If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 39,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.

1.56

-

-

... More
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 to 120 Sqmm 3 core complete all as specified and directed.

400

-

-

... More
M&L in replacment laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with aluminium conductor of cross sectional area 95 Sqmm 3 core 11 kV rated suitable for earthed system including testing and commissioning complete all as specified and directed. Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.

200

-

-

... More
All as per item No 6 above but HT 11 kV cable of size 120 Sqmm complete all as specified and directed.

200

-

-

... More
M&L in replacment laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core including taking out old unsv cable of any type, make & capacity complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)

875

-

-

... More
All as above item No 8 above but of size 120 Sqmm 3.5 core complete all as specified and directed.

518

-

-

... More
Supply and fixing of HDPE Double wall corrugated (DWC) electric pipes of size 75/61 mm dia manufactured using HDPE polymer having a smooth internal surface & currugated external surface having with greater stiffness withstand soil movement & take higher loads (static & dynamic) including connecting rings made of HDPE DWC suitable for 75/61 mm pipes, to pass through 95 to 120 sqmm HT/ LT complete all as specified and directed.

1613.7

-

-

... More
Supply and fix in replacement of cable straight through jointing kit for 11 kV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

6

-

-

... More
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

8

-

-

... More
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and directed.

10

-

-

... More
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed.

1.5

-

-

... More
Boring of holes under road, pavement hard standing manually incl HDPE pipe of 80 mm dia suitable complete all as specified and directed.

20

-

-

... More
M&L for pre cast cement concrete (1:2:4) type C2 (using 40mm graded stone aggregate) for foundation filling of stays complete all as specified and directed.

1

-

-

... More
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside complete all as specified and directed.

4

-

-

... More
Supply, errecting and installation of steel tubular swaged pole type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint with cast iron base plate, finial taper plug, bolts, nuts & screws as specified and marking pole number with black paint complete all as specified and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)

4

-

-

... More
S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 6 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed.

50

-

-

... More
Disconnecting electrically, dismantling from foundation with due care and setting aside HT feeder pillar box any type any size with all accessories complete all as specified and directed.

1

-

-

... More
S&F in replecement HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron of size 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed.

2

-

-

... More
M&L for replacement of GI tubing light grade of size 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately).

20

-

-

... More
S&F in replacement of in position retro reflective sign board size not less than 2.5 ft x 2 ft, cut to sizes/shape made out of 3 mm thick high density aluminium sheet fixed on wall with aluminium frame work with all weather effected duly riveted with vinyale sheet based of blue colour base by hot process including letter/number fitted on wall with proper arrangement complete all as specified and directed. Note : The subject matter, font, size & colour is to be decided by Engr-in-charge.

12

-

-

... More
M&L for Insulating mats made of Elastomer for use as floor covering for the protection of workers on AC high tension installations with the system voltages up to 11 kV AC and 240 V DC and as per IS:15652 latest in size of 2000X1000mm, class B type, thickness not more than 2.5mm of sheet blue/black in colour complete all as specified and directed.

5

-

-

... More
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not exceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M complete all as specified and directed. Note - (1) Tools including Cutting, Digging, grass/ bush cutting machine including fuel & oil has to be provided by contractor with mechine operator & labour.

4000

-

-

... More
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable complete all as specified and directed.

10

-

-

... More
Detection of any type of fault in LT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering LT cable of size 50 Sqmm 3.5/ 4 core and above complete all as specified and directed. Note for (Item No 26&27): 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.

10

-

-

... More
M&L for Earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level connected to GI strip 25 x 4mm thick as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 32mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.

6

-

-

... More
M&L for Earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level connected to GI strip 32 x 6mm thick as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.

6

-

-

... More
M&L for fixing earthing strip 32 x 6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.

80

-

-

... More
Taking down carefully transformer of any make, any type or capacity from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site and shifting/refixing at other location under GE (I) Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.

5

-

-

... More
Transportation of Transformer from site/ E/M yard to workshop for repairing and from workshop to site /E/M yard after repair etc of capacity upto 250 kVA complete all as specified and directed.

7

-

-

... More
All as per item No 32 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

2

-

-

... More
All as per item No 32 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

2

-

-

... More
Dismantlling top cover of transformer of capacity upto 250 kVA , any make for repair / replacement of HT/LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required/upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note - spare parts will be measured and paid separately under respective items.

4

-

-

... More
All as per item No 35 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

5

-

-

... More
All as per item No 35 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

2

-

-

... More
Material and labour for dismantling of complete HV/LV coils of transformer upto 250 kVA (11/6.6/0.433 kV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV/LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note : (i) Rewinding of defective HV/LV Coils shall be measured and paid separately. (ii) The rate deemed to be included of all tools and plants.

4

-

-

... More
All as per item No 38 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

5

-

-

... More
All as per item No 38 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

2

-

-

... More
Dismantling old un-serviceable HT 11 kV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 kVA complete all as specified and directed.

