Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Soon5 Dec 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L PCC 1:2:4, type B0 using 12.5 mm graded stone aggregate as in roof kerbs / benching / coping and roof padding over roof surfaces etc rounded or chamfered on edges complete all as specified and as directed.

1

-

-

... More
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface including finishing the surface even and smooth without using extra cement including taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and as directed.

380

-

-

... More
M&L for glazed ceramic coloured tiles of size 350 x450mmx 7mm or 450x 350x 7 mm thick in walls etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles as in skirting/dados over 10mm thick rendering in cm 1:4 including dismantling wall tiling including cement mortar bedding, removing and rubbish off the premises etc complete all as specified.

80

-

-

... More
M&L for 7-8mm thick Non skid coloured ceramic floor tiles, shade as approved area of each tile exc 0.06 sqm but not exceeding 0.11 sqm set on 15mm thick in neat cement screed in cm (1:6) and pointed incl white or colour cement to match including dismantling floor, hearth tiling including cement mortar bedding , removing and rubbish off the premises etc complete all as specified and as directed.

35

-

-

... More
M& L for Vitrified tiles double charged 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6, including dismantling floor, hearth or wall tiling including cement mortar bedding , removing and rubbish off the premises etc complete all as specified and as directed.

110

-

-

... More
Ditto- All as per above item No-08 above but on vertical surfaces over and including 10mm thick screed plaster in CM 1:4 , complete all as specified and as directed.

15

-

-

... More
Supply and fixing of 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing making good and complete all as specified and as directed.

60

-

-

... More
Supply and fixing of 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing and making good complete all as specified and as directed.

40

-

-

... More
S&F in repair bib taps 15mm bore, half/quarter turn, fancy type, long body, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including all accessories complete all as specified and as directed.

40

-

-

... More
S&F in repair of CP alloy chromium plated angle valve/ two way angle valve long body for 15 mm bore pipe with capstan head long screwed shank including CP cover plate fancy type all as specified and directed

60

-

-

... More
S&F in repair 15 mm bore CP brass Central Hole Basin/ kitchen mixture fixed to GI pipe.complete all as specified and as directed

4

-

-

... More
S&F in repair single lever wall mixture 3-in-1 system with provision for overhead shower with 115 mm long bend pipe, connecting legs and wall flange(without over head shower) screwed down for 15 mm bore GI pipe complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC low level white flushing cistern valveless syphonic action dual type ISI Mark with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend complete all as specified and as directed.

20

-

-

... More
S&F in repair hand shower (health faucet), superior quality, round shape, single flow, brass chromium plated, with 1m long flexible pipe with wall hook bracket etc. and all fittings for EWC complete all as specified and as directed.

120

-

-

... More
S&F in repair 5 mm thick sheet glass corner shelf assembly, fancy type, sheet glass shelf of size 250x250mm, with CP bracket guard and railing, fixed to wall with PVC gully and CP brass screws complete all as specified and as directed.

10

-

-

... More
S&F in repair 5 mm thick sheet glass shelf assembly, fancy type, sheet glass shelf of size 600mm long and 120mm wide with CP bracket guard and railing, fixed to wall with PVC gully and CP brass screws complete all as specified and as directed.

10

-

-

... More
S & F in repair Brass spindle for mixer/wall mixer of any type or pattern complete all as specified and as directed.

320

-

-

... More
S&F in repair 20 mm bore gun metal globe or gate valves with iron wheet head screwed both ends for iron pipe including testing complete all as specified and as directed.

20

-

-

... More
S & F in repair of plastic water closet seat cover (any size/ shape) closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.

150

-

-

... More
S&F in repair CP brass tubular towel rail 20mm dia, any type, 600mm long between flanges, superior quality, fancy type, fixed to wall with PVC gully and CP brass screws complete all as specified and as directed.

55

-

-

... More
Supply and fixed in repair 600x450mm beveled edges mirror of selected quality mounted on 4mm thick AC building board/ PVC frame or 6mm thick ply fixed to wall with rowl plug and screws complete all as specified and as directed.

80

-

-

... More
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and as directed.

110

-

-

... More
S & F in repair of Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as specified and as directed.

70

-

-

... More
S&F 500 Litre capacity rotational moulded polyethylene water storage tanks white colour double layered (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe including dismantling PVC water tank complete all as specified and as directed.

