Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date20 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for First quality glazed ceramic coloured tiles of (450x300mm) x 7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge.

81

-

-

... More
M&L for First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
M&L for rendering 12 mm thick in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
M&L for Preparation of new plastered wall surfaces and applying two coats of cement base paint, complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
M&L for Preparation of new plastered or un plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of Chalk whitening complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15 cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified and directed by Engineer-in-Charge.

1.5

-

-

... More
M&L for Plain cement concrete type B-1(1:2:4) using 20 mm graded stone aggregates as bed block ,coping , cills, steps etc complete all as specified and directed by Engineer-in-Charge.

1.5

-

-

... More
Material and labour for draining out sedimentation sludgy water from RCC OH reservoir 50000 Glns capacity -02 nos at 60' feet staging and Semi UG Sump incl scrapping out sticken forieign material from inner side of OH and Semi UG sump walls/Ceiling by wire brush and removing excavated sedimentatation manually and depositing 50 mtr away from OH tank and flushing out the floor with fresh water till satisfaction of Engineer in Charge providing two coats of white wash on old prepared surface cleaning of after completely draining out water from the tank.Writing of cleaning date on the tank complete all as specified and directed by Engineer-in-Charge.The cost of the same shall be deemed included in the respective items. All T&P required for the cleaning of tanks / sumps will be arranged by the contractor.

3

-

-

... More
S&F, in replacement of fully automatic star delta submersible starter with short circuit protection in sheet metal enclousers suitable for 15 HP , 415 Volt 50 Hz with over load protector and phase preventer and taking out old U/S starters of any type and any capacity complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F calcium based Granular for Chlorination of water packed in 45/50 Kg drums and sealed complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
S&F chlorine test kit with PH colured sample complete with all testing fitment and OT solution in rexine box complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house situated in AF stn Dadri complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
M&L for chemical and bacteriological analysis ofchlorinated water collected from distribution line PH NO 1 situated in AF stn Dadri complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Material and labour for "lifting and Lowering of any acpacity" Submersible Pump Set of capacity 15 HP for repair/ Overhauling /rewinding /devolpment incl increasing the length of delivery pipe/or any other requiremwnt at site at tube well installation at AF Station Dadri with man power/Chain Pulley arrangement including shifting to local workshop for repair and to bring back after repair at site including testing and commisioning complete all as specified and directed by Engineer-in-Charge. Note :- Any minor part if required will be provided by contractor without any extra cost.

1

-

-

... More
All as per item No 19 above but Capcity of 10 HP

1

-

-

... More
M & L for Dismantling and strip opening of burnt submersible pump of capacity 15HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning such as (i) Impeller GM . (ii) Distance bush SS.(iii) Guide Bush (iv) Neck ring gun metal (v) Impeller key (vi)Guide van (vii) Sand Guard including tranportation to local work shop etc complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
All as per item No 21 above but 10 HP

1

-

-

... More
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 10 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commisioning including tranportation to local work shop etc complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 10sqmm 3 Core 2run complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
S&F in replacement of self priming recirculation pump set of capacity 3.0 HP / 4.0 KW- RPM-3000 RPM, Head- 14 Mtrs induction motor ( Mono block pump set ) type with fitted on trolly mounted for swimming pool as per existing make and model complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of unserviceable PVC insulated Three core multistanded copper conductor cable 4 Sqmm complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
Disconnecting & dismantling of pump set from the foundation breaking the existing defective PCC foundation in any size, shape M&L for PCC 1:2:4 type B-2 using 12.5 mm graded aggregate for foundation of any size of motor pump set from 50 HP to 75 HP capacity pump set and fitting pumping set in position with base frame painted with synthetic enamel black paint complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in repairs Decrin dozing pump 100 PSI 40 GPD Capacity and testing complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement FRP TANK of Capacity 1as per existing with level gauge with agitator Motor ,connection shaft and mixing blade complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in Repairs Electric motor Single phase 50 HZ 1/8 HP assy Suitable to mount on decrin mixing tank along with agitator shaft and blade complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of connection pipe suitable for connecting to decrin dosing pump to Header( 2 Mtr long 8 mm internal dia) complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of circuit of speed of Dozing pump complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of injector Nozzle of Decrin dozing pump complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of Regulator Knob of dozing pump complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of power cord of dozing pump 2 mtr long plug top 5 AMP 240 volt AC complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110 complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45 complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 25 to 32 complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX upto 18 complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing in replacement of unserviceable MCCB 63 amps 415 volts TP 16 KA complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement amp meter digital type as per existing size and type complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement volt meter digital type as per existing size and type complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repair CT 30/5 to 200/5 complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repair indicating light with bulb set of three complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 400 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of DOL starter for 10 HP with complete protection complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Material & Labour for repairs to existing LT panel board at Pump houses including painting with one coat of synthetic enameled paint to steel surfaces including preparation after scraping, filling, cavities etc, including replacement of damaged bus bar, lugs, copper wire etc complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing MCCBs 415 volts, 4 pole, 16 KA, 100 Amps capacity complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S & F Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S & F Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S & F Selector switch for Volt meter /Ampmeter complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S & F Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supply and laying and testing in replacement of unserviceable for Ductile Iron pipes of 150 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed by Engineer-in-Charge.

