Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date10 Jan 2025
Closing Soon12 Feb 2025
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692568_1Tender No
8753/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Note:- 1. The detail of firedetection & fire fighting system are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 4 Nos.
(c) UL Listed intelligent heat detector - 02 Nos. (d) Auto dialer - 01 Nos. (e) External siren - 02 Nos. (f) Nitrogen gas cyclinder 2.2 Kg - 05 Nos. (g) Carbon di oxide cyclinder 45 Kg - 16 Nos.
(h) Manual call point - 08 Nos.
(i) Control module for hooter - 4 Nos.
(j) zone Monitor module - 4 Nos.
(k) Fault isolator - 08 Nos.
(l) Response indicator - 12 Nos.
(m) IR Flame detector - 02 Nos. (n) UR Gas detector - 04 Nos. (o) Smoke detector - 02 Nos
(p) UPS 500 VA - 01 No. 2. Detection system shall be tested monthly along fire fighting system. 3. Fire fighting system and complete system efficiency along with release of Carbon di oxide and Nitrogen shall be tested at least once in three month. 4. Weighing of Carbon di oxide and Nitrogen per month shall be done.
-
-
-
... More
Comprehensive monthly maintenance of auto fire alarm system installed in TTCLE Hanger in Tech areaat AF Stn Chakeri. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system.
(ii) Operational of all the equipment of fire detection system should be maintained.
(iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through experienced technician.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule.
9
-
-
... More
Note:- The detail of fire detection & fire fighting system are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No.
(b) UL Listed intelligent addressable multi-sensor detector with heat & smoke combination-492 Nos.
(c) UL Listed intelligent heat detector -04 Nos
(d) Manual call point - 20 Nos.
(e) Audio visual indication of smoke or fire-20 Nos.
(f) zone Monitor module (g) Fault isolator - 30 Nos
(h) Wall mounted hooter - 20 Nos
(j) Response indicator -100 Nos
(k) IR Flame detector (l) UPS 500 VA
-
-
-
... More
Repair, comprehensive and preventive maintenance of CO 2 flooding system in ROH flight (one nos two zone panel, 8 Nos CO2 Cylinder and 01 Nos N2 Cylinder ) as per manufacturers reccomendation which include the following:-
(i) Checking and cleaning of smoke/ heat detectors ,nozzles/Co2 pipe line etc complete all as specified & directed. (ii) Checking of main control panel and control wiring complete all as specified and directed. (iii) weighing of CO2 /N2 cylinders complete all as specified and directed. Note :(a) If any defect notice/found ,the same should be rectify immediatly and report to Engr-in-charge. (b) Spares shall be measured and paid separately under relavent item of schedule. (c) If defect not rectified by contractor with in stipulated period as directed by Engr-in-charg then penality @ 500/per day will be recover from RAR /BILL. Testing of the entirefire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
9
-
-
... More
Supply & Fix in replacement intelligent Analogue addressable multicriteria type heat with smoke detector with base. (Bearing Lab & H-19). Make shall be as per site requirement of existing make compatible with main fire alarm panel
Make : Honeywell / Siemens
370
-
-
... More
Supply only optical type conventional Multisensor smoke with heat detector supply voltage 9 to 33 V DC ,UL/FM/LPC approved with junction box and base to be fixed with suitable fixing arrangement complete Make Apollo/system sensor/Siemens
40
-
-
... More
Supply only of Intransically safe Conventional photoelectric smoke Detector UL/FM/LPC approved with junction box and base complete to be fixed inside test rig with suitable fixing arrangement complete all as specified and directed. Make Apollo model Orbis cat part No ORB-OP-52027-APO/ Systen senser cat part No JTY-GD-2151 EIS or equivalent make in Hochiki / BOSCH.
5
-
-
... More
Supply only of Intransically safe Conventional heat detector class AIR, UL / FM / LPC approved with base complete all as specified and directed. Make Apollo Model Orbis cat part No ORB-HT-51145-APO / Systen senser cat part No JTWB-BCD-5151EIS or equivalent make in Hochiki / BOSCH
5
-
-
... More
Supply only optical type smoke detector supply voltage 9 to 33 V DC ,UL/FM/LPC approved with junction box and base to be fixed inside test rig with suitable fixing arrangement complete Make Apollo/system senser/Siemens
20
-
-
... More
Supply only fixed cum ROR type heat detector class AIR supply voltage 9 to 33 VDC , UL/FM/LPC approved with base complete . Make Apollo /System senser/Siemens
20
-
-
... More
Supply & Fix in replacement intelligent Analogue conventional type manual call point with box resettable type complete all as specified. Make :MOORLEY/APOLLO / Siemens/Honeywell.
5
-
-
... More
Supply & fix in replacement of intrinsically safe and weather proof addressable type manual call point with push button fired bride box sealed with glass including necessary electrical connection complete all as specified and directed. Make Agani / NSD / Agani Alarm / System sensor
10
-
-
... More
Supply & Fix in replacement addressable type Electronic hooter cum strove to provide audio visual indication of smoke or fire with public address system compatibility complete all as specified.Make : MOORLEY/APOLLO /Siemens /Honeywell.
