Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Nov 2023
Closing Date26 Dec 2023
Tender Amount₹ 42,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down of old MCCB and S & F MCCB, 4 pole, 160 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 50 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .

12

-

-

... More
Taking down of old MCCB and S & F MCCB, 4 pole, 200 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 75 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .

6

-

-

... More
Taking down of old MCCB and S & F MCCB, 4 pole, 250 Amps, Icu=35KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, for 75 HP motor all as specified and directed. Note: MCB/MCCB/and DBs shall be of same make .

4

-

-

... More
S & F in replacement Aluminium thimble suitable for LT Aluminium cable of size up to 90 Sqmm, 3.5 core complete all as spercified and directed.

122

-

-

... More
S & F in replacement Copper thimble suitable for LT copper cable of size upto 35 Sqmm, 3.5 core complete all as spercified and directed.

200

-

-

... More
Supplying, fixing and testing in replacement 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.

5

-

-

... More
Supplying, fixing and testing in replacement 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.

4

-

-

... More
Supplying, fixing and testing in replacement 315/320 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.

2

-

-

... More
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 22.5 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.

2

-

-

... More
Dismantiling electric motor carefully from borehole after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 50 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.

10

-

-

... More
Dismantiling electric motor carefully from boreholel after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 75 HP, 3 phase, 400/ 415 volts, 50 Hz of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.

1

-

-

... More
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 75 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .

1

-

-

... More
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 50 to 60 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .

10

-

-

... More
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 20 to 22.5 HP 3 phase, 400/ 415 volts, 50 Hz of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .

2

-

-

... More
Lifting of electric motor 22.5 HP to 75 HP capacity from existing position after disconnection of all electrical connection for renewal of U/S bearing and applying grease after removal of old grease and re-installing at site where directed after refilling new grease and reconnecting all electrical connection and testing complete. Note : (a) Necessary payment for bearing shall be measured and paid separately under relevant items if required at site. (b) Quoted rate deemed to include cost of grease as required at site. (c) The contractor shall lift the motors as directed by the dept for normal servicing even if no repairs are reqd for the motor.

13

-

-

... More
Renewal of Thrust bearing No. 7220 including dismantling/taking out unserviceable thrust bearing of any make for 50 HP motor, complete all as specified and directed.

10

-

-

... More
Renewal of Thrust bearing No. 7316 including dismantling/taking out unserviceable thrust bearing of any make upto 75 HP motor, complete all as specified and directed.

2

-

-

... More
Renewal of Thrust bearing No. 29324 including dismantling/taking out unserviceable thrust bearing of any make for 75 HP motor, complete all as specified and directed.

2

-

-

... More
Renewal of Ball bearing No. 6312 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP motor, complete all as specified and directed.

3

-

-

... More
Renewal of Ball bearing No. 6316 including dismantling/taking out unserviceable thrust bearing of any make Upto 50 HP motor, complete all as specified and directed.

4

-

-

... More
Renewal of Ball bearing No. 6311 including dismantling/taking out unserviceable thrust bearing of any make for 50 HP motor, complete all as specified and directed.

3

-

-

... More
Renewal of Ball bearing No. 6313 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP motor, complete all as specified and directed.

3

-

-

... More
Renewal of Ball bearing No. 6309 including dismantling/taking out unserviceable thrust bearing of any make Upto 22.5 HP motor, complete all as specified and directed.

2

-

-

... More
M & L for bearing sheet of motor of capacity up to 75 HP motor including lathe work, brazing etc complete all as specified and directed.

8

-

-

... More
Labour for lifting of VT pump along with flanged column pipe, line shaft , spider, rubber bush etc from the existing bore well by using suitable T&P etc after disconnecting VT motor making necessary repairs by opening and renewal of parts as required including transportation to market and back for repair complete all as specified & directed for up to 40000 GPH capacity pumpset and any size. Note: Parts Renewed shall be measured and paid separately

8

-

-

... More
Dismantling carefully turbine pump set bowl assembly of any make, capacity upto 40000 GPH and size complete with out damaging any parts of the pump and setting aside in pump house for ascertaining the serviceability of existing parts with the following :- (a) Through dismantling and cleaning of complete bowl assembly items such as CI bowls, impeller, lock collets, bowl bush, suction and discharge case with GM bush including pump shaft. (b) Cleaning of all rotary and stationary parts of pump bowl assembly and making them for their satisfactory run. (c) Re-assembling the complete bowl assembly pump with all existing serviceable parts and renew the worn out unserviceable parts including S & F gasket ,lathe work and balancing of assembly others small nature of indispensable items as required for repairing. Note :- Parts renewed shall be measured and paid for separately under respective item of Schedule 'A'/BoQ at supplied only rates. Cost of labour for fixing of new parts shall be deemed to include in the rate quoted by tenderer.

8

-

-

... More
Replacement of old damaged CI centrifugally cast bowl assembly complete with gun metal bush ( make as per original manufacturer) for pump of capacity up to 40000 GPH of vertical turbine pump .

36

-

-

... More
Replacement of old damaged GM impeller ( make as per original manufacturer) for vertical turbine pump of capacity up to 40000 GPH of any type.

40

-

-

... More
Replacement of old damaged Stainless steel non magnetic pump shaft 25 to 32 mm ( make as per original manufacturer) dia suitable for 6 to 9 stage pumps (Bowl assembly) as directed .

10

-

-

... More
Replacement of old damaged M.S. line shaft (bright) steel 25 to 32 mm dia 10 Ft long with MS coupling and non magnetic stainless steel sleeve ( make as per original manufacturer) all as specified and directed.

38

-

-

... More
Replacement of old damaged Shaft coupling, reduser coupling / sleeve of high carbon steel for 25 mm to 32 mm dia lineshaft (make as per original manufacturer) all aspecified and directed.

12

-

-

... More
Replacement of old damaged GM Bush for suction case of VT pump ( make as per original manufacturer) all aspecified and directed.

24

-

-

... More
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 150 mm bore pipe ( make as per original manufacturer) all aspecified and directed.

40

-

-

... More
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 200 mm bore pipe ( make as per original manufacturer) all aspecified and directed.

25

-

-

... More
Replacement of old damaged Rubber packing for discharge head upto 300 mm bore complete all as specified ( make as per original manufacturer) all aspecified and directed.

10

-

-

... More
Replacement of old damaged Rubber bush for guide spider for 25 to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.

60

-

-

... More
Replacement of old damaged Stainless Steel top shaft not exceeding 32 mm dia and 3 mtr long, duly threaded both ends and made suitable slot for fixing the stainless steel key adjusting nut & lock washer ( make as per original manufacturer) all aspecified and directed.

14

-

-

... More
Replacement of old damaged CI Centrifugally cast suction case with GM Bush (make as per original manufacturer) all aspecified and directed.

8

-

-

... More
Replacement of old damaged CI Centrifugally cast discharge case with GM Bush ( make as per original manufacturer) all aspecified and directed.

8

-

-

... More
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 100 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge

8

-

-

... More
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 150 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge

27

-

-

... More
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 200 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge

16

-

-

... More
Replacement of old damaged Ratchet assembly complete with ratchet plate, ratchet balls hexagonal bolts etc suitable for up to 75 HP electric motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

12

-

-

... More
Replacement of old damaged Ratchet plate suitable upto 75 HP VT motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed..

5

-

-

... More
Replacement of old damaged GM neck ring suitable for 100mm/150mm/200m dia VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

24

-

-

... More
Replacement of old damaged PVC rubber Gasket 3 mm thick suitable upto 200 mm bore flanged joints .

120

-

-

... More
Replacement of old damaged Rubber bowl bush suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

24

-

-

... More
Replacement of old damaged Intermediate bowl bush GM suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

30

-

-

... More
Replacement of old damaged GM Impeller lock collect suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

25

-

-

... More
Replacement of old damaged CI fitting box (Gland box) with clamp of suitable type & shape for VT Pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

12

-

-

... More
Replacement of old damaged Mild steel full threaded bolts of suitable size having hexagonal head with one 3 mm thick washer and nut suitable for jointing 100/150/200 mm bore flanged joints complete all as specified.

350

-

-

... More
Replacement of old damaged Gun Metal split gland of any size & shape with G I clamp suitable for gland box of VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.

24

-

-

... More
Lowering of turbine pump set any type and capacity upto 40000 GPH re-assembling of all accessories and column pipe, line shaft etc after cleaning manually and adjustment of pump load etc and testing of pump and motor after installation all as directed by Engr-in-Charge.

8

-

-

... More
Cutting, facing of existing mild steel cold drawn ERW column pipe upto 200 mm dia to desired length and re-threading up to 80 mm run to suit existing coupling complete all as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.

13

-

-

... More
Cutting, facing of existing mild steel lineshaft up to 32 mm dia to desired length and re-threading up to 80 mm run as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.

14

-

-

... More
Cutting existing MS/BS/SS top shaft of size upto 32 mm dia making slot for key and rethreading both ends for required length to suit the coupling and load adjusting shaft nut all as directed by EIC.

2

-

-

... More
Taking out rusted after disorienting old worn pump M S foundation bolt from cement concrete foundation base and fixing by providing new mild steel full threaded bolt of 20 mm dia not exc.300 mm long with proper cement concrete foundation (1:2:4) type B-1 using 20mm graded crushed stone aggregate and makeing the surface smooth to match with existing surface complete all as directed.

6

-

-

... More
Repairing the base of discharge head of VT pump up to 40000 GPH by Welding and renewing high carbon steel nut for the base of discharge head, including renewal of mild steel channel complete all as directed.

4

-

-

... More
Renewal of Heavy duty terminal plate made of bakelite suitable for electric motor of capacity 30/40/50/75 HP with brass nuts of suitable size best quality as approved by GE complete all as specified and directed.

4

-

-

... More
Renewal of Terminal plate cover made of CI for fixing over the terminal plate with cover for 30/40/50/ HP electric motor best quality as approved by GE complete all as specified and directed.

4

-

-

... More
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation to market and back for repair complete all as specified & directed for 22.5HP to 41 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately

6

-

-

... More
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening and renewal of parts as required including transportation complete all as specified & directed for 2HP to 7.5 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately at supplied only rates under appropriate item(s).

2

-

-

... More
Supply only Gunmetal impellers suitable for 22.5 to 41 HP Submersible pump

12

-

-

... More
Supply only Gunmetal bush suitable for 22.5 to 41 HP Submersible pump

12

-

-

... More
Supply only stainless steel sleeve suitable for 22.5 to 41 HP Submersible pump

12

-

-

... More
Supply only 'C' type bushes for impellers suitable for 22.5 to 41 HP Submersible pump

12

-

-

... More
Supply only Bowel case suitable for 22.5 to 41 HP Submersible pump

12

-

-

... More
Supply only stainless steel shaft of standard size complete in all respect suitable for 22.5 to 41 HP Submersible pump

6

-

-

... More
Supply only Gunmetal impellers suitable for 2 to 7.5 HP Submersible pump

4

-

-

... More
Supply only Gunmetal bush suitable for 2 to 7.5 HP Submersible pump

4

-

-

... More
Supply only stain less steel sleeve suitable for 2 to 7.5 HP Submersible pump

4

-

-

... More
Supply only 'C' type bushes for impellers suitable for 2 to 7.5 HP Submersible pump

4

-

-

... More
Supply only Bowel case suitable for 2 to 7.5 HP Submersible pump

4

-

-

... More
Supply only stainless steel shaft of standard size complete in all respect suitable for 2 to 7.5 HP Submersible pump

2

-

-

... More
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 22.5 HP to 41 HP capacity pumpset.

6

-

-

... More
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 2 HP to 7.5 HP capacity pumpset.

2

-

-

... More
Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaling ,removal of old winding wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 22.5 HP to 41 HP capacity of pump motors. Note: Other parts required for repair will be measued and paid for separately under respective sch item.

8

-

-

... More
Supply only Gunmetal bush for submersible motor suitable for 22.5 to41 HP

23

-

-

... More
Supply only Thurst bearing for submersible motor suitable for 22.5 to 41 HP

12

-

-

... More
Lifting out and Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaling ,removal of old wiring wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 02 HP to 7.5 HP capacity of pump motors. Note: Other parts required for repair will be measued and paid for separately under respective sch item.

2

-

-

... More
Supply only Gunmetal bush for submersible motor suitable for 2 to 7.5 HP

4

-

-

... More
Supply only Thurst bearing for submersible motor suitable for 2 to 7.5 HP

4

-

-

... More
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed,3 core,16 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.

180

-

-

... More
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed,3 core,10 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.

160

-

-

... More
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed,3 core, 06 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.

150

-

-

... More
Supply & fix Single/reverse phase preventor for motor protection with by pass arrangements to run the motor in case of emergency with low/high voltage cut off and time delay/relay of 1 to 3 sec.including dismantling/taking out of unserviceable phase preventor of any make and type complete all as specified and directed.

12

-

-

... More
Taking down and S&F Thermal Over load relay of range 65 to 110 Amps (for 3 phase,415 V motor of 75 HP) complete all as specified.

6

-

-

... More
Taking down and S&F Over load relay of range 45 to 75 Amps (for 3 phase,415 V motor of 50 HP) complete all as specified.

8

-

-

... More
Taking down and S&F Thermal Over load relay of range 28 to 36 Amps (for 3 phase,415 V motor of 22.5 HP) complete all as specified.

3

-

-

... More
Supply & Fixing of Power contactor 3 pole above 50 HP upto 75 HP with 415 V/220 V , AC Coil including repair/replacement of wiring complete all as specified.

6

-

-

... More
Supply Power contactor 3 pole upto 50 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.

18

-

-

... More
Supply Power contactor 3 pole upto 30 HP with 415 V/220V , AC Coil including repair/replacement of wiring complete all as specified.

6

-

-

... More
Supply only Thermal timer type GT 200, including wiring operating voltage 230/250 Volts, 400/440 Volts, 50 Hz fun 5-18 seconds range complete all as specified.

4

-

-

... More
S & F in replacement phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of wiring as required to made the sequencer serviceable condition.

6

-

-

... More
Taking down of RYB phase indicator and S & F of RYB phase indicator of any size and type on LT Panel as specified and directed.

20

-

-

... More
S & F in repairs Digital Ampere meter 96 mm square flush mounted type 0-200 Amp,3 phase all as specified.

12

-

-

... More
S & F in repairs Digital volt meter 96 mm square flush mounted type 0-500 volts, 3 phase with selector switch all as specified.

12

-

-

... More
Supply,fixing,testing and commissioning in replacement of Motor Protection Circuit Breaker (MPCB) for motor capacity 20HP to 75HP 3 POLE/4 POLE to include features of protection/tripping from over current, under current, high voltage/low voltage, dry run, earthing, over-load, short circuits, thermal protection as directed by engineer in charge. (MAKE Schneider,Simens, L&T, ABB or equivalent)

6

-

-

... More
Taking Up/ down requmended BER submersible motor set up to 40HP including pump set up to 30000 GPH ( 5 to 7 stage) & depositing to store as directed by Engr-in-Charge.

3

-

-

... More
Supply ,install,, testing and commissioning submersible pump,35 HP, Cap 12000 GHP, 70 Mtr Head electric driven 415 V, TP suitable for 150 mm dia bore well (Casing pipe size 250/300mm) complete all as specified and directed.

1

-

-

... More
Supply ,install,, testing and commissioning submersible pump,30 HP, Cap 10000 GHP, 70 Mtr Head electric driven 415 V, TP suitable for 150 mm dia bore well (Casing pipe size 250/300mm) complete all as specified and directed.

2

-

-

... More
Repair/replacement of motor gland leakage including replacement of studs, plate, and other assessories/ items all as directed by Engr-in-Charge.

14

-

-

... More
S&F (in repair/replacement) of fully automatic ,3 phase Star delta starter with enclosure suitable for motor upto 50HP capacity including connector & cables required all as directed by Engr-in-Charge.

