Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date25 Mar 2024
Closing Date29 Jun 2024
Tender Amount₹ 11,99,56,000
Costs
EMD
₹ 9,25,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_647809_1Tender No
CELZ/KAN/T-32 OF 2022-23Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Total amount of Sch 'A' Part IV (Internal Electrification)
1
-
2163917.68
Total amount of Sch 'A' Part V (Foot Path)
1
-
390530.92
Total amount of Sch 'A' Part VI (Area Drainage)
1
-
375299.98
Total amount of Sch 'A' Part VII (Sewage Disposal)
1
-
242669.75
Total amount of Sch 'A' Part VIII (Security wall & Gate )
1
-
2561209.95
Total amount of Sch 'A' Part IX (External Water Supply )
1
-
266511.32
Total amount of Sch 'A' Part X (External Electrification )
1
-
1378981.8
Total amount of Sch 'A' Part XI (Hot water supply)
1
-
514388.28
Total amount of Sch 'A' Part XII (Rain Water Harvesting )
1
-
182516.89
Total amount of Sch 'A' Part XIII (Demolition/Dismantling )
1
-
179488.95
Sch 'A' Part - XIV (Miscellaneous Items for B/R & E/M Works)
Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
-
-
-
INTERNAL WATER SUPPLY
S& F Angle valve, cast copper alloy chromium plated ISI marked, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule of 15 mm bore & fixed, complete all as specified and directed.
210
-
-
S& F Two way angle valve, cast copper alloy chromium plated ISI marked, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule of 15 mm bore & fixed, complete all as specified and directed.
42
-
-
S&F health faucent (1.5 m long tube) with hook (hand spray) with CP body of 15 mm bore & fixed, complete all as specified and directed.
42
-
-
S&F chromium plated wall mixer 3 in 1 complete all as specified and directed.
42
-
-
S&F chromium plated central hole basin mixer complete all as specified and directed.
42
-
-
S&F chromium plated sink mixer , complete all as specified and directed.
36
-
-
INTERNAL ELECTRIFICATION
M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (One circuit controlled by max 8 points only)
Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
852
-
-
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (One circuit controlled by max 8 points only)
Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
11
-
-
M&L for Point wiring complete for one 5 Amp Socket point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (One circuit controlled by max 4 points only)
Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost..
298
-
-
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), on an independent board, ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and MS conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. (One circuit controlled by max 1 point only)
Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
150
-
-
Supply and fixing modular metal flush box for 8 Module complete all as specified and directed.
95
-
-
S&F 3 module modular AC box 20 Amp, SP MCB with plastic enclosure & Plug top complete all as specified and directed
84
-
-
Supply and fixing MCCB 4 pole, 415 Vols, AC fixed type 100 Amps with braking capacity 25 KA complete all as specified and dierected.
11
-
-
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suit-able size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCCB and with en-closure blank plates for unused way suitable for 4 way complete all as specified and directed
11
-
-
S&F new generation LED security light fitting 20 Watt capacity energy saving and environmental friendly long life LED street light made up of aluminum pressure die cast housing, high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 including 40 mm dia light grade GI pipe bend to shape (1.2 mtr long approx.) fixed on the the wall/pole with necessary MS clamp 25 mm wide and 6 mm in thick-ness with one cote of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
8
-
-
S&F LED lamp 12 Watt suitable for batten holder complete all as specified and directed.
78
-
-
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a luminous efficiency of 120 lum/watt(min) with PF not less than 0.9 with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI80, temp range 0 to 450C, driver efficency85%, power factor0.9, THD 20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level 60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
42
-
-
S&F circular slim surface LED Decorative Wall mounting of 12 Watts with LED Bulb 12 watts complete Polycarbonate housing, globe type Glass protection with high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption 12W, luminaire lumen1000lm, driver and accessories to be prewired, CRI70, LED efficiency 120 lm/W photo biological safety report as per IEC624718 & electrical insulation class I, LED life with L70 criteries -37000 hrs colour temp 6000K, Ingress protection IP-20, ambient temperature 0 to 450C, driver efficiency 85%, THD10% as per IEC 61000-3-2, power factor 0.95, surge protection 2.5 KV, two stages isolatated constant current operated driver with range 150-270V AC and safety extra low voltage safe level 60V DC as per IEC standard with LM79 & LM80 certification complete all as specified and directed.
72
-
-
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % with remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed.
Note:- (a) Additional down rod if required will be measured and paid separately under respective items. (b) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
114
-
-
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
78
-
-
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
(ii) Earthing wire beyond 7.5m shall be measured and paid separately.
22
-
-
SEWAGE DISPOSAL
M&L for RCC Septic tank for 200 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
1
-
-
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M dia X 3.0 M effective depth complete all as speci-fied and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
2
-
-
EXTERNAL WATER SUPPLY
Supply, laying, testing and commissioning centrifugally cast (spun) ductile Iron pipe, 100 mm bore for water with socket & spigot end confirming to IS 8329/2000 in any length for class K-7 suitable for rubber gasket push on with cement mortar lining inside the pipe with outside zinc costing as per IS-8329/2000 in any length laid in trenches complete all as specified and di-rected.
400
-
-
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
2
-
-
Construction of fly ash brick masonry valve pit chamber of size 600 mm X 600 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
6
-
-
EXTERNAL ELECTRIFICATION
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed.
Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
8
-
-
S & F Energy saving and environmental friendly long life 45 W, LED street light made up of pressure die cast aluminium housing with high power LED as lighting source inbuilt driver and surge protection 4KV and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with all fixing arrangement, nuts, bolts and washers on and including bracket mounted on Swan neck poles and LT Poles etc making electrical connection with copper wire from fitting to box and testing complete all as specified and directed.
