Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Nov 2024
Closing Date30 Nov 2024
Tender Amount₹ 43,00,000
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maintenance And Improvement Of Lt Panel Including Lt Switch Gear , Earthing, Timer Panel , Lt Poles, Pole Box, Outdoor Street Lights,lt Distribution Network Ar 11grrc, Chetak Line,manoj Pandey Fafa Md Accn, Race Course, Sanjog Chetri Vihar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679124_2Tender No
CWE/LKO/EM/T-61 Of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.
Note: Punned thickness shall be considerd for measurment purpose
181.44
-
-
M & L for fly ash bricks straight curved on laying in trenches perpendicular to axis of the cable complete all as specified and directed.
14
-
-
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed by Engineer in Charge
30
-
-
Supply, laying jointing and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. Note- Excation, earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under given items.
200
-
-
-- do-- as per item no. 7 above but size 35 sq mm 3.5 core
200
-
-
-- do-- as per item no. 7 above but size 50 sq mm 3.5 core
400
-
-
-- do-- as per item no. 7 above but size 16 sq mm 4 core
1000
-
-
-- do-- as per item no. 7 above but size 120 sq mm 3.5 core
200
-
-
-- do-- as per item no. 7 above but size 10 sq mm 4 core
1200
-
-
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
10
-
-
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
10
-
-
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
5
-
-
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 100 mm bore for protection of cable complete all as specified and directed by the Engineer-in-Charge.
5
-
-
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
20
-
-
S&F in replacement wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
140
-
-
Supply and errection in of 05 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps, Cat NO: HM-1107 P for pole and HM-SA 1 M for bracket. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 as per pole manufacturer's drawing and earth work all as per requirement complete all as
5
-
-
Supply and errection in of 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps, Cat NO: HM-1107 P for pole and HM-SA 1 M for bracket. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 as per pole manufacturer's drawing and earth work all as per requirement complete all as
10
-
-
Shifting/Removing and refixing of LT pole 9 mtr/Octagonal pole 5/7 mtr from one place to another places of entier Cantt area , including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed.
20
-
-
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
22
-
-
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated Timer panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40x40x6mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50x50x6mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :-
(i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos
(ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos
(iii) Astronomical Digital Timer Switch 240 V AC -01 Nos
(iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three
(vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing
(i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
2
-
-
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated LT Panel board(Dimention of Cubical/enclosure not less than 900mmx600mmx500mm) ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :-
(i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos
(ii) Digital VAF+PF meter with RS 485 CL1 -01No
(iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three
(v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing
(i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 06 Nos
2
-
-
M&L in replacement out door type busbar panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No
(c) LED Indicator lamp RYB - 01 set of three.
3
-
-
Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300x300x6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 10mm thick in1:6 cement mortar complete all as specified and directed.
20
-
-
M&L for painting of steel tublar/rail pole 09/11 meter long with silver aluminium paint of two coat after preparing surface & Marking number on pole with black paint complete all as specified & directed by Engr-in- charge.
400
-
-
Cleaning the existing painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
25
-
-
Supply and fixing in replacement CRCA MS sheet for LT panel having thickness 3.15 mm powder coated finish over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer including all fixing acessories i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc complete all as directed by Engr -in-charge
25
-
-
Supply, fixing, connecting and testing in replacement MCCB 63 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
10
-
-
Supply, fixing, connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader thermal magnetic release after taking down old existing unserviceable MCCB complete all as directed.
4
-
-
Supply, fixing, connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
3
-
-
Supply, fixing, connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
2
-
-
Supply, fixing, connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
4
-
-
Supply, fixing, connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
5
-
-
Supply, fixing, connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
2
-
-
Supply, fixing, connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
1
-
-
Supply and fix in repair Isolator 100 Amps 4 pole fixed in position all as specified and directed
47
-
-
Supply, fixing, connecting and testing in replacement MCCB 200 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with sheet metal enclouser of 1.6 mm thick MS sheet factory made with poweder coat paint including connecting with existing system. after taking down old existing unserviceable MCCB complete all as directed.
8
-
-
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor .
6
-
-
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 120 sqmm XLPE armoured aluminium conductor
4
-
-
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 150 to 185 sqmm XLPE armoured aluminium conductor
3
-
-
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 240 to 300 sqmm XLPE armoured aluminium conductor
2
-
-
M & L for PCC 1:3:6 type C1 using stone aggregate of 20mm nominal size in foundation concrete for coping of poles all as specified including demolition of exisiting coping..
4
-
-
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
1
-
-
Supply and fixing in replacement of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110_ lumen per watt system efficency ,power factor 0.95, THD10% at Full load CRI 70% ,Street light should have built in potted DriverTHD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.
Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
30
-
-
Supply and fixing in replacement of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110_ lumen per watt system efficency ,power factor 0.95, THD10% at Full load CRI 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.
Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . .
45
-
-
Supply and fixing in replacement of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution . street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100_ lumen per watt system efficency ,power factor 0.95, THD10% at Full load CRI 70% ,Street light should have built in potted IP 66 electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.
Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
20
-
-
Supply and fixing in replacement of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110_ lumen per watt system efficency ,power factor 0.95, THD10% at Full load CRI 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.
Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement
25
-
-
Supply and fixing bollard light 60 cm long 10 - 12 watt LED Bollard light having epoxy powder coated pressure die cast aluminium housing Light optic /Diffuser - High impact polycarbonate/Optic colour temprature 5700K CRi70,THD10% PF .90 surge protection 4KV inbuilt ,Rated voltage and frequency 240 Volt,50 Hz street furniture with touch if aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental complete with foundation work nut,bolt and washer etc complete all as specified and directed by Engr in Charge.
10
-
-
S&F Post top energy saving 240V,50Hz AC, environmental friendly, aesthetically designed electronic constant current,IK07, having epoxy powder coated pressure die cast aluminium housing Top cover spun Al sheet powder coated,front cover Clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source of capacity 40 Watt, 5700K PF 0.9, THD10% and light efficiency 85_ ,CRI 70,Surge protection 5KV incl dismentling taking down unsv fitting any type all as specified and directed.
4
-
-
Supply and fixing security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos clamp made out of 50mm x 5mm flat iron and 06 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note - including taking down old and unsv.
50
-
-
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 45 to 90 Watt LED flood light/street light fitting as required at site or as per exisiting sample. Note - including taking down from pole and refixing the same place after repairing.
32
-
-
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per exisiting sample.Note - including taking down from pole and refixing the same place after repairing.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%