shall be used as per manufacturer instructions.
(ii) Carpet area shall be measured for payment purpose.
-
-
-
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
15
-
-
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
40
-
-
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
120
-
-
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
50
-
-
S&F 110mm PVC (SWR) bends any radius with access door complete all as specified and as directed.
5
-
-
S&F 110mm PVC (SWR) bends any radius complete all as specified and as directed.
15
-
-
S&F 75mm PVC (SWR) bends any radius complete all as specified and as directed.
4
-
-
S&F 75mm PVC (SWR) bends any radius with access door complete all as specified and as directed.
6
-
-
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
10
-
-
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
4
-
-
S&F 110mm PVC (SWR) branch pieces single (Single Y) equal or unequal complete all as specified and directed.
4
-
-
S&F 110mm PVC (SWR) vent cowl complete all as specified and as directed.
4
-
-
S&F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and as directed.
48
-
-
S&F Stack clamps made out of 50mm x 5mm flat iron & 16mm round iron stays including bolts & nuts (not less than 8mm dia and 75mm long) and securing ends of stays suitable for 75mm/100mm bore pipe complete all as specified and as directed.
42
-
-
S&F in repair 150mmx 100mm Salt-glazed stoneware gully traps, square or round mouthed, type 'P' or 'S' and setting and jointing in cement mortar 1:1 complete all as specified and directed.
25
-
-
M&L for Cutting chases pinning in brick walls, making good to facing where required and pointing in CM 1:3 to ends or edges of landing , steps, cills, sunshades, shelves lintels etc. and cutting chases for concealed for water tubing or concealed conduit wiring etc and making good, cutting n.exc 10cm girth complete all as specified & directed.
90
-
-
Taking up or down steel tubing and connection including cleaning for refixing or removal to store 15mm bore pipe complete all as specified & directed.
110
-
-
S&F GI tubes 15mm bore medium grade with all fittings fixed to walls and ceilings or laid in floor complete all as specified & directed
110
-
-
Taking up or down steel tubing and connection including cleaning for refixing or removal to store 20mm bore pipe complete all as specified & directed.
50
-
-
S&F 20mm bore GI tubing medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors complete all as specified and directed.
50
-
-
Taking up or down steel tubing and connection including cleaning for refixing or removal to store 25 mm bore pipe complete all as specified & directed.
15
-
-
M&L for 25 mm bore GI tubing medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
15
-
-
S&F in repair 15 mm dia bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified & directed.
30
-
-
S&F in repair 15 mm dia angular cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified & directed.
84
-
-
S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden/PVC plugs with chromium plated brass screws and cup washers complete all as specified & directed.
20
-
-
S&F in repair Vitreous china wash down water closet pedestal pan white, closed pattern with recessed bottom including plastic water closet seat cover with mild steel chromium plated or aluminium hanging device, complete all as specified and as directed.
20
-
-
S&F PVC valve less, symphonic action type, flushing cistern 10 litres capacity, low level, white, with inlet ball valve float handle along with suitable flush pipe/bend including brackets, complete all as specified & directed.
20
-
-
S&F in repair brass chromium plated 2 way bib cock with wall flange 15 mm dia screwed down, screwed for iron pipes complete all as specified and directed.
20
-
-
S&F in repair Health faucet with ABS body with 8 mm dia 1.00 m long flexible tube and wall hook complete all as specified and directed.
20
-
-
S&F in repair 60cm long sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf, 12cm wide with chromium plated bracket guard and railing complete all as specified and directed.
20
-
-
S&F in repair Corner glass shelf (set of three ) of approved make and model similar to sample kept in GE's office, with brass chromium plated bracket, fixed to wall complete all as specified and directed.
16
-
-
S&F in repair vitreous china wash hand basin (WHB), white, flat back of size 550 x 400 mm excluding taps, waste chain and plug but including bracket, waste coupling of 32 mm size complete all as specified and directed.
20
-
-
S&F in repair 15 mm bore brass chromium plated central hole basin mixer (without popup) for mixing hot & cold water and fixed complete all as specified and directed.
20
-
-
S&F in repair 15 mm bore brass chromium plated wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
20
-
-
S&F in repair Brass chromium plated shower rose 125 mm dia with shower arm complete all as specified and directed.
20
-
-
S&F in repair PVC connections, 15mm size with PTMT nuts of length 600mm complete all as specified & directed.
68
-
-
S&F in repair 32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 and fittings, fixed complete to walls, ceilings or in floors etc. complete all as specified & directed.
28
-
-
S&F in repair brass chromium plated Tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as specified and directed.
20
-
-
S&F in repair brass chromium plated Tumbler holder of approved make and model similar to sample kept in GE's office complete all as specified & directed.
20
-
-
S&F in repair Stainless steel soap dish of approved make and model similar to sample kept in GE's office complete all as specified and directed.
40
-
-
S&F in repair Vitreous China Half stall type urinal including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing, flush pipe, grating and Union for discharge pipe trap and waste pipe and waste coupling complete all as specified & directed.
8
-
-
S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe (Minimum weight 60gms) complete all as specified & directed.
8
-
-
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area not exc 1.5 Sqm each complete all as specified & directed
50
-
-
Taking down shutters of any description n'exc 1 sqm each including removing from site to store or otherwise complete all as specified & directed.
40
-
-
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area exc 1.5 Sqm but n exc 4.00 Sqm each complete all as specified & directed
8
-
-
S&F factory made single extruded WPC (Wood Polymer Composite) solid Frames/ Chowkhat of size 45mm x 70mm for door/ window/ ventilators, comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete all as specified & directed
230
-
-
Factory made Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & given on page No. 179 of SSR Part-II-2020 under section 8, complete all as specified and directed.
70
-
-
S&F 150mm Aluminium handles, cast type, anodised of pattern/design as approved by GE/sample kept in GE's office complete all as specified and directed.
100
-
-
S&F 200mm (bolt length) Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
100
-
-
S&F 100 mm long butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed.
168
-
-
S&F 250mm (bolt length) Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
8
-
-
Supply, febrication and fixing in position aluminium frame (chawkat) for door/window/ventilator using appropriate colored powder coated aluminium sections (as approved by Enng-in-charge) having 50 micron (mini) powder coating thickness with one or more rebates joining cleat for fixing etc complete all as specified including concealed type lock for all three shutters complete all as specified & directed.
110
-
-
Supply, febrication and fixing in position aluminium window and ventilator shutters, side hung type without sash bars, using appropriate colored powder coated aluminium sections (as approved by Enng-in-charge) having 50 micron (mini) powder coating thickness and weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings for each leaf such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified & directed.
30
-
-
S&F 4.8 mm thick frosted sheet glass ordinary quality and glazing with beading not exceeding 0.5 sqm in each pane complete all as specified and directed.
24
-
-
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
205
-
-
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
10
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out complete all as specified and directed.
110
-
-
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches 150mm bore of pipe complete all as specified & directed.
60
-
-
All as per item No. 89 above, but 200mm bore pipe.
60
-
-
Supply, laying, jointing and testing Double wall corrugated (DWC) HDPE(PE) Pipe, stiffness classes SN-8 KN/m²E SN 8, nominal size 163 (ID)/180 (OD) dia, conforming to IS-16098 (Part-2): 2013, in trenches including all items and activities required to make sewer line functional complete all as specified and directed.
60
-
-
All as per item No. 91 above but pipe of dia 175 (ID)/200(OD).
60
-
-
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed.
75
-
-
Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
30
-
-
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed.
160
-
-
M&L for point wiring for one light point/ fan point with 1.5 sq.mm FRLS PVC sheathed/insulated multi stranded 1100 volts grade copper conductor cable in PVC conduit complete all as specified and directed.
NOTE:-
(i) PVC conduit shall be of 20mm dia (min), medium class and with it's all accessories.
(ii) Terminal box suitable for modular switch/sockets of appropriate modules. Shall sunken type with made of pressed 1.2mm thick MS sheet and painted with one coat of red oxide primer. (iii) Bakelite plastic laminated sheet cover for fixing switches/ socket/regulators etc shall be 3.0 mm thick ISI marked
(iv) Proper colour code shall be followed for Phase, earth and neutral wire.
(v) Cutting chases in wall (in case of concealed or resseced type point wiring), if required, shall be measured and paid separately under respective item here-in-after. (vi) Point wiring shall strictly as per relevant code.
128
-
-
All as per item No 96 above but with 2.5 sqmm cable for one 5/6 or 15/16 Amp socket outlet point on independent board .
24
-
-
All as per item No 96 above but with 4.0 sqmm cable for one 15/16 Amp socket outlet point independently (for Geyser & AC) controlled by one earth plug and socket box in lieu of sunken box, moduler plate and cover.(Except sunken box, moduler plate and cover) Note: Earth plug and socket box shall be measured and paid seperatly.
8
-
-
S&F Switch Piano Flush button single pole one way 5 Amp complete all as specified & directed.
144
-
-
S&F socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified & directed.
16
-
-
S&F switch piano flush single pole one way 15/16 Amps complete all as specified & directed.
16
-
-
S&F socket outlet flush type 5/6 pin 15/16 Amps 230V AC complete all as specified & directed.
16
-
-
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified & directed.
80
-
-
S&F Lamp holder PVC/Polycarbonate type with back plate with 9w LED bulb suitable for batten fittings complete all as specified & directed.
48
-
-
S&F LED tube light fittings, 18 watt fixed to wall, complete all as specified and directed.
Make : Havels cat part No. : ENDURALINEARNEOBS20WLED865SPCSS or equivalent of make Bajaj & Philips.
48
-
-
S&F LED Mirror light fitting, 10Watt, 2 feet long including LED lamp and making connection complete all as specified and directed.
16
-
-
S&F sheet metal enclosure/Distribution board for MCBs, double door type, epoxy powder coated, factory made, Single Pole and Neutral (SPN), 8 way 240Volts with 200 Amps rated bus bar, with enclosure blank plates for unused way complete all as specified and directed.
8
-
-
S&F MCB SP, 6-32 Amps, 240V, 10KA, 'B' curve complete all as specified and directed.
32
-
-
S&F MCB SPN, 32 Amps, 240V, 10KA, 'B' curve complete all as specified and directed.
8
-
-
S&F in repair new exhaust fan heavy duty, steel body with steel blads, 250mm sweep, single phase 240 volt including making electrical connection and writing MES No with black paint complete all as specified and directed.
NOTE: Existing exhaust fans shall be deposited by the contractor in AGE E/M old cantt yard
16
-
-
S&F electric water heater, storage type steel body and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC connection (02 nos) etc. complete all as specified & directed.
NOTE: Existing exhaust fans shall be deposited by the contractor in AGE E/M old cantt yard
8
-
-
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run as continuous earth wire of similar description, drawn in and including 20mm dia 'medium grade' PVC concealed conduits (with fittings), complete all as specified and directed.
NOTE: Two run of main wire and one run of earth wire with conduit shall measured as One unit length.