250

-

-

... More
Excavation in trenches, in soft/loose soil, not exceedings 1.5 Meters in width and not excedings 1.5 Meters in depth for laying of Cast Iron/Ductile Iron pipes or Steel water tubings etc and getting out including forming bottom surface and sides complete all as specified and directed by Engineer-in-Charge. Note : While removing the pipe line. Contractor shall replaced the broken item with new as per existing . The quoted rates including for all the materials / t&p / machinery used in this item no material can paid / measured seperately

531

-

-

... More
Returning filling-in,of soft/ loose soils, including spreading levelling watering and well ramming in layers not exceedings 25 Cm thick complete all as specified and directed by Engineer-in-Charge.

343

-

-

... More
Removing of surplus excavated material (Soil) not exceedings 50 Meters and depositing where directed at a level not exceeding 1.5 Meters above the startind point complete all as specified and directed by Engineer-in-Charge.

188

-

-

... More
Supply and fixing in replacement of unserviceable GI tubing medium grade with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
All as per item No 58 above but 50 mm dia.

250

-

-

... More
All as per item No 58 above but 40 mm dia.

100

-

-

... More
All as per item No 58 above but 25 mm dia.

200

-

-

... More
All as per item No 58 above but 20 mm dia.

100

-

-

... More
All as per item No 58 above but 15 mm dia.

100

-

-

... More
Supply and laying and testing in replacement of unserviceable cast iron pipes of 200 mm bore with spigot and socket ends centrifugally cast class LA in any length laid in trenches including taking down complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
All as per item No 64 above but 150mm bore

20

-

-

... More
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
All as per item No 66 above but 50 mm dia.

6

-

-

... More
All as per item No 66 above but 25 mm dia.

10

-

-

... More
All as per item No 66 above but 20 mm dia.

5

-

-

... More
All as per item No 66 above but 15 mm dia.

10

-

-

... More
Taking out/burning out of leaking and damaged lead joints of the existing CI mains from the position including removing the old lead carefully with out damaging to the pipe complete for the following bore of pipes size 80 mm bore complete all as specified and directed by Engineer-in-Charge. Note :- Excavation and earth work will be measured and paid separately

5

-

-

... More
All as per item No 71 above but 100 mm bore

10

-

-

... More
All as per item No 71 above but 150 mm bore

10

-

-

... More
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and Supply & fixing CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes complete all as specified and directed by Engineer-in-Charge:-

-

-

-

... More
All as per item No 74 above but 200 mm dia bore of pipe

1

-

-

... More
All as per item No 74 above but 150 mm dia bore of pipe

3

-

-

... More
All as per item No 74 above but 100 mm dia bore of pipe

2

-

-

... More
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 100 mm dia complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 150 mm dia complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Dismantling the components of Reverse Osmosis plant (250 Ltrs per hour capacity 01 Nos) and checking the serviceability of plant including rubber bushes,fittings,low pressure /high pressure motor pumps and re fixing the same after necessary repairs and replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply and Fix Jumbo platred filter cartridge poly propyline of 5 micron 20" complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F in RO membrane filter of model 40-40 as existing size and capacity of RO plant including testing and commissioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L sand dual media in replacement for main RO filter complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L carbon media in replacement for main RO filter complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L Anti scalant chemical in packing suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F in repairs in repairs dual control Dozing pump,6 LPH,5.5 BAR suitable for RO plant, 250 LPH capacity as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F in repairs in repairs Raw water pump 0.5 HP , for RO plant, 250 LPH capacity as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F in repairs in repairs high pressure pump 1.0 HP, for RO plant, 250 LPH capacity as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F in repairs in repairs Control panel , for RO plant, 250 LPH capacity as existing sample including testing and commissioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L for dismantling and taking down mono block booster pumps/Non clogging sewage pump up to 5HP motor for repair/overhauling including disconnecting, transporting to local workshop for repair/reassembling the same after replacing following work out spares including alignment and replacement of foundation bolts and necy civil works like plastering brick work, PCC for foundation:(i) Replacement of pump bearing (as per sample)-02 nos (ii) repair /straighteing of Pump shaft. (iii) Replacement of glands/nuts/bolts -01nos. (iv) replacement of shaft key -01 nos.( v) repalcemnt of Pump Impeller complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply and fix Fountain light multi colour fitting complete With complete all as specified and directed by Engineer-in-Charge

