Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Jul 2024
Closing Date5 Sep 2024
Tender Amount₹ 95,12,000
Costs
EMD
₹ 1,67,680Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664909_1Bid Award Id
ViewTender No
95287/S/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F 3mm thick polycarbonate corrugated sheet on roof incl all necessary fixing on roof. Complete all as specified and directed by Engr-in-charge.
40
-
-
Dismantling timber framed work scantlings 40 sq. cm and over in section, in any position
18
-
-
S&F Fe-290 (Gde E-165) MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, nut bolts, MS plate etc
20000
-
-
M&L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome
500
-
-
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)
171.33
-
-
M&L for 75mm for thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in sub-base complete all as specified and directed.
1100
-
-
M&L 25mm for thick Cement concrete type B-0, 1:2:4 (12.50mm graded aggregate) complete all as specified and directed.
1100
-
-
M&L for for machine cut kota stone slab flooring 20-25mm thick over 20mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
1100
-
-
M&L for 75mm for thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and directed.
160
-
-
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound type A complete all as specified and directed.
6.9
-
-
Demolition of Brickwork or stone/ boulder masonry, built in built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
15
-
-
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
15
-
-
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
1450
-
-
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick works or concrete surfaces, finished the surfaces even & smooth without using extra cement, complete all as specified and directed.
755
-
-
M&L for rendering 15mm thick in cement mortar (1:6) on other than fair faces of brick works or concrete surfaces, finished the surfaces even & smooth without using extra cement, complete all as specified and directed.
755
-
-
M&L for preparation of new plasterd surface of wall applying 1mm thick wall care putty and two coat of exterior grade weather proof acrylic emulsion paint (apex ultima). Complete all as specified and directed by Engr-in-charge.
755
-
-
Applying three coats of white wash on new wall surface including preparation of surface.
755
-
-
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado & pillar over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete
40
-
-
Taking down & Removing to Store Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames)
62
-
-
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
62
-
-
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
496
-
-
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane
62
-
-
S&F in repair Air turbine ventilator (model PSS 22) Non magenetic, tubine dia- 24 inches, throat dia- 22 inches, height- 15.5 inches, vanes/blades- SS 202 Grade, base ring- polypropylene, top plate-SS 202 grade, Rotation- win bearing ensure frictionless rotation even at low wind velocity, Centre shaft- MS electro zinc plated, inner arms- Polypropylene, Outer arms- Polypropylene, Number of bearing- 2, Bearing types-(6201, 6202 2RS self lubrication & sealed, Screws-steel finish screws. Complete all as specified and directed.
12
-
-
M&L for applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface.
50
-
-
Surface excavation Nexc (not exceeding) 30cm deep and averaging 15cm deep and geeting out in soft/loose soil.
400
-
-
M&L for hardcore (broken stone or boulders) of gauge nexc 63mm, deposited, spread and levelled in layers nexc 15cm thick, watered and rammed to a true surface complete all as specified and directed..
60
-
-
M&L for 100mm for thick PCC 1:3:6 type C-2 (using 40mm graded agg) as in sub-base complete all as specified and directed.
400
-
-
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
400
-
-
M&L for providing, cement concrete type B-1, 1:2:4 (20mm graded agg) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
2
-
-
Taking down carefully any type of battens or conduit point wiring with or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
145
-
-
Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, unsheathed, copper conductor cable in & including PVC concealed conduit of any size/dia complete with all accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth duly complete all as specified and directed for the followings for one light point controlled by one, one way switch 05 / 06 Amps.
85
-
-
All as per item no. 34 here-in-before but one fan point controlled by one, one way switch 05 / 06 Amps.
15
-
-
All as per item no. 34 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch.
25
-
-
All as per item no. 34 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch.
20
-
-
All as per serial item No 34 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board.
20
-
-
Supply and fix in repair switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
145
-
-
Supply and fix in repair socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed of maby Engr-in-Charge .
45
-
-
Supply & fixing of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed.