10

-

-

... More
Supply & Fixing in repair CP Brass shower rose fancy type 125mm thick with or without swivel joints any size including fixed to steel pipe or union complete all as specified and as directed.

70

-

-

... More
S&F in repair kitchen sink with drainage board made of stainless steel 1mm thick with plugs, washers, waste coupling and waste pipe, including bedding in cement mortar 1:3 to dwarf wall or fixing cantilever brackets and connecting union to waste pipe, overall size 915mmx460mm with bowl size 410x330x160mm complete all as specified and as directed.

5

-

-

... More
Supply & Fixing in repair sink without drainage board size 560x410x200 mm made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes pipe & coupling etc incl bedding in cement mortar to dwarf wall or cantilever brackets and connection union to pipe complete all as specified and as directed.

4

-

-

... More
S & F in repair stainless steel kitchen plate rack made out of 1.00 mm thick stainless steel of size 900x750x250 mm including screws and weight not less than 5.00 Kg complete all as specified and as directed.

30

-

-

... More
S&F in repair float ball 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and as directed.

160

-

-

... More
S&F in replacement of WPC cabinet and cupboard in required sizes at site made out of 18mm thick one side decorative lamination & other side balancing lamination sheet consisting of carcass 18mm thick WPC sheet & provision of shutters made out of 18 mm thick one side decorative laminated WPC sheet density not less than 600 kg/ Cum all required brackets SS screws etc. The panels shall be fabricated using adhesive and screws where ever required. All the edges shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent finish including all necessary fittings and required knobs in each shutters as per site requirement and as per make and specification mentioned as per drawing and complete all as specified and as directed.

45

-

-

... More
S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and as directed.

40

-

-

... More
S & F Continuous (piano) hinges, mild steel, bright finished or electro galvanised, with width of flap 30mm when open, and fixed with screws complete all as specified and as directed.

20

-

-

... More
S & F magnet ball catcher with 8 mm dia steel bal and brass body and strike plate for cup board shutters complete all as specified and as directed.

100

-

-

... More
S&F 100 mm long aluminum anodised, hasp and staple, safety type, with mild steel hinge pin including bolts to hinge plate and fixed with screws complete all as specified and as directed.

60

-

-

... More
S&F 100mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and as directed.

110

-

-

... More
S & F in repair of Continuous (piano) hinges, mild steel, bright finished or electro galvanised, with width of flap 30mm when open, and fixed with screws complete all as specified and as directed.

20

-

-

... More
S & F in repair of magnet ball catcher with 8 mm dia steel bal and brass body and strike plate for cup board shutters complete all as specified and as directed.

120

-

-

... More
S&F in repair of 100 mm long aluminum anodised, hasp and staple, safety type, with mild steel hinge pin including bolts to hinge plate and fixed with screws complete all as specified and as directed.

120

-

-

... More
S&F in repair of 100mm size extruded aluminum alloy handles, fabricated type, anodised complete all as specified and as directed.

180

-

-

... More
S&F in repair 25mm dia stainless steel curtain rod (weight not less than 0.15 Kg / RM) superior quality with end brackets and end knobs and fixed to wall with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and as directed.

350

-

-

... More
S&F in repairs of 0.36 mm dia stainless steel wire cloth (G-304) with average width of aperature 1.40 mm and fixed with stainless steel wire staples or moulded beading (change wiremesh in iron window upto IIIrd floors) complete all as specified and as directed.

110

-

-

... More
S&F in repair two(double) legged floor door stopper of aluminum body & tougues anodised with hard drawn steel spring fixed in floor with 140mm long cover plate complete all as specified and as directed.

45

-

-

... More
S&F 3 mm thick sheet glass ordinary quality and fixing with wooden beads or oil putty and provsion of glazing pins in squares not exceeding 0.50 Sqm in each pane any floor including hacking out old broken glass of any description and thickness from wooden/steel frames fixed with wooden beads/putty (Window glass change upto IIIrd floors) and complete all as specified and as directed.

75

-

-

... More
M&L for preparation of old plastered or unplastered surface of ceiling and applying one coat of white wash complete all as specified and as directed.

1000

-

-

... More
M&L for preparation of old plastered or unplastered surface of ceiling and applying one coat of oil bound distemper complete all as specified and as directed.

1000

-

-

... More
M&L for preparation of old painted surface of wood and wood based material of any description area exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.

1500

-

-

... More
M&L for preparing old painted surface of steel/iron of any description area exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.