10
-
-
Supply, fixing, testing and commissioning of automatic street light switch of capacity 8 KW in three phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete accessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp]
(ii) MCB 63Amps (SP),10 KA, 240 volts
(iii) NATURE SWITCH-01
1
-
-
S&F of bus bar chamber with MCB SP 6 Amps -01 No outdoor type of size 400mmx380mmx190mm made out of MS sheet 3 mm thick with aluminium bus bar three phase and neutral each of suitable size fixed on isolators and fixing on sheet pole with proper clamps , nuts, bolts and washers of required size and making connection of LT cables with thimbles, glands and making good the disturbed surface including water proof PVC sticker like danger mark complete all as specified and directed.
10
-
-
Supply, erecting and installation of steel tubular, swaged pole 9 meters long complete with cast iron base plate, finial taper plug, bolts and nuts and screws as specified of type 410 SP-31 conforming to IS-2713-1980 complete all as specified and shown on drawings including the followings:-
(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.
(b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work.
(c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work.
(d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.
(e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.
(f) Painting of coping shall be cement base paint complete all as directed.
(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed.
Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
10
-
-
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made ( as per IS 8623) totally enclosed, dust and vermin proof, double, front side openable, powder coated, IP54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :- BUSBAR :- 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking ca-pacity 35/36 KA with thermal megnatic release type with rotary handle - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.
(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set
(iv) CT (200/5A) -03 Nos OUTGOING:- (i) MCCB 4 pole of capacity 200 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 03 Nos (ii) MCCB 4 pole of capacity 63 Amp breaking capacity 16 KA with thermal magnetic re-lease, adjustable type with rotary handle - 03 Nos
1
-
-
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made ( as per IS 8623) totally enclosed, dust and vermin proof, double, front side openable, powder coated, IP54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :- BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar).
INCOMING:- (i) 4 pole MCCB of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking ca-pacity 35/36 KA with thermal megnatic release type with rotary handle- 01 No. (ii) Digital multifunctional meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No.
(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set
(iv) CT (200/5A) -03 Nos OUTGOING:- (I) MCCB 4 pole of capacity 100 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos (ii) MCCB 4 pole of capacity 63 Amp breaking capacity 16 KA with thermal magnetic re-lease, adjustable type with rotary handle - 01 Nos
3
-
-
Supplying, installation, testing & commissioning of outdoor 11 KV, extensible 630 Amps, 21kA IP54 Outdoor type SF6 gas insulated 630 Amp Copper busbar RMU comprising of manual 3 Load Break Switch . The LBS shall be enclosed in robotically welded minimum 2.5 mm thick non magnetic, non ferrite Stainless Steel tank filled with SF6 with IP class IP67 , leak rate less than 0.1% and HT tank tested for internal arc fault of 21kA upto 01-second as per latest IEC 62271-200. The unit shall have front/side/rear cable entry for ease of installation. Fault Passage Indicator in all LBS. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear Cable bushings shall be site replaceable type for repair of RMU at site. (Inspection of RMU to be done at above manufacturer's factory) 1.Load break switch module - 3 Nos.
2-Manual operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity.
3- “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. 4-Earth fault passage indicator in all LBS.
5-Mechanical ON/OFF/EARTH Indication.
6-Cable boxes suitable for 1x3Cx95 sq mm XLPE Cable with right angle Cable Termination Protectors, situated towards side of RMU.
7-Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON.
8- Cable box should be arc proof with bolted door and interlocked with respective earthing switches. (i) The contractor will produce drawing of load break switch (LBS) for according approval before the ordering of material.
1
-
-
Supply, installing, testing and commissioning of out door type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 315 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +7.5% to -7.5%in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. Perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014, Energy Efficient Level -II as per latest amendment IS-1180(Pt-I) and shall comprise of the following :-
1
-
-
One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception 95 sqmm x 3 core, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete all as specified and directed.
-
-
-
One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable size/rating of cable complete.
-
-
-
Oil conservator with filter type drain valve and oil level guage
-
-
-
De-hydrating breather with first fill of dehydrating agent (silica gel).
-
-
-
Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers
-
-
-
One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
-
-
-
Two earthing terminals on tank cover to facilitate fixing of earth strip for earthing of body
-
-
-
Rating plate and terminal marking plate.
-
-
-
Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral.
-
-
-
First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 50 KV die-lectric strength at 2.5 mm air gap between testing electrodes.
-
-
-
Provn the angle iron channel for floor mounted outdoor type transfomer as per site requirement.
-
-
-
Providing adequate size and nos of channels, embeded in platform floor, for movement of transformer.
-
-
-
Unidirectional roller wheel.
-
-
-
Other accessories as per manufacturer design.
-
-
-
Construction of PCC foundation of suitable size for transformer as per TD No 699
-
-
-
The contractor shall arrange factory visit as detailed by Accepting Officer (AO) to check the above transformer.
-
-
-
RAIN WATRER HARVESTING: M&L for drilling of hole in any strata by mechnical percussion or rotary ring method below ground level including electric loging through any type of strata soil/rock disposal of soil within 10mtr keeping sapce for pea gravel packing and including lowering and extraction of perforated PVC pipe of dia 200mm complete all as specified and directed.
12
-
-
S&F perforated PVC pipe 200mm dia in ay length and fixed in any position including inverted pots with hole on top complete all as specified and directed.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements