Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Solid Waste Management
Eprocure
Opening Date5 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670696_2Bid Award Id
ViewTender No
GE/W/LKO73 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for rendering 15mm thick on any faces of brick wall or concrete surface in CM 1:4 finished fair and even without using extra cement complete all as specified and directed.
.
100
-
-
... More
S&F for mild steel deformed bars or TMT bars 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
100
-
-
... More
S&F for mild steel deformed bars or TMT bars 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
5
-
-
... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar internal dia of pipe 150mm complete all as specified and directed.
200
-
-
... More
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar internal dia of pipe 200mm complete all as specified and directed.
100
-
-
... More
S & F DWC (Double wall corrugated ) 150 mm dia pipes manufactured as per IS 16098(part -2) having internal surface smooth and external corrugated surface of SN -4 stiffness laid and jointed complete all as specified and directed
200
-
-
... More
S & F DWC (Double wall corrugated ) 200 mm dia pipes manufactured as per IS 16098(part -2) having internal surface smooth and external corrugated surface of SN -4 stiffness laid and jointed all as per specified and directed.
100
-
-
... More
M & L for PCC 1 : 4 : 8 type D2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; internal dia of pipe 150mm complete all as specified and directed.
200
-
-
... More
M & L for PCC 1 : 4 : 8 type D2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; internal dia of pipe 200mm complete all as specified and directed.
100
-
-
... More
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5 m depth and getting out complete all as specified and directed.
180
-
-
... More
M & L for Plain Cement concrete Type D2 1:4:8 (40 mm graded stone aggregate) as in foundations, filling and mass and sloping floor concrete complete incldg demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)all as specified and directed
2
-
-
... More
M & L for Plain Cement concrete Type C2 1:3:6 (40 mm graded stone aggregate) as in as in surface channel , benching of mamhole/drain including necessary form work /mould etc complete incldg demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
0.5
-
-
... More
M & L for Plain Cement concrete Type B0 1:2:4 (12.5 mm graded stone aggregate) as in Copings, complete including demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
1.5
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
120
-
-
... More
Removal of excavated soil to a distance exc 250 but n. exc 500M and depositing where directed at a level not exc 1.5M above the starting point complete all as specified and directed.
60
-
-
... More
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, with clamp bore of pipe 110mm complete all as specified and as directed
100
-
-
... More
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, with clamp bore of pipe 75mm complete all as specified and as directed.
70
-
-
... More
S&F in repair PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
10
-
-
... More
S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
10
-
-
... More
S&F in repair PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
2
-
-
... More
S&F in repair PVC (SWR) vent cowl 75 mm bore complete all as specified and directed.
2
-
-
... More
S&F CI Spun pipe 100mm bore single socketed in any length or without ears with cement joints fixed to wall with clamp or laid in trenches or in floors including demolition and breaking up existing drain pipes complete all as specified and directed
10
-
-
... More
M & L for PCC 1 : 4 : 8 type D2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; internal dia of pipe 100mm complete all as specified and directed.
10
-
-
... More
S&F in repair 75mm bore CI sand cast soil waste and vent pipe in any length with or without ears with cement joints fixed to wall with clamp or laid in trenches or in floors complete all as specified and directed
Note : Excavation & earth work shall be measured and paid separately.
10
-
-
... More
Cutting into existing man holes for connection new drains internal dia of pipe 150 mm, making good to pipe and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) min cement concrete 1 : 2 : 4 type B1 smooth finished and reforming benching complete all as specified and directed.
5
-
-
... More
~ditto~ all as per item No. 28 above but 100mm internal dia of pipe complete all as specified and directed.
5
-
-
... More
Rectifying complaint of blockage of bathroom /kitchen/WHB/urinal /WC etc any pattern and make it fuctional. The blockage shall be cleaned all as specified and directed Note:-
(a) The contractor shall provide adequate labours and tools to rectify the complaints.
(b) The sludge obtained during rectifying the complaints shall be disposed of beyond the periphery of defence land.
(c) Penalties for delay will be applicable as per Particular Specification.
5000
-
-
... More
Rectifying complaint of blockage of Manholes depth not exc 1.0 mtr incl removing all sludge all as specified and directed Note:-
(a) The contractor shall provide adequate labours and tools to rectify the complaints.
(b) The sludge obtained during rectifying the complaints shall be disposed of beyond the periphery of defence land.
(c) Penalties for delay will be applicable as per Particular Specification.
320
-
-
... More
Rectifying complaint of blockage of Manholes depth exc 1.0 mtr and not exc 1.50 incl removing all sludge all as specified and directed Note:-
(a) The contractor shall provide adequate labours and tools to rectify the complaints.
(b) The sludge obtained during rectifying the complaints shall be disposed of beyond the periphery of defence land.
(c) Penalties for delay will be applicable as per Particular Specification.
200
-
-
... More
Rectifying complaint of blockage of sewage line 100 mm of any length & depth and make it fully fuctional incl removing all sludge complete all as specified and directed
300
-
-
... More
Rectifying complaint of blockage of sewage line 150 mm of any length & depth and make it fully fuctional incl removing all sludge complete all as specified and directed
400
-
-
... More
Cleaning of soak well using mechanical pumps diesel driven with fuel, operator and necessary excavation on half buried night soil and disposed of soak well water etc in pits including necessary excavation and earth work for pits for burrying the night soil etc in soft/loose soil complete all as specified and directed.
50
-
-
... More
Cleaning/desludging of existing septic tank of any capacity/sump well of any dia and depth incl taking out sludge in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc means of sewage sucking machine or by way of any other suitable means and removing the sludge outside MD land by any means , and making good the brick work, plaster etc complete all as specified and directed. Note: The sludge/burried soil etc taken out shall be stacked alongwith the septic tank, sump well etc. After 48 hours of the sludge taken out, measurement shall be taken as of the solid contents for the purpose of payment. The tenderer are advised take up this aspect in mind while quotating the rates. After taking measurements, the solid contents shall be disposed off outside the MD land/area
100
-
-
... More
Provison of Soakage wells including excavation, in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chanmber made of Bricks masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with bricks bats of size.2.4 m dia x 6.0 m complete all as specified and directed
1
-
-
... More
Provison of RCC Septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 Users complete all as specified and directed
1
-
-