20
-
-
Supply and fix in repair switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
15
-
-
Supply and fixing steped type electronic fan regulator flush type on the existing sheet etc. AC, 230 volts, duly ISI marked with and including connector complete all as specified & directed by Engineer-in-Charge.
15
-
-
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed.
20
-
-
Supply and fix LED lamp 9/10 watt complete.
20
-
-
Supply and fix decorative LED Batten 20 Watt including rod complete aluminium housing integtrated type complete with all accessories and fixing material all as specified and directed by Engr-in-Charge. Make:- Havells equivalent in Crompton/ WIPRO/Surya
45
-
-
Supplying and fixing LED tube light fitting 9/10 watt surface mounted,with extruded polycarbonate , integrated lamp & driver , with opal diffuser and decorative end plates.complete with acessories all as specified and directed by Engr-in-Charge. Make Havells/CROMPTON/ Surya
2
-
-
Supply and installed LED security light fitting 1x45 Watt luminaries with pressure die cast aluminium housing comprising high power with PC cover with LED driver , IP-66 Protection and IK-07 Impact resistance complete IP 65 protection. : Make:- Havells ,Crompton / Bajaj / Phillips.
8
-
-
Supplying and fixing LED bulk head light fitting wall mounted with back lit LED 10 WATT watt, IP-66,complete with all acessories all as specified and directed by Engr-in-Charge Make- Havells / equivalent in Phillips/ Crompton.
8
-
-
Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
55
-
-
Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site to store for keeping in safe custody for reuse at site making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
140
-
-
Material and labour for sub main wiring with 2x6 Sqmm nominal cross sectional area (two single core cable of 6 Sqmm for Phase and neutral + o1 single core cable of 6.0 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing and taking down the old unserviceable submain wiring of ant type complete all as specified & directed.( Note - One meter of conduit along with 2x6.0 Sqmm wire and one 6.0 sqmm earth wire shall be measured as one length). Make- Plaza/Grandlay/HPL
140
-
-
Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
7
-
-
Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision for four pole isolator/mcb as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as directed. Make ABB/ Havells/ Legrand/ Schneider/Indoasian
2
-
-
Taking down unsv distribution board of any type/size and S&F fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces and taking down the old distribution board of any type complete all as directed Make - ABB/ Legrand/ Schneider/Indosasian
5
-
-
Supply and fixing MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed. Make C&S / Legrand ABB
35
-
-
Supply & fixing MCB, DP (Double Pole), AC, 240 volts, B series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed. Make C&S /Legrad / ABB
8
-
-
Taking down unsv cable of any type/size and S&F (in repair) , laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 3.5 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed.
80
-
-
Supply / laying and fixing 40mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed.
6
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft / loose soil and gating out in soft / loose soil complete all as specified and directed.
7.2
-
-
M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed by Engr-in-Charge.
4.32
-
-
Material and labour for contineous brick edging with width equal to the depth of the brick of whole sub class 'B' bricks laid on edge complete all as specified and directed.
0.48
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft / loose soil complete all as specified and directed.
1.5
-
-
Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed.
5
-
-
Material and labour for earthing with galvanised steel earth plate electrided 600 X 600 X 6 mm thick buried in ground (earth pit not less than 2.25 mtr depth below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth lead wire 4.0 mm dia by means of bolts nuts chek nuts and washers of galvanized iron or steel earth lead wire protected by and including 15 mm dia GI pipe medium grade pipe for protection and 20 mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work as in soft/loose soil, concrete pit in PCC (1:3:6) type c1, pre cast RCC 1:1:5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100 mm CC both way and 2 No, lifting handle made of 12mm dia TMT bar and set in cement mortor (1:4), funnel wire nesh, char-coal or coke and salt in alternate layer, testing etc complete all as specifide in electrical plate No. 3 of SSR Pt-1 all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost.
(ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5 m is included in the rate quoted for this item.
4
-
-
Supply and installed LED Flood light 50 watt die cast aluminium housing comprising high power including all needed accessories to fix it on wall/Tree/pole.. : Make:- Havells Model No- JETA QUANTO PLUS or equivalent Crompton/ Phillips/SURYA/Bajaj
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements