If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Oct 2024
Closing Date26 Oct 2024
Tender Amount₹ 9,90,000
Costs
EMD
₹ 19,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_648804_2Bid Award Id
ViewTender No
9161/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed.
Note:- Punned thickness shall be considered for measurement purpose.
90
-
-
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified & directed.
10000
-
-
Labour only for reuse of serviceable bricks obtained from item No 1.00 complete all as specified & directed.
2000
-
-
M&L for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed.
Note: Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site.
30
-
-
S&F in replacement GI tubing light grade 80 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified & directed.
Make: Tata / Jindal / Swastik
15
-
-
S&F in replacement galvanised water tubing light grade 50 mm dia of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified & directed.
Make: Tata / Jindal / Swastik
20
-
-
Dismantling of ACSR conductor complete all as specified & directed.
1
-
-
Dismantling of GI wire/ conductor of any type and size from over head or other situation complete all as specified and directed.
0.3
-
-
Supply, laying, jointing, connecting and testing in replacement XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 70 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items.
Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
600
-
-
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 35 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items.
Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
850
-
-
Supply, laying, jointing, connecting and testing in replacement XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 25 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items.
Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
200
-
-
Supply, laying, jointing, connecting and testing in replacement XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 16 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective items.
Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
200
-
-
Labour for re-laying, connecting, jointing, thembling using in suitable size and cramping etc to serviceable XLPE insulate LT cable in all specification (240/95/70/50/25/16 sqmm) incl brick (re-use) and sand (Provided fresh) etc all as per existing complete with other site required works complete all as specified and directed.
Note : Excavation and Sand cushioning punned dept shall be measured and paid separately under respective items.
200
-
-
M&L for tree trimming cut away dead or excess branches from trees or shrubs to maintain clearance along with over head power lines using climbing equipment and collecting the debris for disposal and removing broken limbs from electric wires by using hooked extension poles complete all as specified and as directed.
Notes:- Span is taken as distance between two adjacent poles.
30
-
-
Supply, install, testing and commissioning of LT panel size 90 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
1
-
-
Notes for Serial Item No. 18.00:
INCOMING:-
(i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame type,Confirms to IS/IEC60947-2 (Make:Havells / ABB / Legrand / Siemens / LT)
(iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.
(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos
(iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No
(v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No.
(vi) Aluminium bus bar 400 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUTGOING:-
(i) MCCB 100 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) 50%, frame type,Confirms to IS/IEC60947-2 = Qty 02 Nos (Make: Havells/ABB/Legrand/Siemens/LT)
(ii) MCCB 63 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) 50%, frame type,Confirms to IS/IEC60947-2 = Qty 01 Nos (Make - Havells/ABB/Legrand/Siemens/LT)
-
-
-
Supply, install, testing and commissioning of LT panel size 80 cm x 80 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
1
-
-
Notes for Serial Item No. 19.00:
INCOMING:-
(i) MCCB 160 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame type,Confirms to IS/IEC60947-2 (Make: Havells/ABB/Legrand /Siemens/LT)
(iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three.
(iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos
(iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm-01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm – 01 No.
(vi) Aluminium bus bar 400 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING:-
(i) MCCB 63 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Ics =100% Icu* at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2 =Qty 04 Nos (Make - Havells/ABB/Legrand/Siemens/LT)
-
-
-
Supply, erecting, connecting and testing of LT bus bar chamber in cubical housing cabinet, outdoor type, platform mounted (minimum height 45 CM above normal GL and 30 CM below normal GL) angle iron frame grouted in PCC foundation , factory made, totally enclosed, dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 600 x 600 x 450 MM and full built upon angle iron frame in size 40 x 40 x 5 MM, having front and rear hinged both side open able doors and lifting lugs (02 Nos) , locking arrangement to be connect to earthing strip at rear side, bottom detachable both side open able ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment painted epoxy powder coated comprising 04 Nos Aluminium conductor equal size 600 Amps rated colour sleeve insulated bus bar mounting on heat shrinkable insulator both side incl grouting in PCC foundation including taking down existing material complete all as specified and directed.
1
-
-
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
2
-
-
Notes for Serial Item No. 21.00 :-
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.
(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.
(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
-
-
-
Supply, jointing, commissioning and testing in replacement heat shrinkable end termination /straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 95/120 Sqmm (earthed) complete all as specified and directed.
Make: Dension/3M/Rahycam
3
-
-
Supply and fixing Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 250 Amps, rated Ultimate Shortcircuit Breaking Capacity 35 KA Icu at 415 V (kA rms thermal & magnetic adjustable type, (Ics = 100% Icu)415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB from site complete all as specified and directed.
2
-
-
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.
(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
-
-
-
Evaluation Notes How It Works ?