Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 May 2024
Closing Date1 Jun 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_652177_1Bid Award Id
ViewTender No
8200-1410/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://MilitaryEngineerServices
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only under voltage trip device suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
2
-
-
... More
Supply only Adapter type terminal suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
2
-
-
... More
Supply only in replacement of Spring charge indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
2
-
-
... More
Supply only trip indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
2
-
-
... More
Supply only position indication switch suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
1
-
-
... More
Supply only on/off push button suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
1
-
-
... More
Supply only on/off neutral CT suitable for ACB capacity upto 800 Amp, 4 pole, 50 HZ, AC complete all as specified and as directed.
1
-
-
... More
M&L for prepration of old steel surface of LT Panel board/Feeder Pillar box of any size by scrubing the existing damage paint and applying of two coats of synthetic enamel paint over a coat of red oxide primer at various location in Mathura Cantt complete all as specified and as directed.
22
-
-
... More
M&L for welding works to LT Panel/Bus Bar/Feeder pillar box for fixing/welding hinges, locking arrangement or repair the pitted area of panel etc at site complete all as specified and as directed.
18
-
-
... More
Cutting wild grass, bushes, creaper, unwanted vegetation from inside / surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed / cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing complete all as specified and as directed.
Note : The item shall be operated maximum three times in entire period of contract in the same installations. (Area shall measured separately each time).
4000
-
-
... More
Supply, installation, testing and commissioning of outdoor type Bus bar box made out of 3.15mm thickness for outer sheet and 2mm for inner sheet suitabe for 3 phase, 4 wire, 415 volt, 50Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust/vermin proof and & general construction confirming to IS/IEC : 614391:1:2011 mounted on suitable PCC M-15 grade (Nominal mix) (using 20mm graded stone aggregate) in foundation comprising of the following :- (a) Aluminium basbar of 800 Amp for three phase and 600 Amp for neutral.
(b) MCCB 630 Amp, 4 Pole, 50KA, 415 volt - 01 No (for incoming)
(c) MCCB 400Amp, 4Pole, 35KA, 415 volt - 02 Nos (for outgoing)
(d) Digital type volt meter (0-500v) with selector switch & CTs- 01 No
(e) Digital type Ammeter (0-600A) with selector switch and CTs-01 Nos.
(f) Indicating lamp LED cluster type set of three in RED/BLUE/GREEN colour-01 Nos
Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
1
-
-
... More
Supply and fixing in replacement of 3 phase volt meter, 0-500 volt digital type square or rectangle type 96 sq mm lamp accurracy glass complete all as specified and as directed.
12
-
-
... More
Supply and fixing in replacement of 3 phase Ammeter, 0-500 Amp digital type square or rectangle 96 sq mm lamp accurracy glass complete all as specified and as directed.
12
-
-
... More
Supply and fixing in replacement of CT coil suitable for Amp meter 100/5 Amp complete all as specified and as directed.
15
-
-
... More
Supply and fixing in replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type to match the existing one complete all as specified and as directed.
12
-
-
... More
Supply, installation, testing and commissioning of outdoor double door LT feeder pillar box, cubical type suitable for 3 phase 4 wire, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 200 Amp - 04 Nos (three phase and one neutral) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following:- (a) MCCB 100 Amp, 4 Pole, 16KA (Ics=100% Icu)- 01 No(IC)
(b) MCCB 63Amp, 16 KA, 3 Pole (Icu=100%Icu)- 02 No(OG)
(c) Bare MCCB space - 02 Nos
(d) Aluminium Bas bar (RYB & N) with 4 Nos outgoing arrangement -- 01 Set
(e) Three Phase LED indicator switch RY&B
Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
2
-
-
... More
Supply and laying electrical insulation rubber mating for installations of size 1mx2mx25mm thick as per latest IS complete all as specified and as directed.
5
-
-
... More
Supply and laying electrical insulation rubber mating for installations of size 1mx2mx20mm thick as per latest IS complete all as specified and as directed.
5
-
-
... More
Supply, installation, testing and commissioning of outdoor type LT feeder pillar box, cubical type suitable for 3 phase 4 wire, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 400 Amp for Three phase and 400 Amp for neutral (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following:- (a) MCCB 250 Amp, 4 Pole, 25KA, adjustable thermal and adjustable magnetic - 01 No(I/C)
(b) MCCB 125 Amp, 16 KA, 3 Pole adjustable thermal and adjustable magnetic - 01 No (O/G)
(c) Digital type volt meter (0-500v) with selector switch- 01 No
(d) Digital type Ammeter (0-600A) with selector switch and CTs-01 Nos.
(e) Indicating lamp LED cluster type set of three in RED/BLUE/GREEN colour-01 Nos
Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
1
-
-
... More
Supply, installation, testing and commissioning of outdoor double door LT feeder pillar box, cubical type suitable for 3 phase 4 wire, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 300 Amp - 03 Nos for phase and 01 No for neutral (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following:- (a) MCCB 160 Amp, 4 Pole, 25KA - 01 No (for incoming)
(b) MCCB 63 Amp, 4 Pole, 16KA - 06 No (for outgoing)
(c) Digital meter with Voltmeter (0-500V) - 01 Nos
(d) Rating of CT & Ammeter as per Bus bar capacity as mentioned in BOQ
(e) Selector switch for Ammeter (RYB) - 01 Set
(f) Selector switch for Voltmeter (RYB & BR) - 01 Set
(g) Incoming Lamps (RYB) - 01 Set
Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
2
-
-
... More
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundations, laying of cables etc. and getting out as in soft/loose soil complete all as specified and as directed.