1500

-

-

... More
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over and including putty complete all as specified and as directed.

380

-

-

... More
M&L for one coat of oil bound distemper on old plastered surfaces of wall including preparation of loose plaster surfaces with one coat of putty complete all as specified and as directed.

2000

-

-

... More
M&L for preparation of old surface of walls and applying one coat of cement based paint complete all as specified and as directed.

3000

-

-

... More
M&L for preparation of old surface of walls and applying subsequent coats of cement based paint complete all as specified and as directed.

1000

-

-

... More
Taking down chowkhat frame with shutter (without taking out shutter from the frame) n.exc 1.50 Sqm and removing from site complete all as specified and as directed.

30

-

-

... More
Taking down chowkhat frame with shutter (without taking out shutter from the frame)exc 1.50 Sqm and n.exc.4.00 sqm and removing from site complete all as specified and as directed.

35

-

-

... More
M & L 30 mm thick Factory made solid WPC (Wood plastic Composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture including SS wire mesh (G-304) 0.36 mm minimum dia of wire and average width of aperture 1.4 mm shall be fixed with 15 x 15 square tube in side rails with screwing 8 x 28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density shall be as per manufacture instruction complete all as specified and complete all as specified and as directed.

25

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm mprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) complete all as specified and as directed. Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made

75

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm mprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 mm2 and resistance to spread of flame of Class A category with property of being mite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).complete all as specified and as directed. Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made

100

-

-

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid both side decorative type (Laminated both side) flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and as directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)

45

-

-

... More
Providing & fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick "D" Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyster paint of 12-16 microns thick and back coated with 5-7 microns thick alkyed backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48x25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade) 0.36 mm minimum dia of wire and average width of aperture 1.4 mm. Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10 mm square guard bars with 6"(152.4mm) pitch, complete for finished item of work including of all taxes, design complete all as specified and as directed.

45

-

-

... More
S & F of Stainless steel ISI Mark Butt hinges 100mm size complete all as specified and as directed.

150

-

-

... More
S & F of 200mm long MS Chromium plated barrel tower bolts of extructed section complete all as specified and as directed.

85

-

-

... More
Supply & fix MS ordinary pattern spring "plate type" including roller & roller plate complete all as specified and as directed.

15

-

-

... More
S&F of MS Chromium plated sliding door bolt 250mm long with hasp and staple (bolt type) and fixing clip of sheet and cast in extruded section and fixing bolts and sliding bolt of extruded section complete all as specified and as directed.

15

-

-

... More
S & F of 200mm size extruded aluminium alloy powder coated handles (As per sample kept in sample room) fancy type, fabricated type, anodised complete all as specified and as directed.

110

-

-

... More
S & F in repair of stainless steel ISI Mark Butt hinges 100mm size complete all as specified and as directed.

110

-

-

... More
S & F in repair of stainless steel ISI Mark Butt hinges 75mm size complete all as specified and as directed.

10

-

-

... More
S & F in repair of 200mm long MS Cromium plated barrel tower bolts of extructed section complete all as specified and as directed.

60

-

-

... More
S & F in repair of 150mm long MS Cromium plated barrel tower bolts of extructed section complete all as specified and as directed.

80

-

-

... More
Supply& fix in repair of MS ordinary pattern spring "plate type" including roller & roller plate complete all as specified and as directed.

20

-

-

... More
S&F in repair of MS Chromium plated sliding door bolt 200mm long with hasp and staple (bolt type) and fixing clip of sheet and cast in extruded section and fixing bolts and sliding bolt of extruded section complete all as specified and as directed.

60

-

-

... More
S&F in repair of MS Cromium plated sliding door bolt 250mm long with hasp and staple (bolt type) and fixing clip of sheet and cast in extruded section and fixing bolts and sliding bolt of extruded section complete all as specified and as directed.

55

-

-

... More
S & F in repair of 125mm size Extruded aluminium alloy powder coated handles (As per sample kept in sample room) fancy type, fabricated type, anodised complete all as specified and as directed.

120

-

-

... More
S & F in repair of 150mm size Extruded aluminium alloy powder coated handles (As per sample kept in sample room) fancy type, fabricated type, anodised complete all as specified and as directed.

80

-

-

... More
Repairing/ easing to steel window side hung shutter including fixing of left or right MS handle, casement stay 300 mm long , MS tower bolt and welding wherever required complete all as specified and as directed.

