Military Engineer Services Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Eprocure
Opening Date16 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 48,50,000
Costs
EMD
₹ 97,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684199_1Tender No
8239/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
17
-
-
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 complete all as specified and directed.
737
-
-
S & F of 2nd class hard wood (SAL) scantling, clean sawn in any position and any description as in framed work complete all as specified and directed.
0.08
-
-
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 with and including demolition of old brick work built in cement mortar or cement lime mortar complete all as specified and directed.
12.6
-
-
M & L for rendering 15 mm thick cement plaster on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
238
-
-
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
278
-
-
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
69.6
-
-
M & L for rendering 12 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
25
-
-
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
481
-
-
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of 2 mm thick wall care putty complete all as specified and directed.
65
-
-
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
32
-
-
M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth and treated with two coats of creosote complete all as specified and directed.
10
-
-
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
81
-
-
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying one coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
59
-
-
M & L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
18
-
-
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough and dismantling of existing old wall tiles complete all as specified and directed.
16
-
-
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough and dismantling of existing old floor tiles complete all as specified and directed.
42
-
-
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in roof kerbs, copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
0.8
-
-
S & F of 4 mm thick E-Board tiles for insulation and acoustic purpose of size 600 X 600 mm fixed with and including anodised GI prepainted snap grid with 25 X 25 X 1.5 mm thick Tee section and 38 X 25 X 2 mm thick angle with hanging / supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4 mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 metre centre both ways with dash fastners complete including making good disturbed surfaces and taking down old ceiling complete all as specified and directed.
94
-
-
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
753
-
-
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
36.8
-
-
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
7
-
-
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
7.5
-
-
Removing surplus excavated material (SOIL) to distance exc. 250 m but not exc. 500 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
97.8
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
19
-
-
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
1400
-
-
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
420
-
-
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
38.8
-
-
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
65.3
-
-
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
14.6
-
-
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
44
-
-
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
8.3
-
-
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
4.8
-
-
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
0.9
-
-
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
5.8
-
-
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
6.19
-
-
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
18.1
-
-
M & L for providing 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
110
-
-
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed.
32.5
-
-
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
127
-
-
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
62.5
-
-
S & F of push pull or manual type steel rolling shutter made of 1.25 mm thick mild steel sheet, with and including ball bearings, top cover, anchoring rod, haps and staple, erected in position as directed complete all as specified and directed.
7.2
-
-
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:4 finished even and fair complete all as specified and directed.
77
-
-
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
48
-
-
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
77
-
-
M & L for 80 mm thick, M-40 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning complete all as specified and directed.
45
-
-
M & L for providing APP based polymeric membrane minimum weighing 3 Kg per sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 Grams per sqm) laid by forced application over and including bituminous primer @ 0.30 Litre per sqm and hot blown bitumen @ 1.20 Kg per square metre after cleaning of roof surface complete all as specified and directed.
37
-
-
M & L for providing plain cement concrete, type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
2.8
-
-
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
350
-
-
M & L for rubber moulded coloured 60 mm thick, M-35 grade machine pressed pre-cast concrete factory made interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning, filling of joints with sand complete all as specified and directed.
350
-
-
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in soft / loose soil and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
43
-
-
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
7.5
-
-
S & F of chain link fencing, made of mild steel wire any size and any mash size, fixed to any type of standard, rails, straining bolts etc. complete all as specified and directed.
244
-
-
S & F of mild steel bolts, purpose made, with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, any size and dia of neck complete all as specified and directed.
10
-
-
S & F of mild steel work in hand rail, half round or other stock section or core for fixing of wooden hand rails, bluster, running bars, nosing of steps, wind ties, post and struts for fencing, flat iron fillets and the like including necessary cutting, drilling holes, notching etc. as required conforming to Fe-290 Grade E-165 complete all as specified and directed.
305
-
-
S & F of rolled mild steel joist, channel, angle, flat iron or Tee sections, fixed independently without connecting plates etc. (cut to ordinary length i.e. within 20 mm of length) confirming to Fe-290 Grade E-165 complete all as specified and directed.
1190
-
-
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor and finishing top surface even and smooth with using extra cement complete all as specified and directed.
45
-
-
S & F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
54
-
-
M & L for vitrified ceramic coloured (Light Shade) tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
95
-
-
M & L for vitrified ceramic coloured (Light Shade) tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm, as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough complete all as specified and directed.
