Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Mar 2024
Closing Date9 Apr 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F as in replacement AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit complete all as specified and directed.

2

-

-

... More
M&L for repair of AC single phase 230 volt PCB for 1.5/ 2.0 TR capacity split/window AC cooling unit complete all as specified and directed.

20

-

-

... More
S&F as in replacement AC single phase 230 volts remote (Hand set) for 1.5/ 2.0 TR capacity window/split AC complete all as specified and directed.

10

-

-

... More
M&L for replacement of blower motor for 1.5/2 TR window complete all as specified and directed.

5

-

-

... More
M&L for replacement of runner motor for 1.5/2 TR split AC complete all as specified and directed.

5

-

-

... More
M&L for replacement of strainer for window/split AC of any capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of 4/6 mfd capacitor for blower motor of window/split AC of any capacity complete all as specified and directed.

20

-

-

... More
M&L for replacment of 36/50 mfd running capacitor for compressor of window/split AC of any capacity complete all as specified and directed.

30

-

-

... More
M&L for replacement of 80/100 starting capacitor for compresor of window/split AC of any capacity complete all as specified and directed.

10

-

-

... More
M&L for replacement of thermostat for 1.5/2 TR window/split AC complete all as specified and directed.

10

-

-

... More
M&L for replacement of sensor for 1.5/ 2.0 TR window/split AC complete all as specified and directed.

10

-

-

... More
M&L for replacement of fan blade of blower motor for 1/1.5/2 TR window/split AC complete all as specified and directed.

10

-

-

... More
M&L for replacement of over load protector for 1.5/2 TR window/split AC complete all as specified and directed.

5

-

-

... More
M&L for replacement of capillary copper tube of size 0.064 inch dia complete all as specified and directed.

5

-

-

... More
M&L for replacement of runner for 1.5/ 2.0 TR window/split AC complete all as specified and directed.

5

-

-

... More
M&L for replacement of starting relay for 1.5/2 TR window/split AC complete all as specified and directed.

5

-

-

... More
M&L for replacement of air filter for 1.5/2 TR window/split AC complete all as specified and directed.

20

-

-

... More
Disconnecting electrically and mechanically and taking out existing unserviceable sealed compressor unit from 1.5/2 TR window AC of any make and S & F in replacement new sealed compressor suitable for 1.5/2 TR window AC and connecting up suction and discharge pipe line with gas welding and gas charging complete all as specified and directed.

5

-

-

... More
All as per item No 1.20 above but for 1.5/2 TR split AC complete all as specified and directed. Note for Item No 1.20 & 1.21 : Compressor/sealed unit shall have one year replacement guarantee from date of installation.

5

-

-

... More
S&F in replacement of swing motor as per existing size and type for 1.5/2 TR window AC complete all as specified and directed.

3

-

-

... More
S&F in replacement of swing motor as per existing size and type for 1.5/2 TR split AC complete all as specified and directed.

3

-

-

... More
S&F 20mm dia PVC pipe, heavy duty for drain out of condensing water of window/split AC including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe with sadles etc to match the existing surface with original specifications complete all as specified and directed.

40

-

-

... More
Supply and laying copper pipe (hard) 5/8" dia with PUF insulation, CFC free etc as required at site complete all as specified and directed.

30

-

-

... More
Supply and laying copper pipe (hard) 3/8" dia with PUF insulation, CFC free etc as required at site complete all as specified and directed.

25

-

-

... More
Cleaning/servicing of cooling/condensing coil with the help of compressed nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour for charging of refrigerant R-22/R-32/R-410 as required including replacement of strainer and finding out the leakage, brushing the same and testing of 1/1.5/2 TR window/split AC complete all as specified and directed.

15

-

-

... More
M&L for taking out and dismantling the existing rusted unserviceable condensor coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new condensing coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified and directed.

2

-

-

... More
M&L for taking out and dismantling the existing rusted unserviceable cooling coil from existing system of 1/1.5/ 2.0 TR window/split AC located at different places after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replace with new cooling coil as per existing size and specification including necessary fixing arrangement and electrical connection and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified and directed.

2

-

-

... More
M&L for gas charging of refrigerant R-22/R-32/R-410 in window/split AC complete all as specified and directed.

20

-

-

... More
Supply and install Split Ac Stand / Heavy Duty Air Conditioner Outdoor Unit mounting bracket made up of Heavy Duty GI Steel (For Maximum Strength ) Load Carring Capacity Upto 160 Kgs (Best in Class) complete all as specified and directed.

5

-

-

... More
S&F metal clad AC plug top 32A, 230 volt complete all as specified and directed.

