Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only Running capacitor 1.5 MFD ISI Marked of approved make

50

-

-

... More
Supply only Running capacitor 2.5 MFD , ISI Marked of approved make

45

-

-

... More
Supply only Running capacitor 4 MFD ISI Marked of approved make

20

-

-

... More
Supply only Running capacitor 6 MFD ISI Marked of approved make

25

-

-

... More
Supply only Running capacitor 36 MFD ISI Marked of approved make

15

-

-

... More
Supply only Running capacitor 45+6 MFD ISI Marked of approved make

120

-

-

... More
Supply only Running capacitor 50+6 MFD ISI Marked of approved make

90

-

-

... More
Supply only Running capacitor 55+6 MFD ISI Marked of approved make

110

-

-

... More
Supply only starting relay 1.5/2.0 TR/3.5 TR ISI Marked of approved make

10

-

-

... More
Supply only thermostate switch with knob suitable for window AC

15

-

-

... More
Supply only in replacement contactor relay for split/tower AC of capacity up to 3.5 TR AC, 415V, 50Hz, 3 Phase of approved .

10

-

-

... More
M & L for disconnecting of u/s PCB from the unit of split AC/ window AC for repair / replacement of defective parts required to make servicable & reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge.

45

-

-

... More
S & F replacement of MCB SP 240 Volt 32 Amp 10 KA capacity of approved make complete all as specified.

15

-

-

... More
S & F in replacement Metal clad socket industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box of approved make complete all as specified.

45

-

-

... More
S & F in replacement Metal plug top industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box. of approved make complete all as specified.

45

-

-

... More
Supply only (NRV) suitable for window/split Ac of 1.5/2 TR of approved make complete all as specified.

80

-

-

... More
Supply,fixing and replacement of Flare nut 6/8'' all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply,fixing and replacement of Flare nut 5/8'' all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply,fixing and replacement of Flare nut 3/8'' all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply,fixing and replacement of Flare nut 1/2'' all as specified and directed by Engr-in-Charge.

25

-

-

... More
Supply,fixing and replacement of Flare nut 1/4'' all as specified and directed by Engr-in-Charge.

45

-

-

... More
Supply,fixing and replacement of Dead nut 6/8'' all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply,fixing and replacement of Dead nut 5/8'' all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply,fixing and replacement of Dead nut 3/8'' all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply,fixing and replacement of Dead nut 1/2'' all as specified and directed by Engr-in-Charge.

25

-

-

... More
Supply,fixing and replacement of Dead nut 1/4'' all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply,fixing and replacement of suction valve 6/8'' all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply,fixing and replacement of suction valve 5/8'' all as specified and directed by Engr-in-Charge.

45

-

-

... More
Supply,fixing and replacement of suction valve 1/2'' all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply,fixing and replacement of Discharge valve 3/8'' all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply,fixing and replacement of Discharge valve 1/4'' all as specified and directed by Engr-in-Charge.

45

-

-

... More
Supply fix in replacement OLP relay suitable for 1.5 TR/2.00 TR AC of approved make complete all as specified.

10

-

-

... More
Supply only copper liquid line filter 3 way suitable for copper pipe of 3/8 dia for window/ split AC

50

-

-

... More
Supply and fix in replacement Copper pipe 5/8 " outer dia all as specified and directed by Engr-in-Charge.

200

-

-

... More
Supply and fix in replacement Copper pipe 3/8 " outer dia all as specified and directed by Engr-in-Charge.

60

-

-

... More
Supply and fix in replacement only Copper pipe 1/2 " outer dia all as specified and directed by Engr-in-Charge.

60

-

-

... More
Supply and fix in replacement Copper pipe 1/4 " outer dia all as specified and directed by Engr-in-Charge.

200

-

-

... More
S & F in replacement copper pipe insulation of any size complete suitable for split /Tower AC all as specified and directed by Engr-in-Charge.

200

-

-

... More
M&L for dismantaling, disconnecting u/s compressors from Split /window AC of capacity 1.5 TR and replacement with new HSCM compressor (rotary type) on mountings such as rubber pads, nut, bolt, wahers and breezing suction and discharge lines properly, making electrical connections, checking and leakage at joints and vaccuming the system all as specified and directed by Engr-in-Charge. Note: Serial Number of Sealed Compressor shall be entered in MB.Contractor shall submit manifecturer's test certificate of compressor.

40

-

-

... More
All as per item no. 42 here in before but Rotary Compressor for 2.0 TR AC, 220V, Single Phase.

20

-

-

... More
All as per item no. 42 here in before but Reciprocating compressor for 1.5 TR AC 220 V.

5

-

-

... More
All as per item no. 42 here in before but Reciprocative compressor for 2.0 TR AC 220 V.

5

-

-

... More
All as per item no. 42 here in before but Scroll compressor of capacity 3.5 TR AC, 415V,50Hz , Three phase

6

-

-

... More
M & L transportaion of air conditioner from site to work shop for defecting leakage from the close circuit of window air conditioner 1/1.5/2.0 TR capacity, rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.(Note:- Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)

60

-

-

... More
M & L for dismantling of Indoor unit split Air conditioner of capacity 1.5/2 TR transporting from site to workshop for defecting leakage from the close circuit of split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)

150

-

-

... More
M & L for dismantling of outdoor unit Split Air conditioner of capacity 1.5/2.0 TR transporting from site to workshop for defecting leakage from the close circuit of Split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site. ( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)

140

-

-

... More
M & L for defecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)

2

-

-

... More
M & L for charging of refrigerent R-22 in window / split AC of capacity 1/1.5/2.0/3.5 TR capacity after detection and rectification of leakage under relevant items of schedule and testing complete all as specified and directed by Engr-in-Charge.