18.9
-
-
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
339
-
-
M & L for 18-20 mm thick machine cut Z-black granite stone slab as in vertical surfaces such as skirting / dado, laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including necessary cutting, grinding, rubbing, polishing rounding to exposed edges complete all as specified and directed.
8.2
-
-
S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. confirming to Fe-410-W (Grade E-250) Quality 'B', drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening complete all as specified and directed.
70
-
-
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators or partitions with one or more rebates including joining cleat etc. for fixing complete all as specified and directed.
9
-
-
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminum snap beading, screws etc. complete all as specified and directed.
2
-
-
S&F powder coated aluminium sliding windows frame with movable shutter (sliding on minimum two PVC roller of best quality) for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and including 5.50 mm thick tinted glass & clips, frame made with aluminium beading, clips, frame made with aluminium section as appended below and following items deemed to be include:-
(i) Window frame : 68.4mm x 38mm x 1.15mm thick for three tracks
(ii) Top /bottom rail and style of shutter : 15mm x 37.5mm x 1.15mm thick and over
(iii) Aluminium beading-0.7mm thick
(iv) Aluminium Grill with bulb heaight 4.5mm square shape fixed on frame including necessary fixing arrangement like U-clip, flat aluminium section matching with window & dia grill as directed by engineer-in-charge.
(v) SS wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed in aluminium window or along with F/Y section fixed with aluminium wire staples complete.
(vi) Aluminium fittings such aluminium suitable handle with auto interlock cap with suitable size.
(vii) Making good wall surfaces with silicon to match with existing surface complete all as specified and directed.
1.5
-
-
S & F of 5.50 mm thick tinted sheet glass, pin head type as in glazing fixed with aluminium joinery. in square not exc. 0.5 sqm in each pane complete all as specified and directed.
3
-
-
M & L for providing 100 mm thick cement concrete 1:2:4 type B-2, using 40 mm graded stone aggregate as in road / path, hard standing etc. with and including all necessary form work to divide the area in panels not exc. 9 Sqm each and providing 10 mm thick joints through out the thickness of road / path duly filled with mastic filling of one part of 85 / 25 hot bitumen and three part of coarse sand (By weight) with and including making impression of expanded metal whilst concrete is green complete all as specified and directed.
43.2
-
-
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
43.2
-
-
M & L for glazed ceramic coloured tiles 450 mm X 300 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
295
-
-
M & L for providing 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
310
-
-
M & L for rubber moulded coloured 80 mm thick, M-40 grade machine pressed pre-cast concrete factory made interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning, filling of joints with sand complete all as specified and directed.
310
-
-
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
84
-
-
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe-410-S including cutting, welding etc. complete all as specified and directed.
750
-
-
M & L for 80 mm thick, M-40 grade machine pressed pre-cast concrete factory made interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning, filling of joints with sand and providing 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
150
-
-
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick single side prelam PVC sheet and edges will be painted to match with prelam sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
4.8
-
-
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and single side prelam PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of single side prelam PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable side feathered edge beading and joined together with solvent cement as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
1.6
-
-
S & F of 100 mm long stainless steel butt hinges, medium weight cold rolled complete all as specified and directed.
3
-
-
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
2
-
-
S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
2
-
-
S & F of factory made steel window or ventilator fixed type with glazing bars complete all as specified and directed.
0.45
-
-
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
0.4
-
-
M & L for 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND WILL BE MEASURED AND PAID SEPARATELY.
1.8
-
-
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
32
-
-
Supply only liquid water proofing compound complete all as specified.
1
-
-
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster / screed bed on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough complete all as specified and directed.
7.4
-
-
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
10
-
-
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
4
-
-
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
15
-
-
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
15
-
-
S & F of 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
3
-
-
S & F of 15 mm bore fancy type, chromium plated stop valve / angle valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
6
-
-
S & F Vitreous China table top wash basin flat back, including waste coupling, brass waste pipe, chain and plug and porcelain stopper brackets complete all as specified and directed.
1
-
-
S & F vitreous china wash down water closet single piece -WC (cascade pattern) with UF seat cover, hinge, fixing accessories, cistren fittings, size 655 x 665 x 760mm S-trap-300 white, while including connection to drain pipe complete all as specified and directed.
