Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date30 Oct 2024
Closing Soon20 Nov 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of brick work or stone masonry including all quoins, arches, pillars etc built in CM complete all as specified & directed.

3.3

-

-

... More
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified & directed.

1

-

-

... More
M&L brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified & directed.

20

-

-

... More
Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.

1100

-

-

... More
M&L for 15mm thick plastering in CM 1:6 on brick surfaces of walls & finishing the surface even & fair complete all as specified and directed.

100

-

-

... More
Material & labour 10 mm thick rendering in CM 1:4 concrete surfaces of ceiling etc, finished surfaced even & smooth without using extra cement complete all as specified & directed.

100

-

-

... More
M&L for 15mm thick plastering in CM 1:4 on brick surfaces of walls & finishing the surface even & smooth with water proofing compound as per manufacture instructions (including necessary arrangements in multy storey bldgs up to G+2) complete all as specified and directed.

900

-

-

... More
M&L for two coats of OBD over a coat of average 2 mm thick wall care putty on newly plastered surfaces of walls complete all as specified and directed.

100

-

-

... More
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer at any height (n.exc 11m) incl necessary scaffolding /centreing etc complete all as specified and directed.

900

-

-

... More
Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash to match the existing as required, complete all as specified & directed.

100

-

-

... More
Disconnecting existing water storage tanks 500 ltrs to 1000 ltrs capacity, setting aside (for lowering if required) for repair, cleaning ,etc and hosting if required reconnecting and refixing in position including cleaning, removing all scale dirt etc form tanks and from mouths of circulating pipe, replacement old tank nipple, unions, stop cock, tank cover etc complete all as specified and as directed.

12

-

-

... More
S & F in repair for 500 Litres capacity rotational moulded poly ethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I with & including PVC Float valve 20mm bore, Tank cover, wash out and overflow pipe necessary tank nipples complete all as specified & directed.

3

-

-

... More
Taking up or down 15 mm bore steel tubing/CPVC pipe including fittings and connections, including cleaning for refixing or removal to store complete all as specified & directed.

50

-

-

... More
S&F 15 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed.

50

-

-

... More
Taking up or down 20 mm bore steel tubing/ PPR pipe including fitting and connections, including cleaning for Refixing or removal to store complete all as specified & directed.

600

-

-

... More
S&F 20 mm bore Galvanized Steel tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed.

600

-

-

... More
S&F in repairs 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed.

30

-

-

... More
S&F in repair 20 mm dia PVC float Valves high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule complete all as specified & directed.

50

-

-

... More
Taking down PVC pipe ( Soil waste pipe and rain water pipe) etc of any type/ size pipes (any size or pattern), including all fittings and clamp etc complete all as specified & directed.

460

-

-

... More
S&F 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls in lieu of old U/s PVC pipe including making good disturb portion to match the existing complete all as specified & directed.

100

-

-

... More
S&F 75 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls in lieu of old U/s PVC pipe including making good disturb portion to match the existing complete all as specified & directed.

80

-

-

... More
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturb portion to match the existing complete all as specified & directed.

10

-

-

... More
S&F 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturb portion to match the existing complete all as specified & directed.

8

-

-

... More
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and jointed with cement joint including making good disturb portion to match the existing complete all as specified & directed.

10

-

-

... More
S&F 75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturb portion to match the existing complete all as specified & directed.

3

-

-

... More
S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.

120

-

-

... More
S&F PVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints fixed complete all as specified and directed .

160

-

-

... More
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.

12

-

-

... More
S&F in repairs PVC (SWR) bends any radius 75mm dia complete all as specified & directed.

12

-

-

... More
S&F clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 100 mm bore pipe (including necessary arrangements in multy storey bldgs up to G+2) complete all as specified & directed.

45

-

-

... More
S&F clamps out of 50 mm by 5 mm flat iron fixed with suitable bolt / screws securing ends of stays to wall or roof for PVC (SWR) / CI Pipe for 75 mm bore pipe (including necessary arrangements in multy storey bldgs up to G+2) complete all as specified & directed.

50

-

-

... More
M&L in repair 3mm thick ordinary quality sheet glass n.exc 0.5 sqm each but figured glass fix in ventilatior, pin head type complete all as specified and directed.

30

-

-

... More
Dismantling AC sheets corrugated or semi corrugated plain in roof coverings complete all as specified & directed.

466.3

-

-

... More
S& F 6mm thick asbestos cement, corrugated or semi corrugated sheets in roofs , walls etc fixed with J type hook botls, complete all as specified & directed.

80

-

-

... More
Fixing only 6mm asbestos cement sheets corrugated or semi corrugated sheets in roofs, walls etc fixied with J type hook bolts complete all as specified & directed. (Note : Serviceable sheets obtained from item No 41 above can be used for fixing)

25

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel steet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws with neoprene and EPDM washers including dismantling of existing asbestos corrugated sheets in single storey bldgs complete all as specified and directed.

367

-

-

... More
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screws including dismantling the asbestos plain ridge portion or valley gutter etc complete all as specified and directed.

19.3

-

-

... More
Removing or dismantling of damage / cracked/ concrete /loose concrete / plaster of celing/ wall/ chajja/ facia to expose the sound and hard concrete using a suitable mechanical device or by hammer and chisels etc complete all as specified & directed.

