Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Sep 2024
Closing Date30 Oct 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour for dry river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment

272

-

-

... More
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.

25

-

-

... More
All as per srl item No 6 here-in-before but using old bricks obtained under srl item No 1 here in before.

4

-

-

... More
M&L for demolition / cutting of road / path / hardstading / concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge

0.5

-

-

... More
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads / path / hardstanding etc complete all as specified and as directed by Engineer-in-Charge.

0.5

-

-

... More
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed

20

-

-

... More
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking out old pipe complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts , bolts, washers, alumunium thimble, ferrule complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks / tiles / block and pipe shall be measured and paid separately under appropriate items.

250

-

-

... More
All as per Item No 14 but cable of size 16 Sqmm 2 core.

250

-

-

... More
All as per Item No 14 but cable of size 16 Sqmm 4 core.

500

-

-

... More
All as per Item No 14 but cable of size 25 Sqmm 4 core.

500

-

-

... More
All as per Item No 14 but cable of size 35 Sqmm 3.5 core.

250

-

-

... More
All as per Item No 14 but cable of size 50 Sqmm 3.5 core.

500

-

-

... More
All as per Item No 14 but cable of size 70 Sqmm 3.5 core.

250

-

-

... More
All as per Item No 14 but cable of size 95 Sqmm 3.5 core.

500

-

-

... More
All as per Item No 14 but cable of size 120 Sqmm 3.5 core.

500

-

-

... More
All as per Item No 14 but cable of size 185 Sqmm 3.5 core.

500

-

-

... More
All as per Item No 14 but cable of size 240 Sqmm 3.5 core.

200

-

-

... More
All as per item Srl No 14 above but cable of cross sectional area 630 Sqmm , 1 core

100

-

-

... More
M&L for Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.

5

-

-

... More
M&L for Earthing in replacement complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.

18

-

-

... More
M&L for Disconnecting the existing cable from Panel / Pole, removing the old end termination joint, preparing the end for jointing, supply and fix Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm and reconnecting the cable with panel etc.

5

-

-

... More
All as per item No 28 above but end termination joint sutable for cable of size 25 to 50 Sqmm

10

-

-

... More
All as per item No 28 above but end termination joint sutable for cable of size 70 to 120 Sqmm

10

-

-

... More
All as per item No 28 above but end termination joint sutable for cable of size 150 to 185 Sqmm

5

-

-

... More
All as per item No 28 above but end termination joint sutable for cable of size 240 to 300 Sqmm

2

-

-

... More
M&L for Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm

16

-

-

... More
All as per item No 33 above but straight through joint sutable for cable of size 25 to 50 Sqmm

40

-

-

... More
All as per item No 33 above but straight through joint sutable for cable of size 70 to 120 Sqmm

40

-

-

... More
All as per item No 33 above but straight through joint sutable for cable of size 150 to 185 Sqmm

10

-

-

... More
All as per item No 33 above but straight through joint sutable for cable of size 240 to 300 Sqmm

6

-

-

... More
Disconnecting faulty 1.1 KV LT cables of any size and any length from both ends Hiring of cable fault detector machine to detect exact position of fault, removal of Fault, Re-connections and testing of cables after removal of fault including excavation, returung filling, Removal, relaying of cable protection cover etc complete as specified and directed. Note : (a) 1.1 KV LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown alongwith fault locating machine and manpower. In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.

70

-

-

... More
Supply & Fix in replacement twin core, 6 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.

600

-

-

... More
Supply & Fix in replacement twin core, 10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.

600

-

-

... More
Supply, fix connecting and testing in replacement MCCB 63 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

5

-

-

... More
Supply, fix connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

2

-

-

... More
Supply, fix connecting and testing in replacement MCCB 630 Amp 4 pole 50 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.

2

-

-

... More
Supply and fix in replacement double pole sheet metal enclosure made of 1.6 mm thick MS sheet factory made with powder coat painting including 01x MCB 20 Amps 10 kA complete all as directed Note : The cost of suitable size clamp / Nut bolts required at site for fixing of enclosure on garden light post / wall is deemed to be included in the quoted rate by the contractor.