185

-

-

... More
All as per item no. 51 here in before but charging of refiregent R-32

90

-

-

... More
All as per item no. 51 here in before but charging of refiregent R-410

45

-

-

... More
Supply only refrigerent R-22 gas suitable for split/ window type air conditioner in empty cylinder at AGE E/M-III storeyard complete all as specified and directed. Note: (i) Empty cylinder will be provided by the department for filling up refrigerent. (ii) Refrigerent gas purchase voucher shall be provided by the contractor. (iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed.

250

-

-

... More
All as per item no. 54 here in before but refrigent R-32

90

-

-

... More
All as per item no. 54 here in before but refrigent R-410

45

-

-

... More
M&L for disconnecting and dismentaling of blower/ condenser fan motor of window air conditioner of capacity 1.5/2.0 TR transporting for civil workshop and rewinding with new super enamelled copper conductor/ wires of superior quality with same gaudge and assembling with the AC unit and testing and commisioning complete all as specitfied directed by Engr-in-Charge.

15

-

-

... More
All as per item no 57 but fan motor of out door unit of split type air conditioner of capacity 1.5/2.0 TR

20

-

-

... More
All as per item no 57 but but fan motor of Tower AC 3.5 TR capacity

1

-

-

... More
S&F in replacement of single phase electric motor AC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.

20

-

-

... More
S&F in replacement of single phase electric motor DC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.

15

-

-

... More
M & L for disconnecting and leak almunium condenser coil from split air conditioner of capacity 1.5/2.0 TR and supply & fixing of new copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
S&F replacement sheet metal enclosure, 32 Amp single pole and nutral with a two pin and earth plug socket complete metal clad board (industrial type with MCB 32 Amp fix properly all as directed by Engr-in-charge.

10

-

-

... More
M & L for factory made MS Stand, powder coated of suitable size to mount outdoor unit of capacity 1.5/2.0 TR split AC with and including GI nut bolts of suitable size complete all as specified and directed.

15

-

-

... More
Supply of Copper rod for brezzing complete all as specified & directed by Engr-In-charge.

20

-

-

... More
S & F Nylon stranded PVC flexible pipe drain pipe of size 15 mm of length up to 3 mtr as per sample all as specified & directed by Engr-In-charge.

100

-

-

... More
S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded complete all as specified & directed by Engineer in Charge.

180

-

-

... More
Supply and fix in replacement fan blade for window AC of 1.5/2.0 TR capacity as per existing make and sample and as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply only Butane gas cartridge container not less then 230 grms or standard available in market for all as specified and dircted

160

-

-

... More
S&F replacement of condenser fan blade of outdoor unit of split type air conditioner 1.5/2.0 TR capacity as per make & sample and all as specified and directed by Engrin Charge.

20

-

-

... More
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of window AC of cap of 1.5/2.0 TR of approved make/model as per OEM, including testing and commitioning all as specified & directed by Engr-in-charge.

20

-

-

... More
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of split AC of cap of 1.5/2.0 TR of approved make/model as per OEM, including testing and commitioning all as specified & directed by Engr-in-charge.

25

-

-

... More
S&F in replacement of condenser fan motor including mounting base, rubber, clips, as per existing make and soft length in split type AC of 1.5/2.0 TR capacity complete all as specified and directed.

20

-

-

... More
S&F swing motor any type, split/ window type AC of 1.5/2.0 TR capacity complete all as specified and directed.

10

-

-

... More
S&F black insulation Tap 4" wide and up to 50 feet complete all as specified and directed.

30

-

-

... More
M & L for rewinding of burnt transformer of voltage stablizer of capacity 5 KVA with new super enameled copper conducter winding wire of existing gauge , including proper insulation and assembling with the stablizer complete all as directed by Engr-in-Charge.

10

-

-

... More
S & F in replacement of relay 25/30 Amps, 24 Volt make and capacity of 5 KVA voltage stabilizer complete all as specified & directed.

6

-

-

... More
S & F in replacement of main PCB with high and low voltage cut off PCB suitable for 5 KVA voltage stabilizer suitable making for existing all as specified & directed.

6

-

-

... More
S & F window AC kit for 1.5 TR of approved make complete all as specified & directed.

6

-

-

... More
S & F window AC kit for 2.0 TR of approved make complete all as specified & directed.

6

-

-

... More
S & F split AC kit indoor unit for 1.5 TR of approved make complete all as specified & directed.

18

-

-

... More
S & F split AC kit indoor unit for 2.0 TR of approved make complete all as specified & directed.

10

-

-

... More
S & F split AC kit outdoor unit for 1.5 TR of approved make complete all as specified & directed.

18

-

-

... More
S & F split AC kit outdoor unit for 2.0 TR complete all as specified & directed.

10

-

-

... More
Supply,fixing and replacement of Timer for Tower AC complete all as specified & directed.

4

-

-

... More
Supply,fixing and replacement of new remote with leak proof battery of suitable size of make as per OEM , including configuring with the AC unit complete all as specified & directed.

10

-

-

... More
Supply,fixing and replacement of coling coil senser complete all as specified & directed.

5

-

-

... More
Supply,fixing and replacement of remote battery complete all as specified & directed.

25

-

-

... More
Supply only Charging set with suiatble gaudge-02, three charging line complete all as specified & directed.

4

-

-

... More
Supply only gulli pench fasner of size up to 50mm long in Box / Packet containing 100 Nos fateners complete all as specified & directed.

15

-

-

... More
Supply only Insulation Tape White of size 4" and 50 feet long complete all as specified & directed.

15

-

-

... More
Supply only Taflon Tape Role White colour complete all as specified & directed.

35

-

-

... More
Supply only Thimble of any type and size in Box containg 100 Nos complete all as specified & directed.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.