350

-

-

... More
M & L for applying bonding agent for bonding old to new concrete surface likes chajja/ beams/ celings/ columns/ facia etc by high performance modified Styrene- Butadiene Rubber (SBR) base binder . Applying of binder is as 10 sqm/ per litr (including necessary arrangements in multy storey bldgs up to G+2) etc complete all as specified & directed.

350

-

-

... More
M & L for applying 15 mm thick ( average ) smart care repair mortar ready to use single component polymer modified repair mortar for repair of RCC members likes beams, columns, chajja, facia, mortar having good compressive strength and shrinkage resistance, mixing as per manufacture instruction etc (including necessary arrangements in multy storey bldgs up to G+2) complete all as specified & directed.

350

-

-

... More
S&F galvanised welded steel wire fabric as extra reinforcement to RCC members like ceilings, chajja’s, beams, columns parapet walls, waste slab etc including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed.

100

-

-

... More
Supply and fix anodized aluminium snap grid frame work with size of grid 605x605mm made out of aluminium ‘T’ section as main runner/ cross Tee and ‘L’ angle as wall angle for false ceiling including 4mm dia suspender, making position for light fittings, including provision of 4mm thick non asbestos fibre cement building, E-board (decorative) , fixed or laid/ inserted to timber/GI/ aluminium frame work with screw including dismantling of old unserviceable asbestos cement plain building boards and grid of any type complete all as specified and as directed.

50

-

-

... More
Dismantling unframed work timber scantling 40 Sqcm and over in section complete all as specified & directed.

2

-

-

... More
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 Gde E165 complete all as specified & directed.

450

-

-

... More
S & F in repair framed work such as grills , gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors : ladders:framed balusters: walk ways: railings: framedwork of water tanks and similar work conforming to Fe-290 Gde E165 ( For old existing rungs ).etc complete all as specified and directed

500

-

-

... More
M&L preparation of newly surface of iron/steel with two coat synthetic enamel paint over a coat of red oxide primer etc complete all as specified & directed.

50

-

-

... More
M&L for PCC 1:2:4 Type B1 ( using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight, copings, kneelers, apex stones bed plates, kerbs chajjas , water troughs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, fixing of chain link fencing etc all as directed incl necessary formwork etc complete all as specified and directed.

1.5

-

-

... More
Material & Labour for Preparation of old plastered surfaces of walls including brooming , scrapping down. Smoke spot, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks by applying putty in patches as required and applying applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior on facia , chazza, Col projected face area width no exc 45cm of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat on exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.( including necessary arrangements in multy storey bldgs up to G+2 ) etc complete all as specified & directed.

250

-

-

... More
Taking down of old roof treatment of any description including mud phushka, lime concrete, tiles, cement plaster from roof surfaces etc including cleaning ,brushing and watering to joints and grooves and throwing the same to a distance exc. 250 mtr and not exc 500 mtr from the roof of height 3 to 9 mtr etc complete all as specified and directed.

1142

-

-

... More
M&L 25 mm thick PCC 1:2:4 type B-1 (12.5mm graded aggregate) with water proofing compound as per manufacture instructions neat cement slurry with 3.0kg of cement per Sqm complete all as specified and as directed. Note : water proofing compound shall be measured and paid separately.

1142

-

-

... More
Supply only Water Proofing Compound complete all as specified & directed.

25

-

-

... More
M & L providing and applying PU Roofkoat, single component, cold applied, water based polyurethane highly elastic and UV resistant waterproofing treatment to the roof @ 1.7-1.8 Kg/m2 conforming to ASTM D6083-97A with a density of 1.25-1.3 Kg/Litre, having tensile strength of 1.5N/mm2, having elongation of 350% with solid content not less than 60% in 4 coats including self-priming of the same material after dilution of water at 50% and spreading 160 gsm Geo-textile after 2 coats of PU Roofkoat giving gap of minimum 4-6 hours and after that further coated with 2 coats of PU Roofkoat undiluted complete all as specified & directed.

1142

-

-

... More
M & L for Removing all vegitation bushes / smalll tree growth up to root l level n exc 15cm girth from the RCC chajjas /walls/roof etc by cutting the surrounding area (n exc 300x300mm) up to a depth of 25mm and , making the disturbed surface good by PCC 1: 2:4 type B-0, (using 12.5mm graded aggregate) with and applying one coat of waterproofing solution (Dr Fixit Prime seal Acrylic coating /equivalent) top of the disturbed area ( including necessary arrangements in multy storey bldgs up to G+2 ) complete all as specified & directed.

280

-

-

... More
M & L for Removing all vegitation bushes / smalll tree growth cleaning by picking, sweeping and washing down with water to remove dust,Brooming, Brushing of the RCC roof/Chajja (including necessary arrangements up to three storey bldgs and necessary tools ) and throwing the same low laying area to a distance exc. 250 mtr and not exc 500 mtr from the roof (Total area of each bldg aprox 400 sqm ) etc complete all as specified and directed.etc complete all as specified and directed.

112

-

-

... More
M & L for Removing all vegitation bushes / smalll tree growth cleaning by picking, sweeping and washing down with water to remove dust,Brooming, Brushing of the RCC roof/Chajja (including necessary arrangements up to single storey bldgs and necessary tools ) and throwing the same low laying area to a distance exc. 250 mtr and not exc 500 mtr from the roof (Total area of each bldg aprox 300sqm ) etc complete all as specified and directed.etc complete all as specified and directed.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.