Make Jaquar Cat No LYS-WHT-38851S, CERA-1013178, Paryware- CR47K
1
-
-
S & F Vitreous china bowl sensor enabled urinal flat back with grating and union for discharging pipe complete all as specified and directed.
1
-
-
S & F health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25metre long flexible tube and ABS wall hook including making connections and tied in position complete all as specified and directed.
1
-
-
S & F fancy type 15mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB complete all as specified and directed.
1
-
-
S & F fancy type glass corner 300mm radius 10mm thick toughened glass with railing fixed with fancy type screwed complete all as specified and directed.
2
-
-
S & F of 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
7
-
-
S & F of 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
2
-
-
S & F of 1200 mm X 600 mm X 5.5 mm thick beveled edge looking mirror of selected quality glass mounted on 8 mm thick commercial plywood with and fixed to wall with PVC rawl plugs with chromium plated brass screw complete all as specified and directed.
1
-
-
M & L for 75 mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
3
-
-
S & F of 500 Litre capacity three layered white colour rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
1
-
-
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
3
-
-
S & F of 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
3
-
-
M & L for 150 mm bore salt glazed stoneware drain pipes grade ‘A’ laid in trenches and jointed in cement sand mortar 1:1 with spun yarn complete all as specified and directed.
20
-
-
M & L for cement concrete 1:4:8, typeDC-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
19.5
-
-
M & L for cutting into existing manhole for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia pipe complete all as specified and directed.
1
-
-
Supply, installation, testing and commissioning of Solar Hot Water System (Flat Plate Collector) pressurized type based on indirect transfer of heat of capacity 250 Litres per day with and including backup stainless steel hot water tank duly insultated complete all as specified and directed.
2
-
-
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required suitable for hot water supply duly insulated with glass wool and 28 SWG thick aluminium cladding complete all as specified and directed.
130
-
-
S & F of 250 Litre capacity three layered white colour rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
2
-
-
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches complete all as specified and directed.
120
-
-
S & F of 15 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
6
-
-
S & F of Distribution board (DB) IP 20 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar earth bar ,single pole and neutral 250 volts ,flush to wall complete for fixing of MCBs, Isolators etc as per Cat Part No. 607701 of Legrand or equivalent complete all as specified and directed MCB DB
4
-
-
S & F MCB ISI Marked 240 Volt, 50 Hz, SPN 63 Amps breaking capacity 10 KA complete all as specified and directed.
4
-
-
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
130
-
-
M & L PCC type B-1 (1:2:4) (using 20mm grade stone aggregate concrete block masonry with solid blocks exc 10cm in width and setting in mortar complete all as specified and directed.
2
-
-
S & F 1100 volts grade PVC Flat twin core aluminium cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connections of size 16 sqmm, 2 core complete all as specified and directed.
Note Cost of Saddles and connected items for connection of cables on the wall / floor in included in the quoted rates.
120
-
-
Material and labour for point wiring with single core PVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes and covered with 3 mm thick plastic laminated sheet cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:-
(a) One light / fan/ exhaust fan point controlled by one switch.
7
-
-
All as per Srl Item No 120 above but for One 5 pin 5 Amp switch socket out let point on an independent board.
1
-
-
All as per Srl Item No 120 above but for One 5 pin 5 Amp socket out let point controlled by one switch on same board.
1
-
-
All as per item 120 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified and directed.
1
-
-
S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
1
-
-
S&F Socket outlet 2 in 1, 6 pin, 15/5A flush type complete all as specified and directed.
1
-
-
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
9
-
-
S&F Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed.
2
-
-
Supply and Fixing ceiling fan regulator, electronic stepped type, AC 230 volts complete all as specified and directed.
2
-
-
Supply and Fixing ceiling rose 2/3 terminals 230 volt AC complete all as specified and directed.
7
-
-
S&F LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round fleaxible three core copper conductor cable of suitable size and testing on completion, complete all as specified and directed.
5
-
-
S & F Ceiling fans complete with blades, down rods, and accessories, 230V, 1200mm sweep, five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
2
-
-
S & F MCB single pole 6 to 32 Amp 240 volt, 'B; curve 10 KA complete all as specified and directed.
6
-
-
S & F flush sheet metal enclosure SPN DB 8 way with double door IP-42 detachable gland plates, fluh mounting for MCB fitted with bus bar, earth bar and neutral links complete all as specified and directed.
1
-
-
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified including testing after completion complete all as specified and directed.
1
-
-
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 4 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
19
-
-
Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%