Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Excavation
Eprocure
Opening Date19 Feb 2024
Closing Date19 Mar 2024
Tender Amount₹ 14,35,000
Costs
EMD
₹ 28,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643115_1Bid Award Id
ViewTender No
CWE(AF)/CHK/MNR/T-73 OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required of size 32 x 6 mm galvanised iron strip including taking down old unserviceable earth continuity conductor complete all as specified and directed.
600
-
-
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required of size 25 x 3.15 mm galvanised iron strip including taking down of unserviceable aluminium strip complete all as specified and directed.
350
-
-
M&L air termination single pointed aluminium rod 12 mm dia and 300 mm long complete including taking down of unserviceable air termination single pointed aluminium rod all as specified and directed.
60
-
-
M&L test point terminal block made out of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexogonal head screw including taking down of unserviceable test point terminal block complete all as specified and directed.
75
-
-
S&F in replacement of high density polythene pipe (HDPE) pipe PN10 50mm bore suitable for 6 kgf/sqcm working pressure laid in trenches for protection of GI strip from test point to top level of earthing complete all as specified and directed.
80
-
-
S&F PVC flexible conduit 32 mm dia on wall/ top of roof/ roof sheet for providing isolation to aluminium strip from wall/ metal sheet on roof complete all as specified and directed.
60
-
-
M&L fabrication, installation sign board indentifier / marker ( 30cm x 20cm board Preferably metallic in Oval shape) of 22 SWG and stand of made out of angle iron of size 40 x 40 x 6mm thick of length 90cm (60 cm above ground level) and duly painted with two coat of syenthetic enamel paint of RED colour for background over a coat of red oxide primer and marked 'LA' letters of size 1 inch height in black paint text as directed and to be grouted 2 feet from the ground level including all excavation and earth work. It will mention the type of earthing, number of the earth pit and the total number of particular type of earthing for that building equipment. For example, a lightening earth pit can be marked as LA 1/4 which means lightening arrester EP No 1 out of 4 LA earth pits for the building including taking down old one complete all as specified and directed.
30
-
-
M&L fabrication, installation sign board indentifier / marker ( 30cm x 20cm board Preferably metallic in half oval with half rectangle shape) of 22 SWG and stand of made out of angle iron of size 40 x 40 x 6mm thick of length 90cm (60 cm above ground level) and duly painted with two coat of syenthetic enamel paint of YELLOW colour for background over a coat of red oxide primer and marked 'SG' letters of size 1 inch height in black paint text as directed and to be grouted 2 feet from the ground level including all excavation and earth work. It will mention the type of earthing, number of the earth pit and the total number of particular type of earthing for that building equipment. For example, a Signal earthing pit can be marked as SG 1/4 which means signal earthing SG No 1 out of 4 SG earth pits for the building including taking down old one complete all as specified and directed.
15
-
-
M&L fabrication, installation sign board indentifier / marker ( 25 cm x 25 cm board Preferably metallic in triangle shape) of 22 SWG and stand of made out of angle iron of size 40 x 40 x 6mm thick of length 90cm (60 cm above ground level) and duly painted with two coat of syenthetic enamel paint of RED colour for background over a coat of red oxide primer and marked 'EQ' letters of size 1 inch height in black paint text as directed and to be grouted 2 feet from the ground level including all excavation and earth work. It will mention the type of earthing, number of the earth pit and the total number of particular type of earthing for that equipment. For example, a equipment earthing pit can be marked as EQ 1/4 which means equipment earthing EQ No 1 out of 4 EQ earth pits for the equipment including taking down old onecomplete all as specified and directed.
10
-
-
Supply and fixing of 40 mm bore GI pipe medium grade ISI marked as per IS:1239 with all GI fittings, laid in trenches/wall including taking down old pipe complete all as specified and as directed.
600
-
-
Supply and fixing of 15 mm bore GI pipe medium grade ISI marked as per IS:1239 with all new GI fittings, laid in trenches/wall including taking down old pipe complete all as specified and as directed.
350
-
-
S & F plug type bib taps, cast iron, screwed for iron pipe and fixed for 15 mm dia pipe includinh taking down old unsv bib tap complete all as specified and directed.
70
-
-
Labour only for cutting /boring to plinth protection /hard standing/road etc in suitable depth and for laying /corssing to GI strip size 32x6 MM in 45 CM depth minium complete all as directed. Note:- Quoted rate shall be included the cost of required material for repair to disturbed surface in existing.
20
-
-
M&L for re-fixing to aluminium/ galvanised / copper strip in any size fixing on saddle type insulators using broung nut bolts and washer etc/ reveting by aluminium reveits for jointing to strip/ laid in trench/ fix on surface of wall/ beam etc as site required making circuit continuty with making straight all as directed. Note ; Quoted rate shall be including cost insulator etc all (ii) Porcelain type insulator and fixing screws shall be provided @ 3 Nos per RM for fixing of strip.
200
-
-
M & L providing PCC 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in foundation of size 150 mm x 150 mm cross section, planting depth 0.30 Mtr for concrete encasing the pole upto GL and including form work finished even and fair complete all as specified and directed.
5
-
-
M & L providing PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for plinth block/Collar above GL 150 mm high of size 150 mm x 150 mm and including form work finished even and smooth with using extra cement complete all as specified and directed.
2
-
-
Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation , shaft well, cesspit, manholes, pier hole etc and not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified & directed.
95
-
-
Returning, filling in, including, spreading, leveling, watering & well ramming in layers not exceeding 25 CM complete all as specified & directed.
88
-
-
Removing excavated material exc. 250 m but n exc. 500 m (out side MD land) and depositing where directed at contractor's own arrangement complete all as specified & directed.
7
-
-
Material & Labour for chemical to burn out the shrub/grass/ unwanted small trees etc 100% in outfit area of near building earthing pit in AOR spread by using spray gun equally in a given time interval as directed. Note: Chemical sample shall be supplied in sealed container 2 to 5 Ltrs each after approved by Deptt. complete all as specified & directed. Make :- Glycel or equivalent as approved by AGE(I)
15
-
-
Supply and fixing in replacement of copper strip 32 x 6 mm thick including porcelain type insulator fixed on 1 Mtrs apart interval with screws / reveting/ nut bolt washer etc for mounting to strip as roof conductors and down conductors upto 1.2 Mtrs above the normal ground complete all as specified and directed. Note: Porcelain type insulator and fixing screws shall be provided @ 2 Nos per RM for fixing of strip.
20
-
-
M&L in replacement of heavy duty saddle type porcelain type insulator for holding to GI / copper strip with bronze nuts bolts and washers etc all as site requirement and directed.
200
-
-
Supply and fixing Rolled Miled steel Framed work as in top of temp bldg for fixing of air termination confirming to Fe 410-W (gde-E-250) quality-A with gusset plates, rails braces, etc. complete, drilled for fixing of steel sheeting or other covering and hanging and fixing including taking out rusted frame complete all as specified and directed by Engr-in-Charge.
45
-
-
Material and labour for repair of existing earthing concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I complete all as specified and directed by Engr-in-Charge.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements