Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date12 Sep 2024
Closing DateCancelled
Tender Amount₹ 9,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No - 1 here-in-before but repair & comprehensive maintenance of 40 to 62.5 KVA capacity DG sets

8

-

-

... More
All as per item No - 1 here-in-before but repair & comprehensive maintenance of 20 to 35 KVA capacity DG sets

6

-

-

... More
All as per item No - 1 here-in-before but repair & comprehensive maintenance of 7.5 KVA capacity DG sets ...ditto. (Note for Sl item No: 1 to 6 :- (i) Spares required/parts replaced shall be measured and paid seperately under respective items of this Schedule as supply only. (ii)The labour & fixing charges for the items replaced are deemed to be included in the rates quoted for above items.

1

-

-

... More
Supply only Air Filter inner and outer for Capacity 180 KVA DG Set

-

-

-

... More
(a) Air Filter inner and outer

1

-

-

... More
(b) Fuel Filter

1

-

-

... More
(c) Lubricating Oil Filter

1

-

-

... More
Supply only the following spare parts for 100 KVA

-

-

-

... More
(a) Air Filter inner and outer

1

-

-

... More
(b) Fuel Filter

1

-

-

... More
(c) Lubricating Oil Filter

1

-

-

... More
Supply only the following spare parts for 82.5 KVA

-

-

-

... More
(a) Air Filter inner and outer

3

-

-

... More
(b) Fuel Filter

3

-

-

... More
(c) Lubricating Oil Filter

3

-

-

... More
Supply only the following spare parts for 40 to 62.5 KVA

-

-

-

... More
(a) Air Filter inner and outer

8

-

-

... More
(b) Fuel Filter

8

-

-

... More
(c) Lubricating Oil Filter

8

-

-

... More
Supply only the following spare parts for 20 to 35 KVA

-

-

-

... More
(a) Air Filter inner and outer

6

-

-

... More
(b) Fuel Filter

6

-

-

... More
(c) Lubricating Oil Filter

6

-

-

... More
Supply only the following spare parts for 7.5 KVA

-

-

-

... More
(a) Air Filter inner and outer

1

-

-

... More
(b) Fuel Filter

1

-

-

... More
(c) Lubricating Oil Filter

1

-

-

... More
Dismantling and taking down radiator assy from engine of any capacity for repairs including de-scaling, brazing as necessitated to plug leakages and for transporting of the radiator of capacity 20-62.5 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning to the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts, washers etc; and testing complete all as directed.

6

-

-

... More
.....Ditto .... as above but of capacity 100-180 KVA and ...ditto....

1

-

-

... More
Dismantling and removing Fuel injection pump (FIP) from DG set of 20 to 35 KVA capacity for repairs including calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified & directed.

1

-

-

... More
All as per item above here-in-before but DG sets of for 40 to 62.5 KVA capacity

1

-

-

... More
S&F in replacement of Fuel Injection pump of DG sets of 20 to 35 KVA capacity

1

-

-

... More
S&F in replacement of Fuel Injection pump of DG sets of 40 to 62.5 KVA capacity

1

-

-

... More
M & L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings all as specified

10

-

-

... More
M&L in replacement of engine Oil Grade 20 W 40 complete all as specified and directed.

250

-

-

... More
M&L in replecement of flame proof asbestos rope of existing dia or of dia as approved by AGE (I) wrapped around the exhaust pipe in replacement complete all as specified and directed.

20

-

-

... More
S & F Self Starter 12 V DC suitable for DG Set 20 to 35 KVA complete all as specified and directed.

1

-

-

... More
S & F Self Starter 12 V DC suitable for DG Set 40 to 62.5 KVA complete all as specified and directed.

1

-

-

... More
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc and replacement of defective/unserviceable parts all as necessary to make the self starter functional and testing on completion NOTE : (i) Spares required/parts replaced shall be measured and paid seperately under respective items of this Schedule as supply only. (ii)The labour & fixing charges for the items replaced are deemed to be included in the rates quoted for above items.

6

-

-

... More
Supply only of Field coil of self starter 12 / 24 V complete all as specified and directed.

4

-

-

... More
Supply only of Armature of self starter 12 / 24 V complete all as specified and directed.

3

-

-

... More
Supply only of Clutch assembly of self starter 12 / 24 V complete all as specified and directed.

2

-

-

... More
Servicing of alternator of battery charging unit (12 Volt) including replacement of worn out parts such as bearings, winding, auto cut unit , mounting clamps etc complete to made functional to charge 12 V DC Battery

6

-

-

... More
Supply only of battery lead, copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable copper lugs/terminals at both ends all as specified and directed.

20

-

-

... More
Supply & fixing in replacement battery terminls of brass suitable for 12V, 180/92 AH battery all as specified and directed.

25

-

-

... More
S & F in replacement of Battery charger suitable for charging 1 x 12 V Battery with external wiring with 2 x 1.5 sqmm copper conductor not more than 5 mtr, complete all as specified and directed.

3

-

-

... More
S&F in replacement of unservieable Fan belts as per existing sample for 100/180 KVA capacity DG sets complete all as specified and directed.

3

-

-

... More
S&F in replacement of unservieable Fan belts for DG sets of 20 / 35 / 40/ 45/50/ 62.5 KVA capacity

6

-

-

... More
S&F in replacement of fuel flexible pipe, heavy duty with check nuts for DG sets of any make/capacity

6

-

-

... More
Dismantling of alternator assembly 20/ 35 / 40 / 45 /50/62.5 KVA DG Sets and taking out regulating transformer carefully and rewinding of regulating transformer including refitting and testing complete all as specified and directed.

1

-

-

... More
S&F in replacement of only oil pressure gauge as per sample complete all as specified and directed.

6

-

-

... More
S&F in replacement of only temperature gauge as per sample complete all as specified and directed.

6

-

-

... More
S&F in replacement of unserviceable water pump of DG sets of 20 /35 KVA capacity complete all as specified and directed.

3

-

-

... More
S&F in replacement of unserviceable water pump of DG sets of 40 / 62.5 KVA capacity complete all as specified and directed.

3

-

-

... More
S&F in replacement of Coolent additive concentrate pack of 10 Ltr suitable for DG Set complete all as specified and directed.

15

-

-

... More
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.

30

-

-

... More
S&F in replacement of alternator cutout assembly suitable for 82.5 - 180 KVA DG Set complete all as specified and directed.

3

-

-

... More
S&F in replacement of alternator cutout assembly suitable for 20/ 35 KVA D G set complete all as specified and directed.

3

-

-

... More
S&F in replacement of alternator cutout assembly suitable for 40/ 45 /50/62.5 KVA D G set complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement of Engine Safety unit suitable for 40 to 100 KVA DG Set complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of Thermostate suitable for 20 to 35 KVA DG Set complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement of Thermostate suitable for 40 to 62.5 KVA DG Set complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement of Thermostate suitable for 82.5 - 180 KVA DG Set complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement of alternator 12 Volt DC suitable for battery charging including mounting clamp, nut bolts washers etc complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement Battery 12V,180AH heavy duty complete suitable for DG sets complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement Battery 12V,125 AH heavy duty complete suitable for DG sets complete all as specified and directed.

2

-

-

... More
Supply and fix in replacement Battery 12V,92 AH heavy duty complete suitable for DG sets complete all as specified and directed.

2

-

-

... More
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed

6.3

-

-

... More
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm.complete all as specified and directed.

5.67

-

-

... More
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.

0.63

-

-

... More
Disconnection and dismantling of existing DG Set of capacity 50 KVA from the foundation including removing from the Site and carrying not more than 2 km complete all as specified and directed.