15
-
-
... More
Supply & fix in replacement of low intensity hooter for warning of fire connected with central contol panel installed in each zone inside the rooms complete all as specified and directed. .Make Agani / NSD / Agani Alarm / System sensor
3
-
-
... More
Supply and fixing in replacement External Siren 2 KM range with control panel complete all as specified and directed. Make:- Kheraj / KPT / National / System senser
1
-
-
... More
Supply & Fix in replacement remote response indicator complete all as specified. Make : MOORLEY/ APOLLO/ Siemens /Honeywell/ AGNI
30
-
-
... More
Supply & Fix in replacement Fault isolator to prevent short circuit/open circuit complete all as specified. Make : MOORLEY/APOLLO/Siemens /Honeywell.
5
-
-
... More
M & L for repair of loop microprocessor based fully analog addressable type fire alarm repeater panel complying with BSEN 54 single loop panel of capacity upto 200 detector and module (per each loop) including replacement of faulty part all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley
1
-
-
... More
M&L for power supply high current power supply that provides fire finder-XLS panel system with primary regulated 24 VDC, it should be rated at 12 A and built in charger & should be capable of charging up to 100ah battries, should have microprocessor controlled transfer circuit, PSC-12 of Siemens complete all as specified and directed.
2
-
-
... More
M&L for Programming Unit & comissioning / recalibrating with Siemens software programming and testing of Detector and devices of fire finders-XLS and wiring loops for ground faults and shorts circuits,communication of installed devices and addresses of all devices of Siemens complete all as specified and directed.
2
-
-
... More
Supply & fixing in replacement of electric solenoid operated actuator code 20126-1.2-2G-S8 DC 24 Volt 11 Watt type 6 Size II all as per IS 8935 for operating the value of nitrogen cylinder complete all as directed by Engineer in Charge. Make Rotex /KEW
4
-
-
... More
Supply and fix in replacement of PCB loop card suitable for self addressable fire finder system. - XLS panel
Make: Siemens/Honeywell
1
-
-
... More
Supply & fixing in replacement of pneumatic actuator made of brass on CO2 cylinder ISI marked IS 3224, complete .Make KEW /Rotex
16
-
-
... More
Supply & fixing in replacement of wire braded high pressure discharge hose 3/8" WP 3024 PSI /210 BAR on CO2 cylinder complete.
8
-
-
... More
Supply & fixing in replacement of lead acid battery of 12 Volt, 7 AH complete all as directed.Make EXIDE /OKAYA/AMRON
12
-
-
... More
Supply & fixing in replacement of lead acid battery of 12 Volt, 180 AH complete all as directed.Make EXIDE /OKAYA/AMRON
2
-
-
... More
Supply and filling CO2 gas in fire extinguisher of different capacity including Transportation for refilling from site to workshop on to & fro basise including testing of cylinder before filling the gas complet all as directed.
1170
-
-
... More
Supply and filling N 2 gas in fire extinguisher of different capacity including Transportation for refilling from site to workshop on to & fro basis including testing of cylinder before filling the gas complet all as directed.
45
-
-
... More
Supply and fixing in replacement Nitrogen gas cylinder 4 Kg Pilot with nitrogen gas ISI marked complete all as specified and directed. Make EKC / RAMA / CCOE/ OMEX
2
-
-
... More
Supply and fixing in replacement Single stage regulator(Two GAUGE) NITROGEN Regulator complete with necessary connecting brass parts complete all as specified and directed. Make ESAB india limited model INI 42B
4
-
-
... More
M & L for fabrication of mild steel flats iron clamp,angle iron , nut bolt and washer etc for supporting to CO2 gas pipe line including painting with one coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
200
-
-
... More
Supply & fixing in replacement of gun metal landing valve single headed 80 mm dia, flanged inlet 63 mm dia instant type female outlet complete with gun metal cap complete all as directed. Make G Tech/GEM/New Age/Flamex/ Omex
5
-
-
... More
Supply & fixing in replacement of 63 mm dia RRL hose pipe 30 Mtr long with instantaneous type gun metal 63 mm dia ISI marked male & female couplings bend riveted to hose pipe complete all as directed. Make New Age/Atasi/Omex
8
-
-
... More
S&F in replacement of MS ERW pipe 200 mm bore class C heavy duty including cutting and welding , fittings for fire pipe line in pump house all as directed. Make- Jindal/Tata
6
-
-
... More
All as per item no 34 but pipe size 150 mm
24
-
-
... More
All as per item no 34 but pipe size 100 mm
18
-
-
... More
All as per item no 34 but pipe size 80 mm
12
-
-
... More
All as per item no 34 but pipe size 40 mm
40
-
-
... More
All as per item no 34 but pipe size 25 mm
54
-
-
... More
M & L for two coats painting of plant MS platform angle/pipe/ channel support MS tank from out side cable tray and other related surface using Synthetic enamel paint of existing colour including removing rust/dust and oil from surface and writing letters etc complete all as directed
50
-
-
... More
Supply and laying in replacement XLPE insulated PVC sheathed armoured copper conductor 1.5 Sqmm 2 core on surface with fitting complete Make Fionlex /Plaza/Havells.