12

-

-

... More
Supplying and laying of CPVC pipes of size 40mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches / fountain complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
Supplying and laying of CPVC pipes of size 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches / fountain complete all as specified and directed by Engineer-in Charge

25

-

-

... More
S&F PPR Gate valve 20mm fittings in trenches / fountain complete all as specified and directed by Engineer-in Charge

12

-

-

... More
S&F Water sprinklar Nozle 20/15mm complete all as specified and directed by Engineer-in Charge

12

-

-

... More
S&F Water level Indicator for over head tank, water level display wired sensor security system with alaram system having power input 230V, 50 Hz, including electrical cable complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F Foot valve of size 80mm suction pipe complete all as specified and directed by Engineer-in Charge

1

-

-

... More
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 6 sqmm 3 Core complete all as specified and directed by Engineer-in Charge

100

-

-

... More
Supply, installation , commissioning and testing of LT Panel Board outdoor type factory made out of CRCA sheet 3.15 mm thick dust & vermin proof , front and rear opening shutters having locking arrangement totally enclosed weather proof, antirusted powder coated including aluminium Bus Bar of 250 Amps rating of suitable length, 440 volts, 3 Phase 4 wire 50 Hz mounted on suitable type of insulators. complete with bottom removable gland plates, as required, all internal connection wiring by min. 2.5 Sqmm. copper wires, Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB and instrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT's, etc complete mounted on suitable size of MS angle frame stand of minimum 450 cm height from ground l;evel incl PCC and earh work required to fix the stand , The panel board shall be comprising of the following complete all as specified and directed by Engineer-in-Charge :- (a) Incommer - MCCB 4 POLE 415 V 200 A (35 kA) - 01 Nos Outgoing (a) MCCB 4 POLE 415 V 125 A (25 kA) )- 02 Nos (b) MCCB 4 POLE 415 V 63 A (25 kA) - 03 Nos (c) Blank chamber - 01 Nos with din rail sutable for fixing 03 Nos TP/TPN MCBs (d) Starter for 15 HP submersible pump -02 (1 + 1 Standby) (e) Starter for 12.5 HP Centrifugal pump -04 (2 +2 standby) (f) Single phase protection

1

-

-

... More
Supply, installation , commissioning and testing of LT Panel outdoor type factory made out of CRCA sheet 3.15 mm thick dust & vermin proof , front and rear opening shutters having locking arrangement totally enclosed weather proof, antirusted powder coated including aluminium Bus Bar of 400 Amps rating of suitable length, 440 volts, 3 Phase 4 wire 50 Hz mounted on suitable type of insulators. complete with bottom removable gland plates, as required, all internal connection wiring by min. 2.5 Sqmm. copper wires, Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB and instrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT's, etc complete mounted on suitable size of MS angle frame stand of minimum 450 cm height from ground l;evel incl PCC and earh work required to fix the stand , The panel board shall be comprising of the following complete all as specified and directed by Engineer-in-Charge. (a) Incommer - MCCB 4 POLE 415 V 250 A (35 kA) - 01 Nos Outgoing :- (a) MCCB 4 POLE 415 V 100 A (25 kA)- 02 Nos (b ) MCCB 4 POLE 415 V 63 A (25 kA) - 04 Nos (c) Blank chamber - 01 Nos with din rail sutable for fixing 04 Nos TP/TPN MCBs (d) Digital ammeter 0-500 A flush type square with selector switch & CTs -01 No (e) Digital voltmeter 0-500 V flush type square with selector switch -01 No

1

-

-

... More
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge

112

-

-

... More
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge

10.92

-

-

... More
Taking down UNSV LT Under Ground cable of any size complete all as specified and directed by Engineer-in-Charge

1980

-

-

... More
Labour only for laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge Note: Cable will be issued for store under Schedule "B"

150

-

-

... More
All as per item No 104 above but 2 core 25 Sqmm.