80

-

-

... More
M&L mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.

250

-

-

... More
Repairing/ easing to handle, tower bolts, hinges, sliding bolt and like this in door of any type n exc 2 Sqm including necessary nails and other like complete all as specified and as directed.

110

-

-

... More
S&F 'E' board of size 600x600x4mm thick white prelaminated sett embosed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be poweder coated white. The frame work shall comprise of main runner made from 0.33 mm thick GS sheet and of size 24x32x300mm abd soaced at 1200mm centers securely fixed to be structural soffts by approved hangers at 1200 mm maximum centrers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug level and justers and screws etc. The last hanger at the end of each main runner shall not be grater than 450mm from adjacent wall, Flush fitting of 1200mm long cross tee (with double stiching) to be interlocked between main runners at 600mm center to from 1200x600mm modules cross tee longer than 600mm to be supported independtly. 600x600mm dodules to be formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee, perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour including dismantling of old false ceiling and boarding of any description and all as per manufacture insturction.

175

-

-

... More
S&F in repair of CP grating 125mm dia with waste hole (Minimium weight 40 grams) complete all as specified and directed.

70

-

-

... More
S&F in repair of CP grating 125mm dia without waste hole (Minimium weight 40 grams) complete all as specified and directed.

70

-

-

... More
S & F of CI spun Hubless Pipes 100 mm bore single socketed in any length in trenches or in floors with shield coupling SS (304) with EPDM rubber gasket but fixed to walls including taking down old pipe complete all as specified and as directed

115

-

-

... More
S & F of CI spun Hubless Pipes 75 mm bore single socketed in any length in trenches or in floors with shield coupling SS (304) with EPDM rubber gasket but fixed to walls including taking down old pipe complete all as specified and as directed

80

-

-

... More
S & F in repair of CI spun Hubless bends any radius 100 mm size complete all as specified and as directed.

150

-

-

... More
S & F in repair of CI spun Hubless bends any radius 75 mm size complete all as specified and as directed.

70

-

-

... More
M & L in repair of 100 mm dia CI any type of trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as speciifed and directed.

55

-

-

... More
M & L of repair 75 mm dia CI any type of trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as speciifed and directed.

38

-

-

... More
S & F of 100mm bore pipe stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays or hold fast(brass/ stainless steel), including bolts and nuts and securing ends of stays to wall or roof any type complete all as specified and as directed.

45

-

-

... More
Rectifying complaints of blockage of bathroom / kitchen / WHB / urinals / WCs etc of any pattern and make it fully functional. The blockage shall be cleared all as specified and directed. Note:- (a) The contractor shall provide adequate labours and tools to rectify the complaints. (b) The sludge obtained during rectifying the complaints shall be disposed of beyond the periphery of defence land. (c) Penalties for delay will be applicable as per Particular Specification.

1200

-

-

... More
Rectifying complaints blockage of manholes depth not exc 1.00 mtr incl removing all sludge as specified and directed. Note:- (a) The contractor shall provide adequate labours and tools to rectify the complaints. (b) The sludge obtained during rectifying the complaints shall be disposed of beyond the periphery of defence land. (c) Penalties for delay will be applicable as per Particular Specification.

250

-

-

... More
Rectifying complaints blockage of manholes depth exc 1.00 mtr but not exc 1.50 mtr incl removing all sludge as specified and directed Note:- (a) The contractor shall provide adequate labours and tools to rectify the complaints. (b) The sludge obtained during rectifying the complaints shall be disposed off beyond the periphery of defence land. (c) Penalties for delay will be applicable as per Particular Specification.

42

-

-

... More
Rectifying complaints of blockage of sewage lines of 100 mm dia of any length & depth and make it fully functional complete all as specified and as directed.

150

-

-

... More
Rectifying complaints of blockage of sewage lines of 150 mm dia of any length & depth and make it fully functional complete all as specified and as directed.

80

-

-

... More
Cleaning of soak well using mechanical pumps diesel driven with fuel, operator and necessary excavation on half buried night soil and disposed off soak well water etc in pits including necessary excavation and earth work for pits for burrying the night soil etc in soft/loose soil complete all as specified and as directed.