690
-
-
... More
Supply & fixing in replacement of display card microprocessor based detecting system of CO2 flooding system for digital panel complete all as directed.
11
-
-
... More
Supply & fixing in replacement of zone card for microprocessor digital panel complete all as directed.
8
-
-
... More
Supply & fixing in replacement of gas flooding control card for microprocessor digital panel of CO2 flooding system for digital panel complete all as directed.
10
-
-
... More
Supply & fixing in replacement of SMPS power supply including transformer of CO2 flooding system for Microprocessor digital panel complete all as directed.
8
-
-
... More
Supply & fixing in replacement of adaptor for N2 gas cylinder making all arrangement to arrest leakage of gas for digital panel complete all as directed.
9
-
-
... More
Repair and maintenance of automatic system of Fire pump house including replacement of control wiring ,relay,contactor etc making automation/ serviceable including replacement of minor parts to make functional and interlocking of jockey pump ,main fire pump and fire engine pump set including testing complete all as directed by Engineer in Charge.
1
-
-
... More
S&F in replacement of pressure switch universal type as per existing type all as directed.Make Indfos
3
-
-
... More
Disconnecting the connection from prime mover including taking out of Armature set of capacity 90 BHP from the existing position and strip opening, cutting the burnt out winding in feild coil, cleaning the stator and re-winding the same with super enameled copper winding wire of same gauge using top class of insulating material and over hauling of armeture including lath/ machine work for making housing of bearing , metaling ,welding, turning surfacing ,polishing of rotor shaft, and rethreading and replacement of, bearing of required size (Make-NBC/SKF), bushes, rubber insertion sheet , nuts, bolts and washers including necessary other items for its smooth functioning and testing complete reassembling the same and re-fixing back in its original position complete all as specified and as directed.
1
-
-
... More
Repair and preventive maintenance of 55 KW centrifugal pump which include replacement of bearing ,gland etc. and tightening of nuts bolts, washers greasing etc for proper running of pump and checking of all electrical connections from engine to panel and make it functional in manual/auto mode all as directed. Note : spares parts shall be measured and paid separately
1
-
-
... More
Repair and preventive maintenance of Centrifugal fire pump 15 KW , which include replacement of bearing ,gland etc. and tightening of nuts bolts, washers greasing etc for proper running of pump and checking of all electrical connections from engine to panel and make it functional in manual/auto mode all as directed. Note : Spares Parts shall be measured and paid separately
1
-
-
... More
Supply only Bearing of centrifugal pump 55 KW exsisting size Make SKF/Tata/NBC
2
-
-
... More
Supply only Bearing of Centrifugal fire pump15 KW exsisting size Make SKF/Tata/NBC
2
-
-
... More
Supply only rubber bush for coupling.
2
-
-
... More
Supply only Gland bush set complete.
2
-
-
... More
Supply only Gland packing including nut & bolts suitable for 15/55 KW fire pump and engine set .
4
-
-
... More
Repair and preventive maintenance of Fire diesel engine pump set 93 BHP capacities which include tightening of battery terminals,checking of oil level , greasing ,filling of distilled water in battery etc and any minor repair to make engine set functional complete.
9
-
-
... More
Supply and fixing Rubber hose pipe engine set 93 BHP
1
-
-
... More
Supply and fixing Oil pressure pipe of Engine set 93 BHP
4
-
-
... More
Supply and fixing Coolant for radiator of any type of DG set Make Castorl/Servo ./HP
4
-
-
... More
Supply only Lub Oil filter of engine set 93 BHP Make- Mico /Kirloskar/Fleet guard
1
-
-
... More
Supply only Diesel filter of engine set 93 BHP Make- Mico /Kirloskar/Fleet guard
1
-
-
... More
Repair and overhauling and servicing of self starter 12 V by replacement of clutch,carbon bush etc complete.
1
-
-
... More
Supply and filling of Engine oil 20W40 Make Castrol/Servo/HP
10
-
-
... More
Cleaning of semi under ground water sump of capacity 20000 Gls approx inside by Mechanised de-watering by using industrial submersible pump, Scrapping sludge and removal by using industrial sludge pumping, Cleaning of all dust particle,Sterilization of sump by using chlorination chemical on internal surfaces of wall including preperation of surfaces, writing date of cleaning of sump with white paint on black base as specified and directed.
1
-
-
... More
Supply & fixing in replacement sluice valves 150 mm dia class PN-1.6 , IS-14846 with flanged ends, stainless steel spindle and iron wheel including nut bolts and rubber packing complete Make Kirloskar /Upadhaya /GDPA/Kartar
1
-
-
... More
All as per item No 66 but 100mm bore
1
-
-
... More
Supply & fixing in replacement Non return valves 150 mm dia class with flanged ends, stainless steel spindle and iron wheel including nut bolts and rubber packing complete Make Kirloskar /Upadhaya /GDPA/Kartar
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%