Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical and Electronics
Eprocure
Opening Date5 Sep 2024
Closing Date12 Oct 2024
Tender Amount₹ 55,31,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense soil for laying of cables complete all as specified and directed.

858

-

-

... More
Returning, filling in trenches including spreading, leveling watering well ramming layers not exceeding 25mm complete all as specified and directed.

772

-

-

... More
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.

81

-

-

... More
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.

1520

-

-

... More
S&F of Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.

20

-

-

... More
Material and Labour for sub main wiring 2runs x 1.5 sqmm (Ph & N) + 1run x 1.5 sqmm (earth wire) along with earth wire with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid steel conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed for the following sizes:- Note: Three runs of copper cable and one run of rigid steel conduit shall be measured as one RM unit length.

400

-

-

... More
Supply and fix of Flame Proof SSPL /1233 or EquvelentLED street/security light fitting 60 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.

20

-

-

... More
Supply and fix of flame proof MCCB / MCB distribution board, SPN, 6 way, 230 Volt, Single phase, AC and MCBs(Incoming MCB, 2 pole;32A-01 No and outgoing MCB 1P, 6 Amp-4 Nos) in sheet steel powder painted enclosure(300 x 300 x 190 mm) with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.

4

-

-

... More
Supply and fixing steel tubler swaged pole completed with cast iran base plate, finial tapper plug, bolts, nuts and screws as specified type 410 SP-22(8.5) Mtr long including necessary excavation in any type soil, returning filling and removal of extra/surplus earth, concerete bed in PCC 1:3:6 type C-2 using 40mm crushed stone aggregate upto ground level and above ground level 450x450x450mm PCC coping 1:2:4 type B-1 by using 20mm aggregate complete all as specified and directed.

68

-

-

... More
Supply and fixing of 120 Watt Flame Proof SSPL /1233 or Equvelent WattnLED street light fitting made up of pressure die-cast aluminium alloy housing with toughened glass, IP protecgtion and and indivisual high power LEDs with secondary optics having system lumen efficacy ≥100 Im/W Inbuilt potted electronic LED driver with APFC (SMPS based constant currently supply), lower THD, open circuit protection, over Voltage protection, surge Voltage protection & other Safety test as per IS 15885 Part-2/Sec 13 and BIS Complying complete all as specified and directed.

9

-

-

... More
Supply and fix in replacement of street light control panel board 12 KV capacity, 3 Ph, 4 Wire, company made with CRCA Sheet Steel with front openable door fitted with necessary hinges, door locking by Panel lock duly phosphatized and powder coated with 7 tank process and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable gauge of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including of following switchgears/ components :- (a) Incoming MCB, TPN, 63 Amps, 10KA - 01 No. (b) 3 pole contactor, 65 Amps - 01 No. (c) Digital timer for 24 hours programming - 01 No. (d) Auto/Manual selector Switch - 01 No. (e) Terminal block 3 Ph, 4 wire for incoming & outgoing - 01 set

3

-

-

... More
Supply and fix in replacement of GI pipe bracket made out of 40mm dia medium grade GI pipe of 1.50mtr long bent to required shape and fixed to steel tubular / PCC pole with flat iron clamp nuts, bolts and washers etc complete all as specified and directed.

68

-

-

... More
Spply and fix SMC (sheet moulded compound) outdoor type junction box of size 240mm X 130mm X 95mm (Outside Dimensions) with 63Amps rated four pole connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables including fixing on steel tubular poles / PCC poles with 25mm X 4mm MS clamps (02 Nos), nuts & bolts etc complete all as specified and as directed.

68

-

-

... More
M & L for making holes (02 Nos in each pole - one near cable junction box and other near street light bracket) on existing steel tubular poles of any type, thickness & height through drilling / gas welding work having smooth and chamber edge of hole, for drawing street light control cable through inside of pole complete all as specified and directed.

68

-

-

... More
Supply and fix an replacement of 40mm dia bore tubes, 'light grade' galvanized, with a lfitting and fixed complete to wall/ pole or laid in trenches/ floors for cables protection complete all as specified and directed.

135

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 10 sq. mm nominal cross section, 2 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.

100

-

-

... More
Suppply , laying and testing cable XLPE insulated , screened, PVC Bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standerd aluminium conducter of size 25 sq mm 4 core complete all as specified and directed.

470

-

-

... More
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregated) as in foundation filling and mass concerting complete all as specified and directed.

40

-

-

... More
Supply, installation, testing and commisioning of air cooled split type Air conditioner ( Cooling and heating type) of 2TR capacity comprising of one indoor and one outdoor unit, wall mounted type comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having Five Star rated / inverter technology with and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed. Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and clectrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. Make: LG, Voltas, Hitachi, Daikin, Carrier, Blue Star.

7

-

-

... More
Supply, connect & testing of automatic voltage stabilizer, 4 KVA capacity wall mounted type for low voltage cut-off, single phase, AC, 50 Hz, 15 Amps rating ,suitable for input voltage range 160V-280V AC with 3min±20 sec delay for Air Conditioner Complete all as specified and directed.

7

-

-

... More
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4.0 sqmm + 1 run x 4.0 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one RM unit length.

70

-

-

... More
S&F, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole20 Amp MCB, 240 volts, complete all as specified and directed.

7

-

-

... More
Supply and fix MCB distribution board, SPN, 4 way, 240 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.

7

-

-

... More
S& F MCB SPN 40- 63 Amp, 10 KA, 'C' curve, 240 V, 50 Hz complete all as specified and directed.

7

-

-

... More
S& F MCB SP 6-32 Amp, 10 KA, 'C' curve, 240 V, 50 Hz complete all as specified and directed.

7

-

-

... More
Supply and fixing in replacement of 90 WattnLED street light fitting made up of pressure die-cast aluminium alloy housing with toughened glass, IP-66 protecgtion and and indivisual high power LEDs with secondary optics having system lumen efficacy ≥100 Im/W Inbuilt potted electronic LED driver with APFC (SMPS based constant currently supply), lower THD, open circuit protection, over Voltage protection, surge Voltage protection & other Safety test as per IS 15885 Part-2/Sec 13 and BIS Complying complete all as specified and directed.

59

-

-

... More
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II (ii) Earthing test report with value less than 2 Ohm should be submmited by contractor before claiming the payment.

17

-

-

... More
Taking down carefully the Ceiling fan of any discription from its installed position by disconnecting all electric supply connections and shall be deposited to AGE E/M yard for necessary repairs/replacment complete all as specified and directed.

228

-

-

... More
Supply and fix of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper winding with brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose all as specified and directed. Note: Old Ser/ UNSV fans removed from the site shall be the properety of Department, which shall be deposited as directed by Engr-in-Charge.

228

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.