280

-

-

... More
All as per item No 104 above but 3.5 core 50 Sqmm.

500

-

-

... More
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.

100

-

-

... More
All as per item No 107 above but 3.5 core 25 Sqmm.

150

-

-

... More
All as per item No 107 above but 3.5 core 50 Sqmm.

150

-

-

... More
All as per item No 107 above but 3.5 core 70 Sqmm.

150

-

-

... More
All as per item No 107 above but 3.5 core 95 Sqmm.

200

-

-

... More
All as per item No 107 above but 3.5 core 120 Sqmm.

200

-

-

... More
All as per item No 107 above but 3.5 core 240 Sqmm.

100

-

-

... More
Supply & fixing or laying in replacement HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etc as reqd at site and complete all as specified and directed by Engineer-in-Charge Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.

20

-

-

... More
Supply & fixing in replacement MCCB TPN 63 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply & fixing in replacement MCCB TPN 100 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply & fixing in replacement MCCB TPN 125 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg

3

-

-

... More
Supply & fixing in replacement MCCB TPN 160 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 200 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 250 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

2

-

-

... More
Supply & fixing in replacement MCCB TPN 400 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg

1

-

-

... More
Supply & fixing in replacement MCCB TPN 630 Amps 415 Volts 50 kA complete all as specified and directed by Engineer-in-Charg

1

-

-

... More
M / L for checking electrical /electronic circuit for finding out fauilty capacitors and replacement with Ultra heavy duty box type capacitor suitable for 440 volt 50 Hz operation of rated capacity 20 kVAr including taking down old unserviceable capacitor and and making all circuit connection and testing for smooth functioning complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
All as per item No 123 above but 10 kVAr

1

-

-

... More
All as per item No 123 above but 5 kVAr

1

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
All as per item No 126 above but cable of size 70 to 120 sq mm.

5

-

-

... More
All as per item No 126 above but cable of size 120 to 240 sq mm.

3

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 400 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply and fixing in replacement of on load changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and directed by Engineer-in-Charge

100

-

-

... More
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.

6

-

-

... More
All as per item No 134 above but using GI Strip 25x4 mm as earthing lead

4

-

-

... More
M&L for Chemical earthing , Design development supply commissioning and testing EHCC certified ground terminal earthing system hollow tube solid bar CCPRI tested for sensitive signal/Electrical equipments highly anti corrosive long life severe wear conditions in the earth pit and of standard size ISI marked copper tube out side secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal confirming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete incl PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed by Engineer-in-Charge Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.

2

-

-

... More
Supply and fixing in repair of Earth continuity GI wire of 4 mm dia or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
All as per item No 138 above but Copper Strip 20x3 mm

120

-

-

... More
S&F in replacement of outdoor type LED flood light 70 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
Surface dressing in soft/loose soil not exceeding 15 cm deep complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
M&L Broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick incl spreading lime stone powder under stones complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
Repair and replacement of hydraulic crimping machine with crimping range from 10 sqmm to 400 sqmm with standard dies from 10 mm to 400 mm complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
Repair and replacement of synthetic insulating mat of thickness not less than 3.0 mm size 2.0 mtr X 1.0 mtr suitable for system voltage 3.3 kV and break down voltage 45 kV confirming IS 15652 : 2006 complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
S&F in repair LED Street Light Luminaries 70/ 75 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
S&F in repair LED Street Light Luminaries 60 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
M&L for detecting of fault in LT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM complete all as specified and directed by Engineer-in-Charge. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.

2

-

-

... More
Supply and fixing in replacement of Cylindrical shaped (FLUTE) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingPCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge

25

-

-

... More
Supply and fixing in replacement of LED post top 20 W in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
M&L for surface cleaning of LT electric panel (cubicle type ,size /capacity as per existing) installed at different location in the Stn including scrubbing /rubbing (old paint)all body surface to get all foregin particals removed off and applying two coat of spray painting with synthetic enamel paint (deco paint and existing colour )over a coat of metal primer(red oxide primer ) and disconnecting of all electrical connection like bas bar, CTs,MCCBs and all wirings,equipments and refix ( reconnection) with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
M&L for Replacement to unserviceable batteries of 12 volts 180 AH with new batteries of 12 volts 180 AH maintenance free complete all as specified and directed by Engineer-in-Charge Note: Rate for initial charging are included in unit rate