60

-

-

... More
Cleaning/desludging of existing septic tank of any capacity/sump well of any dia and depth incl taking out sludge in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc means of sewage sucking machine or by way of any other suitable means and removing the sludge outside MD land by any means complete all as specified and as directed. Note: The sludge/burried soil etc taken out shall be stacked alongwith the septic tank, sump well etc. After 48 hours of the sludge taken out, measurement shall be taken as of the solid contents for the purpose of payment. The tenderer are advised take up this aspect in mind while quotating the rates. After taking measurements, the solid contents shall be disposed off outside the MD land/area

80

-

-

... More
M&L for Providing factory made cover full floor mediun duty weight Square/ rectangular (size 500mm x 900mm) thickness not less than 75mm set in CM 1:6, as in cover slabs (for manhole, drains etc) with plain fair faces, with angle iron frame alround complete all as specified and as directed.

160

-

-

... More
M&L for providing precast RCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone agg as in cover slab for man holes, drains, soak well etc and similar articles etc, set in CM 1:4 with plain faces including chamfered weathering throating etc incl necessary form work and including demolition of old reinforced concrete of any description in any postion not otherwise specifically provided for complete all as specified and as directed.

2

-

-

... More
S&F for mild steel deformed bars or TMT bars 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.

90

-

-

... More
M & L in repair 100 mm dia CI any type of trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as speciifed and directed.

12

-

-

... More
S & F of 100mm bore pipe stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays or hold fast(brass/ stainless steel), including bolts and nuts and securing ends of stays to wall or roof any type complete all as specified and as directed.

115

-

-

... More
Taking down carefully old unserviceble existing single core wiring copper/aluminium for taking credit of retrieved material and making good disturbed surfaces of walls, floors complete all as specified and as directed.

172

-

-

... More
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.5 sqmm nominal cross sectional area single core drawn into existing conduit, including pressed steel concealed terminal switch boxes not less than 1.5 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.5 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and as directed. (a) One light/Fan point controlled by one, one way 5 Amp, one switch.

101

-

-

... More
One bell/ buzzer point controlled by one bell push complete all as specified and as directed.

5

-

-

... More
One 5 pin 5 Amp socket outlet point on same board complete all as specified and as directed.

15

-

-

... More
All as per Item No 106 above but One 5 pin 5 Amp socket outlet point on an independent board complete all as specified and as directed.

34

-

-

... More
All as per Item No 106 above but for one 6 pin 15/16 Amp socket outlet point on an independent board with cables of size 2.5 sqmm and one green colour earth cable of size 2.5 sqmm complete all as specified and as directed.

17

-

-

... More
S&F Switch piano flush button single pole one way 6 Amp 240 volt complete all as specified and as directed.

150

-

-

... More
S&F Switch socket combination 3 Pin 16 A flush type complete all as specified and as directed.

17

-

-

... More
S&F Socket outlet flush type 5 pin 6 Amps 240 volts complete all as specified and as directed.

49

-

-

... More
S&F in repair ceiling rose surface bakelite three terminal complete all as specified and as directed.

39

-

-

... More
S&F in repair angle type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.

32

-

-

... More
S&F bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed.

5

-

-

... More
S&F fan regulator electronic step type for ceiling fan fixed, in existing board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and as directed.

17

-

-

... More
S&F in replacement switch piano flush button single pole one way 6 Amp 240 volt complete all as specified and as directed.

1100

-

-

... More
S&F in replacement switch piano flush button single pole two way 6 Amp 240 volt complete all as specified and as directed.

50

-

-

... More
S&F in replacement switch piano flush button single pole one way 16 Amps 240 volt complete all as specified and as directed.

300

-

-

... More
S&F in replacement socket outlet flush type multipurpose 2 in 1, 3 pin 6 and 16 Amp, 230 volts complete all as specified and as directed.

300

-

-

... More
S&F in replacement socket outlet flush type 5 pin 6 Amps 240 volts complete all as specified and as directed.

350

-

-

... More
S&F in replacement Switch socket combination 2 in 1, 3 Pin 6 A flush type complete all as specified and as directed.

200

-

-

... More
S&F in replacement ceiling rose surface bakelite three terminal complete all as specified and as directed.

80

-

-

... More
S&F in replacement bell push single pole one way 5 Amp, 240 volt fuesh type complete all as specified and as directed.

50

-

-

... More
S&F in replacement angle type holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.

200

-

-

... More
S&F in replacement fan regulator electronic step type for ceiling fan fixed, in existing board and connecting as directed, after dismantling and removing unserviceable regulator complete all as specified and as directed.

