If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Oct 2024
Closing Date30 Nov 2024
Tender Amount₹ 22,60,000
Costs
EMD
₹ 45,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681672_1Bid Award Id
ViewTender No
GE(I)/KAN/T-74 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fix window type room air conditioner electric driven of capacity 1.5 TR single phase 230 Volt + 10%, 50 Hz, AC supply with cordless remote control unit with copper condenser air cooled with BEE 5 star rating including required cutting of holes in walls / window / aluminium partition etc of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing complete all as specified and directed. Note :- (i) Cutting holes in walls / window / aluminium partition etc of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Provision of angle iron stand / wall mounted platform etc for fixing / supporting the AC unit is inclusive in above rate. (iii) Contractor shall submit guarantee / warranty certificate from manufacturer and shall be responsible for any defect till guarantee/warantee period.
14
-
-
... More
Disconnecting, dismantling and taking out carefully of Water cooler/refrigerator any type/ any capactiy with accessories and deposited to MES store yard complete with remote complete all as specified and directed.
4
-
-
... More
Supply and fix single door electric driven (single phase) refrigrator of capacity 165 Ltr complete all as specified and directed.
1
-
-
... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage of 180 litres and nominal cooling capacity 150 litres per hour, complete all as specified and directed.
2
-
-
... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 120 litres and nominal cooling capacity 60 litres per hour, complete all as specified and directed.
1
-
-
... More
S&F sub main wiring for circuit of size 4 sqmm 2 core alongwith earth wire of 2.5 sqmm single core of FRLS PVC insulated unsheathed cable (FR), 1100 volts grade with multistranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including PVC non metalic rigid conduit/casing of suitable size and conduit/casing accessories run on surface of wall/ceiling etc and connecting terminal ends of suitable size complete all as specified and directed.
565
-
-
... More
M&L for single pole and neutral sheet metal encloser with a two pin with earth plug and socket 20 amps 240 volts with one single pole MCB of 20 Amps complete all as specified and directed.
21
-
-
... More
Disconnecting electrically, existing ceiling/exhasut fan any type and capacity and taking down with due care, dismantling blades and deposting to MES store yard with all accessories complete all as specified and directed. Note: T&P will be provided by the contractor for reaching any height of the bldg/ Hanger.
145
-
-
... More
Supply and fixing ceiling fans (existing or new location directed by EIC) with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor wih remote (BLDC) complete all as specified and directed.
Note : 1. Additional down rod if required will be measured and paid separately. 2. T&P will be provided by the contractor for reaching any height of the bldg/ warehouse/ Hanger.
70
-
-
... More
All as per item No 12 above but for ceiling fan 1400mm sweep & min air delivery 245 CFM complete all as specified and directed.
46
-
-
... More
Supply and fixing of Exhaust Fan heavy duty 230 V, AC single phase of size 450 mm sweep 1400 RPM with louver shutter with fixing arrangement including grouting of nuts, bolts electric connection and writing MES No. with black synthetic enamel paint/engraving tool etc in wall complete all as specified and directed.
23
-
-
... More
S&F in replacement of rigid steel conduit welded cut to pieces of size 20mm dia treated both ends for hanging ceiling fan 1200/1400mm size including necessary hook, calmps both sides with hook, nuts bolts, rubber real etc complete all as specified and directed.
50
-
-
... More
Supply and laying 40mm dia galvanized, “Medium class” pipe, on the wall roof for hanging of ceiling fans and making good wall surface complete all as specified and directed.
65
-
-
... More
Disconnecting, dismantling desert cooler of any type/capacity with accessories and taking out carefully and deposited to MES store yard complete all as specified and directed.
10
-
-
... More
Supply, installation, testing and commissioning of desert cooler of fiber body fully exhaust fan 450 mm sweep, 1400 rpm motor of copper winding and suitable capacity submersible pump cabinet size not less than 69cmx117cmx47cm water tank of capacity 72 Liters ,1000 watts speed control electronic regulator, suitable size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixing accessories complete all as specified and directed Note:- All electrical equipments shall be of ISI Marks.
10
-
-
... More
M&L for fixing of fan hook on the girder/ GI tube at existing or new location inside the hanger or buiding ,above or below of false ceiling at any hight of CQA (M) controllerate complete all as specified and directed.
122
-
-
... More
M&L for concealed point wiring of PVC insulated and unsheather cable 1.5 sqmm (nominal area) multistranded copper conductor 1100 v FRLSH grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling with all accessories including 1.5 sqmm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth for One light/fan point controlled by one switch complete all as specified and directed. Note : 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor shall deemed to included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .
65
-
-
... More
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC pipe fixed on wall etc complete all as specified and directed.
75
-
-
... More
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 0.5 Sqmm twin core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC pipe fixed on wall etc complete all as specified and directed.
250
-
-
... More
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin of size 45-75 Cm long as per site requirement complete all as specified and directed.
50
-
-
... More
All as per item No 24 above but of size 1 Mtrs long complete all as specified and directed.
20
-
-
... More
All as per item No 24 above but of size 1.5 Mtrs long complete all as specified and directed.
20
-
-
... More
All as per item No 24 above but of size 2 Mtrs long complete all as specified and directed.
18
-
-
... More
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated with all accessoriessuch as safety valve, thermostate, of NRV, connection piece etc complete all as specified and directed.
3
-
-
... More
M&L for concealed point wiring of PVC insulated and unsheather cable 4 sqmm (nominal area) multistranded copper conductor 1100 v FRLSH grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling with all accessories including 4 sqmm PVC insulated unsheathed multistranded copper conductor for common& 2.5 sqmm for earth connection dully for geyser complete all as specified and directed :- Note) : 1. The cutting chases shall b finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor shall be deemed to included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .