Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date16 Dec 2022
Closing Date9 Jan 2023
Tender Amount₹ 48,03,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in fdn filling and mass concrete complete all as specified and directed.

12

-

-

... More
M & L for TMT 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, beam and Fdn, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips complete all as specified and directed.

2490

-

-

... More
M & L for TMT 5mm dia and over, upto 10mm dia in stirrups/ties, spacers and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns/beam, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips complete all as specified and directed.

1140

-

-

... More
M & L for flat, Rough finished formwork to sides of concrete foundations, footings, plinth beam, bases of columns, raft similar work etc.including supports.complete all as specified and directed.

85

-

-

... More
M & L for Square, Circular & rectangular, Rough finished formwork to sides of pillars,posts, struts, piers, columns, similar work etc. including supports.complete all as specified and directed.

120

-

-

... More
M & L for flat Rough finished formwork to plinth/ lintel beam, soffits, roof beams, lintels, cantilevers, shelves, similar work etc. including supports complete all as specified and directed.

36

-

-

... More
M & L for RCC (mix with mixture machine) Type B1 1:2:4 (20mm graded stone aggregate) in foundations including rafts, footings foundation beams plinth beams, bases for coloumns complete all as specified and directed.

17.5

-

-

... More
M & L for RCC (mix with mixture machine) Type B1 1:2:4 (20mm graded stone aggregate) in column, pillars, piers, posts,similar work etc.complete all as specified and directed.

13.92

-

-

... More
M & L for RCC (mix with mixture machine) Type B1 1:2:4 (20mm graded stone aggregate) in plinth Beams, lintel/roof beam, similar work etc.complete all as specified and directed.

2.1

-

-

... More
M&L for brickwork with fly ash brick (old size) built in CM 1:6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed.

86.5

-

-

... More
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 cm in soft loose soil complete all as specified and directed.

25

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

72

-

-

... More
Spreading and levelling (Soil) in layers n exc. 25, well ramming including watering as required, complete all as specified and directed.

72

-

-

... More
M&L for moorum/red bajri filling in floors/sub base or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed incl watering complete all as specified and directed.

22.9

-

-

... More
M & L for hard core of broken stones or boulders of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified.

22.08

-

-

... More
M & L for PCC 1:5:10 (75mm thick) Type E-2 using 40 mm graded aggregated as in floor & subbase, similar work etc.complete all as specified and directed.

16.8

-

-

... More
M&L for 30 mm thick cement concrete type B0 1:2:4 using 12.5mm graded aggregate as in floor complete all as specified and directed

168

-

-

... More
M&L Machine cut kota stone with white marble strip 20-25 mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing over 20mm thick screed bed in CM (1:4) as in floor complete all as specified and directed.

192

-

-

... More
M & L for Machine cut & polished smooth surface of kota stone slab 18-20mm thick as in skirting, including 10 mm thick rendering cement mortar 1:4 position etc complete all as specified and directed.

15

-

-

... More
M&L roof truss (framed) trussed, purlins, crane gantries, rails and fasterning and heavy bracket framing (Beam, tee, angle, M S plates etc including steel primer coat, welding, distnace pieces cleats etc confirming to Fe290 grade E-165.complete all as specified and directed.

1170

-

-

... More
S&F rolled section as in main and cross beams hip and angle, jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc including steel primer coat, welding, confirming to Fe290 grade E-165.complete all as specified and directed.

1640

-

-

... More
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, washer as specified.complete all as specified and directed.

495

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet for ridges 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, washer as specified.complete all as specified and directed.

40

-

-

... More
M&L for 4 mm thick non asbestos fibre cement building designer boards fixed in ceiling or laid/inserted to fiber/GI/aluminun frame.complete all as specified and directed.

265

-

-

... More
S & F Gl frame work size 605x605 mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners or 6 mm dia G.I. Hangers adjusting level fixed to roof truss/purllin in any height and including ceiling section of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre, complete all as specified and directed by Engr-in-charg.

265

-

-

... More
S & F steel windows with side hung shutters with using 'Z' steel section without glazing bars including projected box type hinges, tower bolt, steel handle, steel peg stay etc dovetailed or welded complete all as specified and directed by Engineer.

19.44

-

-

... More
S & F steel windows with side hung shutters using seel section with glazing bars including projected box type hinge, tower bolt, steel handle, steel peg stay etc dovetailed or welded complete all as specified and directed.

19.44

-

-

... More
S & F steel ventilators with top hung shutter with glazing bars, hinges, steel peg stay complete all as specified and directed.

4.36

-

-

... More
S&F framed work such as guard bars, grills, grating and guard bars etc and similar work including welding/reveting, fixing with screws, nut bolt etc complete all as specified and directed.

290

-

-

... More
S&F framed work such as hold fast and similar work including welding/reveting, fixing with screws, nut bolt etc complete all as specified and directed.

58

-

-

... More
S&F framed work of angle or other section in door frame etc and similar work including cutting/welding/reveting etc confirming to Fe-290 Ged E-165 complete all as specified and directed.

267.5

-

-

... More
M & L for 35 mm factory made 2nd class hard wood plain framed, panelled shutter (any no of panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces, size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated and fixed to frame, complete all as specified and directed.

21.6

-

-

... More
M & L for 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.

13.8

-

-

... More
S&F Soild PVC door frame of size 50mm x 47mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification.

24

-

-

... More
S&F Factory made solid PVC moulded door shutter 28 to 30 mm thick(stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specifications & drawings shown in section 8 of SSR Part II complete all as directed.

8

-

-

... More
S & F mild steel 300 mm, ordinary rat tail spring rod pattern springs (helical door spring) including roller and roller plate complete all as specified and directed.

4

-

-

... More
S&F Butt hinges, medium weight, cold rolled mild steel, and fixed (Size of hinges,125 mm) complete all as specified and directed.

39

-

-

... More
S&F 200 mm long Aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.

26

-

-

... More
S&F 150mm long alluminium handles, cast type, anodized and fixed complete all as specified and directed.

42

-

-

... More
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in door complete all as specified and directed.

8

-

-

... More
S & F 300 mm Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified and directed.

12

-

-

... More
S & F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed

27.28

-

-

... More
S & F 4 mm thick sheet/frosted glass, of selected quality, glazing with oil putty in squares, n exc 0.5 sq. m in each pane complete all as specified and directed.

15.6

-

-

... More
Description all as per above item but figured glass,pin head type complete all as specified and directed.

0.6

-

-

... More
M & L for two coat of synthetic enamel paint on new steel surfaces over one coat of red oxide primer including preparation of surfaces complete all as specified and directed.

60

-

-

... More
M & L for two coat of synthetic enamel paint on new wooden surface over one coat of pink primer including preparation of surfaces complete all as specified and directed.

50

-

-

... More
S & F Harrison rails, mild steel, chromium plated including brackets, stops, rollers etc complete all as specified and directed.

22

-

-

... More
M&L PCC 75 mm thick (1:3:6) type C-1 using 20 mm graded aggregate, plinth protection / sub base etc complete all as specified and directed.

122

-

-

... More
M & L for brickwork with fly ash brick, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.

40

-

-

... More
M&L for coloured Non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes. complete all as specified and directed.

123

-

-

... More
All as per above item but on verticle surfaces such as skirting/dado over 10 mm thich scread/rendering in cm 1:4. complete all as specified and directed.

4

-

-

... More
M&L for coloured glazed digital ceramic tiles in vertical surface Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick screed bed in CM 1:4 as in verticle surface etc complete all as specified and directed.

108

-

-

... More
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)

3

-

-

... More
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.

3

-

-

... More
S & F vitreous China wash basin, white, flat back, size 630x450mm including bracket complete all as specified and directed complete all as specified and directed.

3

-

-

... More
S & F for waste pipe for WHB / urinal, 32/40 mm dia complete all as specified and directed complete all as specified and directed.

6

-

-

... More
S&F vitreous China squatting pan, Orrissa pattern with integral foot rest size, 580x440mm white, any pattern all as spfd including concrete bedding complete all as specified and directed.

2

-

-

... More
S&F low level flushing cistern of capacity 10 litre ISI marked complete with inlet ball valve, connection to pipes and handle including connecting flush pipe, bracket etc of Commander/Hindware/ complete all as specified and directed.

2

-

-

... More
S & F 600mmx450mm bevelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.

3

-

-

... More
S & F chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.

3

-

-

... More
S & F for 15 mm bore, fancy type, chromium plated, pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, long screwed shanks and fly-nuts and fixed to pipe,complete all as specified and directed.

3

-

-

... More
S&F brass CP mixer (wash basin /wall ) 15 mm bore for mixing hot & cold water, screwed down for any type of pipe and fixed in any position and making good disturbed portion complete all as specified and directed.

3

-

-

... More
S & F 15 mm chromium plated Bib taps fancy type cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed (15mm bore dia of pipe) complete all as specified and directed.

6

-

-

... More
S & F 15 mm chromium plated Stop valves, fancy type (angle valve) cast copper alloy screwed down high pressure with crutch or but terfly handle screwed both ends for iron pipe or for unions and fixed (15mm bore dia of pipe ) complete all as specified and directed.

12

-

-

... More
S & F PVC connections 15 mm dia with PTMT nuts of length 750 cm complete all as specified and directed.

9

-

-

... More
S&F towel Rail 600 mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats.(Minimum weight 190gms) complete all as specified and directed.

3

-

-

... More
S & F grating doom 100/125 mm dia with waste hole/without waste hole of PTMT/ CP. (Minimum weight 40gms) complete all as specified and directed.

9

-

-

... More
S & F 75 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and directed.

12

-

-

... More
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed by the Engineer-in-charge.

5

-

-

... More
S & F 75 mm bore PVC (SWR) junction single (single T) equale or unequale complete all as specified and directed by the Engineer-in-charge.

2

-

-

... More
S & F 75 to 110 mm bore PVC (SWR) reduce complete all as specified and directed

2

-

-

... More
S & F rotational moulded polyethylene three layer water storage tanks with cover (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity of water tank 1000 litres complete all as specified and directed.

2

-

-

... More
S&F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule for 20mm bore dia of pipe complete all as specified and directed.

2

-

-

... More
S&F 15mm dia tubes medium grade galvanised, with all fittings and fixed complete, laid in floors/ wall complete all as specified and directed.

45

-

-

... More
S&F 20mm dia tubes medium grade galvanised, with all fitting and fixed complete, laid in floors/wall complete all as specified and directed.

67

-

-

... More
M & L for RCC (mix with mixture machine) Type B1 1:2:4 (20mm graded stone aggregate) in water tank slab, roofs, shelves, landings, balconies, similar work etc.complete all as specified and directed.

0.72

-

-

... More
M & L for flat, Rough finished formwork to slabs such as water tank slab, roof slabs, floor slabs, landings and similar work etc. including supports complete all as specified and directed.

7

-

-

... More
M&L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in coping, hold fast, gap filling of door frame, benching of MH, and similar work etc including necessary form work and all as directed.

2.19

-

-

... More
M&L for 15mm thick rendering in CM 1:6 on concrete, brick/stone surfaces of wall finished even and smooth without using extra cement, complete all as specified and directed.

676

-

-

... More
M&L for rendering 15 mm thick on concrete/ brick/stone surface wall in cement mortar 1:4 finished fair and even, complete all as specified and directed.

490

-

-

... More
Supply only integral water proofing compound (Liquid) complete all as specified and directed.

5

-

-

... More
M&L for applying two coats of oil emulsion distemper over a coat of 2mm thick wall care putty on newly plastered surface, complete all as specified and directed.

390

-

-

... More
M&L for applying two coats of cement based paint over a coat of primer on newly plastered surfaces including preparation, complete all as specified and directed.

305

-

-

... More
M&L for applying three coats of white/colour washing on newly plastered surfaces of wall including preparation complete all as specified and directed

96

-

-

... More
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior paint or apex (any colour) silicon based over a coat of water based suitable primering as a base course as per manufacturer's instructions including necessary scaffoldingcomplete all as specified and directed.

15

-

-

... More
S & F 110 mm bore dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenchesor in floors all as specified and directed.

28

-

-

... More
M & L for PCC 1:4:8 type D2 as in concrete bed 110mm bore of drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed.

27

-

-

... More
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed by the Engineer-in-charge.

3

-

-

... More
S & F 110 mm bore PVC (SWR) junction single (single T) equale or unequale complete all as specified and directed by the Engineer-in-charge.

2

-

-

... More
S & F 110 mm bore PVC (SWR) 'P' trap complete all as specified and directed

3

-

-

... More
M&L for pre-cast RCC slabs as in drain/manhole covers in 1:2:4 type B1 using 20 mm graded stone aggregate, set in cement mortar (1:4) incl use and waste of form work complete all as speciied and as directed.

0.15

-

-

... More
Cutting into existing manholes for connecting new 110mm dia drains pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required

1

-

-

... More
Dismantling timber scantlings 40 Sq. cm and over in section and in any position complete all as specified & directed.

