Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date4 Apr 2024
Closing DateCancelled
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_649089_1Bid Award Id
ViewTender No
GE/E/LKO/T-105 OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank complete all as specified and directed by Engr-in-charge.
10
-
-
M&L for replacement of old unserviceable collector glass panel with heating resistant glass panel of size 2.08 Mtr x 1.01 Mtr of thickness not less than 8 mm incl cleaning of broken glass complete all as specified and directed by Engr-in-charge. Make-Rasmi or equivalent.
5
-
-
M&L for replacement of old unserviceable collector panel used for solar water heater based on in directed transfer of heat of capacity 100 LPD complete all as specified and directed by Engr-in-charge. make:- Rasmi or equivalent.
10
-
-
M&L for welding work of rusted portion of complete set of collector panel including metal/ GI pipe where necessary complete all as specified and directed by Engr-in-charge.
15
-
-
Taking out old U/S insulated pipe and Supply & fix Hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 15 mm bore complete all as specified and directed by Engr-in-charge.
100
-
-
All as above item No 8 but 20mm dia
80
-
-
Taking down the Geyser of any Size/Type/make from Site for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed.
Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers."
1000
-
-
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) for suitable any type/model/make all as specified and directed. (Make: Racold/Bajaj/Usha/Theeta)
750
-
-
Supply and fix in replacement thermostat(ISI Marked) suitable for any type, and capacity of geyser all as specified and directed. (Make: Racold/ Bajaj/Usha)
750
-
-
Supply and fix in replacement unserviceable indicating lamps red and green colour for suitable any Geysers complete all as specified and directed by Engr-in-charge.
650
-
-
Supply and replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasket with bolts, nuts, washers, screws of packing suitable for any type and make of geyser all as specified and directed. (Make: Racold/ Bajaj/Usha)
100
-
-
M & L for repairng of leakage of inner copper/steel tank of any type /capacity and make of Geyser by brazing including necessary denting, etc all as specified and directed.
30
-
-
Supply and replacement of unserviceable plug top 3 pin 15 Amp all as specified and directed.
400
-
-
Supply and replacement of unserviceable 3 core copper flexible round cable 4 Sqmm size all as specified and directed.
400
-
-
Supply and fix Stainless steel inner tank 25 Ltrs capacity as per existing gauge for Geysers all as specified and directed. (Make: Racold/Venus/ Dasspass)
30
-
-
Supply and fix Stainless steel inner tank 35 to 50 Ltrs capacity as per existing gauge for Geysers all as specified and directed.
(Make: Racold/Venus/ Dasspass)
20
-
-
Supply and fix 450mm long steel connection complete & both side nut with rubber washer suitable for any capacity Geyser all as specified and directed .
200
-
-
Supply and fix 600mm long steel connection with both side nut & rubber washer suitable for any capacity Geyser all as specified and directed .
100
-
-
Taking out old U/S insulated pipe and Supply & fix Hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 15 mm bore complete all as specified and directed by Engr-in-charge.
250
-
-
Taking out old U/S pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 20 mm bore complete all as specified and directed by Engr-in-charge.
200
-
-
Supply and fix MCB SP 5 to 32 Amps, 240 Volts, breaking capacity 10 kA 'C' curve complete all as specified and directed by Engr-in-charge.
500
-
-
Supply and fix factory made Sheet metal enclosure for MCB 2 way complete all as specified and directed by Engr-in-charge.
50
-
-
Supply and fix metallic top suitable for 20 Amp capacity plug & socket complete all as specified and directed by Engr-in-charge.
250
-
-
Supply and fix metallic plug base suitable for 20 Amp capacity plug & socket complete all as specified and directed by Engr-in-charge.
200
-
-
Supply and fix Switch socket combination 5 pin 15 Amps multipurpose type complete all as specified and directed by Engr-in-charge.
250
-
-
Material and labour painting of outer tank of Geyser with applying two coats of white synthetic enamel paint including writting MES No. with black paint all as specified and directed .
40
-
-
Supply and fix in replacement of brass Safety Valve heavy duty ISI marked of Geyser suitable for 15 mm bore of pipe all as specified and directed.
100
-
-
Supply and fix 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
400
-
-
Supply and fix 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
300
-
-
Taking down Ceiling fan/Exhaust fan any size any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard II for repair & hanging / fixing of the same after repair and connecting up all as specified and directed.
3500
-
-
Repair and overhauling of Ceiling fan/ Exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Testing and refixing of same fan shall be made to the entire satisfaction of Engineer-in-charge. Note: Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required (Ball bearing and Condenser) for replacement of items will be measured and paid separately.
1000
-
-
Material and labour for replacement of ball bearing of size 6201/6202/6203 all as specified and directed. Make - NBC/TATA/SKF
2500
-
-
Supply and fix Capacitor 2.5 MFd for ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep all as specified and directed. Make:- Epcos/Usha
6500
-
-
Supply and fix Capacitor 4 MFd for exhaust fan of size 450 mm/380 mm all as specified and directed. Make - USHA / EPCOS.
200
-
-
Material and labour for replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) suitable for 1200/1400 mm sweep ceiling fan all as specified and directed. .
500
-
-
Material and labour for replacement of unserviceable fan regulator electronic rotary step type 110 W (Switch in size 1 Module) suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
300
-
-
Material and labour for replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) modular type suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
300
-
-
Rewinding of Ceiling fan of 1200 mm Sweep of followings:
a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly.
b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately).
c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length.
d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction of the Engr-in-Charge.
Note: Rewinding shall be carried out in Yard No II, Painting of Fans deemed to be include in respective Item.
3400
-
-
All as above item no 41 but Ceiling fan of 1400 mm Sweep
200
-
-
All as above item no 41 but Exhaust fan 450 mm (18") to 600 mm (24") Sweep
50
-
-
All as above item no 41 but Exhaust fan 380 mm (15") Sweep
50
-
-
All as above item no 41 but Exhaust fan 300 mm (12") Sweep
400
-
-
All as above item no 41 but Exhaust fan 242 mm (9") Sweep
250
-
-
All as above item no 41 but Wall fan 400 mm Sweep
100
-
-
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1200 mm Sweep all as specified and directed.
120
-
-
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1400 mm Sweep all as Specified and directed
50
-
-
Supply and fixing Blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan all as Specified and directed.
40
-
-
Supply and fixing Blade Set with frame & four legs of fan with coupling for 380 mm (15") Sweep exhaust fan all as Specified and directed.
50
-
-
Supply and fixing Blade Set with frame & four legs of fan with coupling for 300 mm (12") Sweep exhaust fan all as Specified and directed.
30
-
-
Supply and fixing Blade Set with frame & four legs of fan with coupling for 230 mm (9") Sweep exhaust fan all as Specified and directed.
40
-
-
Supply and fixing Blade set of cabin fan suitable for 400 mm sweep all as specified and directed.
50
-
-
Supply and fixing Twisted twin core flexible copper cable of size 23/0.0076 all as specified and directed. Make - Seiko/Paragon/Finolex/Havells/Anchor.
3000
-
-
M &L for Spray painting of fan with one coat of super enamel white paint after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint all as specified and directed.
50
-
-
M&L for replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubber reel, split pin, bolts, nut and washer all as specified and directed.
250
-
-
M&L for replacement of worn out/defective roter shaft of ceiling fan, exhaust fan, cabin fan of any make and size all as specified and directed.
250
-
-
S&F for ceiling fan canopy set of two all as specified and directed.
200
-
-
Taking down U/S Ceiling fan/Exfan/wall fan of any Size/Type/Model and handover MES Store EM Yard-II for BER process complete all as specified and directed by Engr-in-charge.
71
-
-
Repair/Replacement of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge. Make:- Bajaj/Havells/Crompton/Usha
11
-
-
Repair/Replacement of ceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated all as specified and directed by Engr-in-Charge. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibelwire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of exhaust fans single phase 230/240 Volts metalic body of size 225/230 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of PVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
10
-
-
Repair/Replacement of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Litre to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body,Product warranty-2 Years, Heating element warranty-4 Years, Inner Tank warranty-7 Years, including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed.
2
-
-
Repair/Replacement of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 50 Litre to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body,Product warranty-2 Years, Heating element warranty-4 Years, Inner Tank warranty-7 Years, including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed.
1
-
-
Reapir/Replacement of Pressure pump motor, single phase, 230Volts, 50 Hz, of capacity 1.0 HP complete of pressure pumps & systems Model No-100B Pressurejet including making connections complete all as per specified and directed by the Engr-in-Charge.
1
-
-
Taking down/dismantling of Pressure pump of any capacity from site and Rewinding of Pressure pump and other minor repairs incl sensor etc, removing old wire & winding with copper wire and complete overhauiling of pump etc all as specified and directed.
1
-
-
Taking down U/S chimney and S&F of electric chimney single phase 230 Volt including push control, baffle filter, metal blower, min suction power 800 Cum/Hr, black powder coated with min size L-90 cm and S-60cm and all accessories complete all as specified and directed.
1
-
-
M&L for writting name in LED lighting system with enclosure size 3 mtr x 0.8 mtr CGI Sheet min 2.0 mm thickness (AGE E/M (EAST) YARD-II LUCKNOW) with minimum size 300 x 50 mm in PVC material IP-66 of complete as per sample complete all as specified & directed.
1
-
-
S&F energy saving ceiling fan of 1200 mm sweep of 330-370 RPM, 220-240 volts, AC, 50 Hz, ISI marked with five star rating including hanging with the help of fan hook, down rod up to 04 feet and connecting up with provn of 3 core copper flexible cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed. Make : Havells, Model: ES-50 Premium or Usha, Model: Energia Star ISI or Crompton Greaves, Model: Empower 50
-
-
-
Evaluation Notes How It Works ?