10

-

-

... More
Part-II [Refrigerator/Deep freezer]

-

-

-

... More
Material and labour for dismantling the cover of condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

50

-

-

... More
M&L for replacement of starting relay of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of capillary copper tube of size 0.36 mm of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

10

-

-

... More
Disconnecting defective cooling coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new cooling coil and fixing in original position as per existing complete all as specified and directed.

5

-

-

... More
Disconnecting defective condensing coil of refrigerator/deep freezer upto 315 ltrs capacity and replacing the same with new condensing coil and fixing in original position as per existing complete all as specified and directed.

5

-

-

... More
M&L for replacement of fan motor of refrigerator/deep freezer of any capacity complete all as specified and directed.

10

-

-

... More
M&L for replacment of 6/10 mfd running capacitor for compressor of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

15

-

-

... More
M&L for replacement of 40/60 starting capacitor for compresor of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

10

-

-

... More
M&L for replacement of 80/100 starting capacitor for compresor of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

10

-

-

... More
M&L for replacement of thermostat of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of Inner lights of refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

5

-

-

... More
S&F in replacement of over load protector for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of AC single phase 230 volt PCB for refrigerator/deep freezer upto 315 ltrs capacity complete all as specified and directed.

26

-

-

... More
Disconnecting electrically and mechanically refrigerator/deep freezer and taking down old unsv sealed compressor unit of refrigerator/deep freezer upto 315 ltrs capacity and replacement with new sealed unit of compressor of same size, type and capacity including connecting sealed unit and discharge pipe with gas weldind/soldering including gas charging complete all as specified and directed. Note : Compressor/Sealed unit shall have one year replacement guarantee from date of installation.

14

-

-

... More
Leak testing of gas circulation system of refrigerator/deep freezer upto 315 ltrs capacity and supply & charging of refrigerant Gas R-12/R-134A as per existing in entire system including supply and replacement of drier/filter and punching/providing dead plug complete all as specified.

18

-

-

... More
Part-III [Water Cooler]

-

-

-

... More
M&L for dismantling the cover of condensor and cooling coil, thoroughly cleaning/servicing the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for water cooler upto 150 ltrs capacity complete all as specified and directed.

60

-

-

... More
Taking down unserviceabe sealed compressor unit of water cooler upto 150 ltrs capacity and S&F in replacement new sealed compressor and connecting up suction and discharge copper pipe , gas filter, capillary etc with gas charging, welding and commissioning complete all as specified and directed. Note : Compressor/Sealed unit shall have one year replacement guarantee from date of installation.

15

-

-

... More
Leak testing of gas circulation system of water cooler upto 150 ltrs capacity and supply & charging of refrigerant Gas R-134A as per existing in entire system including supply and replacement of drier/filter and punching/providing dead plug complete all as specified and directed.

20

-

-

... More
M&L for gas charging of refrigerant R-134A/R-22 in refrigerator/deep freezer/Water Cooler complete all as specified and directed.

10

-

-

... More
M&L for replacement of fan motor of water cooler of any capacity complete all as specified and directed.

20

-

-

... More
S&F PVC connection pipe 15mm dia and 90 cm length with PTMT nuts & washers at both ends for water connection of water coolers upto 150 ltrs capacity complete all as specified and directed.

20

-

-

... More
S&F PVC drain pipe of existing size flexible heavy duty with necessary saddles and fittings for drain out water from water cooler complete all as specified and directed.

10

-

-

... More
S&F in replacement of fan blade for water cooler upto 150 ltrs capacity complete all as specified and directed.

15

-

-

... More
S&F in replacement of water tray stainless steel for water cooler upto 150 ltrs capacity complete all as specified and directed.

2

-

-

... More
M&L for replacement of 10/15 mfd running capacitor for Water Cooler upto150 ltrs capacity complete all as specified and directed.

10

-

-

... More
M&L for replacement of 40/60 mfd starting capacitor for water cooler upto 150 ltrs capacity complete all as specified and directed.

10

-

-

... More
M&L for replacement of 15mm bore chromium plated push cock as per existing shape suitable for water cooler upto150 ltrs capacity complete all as specified and directed.

15

-

-

... More
M&L for replacement of thermostat for water cooler upto 150 ltrs capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of starting relay suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.

15

-

-

... More
M&L for replacement of over load protector suitable for Water Cooler upto 150 ltrs capacity complete all as specified and directed.

15

-

-

... More
Part-IV DESERT COOLER

-

-

-

... More
Repair/maint/servicing of desert coolers upto 4000 Cum/hr by dismantling desert cooler complete disconnecting and removal of cooler fan and water pump, old wornout wood wool pads/khus pads etc and painting the complete cabinet of desert cooler externally one coat over existing coat including body side panel, front panel and internally with one coat of black synthetic enamel paint after complete rubbing, cleaning, overhauling and painting of exhaust fan, kit fan general checking, greasing/oiling of pumps and fixing back to its existing position to make functional to the entire satisfaction complete all as specified.

