Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jan 2023
Closing Date18 Feb 2023
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Description all as per Item No 2 here-in-before but for wall mounted fan/cabin fan of size up to 450 mm sweep complete all as specified and directed.

10

-

-

... More
M&L for rewinding of ceiling fan motor 1200/1400 mm sweep any make with super enameled copper winding wire ISI marked of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing , threading incl. making connections with three core copper flexible wire of suitable size and reassembling the same and two coats of synthetic enamel paints with spray painting and writing MES number ind. cleaning the fan with cleaning materials or thimmbles after testing at full load with blades to the entire satisfaction of Engineer incharge complete all as specified and directed. Note: Rewinding work of ceiling fan/ exhaust fan/ cabin/wall mounted fan shall be carried out inside the camp area at the location provided by department.

680

-

-

... More
Description all as per Item No 5 here-in-before but exhaust fan of size 300 mm sweep, 230 V, AC complete all as specified and directed.

150

-

-

... More
Description all as per Item No 5 here-in-before but exhaust fan of size up to 450 mm sweep, 230 V, AC complete all as specified and directed.

20

-

-

... More
Description all as per Item No 5 here-in-before but for wall mounted/cabin fan of size up to 450 mm sweep complete all as specified and directed..

16

-

-

... More
M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as directed.

75

-

-

... More
S&F in repair Ball bearing of ceiling fan of size 6201/6202 complete all as specified and directed.

680

-

-

... More
S&F in repair Ball bearing of exhaust fans of size 6203/6204 complete all as specified and directed.

180

-

-

... More
S&F in repair Gun metal bushes for exhaust fans of suitable sizes complete all as specified and directed.

40

-

-

... More
S&F in repair PVC clamp of suitable size for capacitor of fans complete all as specified and directed.

900

-

-

... More
S&F in repair capacitor 2.5 MFD, 230V, AC complete all as specified and directed.

1350

-

-

... More
S&F in repair capacitor 3.15 MFD, 230V, AC complete all as specified and directed.

100

-

-

... More
S&F in repair capacitor 4 MFD, 230V, AC complete all as specified and directed.

10

-

-

... More
S&F in repair shackle rubber bush/rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as specified and directed.

400

-

-

... More
S&F in repair flexible wire 23/0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as specified and directed.

400

-

-

... More
S&F in repair MS nut & bolt with cut washers 8 mm dia and safety pin of suitable length for hanging of the ceiling fans complete all as specified and directed.

200

-

-

... More
S&F in repair MS clamp including rubber washer, nut, bolt, washer and safety pin for hanging the ceiling fans of suitable size complete all as specified and directed.

100

-

-

... More
S&F in repair Down rod MS 15mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as specified and directed.

10

-

-

... More
S&F in repair Down rod MS 15mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as specified and directed.

10

-

-

... More
S&F in repair ceiling fan regulator electronic switch type 5 stage speed variation ISI marked complete all as specified and directed.

400

-

-

... More
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.

300

-

-

... More
M&L for preparing the surface of ceiling fan, exhaust fan, pedestal fan including cleaning, removing grease, carbon dust and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number complete all as specified and directed.

555

-

-

... More
Disconnecting and taking down old energy meter and Supply, installing, testing & commissioning of smart RF single Phase meter with AC single phase two wire, tamper proof static meter of class 1.0, 240 V, 50 Hz, 10 A to 60 A confirming to IS-16444 and relevant IEC standards within built 865-867 MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti temper features, Microprocessor and LED/LCD based circuitry. Meter should support sending the 15/30 mint instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and Max demand to software data. Meter should have connect/disconnect functionality operable from MDM/billing software and prepaid features should be MDM/billing end as per IS-15959 part 2. The meter should support open communication protocol DLMS with the software complete all as directed. Make:- L&T cat part No. WM101BC7DLPR6INN or equivalent in Secure/Havells/HPL Note:- Old Electric meter shall be deposited at E/M store yard.

15

-

-

... More
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.

140

-

-

... More
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 2 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.

100

-

-

... More
All as per item No. 28 above but for one 5 pin 5 Amp socket outlet point on an independent board.

10

-

-

... More
All as per item No. 28 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.

20

-

-

... More
All as per Item No 28 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.

10

-

-

... More
S&F Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.

130

-

-

... More
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.

10

-

-

... More
S&F socket outlet, flush type, single pole, 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.

30

-

-

... More
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 6 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and directed.

10

-

-

... More
S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50 mm dia complete all as specified and directed.

100

-

-

... More
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 volts, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Halonix Cat part No- HLTLD-04-20-CW-HL2, ORIENT Cat part No-LBLN-20-C-AL /Phlips Cat part No- BN021C LED22S PSU CW GR

150

-

-

... More
S&F in replacement of exiting unsv light with recess mounted 6 Watts LED downlight, aesthetically designed PC housing with constant driver including making all electric connections complete all as specified and directed. Make:-ORIENT Cat part No. LDRVP-06-C/ Halonix Cat part No- HLDLR-R21-R06-CW-PC/ Havells Cat Ref- INTEGRAHEDLR 7WLED857S

20

-

-

... More
S&F in replacement of exiting unsv light with recess mounted 12 Watts LED downlight, aesthetically designed PC housing with constant driver including making all electric connections complete all as specified and directed. Make:-ORIENT Cat part No. LDRMP-012-C/ Halonix Cat part No- HLDLR-S21-12-CW-PC/Havells Cat Ref- INTEGRAHEDLR 12WLED857S.

20

-

-

... More
S&F in repair mild steel louvers/shutters suitable for 300 mm sweep exhaust fan complete all as specified and directed.

30

-

-

... More
S&F in repair mild steel louvers/shutters suitable for 450 mm sweep exhaust fan complete all as specified and directed.

15

-

-

... More
Dismantling of existing meter panel board removing existing energy meter keeping safe custody and Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.

5

-

-

... More
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover

-

-

-

... More
(f) LED Indicating lamp - 03 Nos. (g) Internal wiring with 1100 Volt grade 6.0 Sqmm FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make :- Hansel / Schneider/ L&T/Schneider

-

-

-

... More
Dismantling of existing meter panel board removing existing energy meter keeping safe custody and Design, Supply, installation, testing and commissioning of indoor type wall mounting size approx (1280 X 775 X 245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.

3

-

-

... More
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 08 nos in separate chamber with locking arrangement. (a) Four pole MCCB 100 Amps with breaking capacity 25 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (b) MCB DP 32 Amp 10 KA, C Curve - 8 Nos (To be connected with 8 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover

-

-

-

... More
(f) LED Indicating lamp - 03 Nos. (g) Internal wiring with 1100Volt grade 6.0 Sqmm FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make :- Hansel / Schneider/ L&T/Siemens

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.