723
-
-
... More
M&L for clean dry Yamuna sand laid in trenches/ducts for bedding and cushioning to cable including spreading and levelling complete all as specified and as directed.
Note : Punned thickness of sand shall only be measured for payment purpose.
217
-
-
... More
Supply and Laying in trenches Unreinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm for cable protection cover laid adjacent to each other lengthwire perpendicular to central axis of cable complete all as specified and as directed.
17850
-
-
... More
Returning filling in earth obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick filling back trenches after outer cable has been laid and tested complete all as specified and as directed.
431
-
-
... More
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
292
-
-
... More
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, armoured heavy duty electric underground cable, aluminium conductor 1100 volt grade of following cross sectional area :-
-
-
-
... More
16 Sqmm 4 core.
350
-
-
... More
25 Sqmm 3.5 core.
450
-
-
... More
35 Sqmm 3.5 core.
400
-
-
... More
50 Sqmm 3.5 core.
400
-
-
... More
70 Sqmm 3.5 core.
400
-
-
... More
95 Sqmm 3.5 core.
400
-
-
... More
120 Sqmm 3.5 core.
300
-
-
... More
150 Sqmm 3.5 core.
150
-
-
... More
185 Sqmm 3.5 core.
200
-
-
... More
240 Sqmm 3.5 core.
100
-
-
... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 35 Sqmm complete all as specified and as directed.
10
-
-
... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
12
-
-
... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and as directed.
5
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified and as directed.
Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m.
12
-
-
... More
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
Note : Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc shall be included in quoted rates.
190
-
-
... More
M&L for copper strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
Note : Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc shall be included in quoted rates.
40
-
-
... More
M&L for copper earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts, nut check nut and washers protected with and including 40 mm dia medium grade GI pipe, necessary excavation and earth work, magnesium sulphate (80 Kg) ), charcoal (4 Qtl) and common salt (4 Qtl) filling, watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover, GI funnel with test point, testing (all as shown in electrical plate No 5 and commissioning all as specified and as directed. Note : On testing, after completion, if the earth resistance below 1 Ohms is not obtained, earthing will rejuvenated at no extra cost till the desired earth resistance is obtined.
10
-
-
... More
M&L for laying GI tubing, light grade, 80 mm bore with all fittings as cable protection fixed on walls/along poles/ underpass/on ceiling or laid in floor complete all as specified and as directed.
50
-
-
... More
M&L for laying GI tubing, light grade, 100 mm bore with all fittings as cable protection fixed on walls/along poles/underpass/on ceiling on laid in floor complete all as specified and as directed.
40
-
-
... More
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in and ramming earth
or broken rubble mixed with earth around, in layers not
exceeding 25 cm in soft/loose soil complete all as specified and as directed.
116
-
-
... More
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.
25.06
-
-
... More
Supply only chain link mild steel galvanized fencing any size or type complete all as specified and as directed.
944.82
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed.
261
-
-
... More
Supply and fix mild steel section for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts for post and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc.or flat iron fillet (for securing wire mesh etc)including all necessary drilling bolting,using steel section of grade E-165 (Fe-290).complete as specified and as directed.
1614.7
-
-
... More
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long & dia of shank 5 mm to 10mm long complete as specified and as directed.
40
-
-
... More
M&L for preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed.
72.38
-
-
... More
Supply and fixing in replacement of MCCB 630Amp rating, (ICS=100% of ICU) 4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 50 KA complete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of MCCB 400Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA. complete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of MCCB 350 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA complete all as specified and as directed.
6
-
-
... More
Supply and fixing in replacement of MCCB 250 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
12
-
-
... More
Supply and fixing in replacement of MCCB 200 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
9
-
-
... More
Supply and fixing in replacement of MCCB 160 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
12
-
-
... More
Supply and fixing in replacement of MCCB 100 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
11
-
-
... More
Supply and fixing in replacement of MCCB 63 Amp rating, (Ics=100% Icu) 4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
8
-
-
... More
Supply and fixing in replacement of MCCB 250Amp rating, (Ics=100% Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
3
-
-
... More
Supply and fixing in replacement of MCCB 200Amp rating, (Ics=100% Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement of MCCB 160Amp rating, (Ics=100% Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
7
-
-
... More
Supply and fixing in replacement of MCCB 125Amp rating, (Ics=100% Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA. complete all as specified and as directed.
4
-
-
... More
Supply and fixing in replacement of MCCB 100Amp rating, (Ics=100% of Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
5
-
-
... More
Supply and fixing in replacement of MCCB 63Amp rating, (Ics=100% of Icu) 3-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
6
-
-
... More
Supply, installation, testing and commissioning of Bus Bar Chamber outdoor type made out of 1.6 mm CRCA steel sheet 8 Nos outgoing TPN 200 Amps Bus Bar rating including fixing on Wall/Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3mm, 750mm long including PCC 1;2:4 tyoe B-1 as in foundation of size 450 x 600 x 600mm for grouting and incommer and outgoing cable connections with suitable size of lugs complet all as specified and as directed.
6
-
-
... More
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 80 Amp to 100 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
12
-
-
... More
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 125 Amp to 200 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
15
-
-
... More
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 200 Amp to 400 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
12
-
-
... More
Supply and Fixing in replacement of spreader terminal link kit for MCCB in LT panel/Feeder pillar box suitable for rating 500 Amp to 630 Amp ,4 pole,50 HZ,AC complete all as specified and as directed.
4
-
-
Evaluation Notes How It Works ?