0.4

-

-

... More
Dismantling cement( corrugated semicorrugated ,etc) sheets in roof covering including L type or J type hooks or cranked bolts etc complete all as specified and directed

213

-

-

... More
Demolition of brickwork built in cement mortar including all quoins arches pillar etc complete all as specified and directed.

18

-

-

... More
M&L brick work (old Size) in cm (1:6) straight or curved on plan exceeding 6.00 mtr mean radius complete all as specified and directed.

18

-

-

... More
Demolation of reinforced cement concrete roof,floor (other than ground floor) beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.

0.5

-

-

... More
M&L reinforced cement concrete nominal mix Type B1 1:2:4 in slab supported on walls, beam, and columns in floors, roof and the like all as specified and directed.

0.5

-

-

... More
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

360

-

-

... More
M&L for applying two coats of cement based paint on old decorated surfaces including preparation and complete removal of existing treatment complete all as specified.

20

-

-

... More
M&L for applying two coats of white/colour washing on old decorated surfaces including preparation and complete removal of existing treatment complete all as specified.

6

-

-

... More
M&L for applying two coats of oil emulsion distemper over a coat of 1mm thick wall care putty on old decorated surface including complete removal of existing treatment complete all as specified and directed.

15

-

-

... More
Roughening of surface of old concret floor by picking sweeping clean and washing down with water to remove dust etc complete all as specified and directed.

160

-

-

... More
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.

5

-

-

... More
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.

6

-

-

... More
S&F in repair stainless steel curtain rod 25mm dia including brackets,side knob and 8 Nos stainless steel curtain rings per meter lenth all as specified and directed.

9

-

-

... More
S & F in repair mild steel 300 mm, ordinary rat tail spring rod pattern springs (helical door spring) including roller and roller plate complete all as specified and directed.

2

-

-

... More
M & L for preparation of old steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.

25

-

-

... More
S&F Butt hinges, medium weight, cold rolled mild steel, and fixed (Size of hinges in 100 mm)complete all as specified and directed.

24

-

-

... More
Taking up or down 20 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.

12

-

-

... More
Taking up or down 15 mm bore dia steel tubing and connections, including removal to store/ site complete all as specified and directed.

10

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to encs or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wirings etc and making good sutting not exc 10 cm in girth in brick wall all as specified and directed.

5

-

-

... More
M&L in repair gun metal ,globe or gate valve 20 mm with iron wheel head ,screwed both ends for iron pipe complete all as specified and directed.

1

-

-

... More
S&F in repair Wash hand basin flat back 550x400mm vitreous chine (white) with cantilever brackets embedded in concrete block including the fiollowing and fixed in repairs complete all as specified and directed. (a) Brass chromium plated waste coupling 32mm bore (b) Waste pipe PVC 32mm bore (c) Angle iron/cast iron brackets (d) CP Fancy type pillar cock 15 mm dia

1

-

-

... More
S&F in repair looking mirror 600x450 mm selected quality 5mm mounted on 6mm ply wood and fixed with brass screw and cup washer.

1

-

-

... More
S&F in repairs Rotational moulded polyethylene water storage tanks with cover & 20mm ball valves high pressure of PTMT with epooxy coated aluminium road & high density plastic ball (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I (Capacity in litres 500) complete all as specified and directed.

1

-

-

... More
S&F in repair 75 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.

3

-

-

... More
S & F in repair PVC (SWR) Bend any radious of 75 mm dia

3

-

-

... More
S&F in repairs 75 mm dia of outlet CI floor trap, with grating incl jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed.

1

-

-

... More
M&L 20mm thick granite (of any type) tiles machine cut, in skirting/ dedo/ laid over cement screed and jointed with grey cement cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete.

5

-

-

... More
Demolition Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level)

10

-

-

... More
Dismentling wall and ceiling boards( fibre pulp, insulation etc.) or insulation board /slabs/blanket any thickness including cover fillets.

190

-

-

... More
M&L for vitrified light shade ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes

23

-

-

... More
M&L for vitrified light shade ceramic tiles on vertical surface 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick screed/rendering in cm 1:4.

2

-

-

... More
S&F solid PVC Wall lining consisting of 5mm thick plain but single side prelam PVC sheet used instead of plain light colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed. .

30

-

-

... More
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.

150

-

-

... More
M&L in repair machine pressed coloured chequered tiles 25 cm x 25 cm x 25 mm thick set, jointed & pointed in grey cement with pigment including 20 mm thick screed bed in CM 1:6. complete all as specified and directed.

50

-

-

... More
M&L 25 mm thick cement concrete 1:2:4 type B1 (20 mm graded aggregate) as in sub base. complete all as specified and directed.

50

-

-

... More
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.

64

-

-

... More
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium grade, concealed on wall portion and with stove enameled steel conduit medium grade on steel structural truse/ RCC roof ceiling portion surface type fixed with sadlles, screwes as per Engr practices of suitable size but not less than 20 mm bore with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.

123

-

-

... More
All as per item No-2 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch complete all as specified & directed.

14

-

-

... More
All as per item No-2 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed.

10

-

-

... More
All as per item No-2 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed.

2

-

-

... More
All as per item No-2 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 2 to 6 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)

8

-

-

... More
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed by Engineer in charge.

148

-

-

... More
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed.Make: Anchor Cat No.39991 or equivalent as approved by GE.

8

-

-

... More
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 voltscomplete all as specified and directed by Engineer in charge.

26

-

-

... More
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed by Engineer in charge.

8

-

-

... More
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed by Engineer in charge.

1

-

-

... More
S&F for ceiling rose surface bakelite 50 x 25 mm size 3 terminalscomplete all as specified and directed by Engineer in charge.

88

-

-

... More
Supply and fix lamp holder insulated body with back plate for batten fittingcomplete all as specified and directed by Engineer in charge.

15

-

-

... More
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Voltscomplete all as specified and directed by Engineer in charge..

10

-

-

... More
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified and directed by Engineer in charge..

1

-

-

... More
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed by Engineer in charge.

15

-

-

... More
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified and directed by Engineer in charge.

4

-

-

... More
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified and directed by Engineer in charge.

34

-

-

... More
Supply & fix, surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2X2 environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- PLR34WLED857S or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.

20

-

-

... More
Supply & fix, outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and directed by Engineer in charge.

12

-

-

... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in charge.

2

-

-

... More
Supply & fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and directed by Engineer in charge.

4

-

-

... More
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .

118

-

-

... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.

138

-

-

... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.

100

-

-

... More
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces.

8

-

-

... More
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 200 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply and fix MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB.complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 11 or equivalent model of make Siemens/ Schneider as approved by GE.

7

-

-

... More
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 63 Amps, IP-20 as per IEC 60947-3 ISI marked complete all as specified and directed by Engineer in charge..

1

-

-

... More
Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer in charge.

8

-

-

... More
Supply & fix MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified and directed by Engineer in charge..

24

-

-

... More
Supply & fix MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified and directed by Engineer in charge.

10

-

-

... More
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified and directed by Engineer in charge.

34

-

-

... More
M & L earthing complete in replacement with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .

4

-

-

... More
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in- Charge

10

-

-

... More
Supply laying, commisioning & testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.

60

-

-

... More
Supply & Laying, testing ,cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 16 Sqmm 4 core compele all as specified and as directed.

50

-

-

... More
Supply & Laying, testing ,cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 6 Sqmm 2 core compele all as specified and as directed.

10

-

-

... More
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.

26.24

-

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.

13.17

-

-

... More
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.

13.08

-

-

... More
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable.

846

-

-

... More
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.

9.19

-

-

... More
Supply and fixing in replacement GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,. Make :- TATA, Jindal, Prakash Surya

12

-

-

... More
Supply and fix ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.

24

-

-

... More
Supply and fix electric water heater, storage type steel body with fiber glass coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser all as specified and directed

1

-

-

... More
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.

3

-

-

... More
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 Ltrs per hour and storage capacity of 80 Ltrs with 2 Nos cold water outlet complete all as specified and directed.

1

-

-

... More
Supply and fix 'Medium Grade' galvanised iron tubes with all fittings such as tees bends elbow etc laid in trenches of 25 mm bore complete all as directed

35

-

-

... More
Supply and fix 'Medium Grade' galvanised iron tubes with all fittings such as tees bends elbow etc fixed on walls/ floors of 20 mm bore complete all as directed

12

-

-

... More
Supply and fix gun metal gate valve of size 20 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as directed

2

-

-

... More
Supply and fix gun metal gate valve of size 25 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as directed

1

-

-

... More
Supply and fix PVC ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 20mm bore complete all as directed

2

-

-

... More
Material and labour for Drilling and tapping cast iron water mains (in position) for branch connections of the internal 20 mm dia complete all as directed.

1

-

-

... More
M&L for Straight plain brass ferrules (or connecting screws) screwed both ends and fixed Bore Diameter of pipe in 20 mm

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.