80

-

-

... More
S&F in replacement call bell AC single pole 240 volt ding dong Type complete all as specified and as directed.

30

-

-

... More
S&F in replacement bulk head light fitting made from cast aluminium body with heat resistance pressure die cast housing, IP-65 and IK 08 protection cover suitable for bulk head fitting integrated type 7/10 W LED, 6500K , 100 lumens/watt including inbuilt electronic driver complete all as specified and as directed.

5

-

-

... More
S&F in replacement wall/surface mounting luminaires (Mirror Light) integrated LED Batten( 2 feet) 8/10 W, 6500 K, 230V , minimum 120 lumens/watt,with extruded aluminium housing & integrated electronic driver complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrngements complete all as specified and as directed.

100

-

-

... More
S&F in replacement wall/surface mounting luminaires integrated LED Batten 16/20 W, 6500 K,120 lumens/watt , 230V with extruded Aluminium housing 4 feet long with frosted PMMA/PC diffuser & integrated electronic driver, 25k burning hours, 2.5 KV surge protection complete including Electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements complete all as specified and as directed.

150

-

-

... More
S&F in replacement Decorative wall light fixture made up of Metal base, synthetic white in colour and square/round metal base with bend pipe and glass globe with nickel finish, ( B-22/E27 base), with 01 No. 7/9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connecting arrangements complete all as specified and as directed.

52

-

-

... More
S&F in replacement LED Building security light 20/25 Watt with high power LED source (100 lumen/watt) PDC housing, IP66 and IK 07 with 4 KV inbuilt surge protection ,minimum 50000 burning hours hv cutoff@325/440 volt protection for 8 hours including Electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and as directed.

5

-

-

... More
S&F in replacement LED lamp 9 watt, complete all as specified and as directed.

960

-

-

... More
S&F in replacement FTL fittings with decorative LED batten made up of aluminium casting 18/20 W of size complete standard fittings and fixtures including fixing on walls/roofs/ through MS downrod suspended type with fitting arrangement including neccessary elect connection from ceiling rose to luminaries with suitable size PVC cord complete all as specified and as directed.

50

-

-

... More
S&F in replacement Material glass led tube ,voltage range 220-240v-50hz ,cct 6500k,lumen ,wattage 16/20 W surge 2.5kv ,CRI 80 POWER FACTOR _0.9 ,BURING HOURS 25K HOURS 120 L/W ,6000 K with high efficency, with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as specified and as directed.

450

-

-

... More
S&F in replacement for 1.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.

360

-

-

... More
S&F in replacement for 2.5 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.

270

-

-

... More
S&F in replacement for 4.0 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.

180

-

-

... More
S&F in replacement for 6.0 sqmm single core copper,multistandard PVC insulated (FRLS) unsheathed, cable 1100 volts grade complete all as specified and as directed.

60

-

-

... More
S&F in replacement three core PVC insulated FRLSH sheathed cable with 1.5 sqmm stranded copper conductor complete all as specified and as directed.

100

-

-

... More
S&F in replacement sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and as directed.

1

-

-

... More
S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and as directed.

8

-

-

... More
S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and as directed.

2

-

-

... More
S&F in replacement MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.

100

-

-

... More
S&F in replacement MCB, single pole & neutral 32/40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.

25

-

-

... More
S&F in replacement MCB, triple pole & neutral, 63 to 100 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and as directed.

10

-

-

... More
S&F in replacement modular type AC box with socket plug top and MCBs with two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.

20

-

-

... More
S&F in replacement MCCB 125 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and as directed.

1

-

-

... More
M&L for Submain wiring with two single core PVC insulated cable with 4.0 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of walls/ceiling complete all as specified and as directed. (Note - PVC Conduit and accessories shall be deemed to be included in the quoted rate)

260

-

-

... More
S&F PVC casing and caping, 20 mm wide complete all as specified and as directed

80

-

-

... More
S&F in replacement 5A PVC gang box fitted with 5A switch socket combination, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.

20

-

-

... More
S&F in replacement 15A PVC gang box fitted with 15A switch socket combination, 230 Volts complete with pvc gitties and screws complete all as specified and as directed.

30

-

-

... More
S&F in replacement rectangular laminated hylum sheet top cover for switch sockets of size' (125mmx125mmx3mm) complete all as specified and as directed.