40

-

-

... More
S&F wood wool pads suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

40

-

-

... More
S&F PVC pipe heavy duty 15mm bore from water pump to wool compartment of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

20

-

-

... More
S&F PVC water distributor 4 way suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

10

-

-

... More
S&F rotary/bed switch 5 Amp suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

20

-

-

... More
M&L for rewinding of fan motor of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

20

-

-

... More
M&L for replacement of fan motor of desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

5

-

-

... More
S&F in replacement of water lifting pump vertical type single phase, 230V, 18 watt suitable for desert cooler upto 4000 Cum/hr capacity complete all as specified and directed.

30

-

-

... More
S&F fan blade for desert cooler fan upto 4000 Cum/hr capacity complete all as specified and directed.

15

-

-

... More
Part-V CEILING FAN

-

-

-

... More
Taking down defective ceiling fan 1200/1400 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacement of unsv components complete all as specified and directed. (Note : Items required for repairing will be measured and paid separately as supply only under following items)

3800

-

-

... More
Supply only bearing 6201/6202 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed.

2600

-

-

... More
Supply only MS fan hanger clamp with suitable bolts, nuts, washers, split pin and rubber reel complete all as specified and directed.

500

-

-

... More
Supply only condenser 2.5 Mfd suitable for ceiling fan 1200/1400 mm sweep with clip complete all as specified and directed.

4500

-

-

... More
Supply only ceiling fan downrod 450 mm long (minium thickness 1.50 mm) complete all as specified and directed.

20

-

-

... More
Supply only ceiling fan downrod 1200 mm long (minium thickness 1.50 mm) complete all as specified and directed.

20

-

-

... More
Supply only ceiling fan downrod 5000 mm long (minium thickness 1.50 mm) complete all as specified and directed.

20

-

-

... More
Rewinding of burnt ceiling fan of 1200/1400 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed.

2680

-

-

... More
M&L for painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.

2680

-

-

... More
S&F MS Fan hook with clamps, bolt nut etc suitable for fixing of fan with GI pipe or wood frame made by 40/50 mm dia or angle iron of size up to 50mm complete all as specified and directed.

50

-

-

... More
Part-VI EXHAUST FAN

-

-

-

... More
Taking down defective exhaust fan upto 600 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacement of unsv components complete all as specified and directed. (Note : Items required for repairing will be measured and paid separately as supply onlyunder following items)

400

-

-

... More
Supply only Exhaust fan blade suitable for 300 mm sweep complete all as specified and directed.

10

-

-

... More
Supply only Exhaust fan blade suitable for 450/600 mm sweep complete all as specified and directed.

10

-

-

... More
Supply only condenser 4/6 mfd for exhaust fan upto 600mm sweep with clip complete all as specified and directed.

420

-

-

... More
M&L for louver shutter suitable for exhaust fan of 300 mm sweep complete all as specified and directed.

11

-

-

... More
M&L for louver shutter suitable for exhaust fan of 350/380 mm sweep complete all as specified and directed.

10

-

-

... More
Supply only bush suitable for exhaust fan of 300 mm sweep complete all as specified and directed.

160

-

-

... More
Supply only bearing(6200/6201) suitable for exhaust fan of 350/380 mm sweep complete all as specified and directed.

100

-

-

... More
Supply only bearing (6202) suitable for exhaust fan of 450 mm sweep complete all as specified and directed.

80

-

-

... More
Rewinding of burnt exhaust fan of 300 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed.

160

-

-

... More
Rewinding of burnt exhaust fan of 350/380 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed.

120

-

-

... More
Rewinding of burnt exhaust fan of 450 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed.

100

-

-

... More
Part- VII Wall mounted fan

-

-

-

... More
Taking down of defective wall mounted fan upto 400 mm sweep, checking of faults and refixing the same in original position after gressing and repairing of faults including replacing old components complete all as specified and directed. (Note : Items required for repairing will be measured and paid separately as supply only under following items)

20

-

-

... More
Supply only bearing suitable for wall mounting fan upto 400 mm sweep complete all as specified and directed.

19

-

-

... More
Supply only bush suitable for wall mounting fan upto 400 mm sweep complete all as specified and directed.

10

-

-

... More
Supply only selector switch suitable for wall mounting fan upto 400 mm sweep complete all as specified and directed.

14

-

-

... More
Rewinding of burnt wall mounting fan upto 400 mm sweep with super enamelled copper winding wire as per existing weight complete all as specified and directed.

17

-

-

... More
M&L for replacement of swing motor of wall mounting fan upto 400 mm sweep capacity complete all as specified and directed.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.