1

-

-

... More
Dismantling of 50 KVA-01 Nos DG SET of ENGINE Kirloskar for complete overhauling and calibration by taking out following unserviceable parts from the Engine for Repairing of Cylinder head,repairing of Turbo charger,repairing of injector and P.T pump repairing and replacement of Spares etc as necessary (its also includes dismantling of enginer stip opening, valve seat cutting and fixing of valve guide, fixing of cylinder liner, culinder block line bearing and threading of existing holes, repairs to cylinder head sleeves inlcuing fixing and testing) and re-assembling the same after necessary repair Works, Re-installation, Commissioning and Testing, complete all as specified and as directed.(Notes :- Spare parts will be measured and paid separately against relevant items)

1

-

-

... More
Supply Only follwing spare parts for 50.0 KVA DG Set suitable for Kirloskar Engine :-

-

-

-

... More
Cylinder liner

4

-

-

... More
Liner O ring

4

-

-

... More
Piston ring set

4

-

-

... More
CR bearing

8

-

-

... More
Main bearing

1

-

-

... More
Oil seal Rear

1

-

-

... More
Accy. oil seal

1

-

-

... More
Valve inlet

8

-

-

... More
Valve exhaust

8

-

-

... More
Valve seat

16

-

-

... More
Valve guide

16

-

-

... More
Injector sleeve

4

-

-

... More
Head gasket set

1

-

-

... More
Engine gasket set

1

-

-

... More
Radiator hose

4

-

-

... More
Cooler hose

2

-

-

... More
water pump

1

-

-

... More
Injector cup

4

-

-

... More
Thermostate

1

-

-

... More
screen filter

1

-

-

... More
Lube oil filter

1

-

-

... More
Diesel filter

1

-

-

... More
Bypass filter

1

-

-

... More
Air filter inner

1

-

-

... More
Air filter outer

1

-

-

... More
Demolition of cement concrete (unreinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.

2

-

-

... More
M & L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engr-In- Charge.

2

-

-

... More
Dismantling of asbestos cement sheets of any description (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.

15

-

-

... More
S & F Pre - Painted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by AGE(I) having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.

15

-

-

... More
M&L for PCC 1:2:4 Type C2( using 20mm graded stone aggregate) as in foundation for filling to fixed post or struts in position complete all as specified and directed

2

-

-

... More
M&L for PCC 1:3:6 Type C2( using 40mm graded stone aggregate) as in foundation for filling to fixed post or struts in position complete all as specified and directed

0.5

-

-

... More
Dismantling timber scantling in fillets, rails posts, rafters, purlins, etc. under 40 sqrcm in section un framed work complete all as specified and directed

105

-

-

... More
S&F in repair for Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples of size 25 mm x 25 mm complete all as specified and directed

40

-

-

... More
S & F MS joist channel , angle or Tee section MS tubes, flats square bars (Fe 410-W Gde E-250 Quality A) etc fixed indepently or framed or without connecting plates, (cut to ordinary lengths i.e. within 20mm of the length indicated) trusses etc any type framing including purlins and rafters etc complete all as specified and directed.

250

-

-

... More
Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed.

2

-

-

... More
M&L for brick work with sub class 'B' bricks old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed.

1.7

-

-

... More
All as per item above but except bricks complete all as specified and directed.

0.3

-

-

... More
M & L for 15mm thick rendering in cement mortar 1:4 on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement complete all as specified and directed.

20

-

-

... More
Supply, laying in trenches, jointing, testing, and commissioning of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor,11000 volts (E) grade, of size 70 Sqmm 3.5 core. confirming to IS-7098 Part-II including taking down of old cable complete all as specified and directed. Note: - Excavation, earth work, Brick protection and sand cushioning etc shall be measured and paid separately).

35

-

-

... More
Supply and lay sand with approved fine grade around cable in cushioning for protection of under ground cable complete all as specified and as directed

5

-

-

... More
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.

400

-

-

... More
S&F in replacement of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified.

5

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed.

4

-

-

... More
Fabrication, supply, installation, testing and commissioning in replacement of out door type LT Feeder pillar box size 0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs with heat strinkable PVC sleeving having RYB-B colour code , powder coated painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed Note :-MCCB and Change over switch will be measured and paid separately.)

1

-

-

... More
S & F MCCB 100 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides complete all as specified.

1

-

-

... More
S & F Offload Changeover switch 100 Amps 4 pole complete all as specified.

1

-

-

... More
Total amount with taxes in Figures

-

-

-

... More
Total amount with taxes in words

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.