4

-

-

... More
M&L for taking out from trenches, wall, pole , Pipe, PCC, under ground, etc exsisting cable LT 1100 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable cable lenght ,unserviceable cable lenght and unuse cable lenght by meggering or any other suitable and recommended method including disconnection and re-connection of Cables. Removing unserviceable and unuse cable leght from site and keeping aside serviceable for reuse OR laying New cable supplied by dept at same location or any other location complete all as specified and directed by Engineer-in-Charge Note : Earth work will be measured and paid separately under respective item

150

-

-

... More
M&L for Dehydration including filteration and cleaning of transformer oil by centifugal dehydration machine till to achieve Di-electric strength 55 KV at 2.5 mm gap testing of sample before and after dehydration and filteration complete all as specified and directed by Engineer-in-Charge Note- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job.

1000

-

-

... More
Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed by Engineer-in-Charge Note : Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.

100

-

-

... More
Repair maintainance of oil cooled servo voltage stablizer of capacity up to 200 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component complete all as specified and directed by Engineer-in-Charge Note:- The replacement spare parts shall be measured and paid separately.

1

-

-

... More
Supply Only spare part of the Voltage stablizer up to 200 KVA as following:-

-

-

-

... More
Spring loaded finger

1

-

-

... More
Microproccessor Based eletronic control board

1

-

-

... More
Rewinding of Auto Transformer up to 200 KVA

1

-

-

... More
Selector switch

1

-

-

... More
Voltmeter digital type

1

-

-

... More
Amperemeter digital type

1

-

-

... More
S&F in replacement of outdoor type LED flood light 200/210 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
Repair and replacement of Digital Clamp meter for measuring current, voltage and other parameters , AC current range 600 A, AC voltage range 600 Volt, data hold , Auto range, low battery indicator, Auto power off and buzzer, CAT II 600 V safety category incl batteries and complete accessories complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply, installation , commissioning and testing of LT Panel Board Indoor type factory made out of CRCA sheet 3.15 mm thick dust & vermin proof , front and rear opening shutters having locking arrangement totally enclosed weather proof, antirusted powder coated including aluminium Bus Bar of 400 Amps rating of suitable length, 440 volts, 3 Phase 4 wire 50 Hz mounted on suitable type of insulators. complete with bottom removable gland plates, as required, all internal connection wiring by min. 2.5 Sqmm. copper wires, Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB and instrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT's, etc complete mounted on suitable size of MS angle frame stand of minimum 450 cm height from ground l;evel incl PCC and earh work required to fix the stand , The panel board shall be comprising of the following :- (a) Incommer - MCCB 4 POLE 415 V 400 A (35 kA) - 02 Nos (b) ON load Change over Switch 400 Amps 4 Pole -01 Nos Outgoing :- (c) MCCB 4 POLE 415 V 125 A (25 kA)- 04 Nos (d ) MCCB 4 POLE 415 V 63 A (25 kA)- 03 Nos (e) Blank chamber - 01 Nos with din rail sutable for fixing 03 Nos TP/TPN MCBs

1

-

-

... More
Supply, installation , commissioning and testing of LT Panel outdoor type factory made out of CRCA sheet 3.15 mm thick dust & vermin proof , front and rear opening shutters having locking arrangement totally enclosed weather proof, antirusted powder coated including aluminium Bus Bar of 320 Amps rating of suitable length, 440 volts, 3 Phase 4 wire 50 Hz mounted on suitable type of insulators. complete with bottom removable gland plates, as required, all internal connection wiring by min. 2.5 Sqmm. copper wires, Panel shall be comprising of seperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB and instrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT's, etc complete mounted on suitable size of MS angle frame stand of minimum 450 cm height from ground l;evel incl PCC and earh work required to fix the stand complete all as specified and directed by Engineer-in-Charge. The panel board shall be comprising of the following :- (a) Incommer - MCCB 4 POLE 415 V 160 A (35 kA) - 01 Nos Outgoing :- (b) MCCB 4 POLE 415 V 32 A (25 kA)- 02 Nos (c ) MCCB 4 POLE 415 V 63 A (25 kA) - 02 Nos (d) Blank chamber - 01 Nos with din rail sutable for fixing 04 Nos TP/TPN MCBs