3

-

-

... More
S&F (in repair/replacement) of fully automatic ,3 phase Star delta starter with enclosure suitable for motor above 50HP upto 75HP capacity including connector & cables required all as directed by Engr-in-Charge.

2

-

-

... More
M & L for repair of LT panel body its doors & covers by suitable means of including cutting, welding, and sheet metal work up to 1 Sqm in replacement as required and directed by Engr-in-Charge. Including and steel primer on new/ repaired surface painting the entire panel after repairs using expoxy powder coated paint.

6

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1, pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . (Concrete pit shall be 20 cm to 30 cm away from main pit).

6

-

-

... More
Repair to phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the sequencer serviceable condition.

4

-

-

... More
S & F in renewal of digital type 3 Phase, 415V , 50HZ electronic energy meter at various pump Houses and direct connected 5/20Amp CT, 10/60Amp CT operated direct reading type meter with indication LCD having accuracy wide voltage fluctuation from -40% to +20% and should give accurate reading under rapid current fluctuation and accurate for balance as well as unbalance load including anti tamper feature complete all as specified and directed.

2

-

-

... More
Taking down old unserviceble No-NC based automatic motor Cut-off relay based on water level of OHT and S&F New No-NC based water level controlled auto motor Cut-off relay including testing &commissioning as directed by Engr-in-Charge.

2

-

-

... More
M&L new transformer oil in servo voltge stabilizer to fulfil upto required level. Note: break down value of transformer oil should not be less than dielectric strength 50 KV .all as specified.

200

-

-

... More
M&L for dehydration / filteration of transformer oil in servo voltage stabilizer breakdown value of transformer oil should not less than dielectric strength 50 KV including draining out and refilling in Transformer/ Stabilizer . Note : Contractor will arrange filtration plant machine at site of voltage stabilizer transformer oil dehydration work will be carried out in working condition all as specified.

500

-

-

... More
Disconnecting & taking out/opening of the non-functional 3 phase servo voltage stabilizer of any description in any position for taking out unserviceable / defective wiring & parts, cleaning and servicing complete including renewal of unserviceable parts complete, draining-out of transformer oil for repair work renewal of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testing complete all as specified and directed by Engineer-in-Charge for three phase 50 to 75 KVA capacity . Notes :- (i) Parts renewed shall be measured and paid for separately under appropriate item of Sch ‘A’ at supply only rates but fixing of the parts replaced/repaired/Renewed is deemed to be included in this item. (ii)Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Tenderer Quoted rate shall be deemed to include for all transporting charges including loading/unloading to workshop and back where required complete all as specified.

5

-

-

... More
Supply only Micro toggle switches all as specified.

4

-

-

... More
Supply only Auto manual switches . all as specified.

3

-

-

... More
Supply only high and low voltage indicator light complete all as specified.

4

-

-

... More
Supply only panel indicator light for main "ON' indication all as specified.

4

-

-

... More
Supply only push button all as specified.

4

-

-

... More
Supply only potential meter all as specified.

3

-

-

... More
Supply only Electronic sensing card (Printed circuit Board all as specified.

3

-

-

... More
Supply only 12 pin connector all as specified.

3

-

-

... More
Supply only rotary mechanism of dimmer through armature motor for capacities of stabilizers 03 phase up to 75 KVA all as specified.

4

-

-

... More
Supply only Servo motor 10 kg torque all as specified.

4

-

-

... More
Supply only RC network for servo motor 10 KG all as specified.

3

-

-

... More
Supply only voltage selection arm of auto transformer up to 75 Amps with carbon bush all as specified.

3

-

-

... More
Supply only Trigger Transformer 440 V to 220 V all as specified.

3

-

-

... More
M&L for rewinding of Buck booster transformer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for three phase 50 to 75 KVA capacity of stabilizers all as specified.

4

-

-

... More
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 50 KVA capacity of stabilizers all as specified.

4

-

-

... More
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 75 KVA capacity of stabilizers all as specified.

3

-

-

... More
Renewal of Insulators, vitreous, suitable for voltage stabilizers up to 160 Amps current rating, complete all as specified.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.