6

-

-

... More
All as per item No 41 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

9

-

-

... More
All as per item No 41 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

6

-

-

... More
Dismantling old un-serviceable LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 kVA complete all as specified and directed.

6

-

-

... More
All as per item No 44 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

12

-

-

... More
All as per item No 44 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

8

-

-

... More
Repairs to the leaks of transformer of any cap from tap switch/ fins/ any pats of body, by replacing gasket / seal, or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.

12

-

-

... More
M&L for taking out old burnt winding and rewinding of HT/LT coil of different type, upto 250 kVA capacity and any make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site complete all as specified and directed.

250

-

-

... More
All as per item No 48 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

380

-

-

... More
All as per item No 48 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

445

-

-

... More
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 11/6.6/0.433 kV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed.

8

-

-

... More
Disconnecting electrically, open the cover of transformer any type/size and filtration and dehydration of Transformer oil for 11 / 6.6 / 0.433 kV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 kV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.

7000

-

-

... More
M&L for Open the cover of transformer any type/size on site/ in workshop for rep & maint and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 40 kV when tested at 4mm gap complete all as specified and directed.

2000

-

-

... More
S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 400 kVA complete all as specified and directed.

4

-

-

... More
S&F in replacement of breather assembly with fresh silica gel for transformer of any make and capaciy upto 250 KVA at site complete all as specified and directed.

4

-

-

... More
All as per item No 55 above but exceeding 250 kVA not exceeding 500 kVA complete all as specified and directed.

4

-

-

... More
All as per item No 55 above but exceeding 500 kVA not exceeding 750 kVA complete all as specified and directed.

4

-

-

... More
Servicing / Calibration to 11/6.6 kV HT VCB complete including the following (a) Taking out 11/6.6 kV HT VCB of 630/800/1250 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB trolley including opening the VCB & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where required complete all as directed and specified. (b) Taking out relay set of any make from HT 11/6.6 kV VCB panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately. Note : Minor spares if required shall deems to be included with the above job.

9

-

-

... More
M&L for servicing by disconnecting of all electrical connecton of 11 KV LBS, checking of mechical system for proper functioning of LBS/RMUs, cleaning of moving contact including of filling of gas required at site complete all as specified and directed by Engr-in-Charge. Note : Minor spares & gas re-fill/ topup shall deems to be included with the above job.

10

-

-

... More
M&L for disconnecting electrical for cleaning, rubbing of old paint and re-painting all surfaces of transformer of cap upto 250 KVA complete all as specified and as directed by Engr-in-charge.

4

-

-

... More
All as per item No 60 above but exceeding 250 KVA not exceeding 500 KVA complete all as specified and directed.

4

-

-

... More
All as per item No 60 above but exceeding 500 KVA not exceeding 750 KVA complete all as specified and directed.

4

-

-

... More
Supply & Fixing in replacment shunt trip coil assembly suitable for HT, VCB panel 11/6.6 kV, operating on 30 / 110 volt system and testing complete all as specified and directed.

5

-

-

... More
Supply & Fixing in replacment closing / tripping coil operated on 110 / 30 volt system suitable for working of relay of HT VCB panel complete all as specified and directed.

5

-

-

... More
Supply & Fixing fabricated gears as required for spring charger of VCBs complete all as specified and directed.

2

-

-

... More
S&F in replacment charging motor for 11 kV, VCB, 1250 Amps operated on 230 volts DC complete all as specified and directed.

2

-

-

... More
M&L for the CTs of ration 200/100/5, with 5 P 10 for protection and class-I accuracy having 15 VA burden complete all as specified and directed.

2

-

-

... More
S&F in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed.

12

-

-

... More
M&L for fixing in replacment of Power packs for back up time of VCBs/RMUs 110V DC for suitable working of relays with accessories and including connection with suitable size of copper control cable as required complete all as specified and directed.

5

-

-

... More
M&L for display board with the information of electrical shocks, CPR process & other treatments chart related to electric shock, in size not less that 70X50cm duly frames with good quality fiber hardboard and fixed to walls of substations complete all as specified and directed.

5

-

-

... More
M&L for MS work with hand rails ,half round or other stock section ,drilled and countersunk for balusters running bars,including embeding in concrete and screwing etc , struts in fencing including cutting tops to shape, drilling holes ,notching for wire etc,flat iron fillets (for securing wire mesh/XPM net etc) including all necessary drilling ,bolting or riveting and similar work conforming ton Fe--290 Gde E-165,with two coats synthetic black paint on steel surfaces including dismantling of old detoriated fencing complete all as specified and directed.

120

-

-

... More
M&L for PVC coated chain link fencing with mesh size 50X50 mm, GI wire dia not less than 4 mm and final PVC coated diameter should not less than 5 mm, height not less than 1 mtr from the plateform, colour of mesh will be decided by Engr-in charge and fixed to MS angles complete all as specified and directed.

120

-

-

... More
Supply and fixing in replacment of Vacuum interrupter for VCB HT 11 KV/ 1250 Amps (34599 M3+) complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.