30

-

-

... More
S&F in replacement on load change over switch open execution of capacity 400 Amps, 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel / Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed

1

-

-

... More
S&F in replacement on load change over switch open execution of capacity 250 Amps, 4 pole, 415 volt , 50 Hz fixed in any type of existing LT panel / Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed

1

-

-

... More
Supply and fix in replacement MCCB FP 125 Amps, 25 kA, 415 Volt AC, 50 Hz, thermal magnetic release complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.

20

-

-

... More
Supply, fix connecting and testing in replacement MCB 6-32 Amps, SP 10KA after taking down old existing un serviceable MCB complete all as directed.

10

-

-

... More
Supply, fix, connecting and testing in replacement MCB 6-32 Amps, DP 10KA after taking down old existing un serviceable MCB complete all as directed.

10

-

-

... More
Supply, fix connecting and testing in replacement MCB 63 Amp 4 pole 10KA after taking down old existing un serviceable MCB complete all as directed.

10

-

-

... More
Supply, fix connecting and testing in replacement isolator 100 Amps, FP after taking down old existing un serviceable isolator complete all as directed.

19

-

-

... More
Deployment of manpower / tools / machinery etc for restringing of existing loose over head line having 5 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 5 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.

500

-

-

... More
Deployment of manpower / tools / machinery etc for restringing of existing loose over head line having 4 Nos ACSR conductor and 01 Nos GI wire any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge. Note:- 4 Run of ACSR conductor with 01 Run of GI wire shall be measured as 01 RM for payment.

500

-

-

... More
Deployment of manpower / tools / machinery etc for trimming / pruning of the tree branches coming cross electric power head line LT feeder clearing the span ( 30 to 35 metre long) and making the free from touching the tree branches complete all as specified and as directed by Engineer-in-Charge

1000

-

-

... More
Supplying and fix in replacement LT spacer in LT overhead line of ACSR conductor, shall be made of high quality regid PVC, the spacer shall be water proof weather proof and shock proof the spacer shall also be suitable for use on both horizental and vertically configuration of LT O/H line ACSR conductor 5 wire / 4 wire system complete.

25

-

-

... More
Material and labour disconnecting faulty / burnt end or portion of cable from LT panel / LT pole / main switch / changeover etc by removing the cable from loop including necessary excavation & earth work, cleaning the surface area not less than 1 mtr surrounding the panel / pole, provision of suitable size of thimble, LT tap, relaying and reconnecting the cable by removing faulty / burnt portion of cable and preparing fresh terminals for 16 Sqmm 3.5 / 4 core to 240 Sqmm 3.5 core of LT cable to LT Panel / pole / main switch / changeover complete all as directed.

150

-

-

... More
S&F in replacement Aluminium conductor, steel reinforced (ACSR) of code name ferret / weasel on LT pole of size as ordered including stringing and jointing for overhead line on poles including aluminium binding wire 14 SWG, jumpers, line tapes etc supplied and fixed in repairs including dismantling of old ACSR conductor from LT poles complete all as specified and as directed by Engineer-in-Charge.

0.5

-

-

... More
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.

0.5

-

-

... More
Supplying and fix in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade

5

-

-

... More
S&F in replacement Shackle type, porecelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nusts working pressure in volts 1100 Volts height 75 mm, max dia 90 mm, galvanised steel fittings, section of straps 31 x 3mm, dia of bolts 12 mm complete all as specified and directed.

5

-

-

... More
Supplying, transporting, erecting in replacement Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, the exposed surface of steel tubular poles shall be painted with two coat of aluminum paint over a coat of red oxide, embaded portion of the pole shall be painted with one coat of bituminous paint. 05 Nos black and Yellow alternate strip with two coat of synthetic enamel paint shall be painted up to the the height of 1.5 M from copping of the pole including numbering on pole in black colour synthetic enamel paint complete all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.