10

-

-

... More
Same as item 152 here in before but (200mmx125mmx3mm) complete all as specified and as directed.

10

-

-

... More
Same as item 152 here in before but (225mmx275mmx3mm) complete all as specified and as directed.

10

-

-

... More
Taking down and refixing and Comprehensive repair/maintenance of storage type electric water heater (geyser) of capacity 25/50 litres, vertical or horizontal type comprising of the following: (a) Opening or dismantling the storage tank, taking down, de-scaling, brushing and thoroughly cleaning. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and replacing of washers/ gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of Geyser and power point. (d) Checking and re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydrochloric acid or clear pedette solution. (f) Checking of indicator lamp for it proper serviceability. (g) Re-assembling the Geyser and re-install at same position and testing complete all as specified and as directed. NOTE: Unserviceable Parts/ components of electric water heater shall be replaced by the contractor. (ii) Supply of new parts/components shall be measured and paid separately under respective item of schedule.

50

-

-

... More
S&F in replacement thermostat of Type EST 11/20A, 240 Volt of ISI marked approved make complete all as specified and as directed.

60

-

-

... More
S&F in replacement thermostat of Type EST 7/15A, 240 Volt of ISI marked approved make complete all as specified and as directed.

70

-

-

... More
S&F in replacement heating element of capacity 1.5/2 KW, AC 240 volts, suitable for storage type electric water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartrige type), ISI marked complete all as specified and as directed.

120

-

-

... More
S&F in replacement copper syphon (door) assembly suitable for geyser of capacity 25/50 litres of any type as required complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket complete all as specified and as directed.

2

-

-

... More
S&F in replacement polycorbonate 3-pin, 16 amps Plug top, white complete all as specified and as directed.

20

-

-

... More
S&F in replacement indicating LED lamp, Neon type, 240 volt AC suitable for 25/50 ltrs capacity geysers complete all as specified and as directed.

15

-

-

... More
S&F in replacement safety valve suitable for 25/50 litres capacity geyser complete all as specified and as directed.

5

-

-

... More
S&F in replacement sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.

40

-

-

... More
M&L for tracing and arresting of leakage in storage tank of 25/50 ltrs capacity geyser by brazing and soldering at leakage point and testing on completion complete all as specified and as directed.

10

-

-

... More
S&F in replacement 450 mm long steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water and Cold Water Supply and fixed complete all as specified and as directed.

75

-

-

... More
S&F in replacement non return valve of cast copper alloy suitable for 15 mm bore pipe and fixed complete all as specified and as directed.

5

-

-

... More
S&F in replacement stainless steel inner tank of capacity 25/50 litres geyser, vertical or horizontal type complete all as specified and as directed.

3

-

-

... More
Taking down carefully and comprehensive maintenance of ceiling fan/Exhaust fan of any size/sweep and make after disconnecting all electrical connection, detaching the blades, removing fan with blades to workshop, opening and cleaning of fan, segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and provn of replacement of two nos split pins, one connection block, canopy and one rubber reel complete all as specified and as directed. NOTE: (i) Rewinding work of armature (if any) shall be measured and paid separately. (ii) Replacement of new spare parts with old unserviceable parts other than connector, split pins, connection block and rubber reel and shall be measured and paid separately under respective item of schedule. (iii) Labour cost for replacement of spare parts shall deemed to be inclusive in quoted rate.

75

-

-

... More
M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for ceiling/exhaust/others type fan of any size/sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and as directed. Note: The ceiling fan winding work will be done in AGE E/M Yard.

100

-

-

... More
S&F in replacement new metal bush made out of Gun metal/ Brass of same size suitable for ceiling fan, wall mounted fan and exhaust fan complete all as specified and as directed.

20

-

-

... More
S&F in replacement roter shaft of ceiling fan, exhaust fan, wall fan of any capacity, make and type complete all as specified and as directed.

20

-

-

... More
S&F in replacement ball bearings No. 6201 and 6202 suitable for fan complete all as specified and as directed.

20

-

-

... More
S&F in replacement ball bearings No. 6203 and 6204 suitable for fan complete all as specified and as directed.

20

-

-

... More
S&F in replacement capacitor 1.5 Mfd, 230 Volts, 50Hz complete all as specified and as directed.

140

-

-

... More
S&F in replacement capacitor 2.5 Mfd, 230 Volts, 50Hz complete all as specified and as directed.

250

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.