1

-

-

... More
Supply, installation, commissioning and testing automatic intelligent power factor corrector (APFC) capacitor bank with MD-XL capacitor for LT 3 phase 440 volts system 50 C/S AC supply to improve PF 0.70 to 0.99 or unity automatically step wise switch capacitor panel floor mounted out door type, weather proof dust/vermin proof protection IP-54 type made out of MS sheet 14 SWG and angle iron 40mmx40mmx6mm frame factory made fabricated as modular in construction duly powder coated light grey colour painted, front openable panel shutter with locking arrangement to facilitate easy maintenance complete, natural air cooled cable entry with gland plate with provision of PCC 1:3:6 type C-I, 450mm below ground and 450mm above ground level all around legs complete of cap 200 KVAR, complete all as specified and directed by Engineer-in-Charge (a) Auto electric load select management system single phase integrated micro processor based electronic automatic electric load management system controller unit ECU processor for sensing reactive power demand with by pass arrangement to keep (AGLMS) in working condition including time delay functioning for spacing the switching time auto switching off facility in case of leading power factor auto/manual selector switches HRC fuse for back up protection built in natural air cooled. (b) APFC microprocessor base relay including isolation MCCB 100 Amps with 25 KA rupturing capacity. (c) Protection devices (MCB) against short circuiting over loading and isolation in the unlikely events of failure in step switching single phasing protection low/high voltage protection in balancing protection with indicating lamps current sensors (CVTs)-01 set.

1

-

-

... More
Note : All as per item No 168 contd..../- (d) Naturally air cooled MPP double dielectric heavy duty 440 volt LV 50 HZ shunt power capacitors conforming to IS-13340 and 13341 and IEC 831-I, ISI marked designed on ambient temperature 10 degree to 50 degree celcies delta connections complete with metal base enclosure copper wire connection for banking complete with watt loss not more than 0.5 watt/KVAR complete No of stepping combinations of 200 KVAR each (e) Int. wiring with adequate size of PVC insulated copper multistranded cable with necessary lugs thimbles/glands-01 Job. Note : The APFC panel should be so designed to accommodate 10% extra space only for future expansion. (f) PVC insulated armoured multi-stranded 3.5 core 1100V grade cable 400 Sqmm for incoming power supply of length not less than 10 meter. (g) The rate quoted shall deemed to include for cable connection incl. cable glands and earth connection with GI strip 25X6mm (as per current capacity) including necessary jointing material to existing earth lead.

-

-

-

... More
Supply ,and errection in true vertical position steel tubular swaged pole type 410 co SP-31 , 09 mtr long complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws incl painting with synthetic anamelled aluminium paint two coat over one coat of red oxide primer after errection and providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole all as specified and as directed by Engr-in-charge. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.

3

-

-

... More
Supply and fixing stay assembly complete with all accessories, such as stay plate 230X230X6 mm3, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 and as directed incl taking down old unsv complete all as specified and directed by Engineer-in-Charge Note: Only excavation and PCC work will be measured and paid separately.

2

-

-

... More
Supply, installation, testing and commissioning of LT panel out door type made out of 3.15 mm thick CRCA sheet, suitable angle iron frame for structure and base, copper busbar 1000 amps rated with SMC busbar supports - 04 Nos, dust/vermin proof, epoxy powder coated siemens grey painting over a coat of red oxide primer inside/outside of the panel, double shuttered with locking arrangements, cable alley, anodized aluminium with black background with white engraved letter of name plates, schematic diagram for distribution, rubber gaskets, cable glands and internal copper wirings with appropriate lugs complete including necessary civil works and making good disturbed surfaces with following accessories complete all as specified and directed by Engineer-in-Charge. (CPRI Approved) Incoming (i) MCCB four pole, 50 KA, 400 Amps (adjustable type) - 01 No (ii) Onload change over switch 400 Amps, four pole - 01 No Outgoing (i) MCCB four pole, 36 KA, 250 Amps (adjustable type) - 02 No (ii) MCCB four pole, 36 KA, 200 Amps (adjustable type) - 02 No (iii) MCCB four pole, 25 KA, 125 Amps (adjustable type) - 02 No (ii) MCCB four pole, 16 KA, 100 Amps (adjustable type) - 02 No Meter (i) Digital Ammeter with LED indication lamp with selector switch -1 Nos (ii) Digital voltmeter with LED indication lamp with selector switch -1 Nos

1

-

-

... More
Supply and fixing in replacement of Retro reflective sign board of size 900 mm X 1200 mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on SS (Stainless Steel ) frame of with legs of Stainless steel (SS) on PCC 1:3:6 type 2.10 mm above The ground level and 750 mm below the ground level. The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed by Engineer-in-Charge

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.